HomeMy WebLinkAbout26A-26J Amato Drive (9)FOR Of;FICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: 5 31 95'
N0, v T74 ) TOWN OF SOUTH WINDSOR EST.COST: 5-c)O.66
BLDG. PERMIT N0. lYR 1540 SULLIVAN AVENUE FEE 00
SOUTH WINDSOR, CT 06074 FEES:
644-2511 - Ext. 230
0 - $1,000 - $10.00
1000 or fraction
LOCATION OF BUILDING
Q C (v/!o/i.ivrra thereof - $10.00
5' / 'gz
OWNER Y ADDRESS TOWN PHONE NO.
v s S 76C',
HVAC CONTRACTOR ADDRESS TOWN PHONE NO.
TYPE OF SYSTEM: HEATING 13 r TYPE OF BUILDING: RESIDENTIAL
A/C COMMERCIAL
VENTILATION BUSINESS
INDUSTRIAL
IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
HYDRONIC V WARM AIR
UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE)
TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW
WOOD COAL
OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY
LPG TANK - CAPACITY
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS (BTUH) HEAT LOSS SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.):
GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH)
IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN (BTUH)
HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLINNG EQUIPMENT (INCLUDING MAKE & MODEL NO.)
TONNAGE COOLING CAPACITY (BTUH)
IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT) :
TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM)
PLAN MUST ACCOMPANY APPLICATION)
The undersigned hereby applies for a permit to perform the following work and is to comply
with all local ordinances and State of Conn. Building Codes in the performance of such work.
FURTHER DESCRIPTION OF WORK:
STATE LICENSE - NAME & TYPE #DATE SIGNATURE OF AMICANT
j6x- 4DT34
APPROVED E
I - 8 - R CALCULATION SHEET 1503 (Modern Method)Copyright 1971 by The Hydronics Institute
OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE
COL. A COL.&COL.C COL.D COL.E COL.F COL.G
1 ROOM
IC
O H L W H L W H L W H L W H L W Design Water Temp.
2 ROOM DIMENSIONS, FT.
U BTUH per Foot of
3 LENGTH EXPOSED WALLS,FT. t Radiation Selected
a WINDOW AND OUTSIDE DOOR AREA IL
@TUH BTUH TUN STUN STUN
5 WALL CONSTRUCTION
Table 9,Lone 3 x HI ROOM LIN. FT.OF
TOTALS RADIATION
T6 YPE OF GLASS FROM LINE 12 SELECTED
IBottom of table used low Line S)
7 CEILING CONSTRUCTION C
ITable 9.L x W)
e FLOOR CONSTRUCTIONt 0--
ITable 9, L x W or Lin Ft) E
9 COLD PARTITION CONSTRUCTION F
ITable 9.L a H)
G
1O c 1 Wall IWIthOpenings)G
2 Wells lWith Openings) oX H
3 want lwrth Openings)or EntEl
J t
11 70iA1 BTUH AT 70F TEMP DIFFERENCE'J
17 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K
L
COL.A COL.&COL.H COL.1 COL_J _ COL.K COL.L TOTAL BTUH TOTAL
1 ROOM OF &UILDIN RADIATION
E AT SELECTED
O H L W H L W H L W H L W H L W DESIGN TEMP.-
2 ROOM DIMENSIONS. FT I- DIFFERENCE
U
3 LENGTH EXPOSED WALLS, FT.
a WINDOW AND OUTSIDE DOOR AREA IL
STUN @TUH BTU" BTUH BTUH
5 WALL CONSTRUCTION INCREASE BATHROOM
ITable 9,Llne 3 x HI TOTAL20%
6 TYPE OF GLASS
113ottom of table used for Line 51
7 CEILING CONSTRUCTION IFOR CONCRETE FLOOR ON
ITable 9.L W) GROUND OR FILL AT
GRADE LEVEL,USE LINEAR
@ FLOOR CONSTRUCTION? FEET OF EXPOSED EDGE
ITable 9.L x W or Lin Ft 1
9 COLD PARTITION CONSTRUCTION
ITable 9.L x HI
10 c 1 Wail IWlth Open.ngsl O;
2 Wells(With Open.ngsl o X
3 Wens(With Openings) or Ent Hall a
11 TOTAL BTUH AT 7OF TEMP DIFFERENCE*
17 TOTAL BTUH AT DESIGN TEMP DIFFERENCE
This form 16 a.adeble from The MydrOnlcs Institute 36 Russo Place,BukNey Heights,N J 01922 FORM 1503
ti
INSPECTOR DATE -3/-3 TIME
LOCATION
INSPECTION: CODE: ESULT(D/A) :
BUILDING:
ELECTRICAL:
PLUMBING:
HVAC:
N is tf
BOTHER:
1bv