HomeMy WebLinkAbout274 Nutmeg Road South (5)ackap g
St 1
PACKAGE INDUSTRIES, INC. 2!! - building
SYSTEMS
15 Harback Road • Sutton,MA 01590•(508)865-5871 •FAX:(508)865-9130
4/27/01
Aldrich Const . Co. Inc .
48 Stock Place
Manchester, CT 06040
Re : Total Fitness Job No. 0104-023
22 Chapel Road
South Windsor, CT 06074
Section A: 76' Width x 104 ' Length x 20' E.H. x 1 . 0 : 12 Roof Slope
w/ Bay Spacing 4 at 261 .
Section B : 32' Width x 79' Length x 17 . 33 ' E.H. x 1 . 0 : 12 Roof Slope
w/ Bay Spacing 2 at 2611 1 at 271 .
Section C: 30 . 67' Width x 70' Length x 10 . 58' E.H. x 1 . 0 : 12 Roof Slope
w/ Bay Spacing 17 . 341 , 12 . 341 , 10 . 67' , 12 . 34' , 17 .34' .
Gentlemen:
This is to certify the above referenced building and its components have
been designed in accordance with design procedures as specified in the
following specifications . Loads are applied in accordance with the Building
Code stated below.
American Institute of Steel Construction (AISC) - 9th Edition
AISI Specification for the Design of Cold-formed Structural Steel - 1996
American Welding Society Structural Steel Welding Code (AWS D1 . 1-98)
Building Code : BOCA 96 w/ 199 CT Supplement
Dead Load: Metal building structure only as furnished by
Package Industries, Inc . or 3 psf minimum.
Collateral Load: 5 psf Live Load: 20 psf
Wind Load: 80 mph Exposure- B Wind Imp. Ftr. - 1 . 04
Ground Snow: 30 psf Exposure (Ce) : 0 . 7 Roof Snow Load: 30 psf + Drift
Mech. Load(s) : (1) 600 lb. AHU, (1) 1200 lb. AHU, (4) 300 lb. UH Heaters
Seismic : Av= 0 . 11 Aa= 0 . 15 Seismic Imp. Ftr. - 1 . 00
R= 4 . 5 (Ordinary Moment Resisting Steel Frames)
R= 5 . 0 (Roof & Wall X-bracing)
W= (0 . 20) (Snow) + Dead
This Letter of Certification applies solely to the building and its
component parts as furnished by Package Industries, Inc. , and specifically
excludes any foundation, masonry, or general contract work, including
inspection and erection certification.
The Design and Certification for this project is in accord with the
provisions and loads specified in the Order Documentation. The buyer is
responsible to verify that specified loads are in compliance with the
local regulatory authorities .
r
Sincerely,
Kenneth F. Mann, P.E.
MAY 18 RECD