HomeMy WebLinkAbout266 Quarry Brook Drive (3)Y.
r
1 _
T
YJ
r
DEPARTMENT DECISION APPLICATION FOR PER ff#
Application is hereby:TOWN OF SCJ
BUILDING Dom'
Z:APROVED 1540 SULLIVAN f Bidg.Ftrnrit:#
Jam_644-2511 ext.y . ,
ate Building Inspector gip:
FEE SCHEDULE
UO Own
0-$1,000=$15.00 Street No. Lot No.
Over$1,000=
15.00 per$1,000
or any fraction thereof Tenant Designations i .No.
APPLICANT
APPLICANT ADDRESS
APPLICANT PHONE#
V 1
000011111111111 N S OWNER
OWNER ADDRESS
y
OWNER PHONE
C MID ESTIMATED COST$
IS THIS A CONTRACT COST? Y
CFEEENCLOSED$
TYPE OF JOB:
OR-CO New Installation
Alteration/Addition/Repair
a
Revised 4/01//2002
APPLICATION FOR HVAC PERMIT (Continued from reverse side)
TYPE OF SYSTEM: TYPE OF UILDING:
HEATING SIDENTIAL
Q/C COMMERCIAL
VENTILATION INDUSTRIAL
HEATING
STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
HYDRONIC WARM AIR UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
GROSS HEATING CAPACITY(INPUT BTUH) NET RATING(OUTPUT-BTUH)
TYPE OF FUEL
OIL-GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY
GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DES RIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
At- ffand T A 16MA
TONNAGE COOLING CAPACITY(BTUH)
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT 4ze x DATE
Page 1 6/9/2003
Residential Heat Loss and Heat Gain Calculation
In accordance with ACCA Manual J
Registered To: Aiello Plumbing Heating and Air Conditioning
For: Bresciano Fred & Dorothy
266 Quarry Brook Dr
South Windsor, CT. 06074
Design Conditions: Windsor Locks,Bradley Field
Indoor: Outdoor:
Summer temperature: 72 Summer temperature: 95
Winter temperature: 70 Winter temperature: 6
Relative humidity:50 Summer grains of moisture: 93
Daily temperature rangeMedium
Building Component Sensible Latent Total Total
Gain Gain Heat Gain Heat Loss
BTUH) BTUH) BTUH) BTUH)
Whole House 1,504.2 sq.ft. 21,807 2,535 24,342 41,294
2 tons
Lower Level 3,744 1,198 4,942 11,411
Rear Room-- 285 _sq.ft. 3,287-- 991 4_,278 9,094
Foyer 66 sq.ft. 457 207 664 2,317
Lower Level (2)2,674 236 2,910 5,299
Sewing Room 187 sq.ft. 2,674 236 2,910 5,299
First Floor 8,428 551 8,979 13,498
Kitchen 126 sq.ft. 2,551 79 2,630 2,436
Dining Room_120 sq.ft. 2,383 236 2,619 4,612
Living Room 253 sq.ft. 3,494 236 3,730 6,450
Second Floor 6,961 551 7,512 11,088
Master Bedroom 165 sq.ft. 2,796 236 3,032 4,317
Office 99 sq.ft. 1,564 118 1,682 2,590
Hall 45 sq.ft. 102 0 102 164
Bathroom 24 sq.ft. 815 79 894 1,190
Bathroom (2) 35 sq.ft. 300 0 300 757
Bedroom 100 sq.ft. 1,384 118 1,502 2,070
Whole House 1,504.2 sq.ft. 21,807 2,535 24,342 41,294
2 tons
HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101
Load calculations are estimates only,actual loads may vary due to weather and construction differences.