Loading...
HomeMy WebLinkAbout26 Sunrise LaneEler#ric# s• 26 i APPLICATION FOR BUILDING PERMIT C 10,f Plumbing#u,;' SUNRISE LANEWAC # d X Rk 26278 Nt : 7 rqq Sprinkler# FINAL APPROVALS Estimated Cost p DooBuildingi/ 9-0 COMPLETE MD BOXED AREAS Permit Fee menEngineeringTYPEORPRWTONLYOccupancyFee $ sAffidavit SIGN ON REVERSE SWEAppr.for CO.Total Fee o0 TO BUILDM DEPARTMENT,TOWN OFSOUTH WNDSOR,CT Additional Cost) The undersigned h reby applies to do work according to the following specificationx Job Location_ 426 S 4 N ietse ,C Lot No. Side of Street_Zone -2 0 Applicant_ -fM F,yTf t PRt C.Z S =A1 C. Tel.## 6Vy-52 g 9 Address o 0 6 c v. Zip D ri o 7 y Lic.# Owner tAQ a p Address Architect gt%m Q -,b r s i 6^1 Address a S` M£-4 D d try t '. ( Nt So Q. Sq.Ft.N w Area: 1st FL l S t4 S' 2nd FL 9. i % 3 3rd Fl. Total New Area S'o 9 o Rooms_ 1 2 Lavatories Bathrooms y Garages 3 Purpose of this permit: 0"t%-O I.N 4 K 1) Swa r-AMjLY & JA/C1 City Water Cd--Well 0 Septic System Sewer Z-- Ins. H.O._ S.P.______ Cert.9JI FR)r Area 5164 Basement 2 146) Garage 1265ApprovedbyEQ— Date '7 a' Use Group Construction Type SYS Reviad 1197 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this ilding and its use i Ilowed. Signed- vl-/ I hereby apply for a Certificate of Occupancy for the work descri in this application for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Location of Job:AFFIDAVIT Additional Fee$ 16 9. 0 0 State of Connecticut ss.South Windsor County of Hartford Owner 1 '77 L S yl t M-1 Pf7qr of Agent for the building erected Contractor under Permit No. 26278 issued by the Building Department of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the com leted work authorized nder said pe it did not exceed the most current accepted BOCA value of S 2 9 6,8P8 8 . Signed W QZA'W r - Subscribed and sworn to before me this day of A.D.20 GZ) Estimated Cost S 249 ,317 . Difference: $12 ,751 . Notary Public Inspection / Approval Date By Appl Code Description Due Whom Code Comment 99-26278-B 250,000 B01 FOOTING 07/12/99 DCJ A B02 FOUNDATION 07/27/99 DCJ A DAMPPROOFING, LETTER FROM ENG. RE: CLASS A SOILS B05 FIREPLACE/CHIMNEY 11/15/99 DCJ A E01 SERVICE 11/15/99 DCJ A RELEASED TO N.U. B03 FRAMING (ROUGH) 12/23/99 JFF D JOIST HANGERS FIRESTOPPING ANCHOR BOLTS REINSPECT 122799 B03 FRAMING (ROUGH) 12/27/99 DCJ D DRAFTSTOPPING, NAILING OF LVL'S, J. HANGERS LETTER RE: DEAD LOADS FOR GRANITE FLOORS B03 FRAMING (ROUGH) 01/03/00 DCJ A P03 ROUGH 02/08/00 DCJ A PO4 GAS TEST 02/09/00 DCJ A LEFT STICKER E03 ROUGH 02/17/00 JFF A 2ND FLOOR ONLY WITH CONTRACTOR B04 INSULATION 02/25/00 JFF A 2ND FLOOR ONLY E03 ROUGH 02/25/00 JFF A 1ST FLOOR ONLY WITH CONTRACTOR B04 INSULATION 03/01/00 DCJ A 1ST FLOOR ONLY B10 FINAL 11/22/00 CJD D SHT. RCK. UNDER MAIN STAIR, GFI AT KITCHEN CTR. PROTECT PAPER/INSUL.-BONUS RM. ,HOUSE # B10 FINAL 11/29/00 CJD A W/OWNER 10688-H 23,888 10539-P 15,000 99-16544-E 8,000 Total Est Value 296,888 Dwelling 5,164 249,317.92 Basement 2,946 41,833.20 Garage 1,265 17,963.00 Smoke Det 7 525.00 BOCA Value 309,639.12 Difference 12,751.12 3 Inspection / Approval Date By Appl Code Description Due Whom Code Comment 99-26278-B 250,000 B01 FOOTING 07/12/99 DCJ A B02 FOUNDATION 07/27/99 DCJ A DAMPPROOFING, LETTER FROM ENG. RE: CLASS A SOILS B05 FIREPLACE/CHIMNEY 11/15/99 DCJ A E01 SERVICE 