Loading...
HomeMy WebLinkAbout266 Quarry Brook Drive (3)Y. r 1 _ T YJ r DEPARTMENT DECISION APPLICATION FOR PER ff# Application is hereby:TOWN OF SCJ BUILDING Dom' Z:APROVED 1540 SULLIVAN f Bidg.Ftrnrit:# Jam_644-2511 ext.y . , ate Building Inspector gip: FEE SCHEDULE UO Own 0-$1,000=$15.00 Street No. Lot No. Over$1,000= 15.00 per$1,000 or any fraction thereof Tenant Designations i .No. APPLICANT APPLICANT ADDRESS APPLICANT PHONE# V 1 000011111111111 N S OWNER OWNER ADDRESS y OWNER PHONE C MID ESTIMATED COST$ IS THIS A CONTRACT COST? Y CFEEENCLOSED$ TYPE OF JOB: OR-CO New Installation Alteration/Addition/Repair a Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF UILDING: HEATING SIDENTIAL Q/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL OIL-GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DES RIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) At- ffand T A 16MA TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT 4ze x DATE Page 1 6/9/2003 Residential Heat Loss and Heat Gain Calculation In accordance with ACCA Manual J Registered To: Aiello Plumbing Heating and Air Conditioning For: Bresciano Fred & Dorothy 266 Quarry Brook Dr South Windsor, CT. 06074 Design Conditions: Windsor Locks,Bradley Field Indoor: Outdoor: Summer temperature: 72 Summer temperature: 95 Winter temperature: 70 Winter temperature: 6 Relative humidity:50 Summer grains of moisture: 93 Daily temperature rangeMedium Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss BTUH) BTUH) BTUH) BTUH) Whole House 1,504.2 sq.ft. 21,807 2,535 24,342 41,294 2 tons Lower Level 3,744 1,198 4,942 11,411 Rear Room-- 285 _sq.ft. 3,287-- 991 4_,278 9,094 Foyer 66 sq.ft. 457 207 664 2,317 Lower Level (2)2,674 236 2,910 5,299 Sewing Room 187 sq.ft. 2,674 236 2,910 5,299 First Floor 8,428 551 8,979 13,498 Kitchen 126 sq.ft. 2,551 79 2,630 2,436 Dining Room_120 sq.ft. 2,383 236 2,619 4,612 Living Room 253 sq.ft. 3,494 236 3,730 6,450 Second Floor 6,961 551 7,512 11,088 Master Bedroom 165 sq.ft. 2,796 236 3,032 4,317 Office 99 sq.ft. 1,564 118 1,682 2,590 Hall 45 sq.ft. 102 0 102 164 Bathroom 24 sq.ft. 815 79 894 1,190 Bathroom (2) 35 sq.ft. 300 0 300 757 Bedroom 100 sq.ft. 1,384 118 1,502 2,070 Whole House 1,504.2 sq.ft. 21,807 2,535 24,342 41,294 2 tons HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only,actual loads may vary due to weather and construction differences.