Loading...
HomeMy WebLinkAbout2620 Ellington RoadElectric# /7059 APPLICATION FOR BUILDING PERMIT Plumbihg#0 cY61 2 6aO Ellington Road WAC # vt t 1-1 27279 Date: B- /- O o Sp,inkler# No. FNAL APPROVALS Estimated Cost $ o Budd'v COMPLETE RED BOXED AREAS Permit Fee O YU g TYPE OR PRNT ONLY Occupancy Fee $ Affidavit SIGN ON REVERSE SIDE Appr.for CO.Total Fee U TO BULDM DEPARTMENT,TOWN OF SOUTH WNDSOR,CT Additional Cost) $ The undersigned hereby applies to do work oc or ng to the following specifications: Job Location i Lot No. Side of Street Zone Applicant J • C• G.Tel# Address i/Z /emi r 9 1r cc Sore , L,/.;a/c o Zip Lic.# Owner_,f c ,4 , G Address/D '12okint Mod e 4/i 0 e_ C- Architect Address Sy.Ft.New Area: 1st FL 1/1 z( 2nd Fl. g 3 3rd FI. Total New Area Z&% Rooms S Lavatories Bathrooms a Garages 07 Purpose of this permit: moag4-40 I- - City Water 10 Well Septic System A Sewer Ins. H.O. S.P. Cert. Area r y. Basement 0 Garage Approved by Date Z Use Group Construction Type B RevbW 1/97 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building and its use is allowed Lsl.G. G, hc• SignedMa,-AAor— I clrCk=1ems I hereby apply for a Certificate of Occupancy for the wo described in this application for the permit Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Location of Job:AFFIDAVIT Additional Fee$ 2 9 9 .0 0 State of Connecticut ss.South Windsor County of Hartford Owner 1 of Agent for the building erected Contract r under Permit No. 27279 issued by the Building Department of the Town of South being duly sworn,make oath and say that the actual cost of the completed work authorized un s rmit d' t exceed the most current accepted BOCA value of$ 119 , 302 . C Signed Subscribed and sworn to before me this ! day of Estimated Cost S 96r774 . Difference: S 22, 527 . otary Public i Inspection / Approval Date By Appl Code Description Due Whom Code Comment 27279-B 80,000 BO1 FOOTING 12/06/00 JFF A WITH CONTRACTOR WINTER PROTECTION HAY PROVIDE B02 FOUNDATION 12/13/00 CJD D NEED 6MIL POLY TO WATER PROOF FOUND. B02 FOUNDATION 12/18/00 CJD A WATERPROOFING 6MIL-FTG. DRNS. OK P03 ROUGH 07/25/01 JFF A WITH CONTRACTOR B03 FRAMING (ROUGH) 08/03/01 CJD A WILL THROUGH BOLT BEAMS @ KITCHEN, NEED SPEC ON LAMS E03 ROUGH O8/07/01 CJD A ADD KITCH. GFI, LGHT ACTV. @ BOT.CELR.STR RUN FIRE STOPPING H03 ROUGH 08/07/01 CJD A W/CONTRCT. B04 INSULATION O8/09/01 CJD A W/CONTRACTOR E01 SERVICE 08/15/01 GRM A B03 FRAMING (ROUGH) 08/20/01 CJD A CONVERT GARAGE CEILING JOISTS TO HABITABLE FLOOR, BONUS ROOM OK W/ BUILDER(JRC APPRV.SPC B09 OTHER 08/22/01 GRM D CHECK HIP FRAMING FOR SUPPORT OF RIDGE B10 FINAL 09/10/01 CJD D NO ACCESS TO SINK, WALL PLATES MISSING NEED HOUSE #IS, GRADING, DECK B10 FINAL 09/13/01 CJD D FRNT.RAILNG. ,ATTIC LGHT., SEE CORRECT. NOTICE IN STREET FILE 11111-H 10,000 10801-P 5,900 17059-E 875 Total Est Value 96,775 Dwelling 2,029 97,960.12 Basement 1,025 14,555.00 Garage 441 6,262.20 Smoke Det 7 525.00 BOCA Value 119,302.32 q1 ,Difference 22,527.32 Inspection / Approval Date By Appl Code Description Due Whom Code Comment 27279-B 80,000 B01 FOOTING 12/06/00 JFF A WITH