11/15/99 DCJ A RELEASED TO N.U. B03 FRAMING (ROUGH) 12/23/99 JFF D JOIST HANGERS FIRESTOPPING ANCHOR BOLTS REINSPECT 122799 B03 FRAMING (ROUGH) 12/27/99 DCJ D DRAFTSTOPPING, NAILING OF LVL'S, J. HANGERS LETTER RE: DEAD LOADS FOR GRANITE FLOORS B03 FRAMING (ROUGH) 01/03/00 DCJ A P03 ROUGH 02/08/00 DCJ A PO4 GAS TEST 02/09/00 DCJ A LEFT STICKER E03 ROUGH 02/17/00 JFF A 2ND FLOOR ONLY WITH CONTRACTOR B04 INSULATION 02/25/00 JFF A 2ND FLOOR ONLY E03 ROUGH 02/25/00 JFF A 1ST FLOOR ONLY WITH CONTRACTOR B04 INSULATION 03/01/00 DCJ A 1ST FLOOR ONLY B10 FINAL 11/22/00 CJD D SHT. RCK. UNDER MAIN STAIR, GFI AT KITCHEN CTR. PROTECT PAPER/INSUL.-BONUS RM.,HOUSE # Inspection / Approval Date By Appl Code Description Due Whom Code Comment B10 FINAL 11/29/00 CJD A W/OWNER B10 FINAL 11/29/00 CJD A CLOSED OUT. 10688-H 23,888 10539-P 15,000 99-16544-E 8,000 SITE COMPLIANCE CHECKLIST vJ1 SnND TOWN of SOUTH WINDSOR, CONNEC.T{ICUT 26 SUNRISE LANE LOT_# 6 Reviewed By d i B & M ENTERPRISES Date Reviewed -1 v A rove e 376 PLEASANT VALLEY RD,SOUTH WINDSOR,C Reviewed By VKT lanning BP_##_26278_ Ph_##_(860)528-5418 Date Reviewed i' J pro cY/Denied Date Submitted 07/01/99 FOR C of O ***** As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan 2. Finish grading per approved building permit plan 3. Site work; i.e. trees, shrubs, dumpsters, required parking 4. Utility location; a. sanitary sewer/septic system iNv @ A b. foundation drain c. electrical & telephone d. water e. other 5. Sewer connection charge paid4g " 6. Appropriate certification 7. Bonding AA7 8. Planning & Zoning/ Inland Wetlands Considerations A. Lighting B. Signage Freestanding Wall C. Fee in lieu of Open Space WV o[ (fi b. - - >1 c Boa,c Sewer Permit No. _7023 AWnJ fSTAMjSj A 6Wr 1 r (. oc.A rI^ aF Pavement Excavation No. Qbyis6J> COMMENTS: DE gwAv SwN(. /Jf.e,>s "T-, 8( ' A sTAVL1'- EP INVACS FdL- sa iTAt(gE t- ASS. CA'LV (w ES APP TQ EnxRv+c. o/ei (vT r- , / TNfs iS cDKt'T, A" &.ASEMbf( wr I ( 7F ZchR , E.AOWCIQE Ap,,.rG i N4 tiJr lKh• Town of South Windsor Engineering Department 1540 Sullivan Avenue South Windsor, Cr 06074 To Whom It May Concern: We, the buyers of Lot # ._also known as P,13 SL3PJ)z t5 F- L located In the Suj,/R1SF- V)Fw Subdivision, in South Windsor, Connecticut on Zoo b this the--,-lay of VM, hereby grant permission to the Town of South Windsor and its agents or assigns, to enter onto above said property for the purpose of completing any and all site work, per Town Specifications such as grading, raking, seeding, driveway, etc. as requested by the South Windsor Engineering Department. ALI BUYER NOTARY My Commission Exp.14ov.30,2002 BUYER December 7, 2000 Requirements for a Certificate of Occupancy at Lot #6 Sunrise Lane Immediate requirements: Silt fence to be installed at the toe of the fill slope. Check dams to be placed at three intervals along the gully at the southern property boundary. Exposed slope to be protected with hay mulch and anchored netting. Long term requirements: Create a drainage swale along the southern property boundary and stabilize with sod. Establish a lawn. NEI' C U cdOQ E 0 :: movCcr a) C CM .E o r Gc 4 o ..00— Ln SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 26 SUNRISE LANE LOT_# 6 Reviewed By S, 'FFP.-JA. — (Engi B & M ENTERPRISES Date Reviewed %1,151oo Approve Denie 376 PLEASANT VALLEY RD,SOUTH WINDSOR,C Reviewed By Planning BP_#_26278 Ph_#_(860)528-5418 Date Reviewed Approved/Deni d Date Submitted 07/01/99 FOR C of O ***** As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan 2. Finish grading per approved building permit plan 3. Site work; i.e. trees, shrubs, dumpsters, required parking 4. Utility location; a. sanitary sewer/septic system l"V e E,AD ,' b. foundation drain c. electrical & telephoneu+,n.T d. water e. other (_G-xs 7 S. Sewer connection charge paid4g4'4' 6. Appropriate certification 7. Bonding 8. Planning & Zoning/ Inland Wetlands Considerations A. Lighting B. Signage Freestanding Wall C. Fee in lieu of Open Space Sewer Permit No. IG23 Pavement Excavation No. COMMENTS: DZAItiA- Z-wA(t NW>-5 to 8rL STl lL12.f/ A[NC r !''K IN VejzT' Fw- ,C)1TAR+ ,EcnJ ARC- s,JC RR C.4 l Tf-.. U+'1/ Sd wj..% 'JYZ " E^x,bC.kl rsA (vT ' 'THIS K cG( -LTA A^ rcA;EJ'1b i .,bI ($ ChRFL F Xuc- YOt. 1247 PAGE 343 EASEMENT AGREEMENT 5597 KNOW YE BY THESE PRESENTS that KENNETH F. CORNEAU and YVONNE M. CORNEAU of South Windsor, Connecticut(collectively the"Grantor")for valuable consideration received to their full satisfaction of ATULKUMAR S.VACHHANI and RENU A.VACHHANI (collectively the"Grantee")do give, grant, bargain, sell and confirm unto the said Atulkumar Vachhani and Renu A.Vachhani, their heirs, successors and assigns forever an easement, as hereinafter particularly described, over, under and upon that portion of Grantors property being particularly bounded and described as follows- Commencing at a point in the westerly line of Sunrise Lane,which point marks the southeasterly comer of Lot 6 and the northeasterly comer of Lot 5, as shown on a certain map or plan entitled "Survey Prepared For: Atulkumar S.Vachhani Across Property of Comeau Sunrise Lane South Windsor, Connecticut Design Professionals, Inc. Civil Engineers. Planners. Surveyors 165 South Satellite Road, South Windsor Connecticut 06074 Easement Map Drawn By RJN Job No: 95-845(5), (6) y .. Checked By: RPM Date 5-22-01 Sheet 1 of 1.0,which map or plan is on file in the office of the South Windsor Town Clerk; thence running in a southerly direction along a line curving to the left having a radius of 55.00' and a length of 18.93'to a point;thence North 6601941"West for a distance of 46.65';thence South 86*44'17"East for a distance of 53.21'to the point and place of beginning (hereinafter referred to as the"Easement Area.") Within the Easement Area,Grantee, their heirs, successors and assigns, at their t sole cost and expense shall have a perpetual right to: y 1. Enter;upon, and to pass and repasC with persons and equipment, for the purpose of locating, installing, maintaining, altering, repairing and replacing all utilities, r including without limitation, electric, cable and telephone), necessary for Grantee's reasonable use of Lot 6 as shown on the map. 2. The parties hereby further agree as follows: A. Grantee shall restore any disturbed portion of the Easement Area as nearly as possible to the condition existing immediately prior to work done by Grantee.CONVEYANCE TAX RECEWED WATE s —LOCAL.s yF:1OOC10AVE1RealEstatelvecchani.sas.wpd 1G WWN CLERK OF SOUTH WJWSOR 3 VOL. 12 411 PAGE 342 5596 RELEASE OF MORTGAGE q' TO ALL PEOPLE TO WHOM THESE PRESENTS SHALL COME,GREETING: KNOW YE,THAT Countrywide Home Loans.Inc.