CONTRACTOR WINTER PROTECTION HAY PROVIDEB02FOUNDATION12/13/00 CJD D NEED 6MIL POLY TO WATER PROOF FOUND.B02 FOUNDATION 12/18/00 CJD A WATERPROOFING 6MIL-FTG. DRNS. OKP03ROUGH07/25/01 JFF A WITH CONTRACTOR B03 FRAMING (ROUGH) 08/03/01 CJD A WILL THROUGH BOLT BEAMS @ KITCHEN, NEED SPEC ON LAMS E03 ROUGH 08/07/01 CJD A ADD KITCH. GFI, LGHT ACTV. ® BOT.CELR.STR RUN FIRE STOPPINGH03ROUGH08/07/01 CJD A W/CONTRCT. B04 INSULATION 08/09/01 CJD A W/CONTRACTORE01SERVICE08/15/01 GRM A B03 FRAMING (ROUGH) 08/20/01 CJD A CONVERT GARAGE CEILING JOISTS TO HABITABLE FLOOR, BONUS ROOM OK W/ BUILDER(JRC APPRV.SPCB09OTHER08/22/01 GRM D CHECK HIP FRAMING FOR SUPPORT OF RIDGEB10FINAL09/10/01 CJD D NO ACCESS TO SINK, WALL PLATES MISSING NEED HOUSE #IS, GRADING, DECKB10FINAL09/13/01 CJD D FRNT.RAILNG.,ATTIC LGHT., SEE CORRECT. NOTICE IN STREET FILE Inspection / Approval Date By Appl Code Description Due Whom Code Comment 11111-H 10,000 10801-P 5,900 17059-E 875 SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT a r3 p ^LLINGTON ROAD LOT_# Reviewed neerin ) W.C.G. INC.Date Reviewed MAIoa pprove e 112 DEMING STREET,SOUTH WINDSOR,CT Reviewed By nning) BP_#_27279 Ph_##_644-2565 Date Reviewed 0 pprov enied Date Submitted 08/25/00 FO B I D G PE In accordance with the Zoning and/or Subdivision R ul tions, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include: Approved Denied N/A 1. Name, address & phone number of owner/applicant 2. Name, address & phone number of plan preparer 3. Zoning Information - i.e. zone, open space, floodway, street address. 4. Plot Plan at 1" = 40' scale a. Subdivision reference, abutting properties, etc b. Easements of record C. Lot description, bearings, building lines, distances, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate e. Building location with dimensions. Elevations of proposed finish floor, garage floor & centerline of road at driveway f. Elevations of gravity drainage systems, sanitary foundation drain at the house and the street g. Tentative utility location (gas, water, electric, septic system, etc.) h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements. (P.E. & L.S.) 5. Sedimentation and erosion control 6. Special Planning & Zoning, Inland/Wetlands considerations (Plans on file w/Town Clerk) COMMENTS: 46 St/fit QPr d j/ R_ dip Cam'Corssd/'r L SSG i ems 4 s ./'7'ry `C s•s.=/fir=3' 4.s d SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 2620 ELLINGTON ROAD LOT_# 4 Reviewed By 1_ ' Engineering) W.C.G. INC.Date Reviewed iz Zry o Approved/Denied 112 DEMING STREET,SOUTH WINDSOR,CT Reviewed By Planning) BP_# 27279 Ph_##_644-2565 Date Reviewe 61 prove /Denied Date Submitted 00/00/00 IlUclo , FOR C of 0 ***** T As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A i/ 1. Approved building permit plan 2. Finish grading per approved building permit plan 3. Site work; i.e. trees, shrubs, dumpsters, required parking if 4. Utility location; J a. sanitary sewer/septic system b. foundation drain C. electrical & telephone d. water e. other 5. Sewer connection charge paid 6. Appropriate certification 7. Bonding 8. Planning & Zoning/ Inland Wetlands Considerations A. Lighting B. Signage Freestanding Wall C. Fee in lieu of Open Space Sewer Permit No. 4,, ,4 Pavement Excavation No. 01 COMMENTS: DEPA 4TIVIENT DECISION APPLICATIONTION FOR ELECTRICAL PERMIT PERMIT# r Ap cation is hereby:TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit#y iPPROVED 1540 SULLIVAN AVENUE 644-2511 ext.230 Building Inspector Application must be printed or typedf7,{ Location ofjob 27 s Street No. Street Lot No. SCHEDULE Floor 0 1,000 - $12.00 Apt.No. er $1,000 111,00 per S1'000 OWNER G'r •C, fraction thereof y ADDRESS P.x 6 OWNERS PHONE# APPLICANTJL' W N ADDRESS e'y C"t! 4i Al 4;105T_FJ•• J• co) US R: 1 ,•t• 1 ESTIMATED COST$ ,. IS THIS A CONTRACT COST? YES NO FEE ENCLOSED 5 sOR-C0 E OF JOB: V00 Original bnstai66 Alteration/Audition/Repair Revised 11/95 r a. APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL BUILDING PERMIT APPLICATION YES / NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY INSTITUTIONAL FACTORY STORAGE ENGINEER'S NAME PHONE GARAGE MIXED USE ADDRESS CITY STATE ZIP Other please specify) TYPE OF INSTALLATION/WIRING METHOD oMfX SIZE OF MAIN FEEDERS AND RATING OF WIRE USED Y/oA 1,,eW A NUMBER OF METERS GNc NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS Dac REMOTE DISCONNECT REQUIRED 7 YES O NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPERATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK a'W5acI R7,0 yt THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING D S IN THE PERFORMANCE OF SUCH WORK. NAME STATE LICENSE NO. TYPE SIGN TURE CANT a PHONE NO. /' DA l!oa hirley Wilhelm-CPS Approval on irmation: Request No. 181083 Page 1 From: clpsvc@nu.com> To: WILHEL@SOUTHWINDSOR.ORG> Date: 8/20/01 9:49AM Subject: CRS Approval Confirmation: Request No. 181083 CRS Work Request M 181083 House No:2600 (AZ C) Lot No: Street Name: Inspector:JOHN COLLINS Approval Date: Aug 20, 2001 DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereb 0 FBUILDINGDEPARTMENT APPRO 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 7 ` -9 Date ui specto 1 - Application must be printed or typed tr 0 L ation of Job: FEESCHEDULE 0-$1,000=$13.00 eeet-2 Street Lot No. Over$1,000= 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT 4W Ne Road r APPLICANT ADDRESS a s APPLICANT PHONE# OWN S OWNER R q OWNER ADDRESSCI dF Coo) OWNER PHONE A 70 C ESTIMATED COST$ IS THIS A CONTRACT COST? es 13 No 1 FEE ENCLOSED$ TYPE OF JOB: OR-CO W Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATE WITH A BUILDING PERMIT APPLICATION? YES NO SIDENTIAL BUSINESS CURRENT USE AND OCCUPANCY ASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCY EDUCATIONAL INSTITUTIONAL ENGINEER'S NAME PHONE FACTORY STORAGE ADDRESS GARAGE MIXED USE CITY STATE ZIP Other please specify) TYPE OF INSTALLATION SIZE OF MAIN DRAIN L NO.OF TOILETS_ STYLE NO.URINALS STYLE NO.OF BATHTUBS NO.OF SHOWERS NO.OF LAVATORIES NO.OF CONDUCTORS SIZE NO.OF STACKS SIZE J AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW YES NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEVER OR SEPTIC TANK 7 J SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER WATER HEATER: TYPE MANUFACTURER DESCRIPTIOTt OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING T. PERFORMANCfA*8 V6r- STATE OF CT. P1-204770 PI-204T1O iiTT PI 204770 S3-385603 CONTRACT NO. E ST TE SIGNATURE OF APPLICANT DATE C nj r r* `` DEPARTMENT DECISIONY CATION FOR HVAC PERMIT PERMIT# Application is hemby: r TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT APPRO w 777, 1540 SULLIVAN AVENUE Bldg.Permit#e. 644-2511 ext. 230 Application must be printed or typed F g Location of Job:FEES 0-$1,000 S13.00 Street Lot No. S1,QtlI1! tom. ; 13.00 per=$1;000 4oranvfraction s gnation Apt.No. el".1,00L V ADDRESS PHONE 5W- 0* Q DRESS ll2 n-a,w4 4 . C7 ooeo no NE r COST$ /00 G!00 NTRACT COST.Yes 0 No SED$ inal Installation K `sE ration/Addition/Repair Revised 8/99 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: 9 HEATING A RESIDENTIAL A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW TRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE_ll, —°F INSIDE -76 OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) 3- `OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) Al gad.4 GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL la OIL—GPM S GAS—INPUT ELECTRIC—KW OIL TANK SIZE&LOCATION I INSIDE OUTSIDE CAPACITY 2-?75- LPG TANK CAPACITY AIR CONDITIONING 7/ DESIGN TEMP. OUTSIDE OF INSIDE S OF DIFFERENCE /3 OF TOTAL HEAT GAIN(BTUH)2 e) (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) 14 1 1 014RV .R1K`lu r 4 CJ,FiiT ' J •Tk TONNAGE 3 COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK J d/w/a• of L 4-L-Ac: ,4 64017 100, THIKUNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 0-76 37 S-I obof C 771 CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE -7 A Ql S/N 12486 RIGHT-J SHORT FORM 7/12/01 File name: W.C.G. INC 2 Job#: 2 600 ELLINGTON RD S.W. Htg Clg For:W.C.G. INC. Outside db 4 88 P.O.BOX 559 112 DEM ING RD Inside db 70 75 SOUTH WINDSOR CT 06074-0559 Design TD 66 13 6 4 4-2 5 6 5 Daily Range M Inside Humid. 50 By: STAFFORD MECHANICAL SERVICES Grains Water 29 71 C WEST STAFFORD RD Method Simplified STAFFORD SPRINGS CT 06076 Const.glty Average 8 6 0) 6 84-94 8 5 Fireplaces 1 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Model Model Type Type Efficiency/HSPF 0.00 COP/EER/SEER 0.00 Heating Input 0 Btuh Sensible Cooling 0 Btuh Heating Output 0 Btuh Latent Cooling 0 Btuh Heating Temp Rise 0 Deg F Total Cooling 0 Btuh Actual Heating Fan 1289 CFM Actual Cooling Fan 1289 CFM Htg Air Flow Factor 0.020 CFM/Btuh Clg Air Flow Factor 0.053 CFM/Btuh Space Thermostat Load Sensible Heat Ratio 90 ROOM NAME AREA HTG CLG HTG CLG SQ.FT. BTUH BTUH CFM CFM DINING ROOM 178 9189 2803 181 150 KITCHEN/BREAKFAT 312 11661 6372 229 341 FAMILY ROOM 368 14420 4456 283 238 LIVING ROOM 224 8406 3186 165 170 BED/2 192 4188 1481 82 79 BATH 99 1895 696 37 37 MASTER BEDROOM 266 5091 1935 100 104 MASTER BATH 308 5726 1853 113 99 BEDROOM/3 224 4999 1315 98 70 Entire House d 2171 65576 24098 1289 1289 Ventilation Air 0 0 Equip.@ 0.95 RSM 22893 Latent Cooling 2767 TOTALS 2171 65576 25660 1289 1289 MANUAL J:7th Ed.RIGHT-J:V3.0.15