(tka CounMnvide Funding Corporation)does hereby release and discharge a certain o a e-from: DEBORAH E MOLOCKO to THE SAVINGS BANK OF MANCHESTER dated 11/07/1996 and recorded in the LAND Records of the town of SOUTH VANDSOR,County of Hartford and State of Connecticut in Vol.920,at Page 227. IN WITNESS WHEREOF,Countrywide Home Loan..Inc. &a Countrywide Funding Comoration)has hereunto set their hands this 23 day of Augg ,2001. Signed,Sealed and Delivered in the presence of Couna3nadde Home Loans. rnviatCy3 jde Fundin Co oration MonicPCastro Witness Deanna Burns Yaqyo Hosobuchi Assistant Secm Wi ess STATE OF CALIFORNIA SS. DATED 0823/2001 COUNTY OF VENTURA Personally Appeared Deanna_BurnL as aforesaid,Signer of foregoing instrument,and acknowledged the same to be Assistant Secretary and the free act and deed of sai corpo n/partnership.before me. v o Notary li Q u o cc O A.HOWARD U to Commission 0 1235127 Q 4myNotQy Pub is—Callon i0 _ 3 turo County O g ? Comm.tomes Sep 19.3 wpm LL p Y II' v j Mail Recorded Satisfaction To: Doc ID#00031115722005N ul w Z4DEBORAH E MOLOCKO Prepared by: a —u 6 BETTY DR CTC Real Estate Services 1 ~ SOUTH WINDSOR CT 06074 1800 Tapo Canyon Road,MSN SV2-88 Simi Valley,CA 93063 SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 26 SUNRISE LANE LOT_## 6 Reviewed By . Eg.NLn Engineering) B & M ENTERPRISES Date Reviewed rov enied 376 PLEASANT VALLEY RD,SOUTH WINDSOR,C Reviewed By P anning) BP_# 26278 Ph_#_(860)528-5418 Date Reviewe pproved enied Date Submitted 07/01/99 FO BU LDING PE In accordance with the Zoning and/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include: Approved Denied N/A 1. Name, address & phone number of owner/applicant J 2. Name, address & phone number of plan preparer 3. Zoning Information - i.e. zone, open space, floodway, etc. V 4. Plot Plan at 1" = 40' scale a. Subdivision reference, abutting properties, etc b. Easements of record C. Lot description, bearings, building lines, distances, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate e. Building location with dimensions. Elevations of proposed finish floor, garage floor & centerline of road at driveway f. Elevations of gravity drainage systems, sanitary foundation drain at the house and the street g. Tentative utility location (gas, water, electric, septic system, etc.) h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements. (P.E. & L.S.) AV2 5. Sedimentation and erosion control 04 6. Special Planning & Zoning, Inland/Wetlands considerations (Plans on file w/Town Clerk) COMMENTS:is If P J U L: 1 1999 V S0111HV D EN.M ff. NOV. 26,2000 FROM- ACCENT GLASS COMPANY, 1NC, 170 BOX MT DRIVE VERNON,CT. 06066 TO: BUILDING DEPT, SOUTH WIlV'DSOR,CT. 06074 RR 26 SLINRISF,LANE SOUTH WINDSOR,CT. 06074 THIS LETTER IS TO ITNTORM YOU OF THE TYPES OF GLASS AND THE MANUFACTURERS THAT SUPPLIED THIS GLASS FOR THE ABOVE JOB. 1. THE 3/8"CURVED GLASS IS LAMINATED AND THE MANUFACTURER IS DLUBAK CORPORATION, 520 CHESTNUT ST, P.O. BOX 510, BLAIRSVILLE, PA. 15717 2. THE 3/8"FLAT GLASS IS A TEMPERED GLASS,AND IS MANUFACTURED BY AMERICAN FLATGLASS DISTIBUTORS,575 CURRANT ROAD, FALL RIVER,MA. IF YOU HAVE,ANY FURTHER QUESTIONS PLEASE CONTACT ROSS ALLAN AT ACCENT GLASS COMPANY, 860-647-0146. SINCERELY YOURS, 6- z;j-" aww ROSS ALLAlN ACCENT GLASS COMPANY,INC. ITN vv ,6 V r DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PERMIT# Application is hereby:TOWN OF SOUTH WINDSOR ticsBUILDINGDEPARTMENT APP; i1ding D 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 a '7 1? A Inspector Application must be printed or typed FEE SCHEDULE Location ofJob: 0-$1,000=$13.00 Street No. Street Lot No. Over$11000= 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT TC f 6. Q wq j&rA APPLICANT ADDRESS .772 old 04 i APPLICANT PHONE# Q Q 3 1'ZWpo W N St OWNER 6114 ,2 t''l@d •O OWNER ADDRESS lv J 2OWNERPHONE Pill C ESTIMATED COST$gDOO. f V IS THIS A CONTRACT COST? F'Ies 13 No FEE ENCLOSED$ TYPE OF JOB: I soR.Co fpNew Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? YES NO El RESIDENTIAL BUSINESS CURRENT USE AND OCCUPANCY ASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCY EDUCATIONAL INSTITUTIONAL ENGINEER'S NAME PHONE FACTORY STORAGE ADDRESS GARAGE MIXED USE CITY STATE ZIP Other please specify) TYPE OF INSTALLATION/WIRING METHOD k"10 P SIZE OF SERVICE Zd®Gum SIZE OF MAIN CONDUCTORS " Of , U /4 L NUMBER OF METERS 1 NUMBER OF DISCONNECTS AND RATINGS /"290aje5l NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? rES NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS`LICENSE NO. TYPE STATE DATESIGNATUREOFAPPLICANT kE n.aa 'Wy IF''":.lT1VI'aM'Y`-"S''"y a +.T`e" — 5. _''^' —,V... +r-• F' INSPECTOR [ DATE TIME LOCATION 2(0 ynr S, /,4 INSPECTION: CODE: RESULT(D/A) : BUILDING: E: ELECTRICAL: V-0 S N 4 d r PLUMBING: E HVAC: OTHER: l f h DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: 0-5-,3 ok BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 23 0late' ui ng Inspector Application must be printed or typed Location of Job: FEE SCHEDULE 0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT l APPLICANT ADDRESS Z? Sw l Ccn ,L,6 Xt,S V1 yZt CZo Z, z- APPLICANT PHONE# OWN S OWNER q OWNER ADDRESS OWNER PHONE C Sg ESTIMATED COST$ IS THIS A CONTRACT COST? 0 Yes o J FEE ENCLOSED$ f TYPE OF JOB: SOR.CO New Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUELDING IS THIS APPLICATION ASSOCIATED TH A BUILDING PERMIT APPLICATION? YES NO RESIDENTIAL BUSINESS CURRENT USE AND OCCUPANCY ASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCY EDUCATIONAL INSTITUTIONAL ENGINEER'S NAME PHONE FACTORY STORAGE ADDRESS GARAGE MIXED USE CITY STATE ZIP Other please specify) TYPE OF INSTALLATION ..w SIZE OF MAIN DRAIN NO.OF TOILETS STYLE NO.URINALS STYLE NO.OF BATHTUBS NO.OF SHOWERS NO.OF LAVATORIES L NO.OF CONDUCTORS SIZE NO.OF STACKS SIZE AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES KIND_ ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW WYES NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER WATER HEATER: TYPE MANUFACTURER DESCRIPTION OF WORK r Z THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLIC NT DATE ^02 C) DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: fb (p ' yBUILDINGDEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# Z J. 644-2511 ext. 230 a? a- ate Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: l ti T"t S E__ 0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= 13.00 per$1,000 i or any fraction thereof Tenant Designation Apt.No.C i APPLICANT Llc2 c QX - 1 tc ' C r'l t.z c /t- APPLICANT ADDRESS 761 d APPLICANT PHONE# Z 12;99 N S F OWNER T-,Y re 5 oik O j q< OWNER ADDRESS F:y L t OWNER PHONE C ESTIM.ATED COST$ f2?U IS THIS A CONTRACT COST? KYes 13 No r ICJ FEE ENCLOSED$ 3/2 TYPE OF JOB: SOR*CO Xtiew Installation 0 Alteration/Addition/Repair Revised 8/99 1 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM:c--,P TYPE OF BUILDING: HEATING 05-RESIDENTIAL AIC COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE c> OF INSIDE Z?rD OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION)1— DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) Z - TYPE OF FUEL OIL—GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY V.-GAS—INPUT 7,5-D LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING y c, p DESIGN TEMP.OUTSIDE_- 50F INSIDE OF DIFFERENCE -Z Ct' OF c TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE d COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) L FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE d LOT #6 SUNRISE ESTATES HVAC LOAD ANALYSIS for Joftware RHVACRESIDENTIAL AND LIGHT Comciu HVAC LoAm Prepared By: Stephen P.Smith Advanced Heating&Air Conditioning Inc. 701 Nutmeg Rd.North So.Windsor,Ct.06074 860-282-0205 12-13-99 rf'!,• f 'i .' i, `;. y "l y yy, ' tl III' i:Ii •':'I„ 'I i ' ,1' I,, il' ' • it 7 A, lrt Project: Lot#6 Sunrise Estates Company: Advanced Heating&Air Conditioning Inc. Client: B&M Enterprises Representative: Stephen P.Smith Address: P.O. Box 1060 Address: 701 Nutmeg Rd. North City: So. Windsor, Ct. 06074 City: So. Windsor, Ct. 06074 Phone: 644-5288 Phone:860-282-0205 Fax: Fax: 860-528-2949 Comment: Rr,;'i C. I si` Ir -,i ;rrr I,r iv'' r I.,.,,r, •'{,, •r.ir s I, r,`^r` L, ''I 1 MIi , Project Name: Lot#6 Sunrise Estates Reference City: Hartford,Connecticut Daily Temperature Range: Medium Latitude: 41 Degrees Elevation: 19 Feet Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference Winter: 7 N/A N/A 72 N/A Summer 88 73 50% 75 33 Tf Total Building Supply CFM: 3951 CFM per square foot: 0.756 Square feet of room area: 5,230 Square feet per ton: 556.274 Total heating required with outside air. 135,949 Btuh 136.949 MBH Total sensible gain: 86,873 Btuh 91 % Total latent gain:8,665 Btuh 9 % Total cooling required with outside air: 95,538 Btuh 7.962 Tons(based on sensible+ latent) 9.402 Tons(based on 77%sensible capacity) II '1. I'I Calculations Y arebased`on 7th edition Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. I 1!lu nl' Project File Name: B&M LOT 6 SUNRISE Ali 1'•I II I,e' I I! I I I',' ii' I I 1 Outdoor Outdoor Indoor Indoor Grains System 1--- Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference Winter 7 N/A N/A 72 N/A Summer 88 73 50% 75 33 System 2--- Winter. 7 N/A N/A 72 N/A Summer: 88 73 50% 75 33 System 3-- Winter: 7 N/A N/A 72 N/A Summer: 88 73 50% 75 33 li' •Isl, I r,, I i0. I L o4 No. Projection Offset No. Projection Offset 1 3 1 6 0 0 2 5 0 7 0 0 3 4 0.5 8 0 0 4 0 0 9 0 0 5 0 0 10 0 0 Runouts Main Trunk Duct Material:Flexible Duct Galvanized Steel Roughness Factor 0.010000 0.000300 Pressure Drop: 0.1000 in.wg/100 Ft 0.1000 In.wg/100 Ft Minimum Velocity:450.0 Ft./Minute 650.0 Ft./Minute Maximum Velocity: 750.0 Ft./Minute 900.0 Ft./Minute Minimum Height: 0 Inches 0 Inches Maximum Height: 0 Inches 0 Inches 1' Winter Summer Infiltration: 0.900 AC/Hr 0.400 AC/Hr Volume of Conditioned Space: X 55792 Cu.Ft. X 55792 Cu.Ft. 50,213 Cu.Ft./Hr 22,317 Cu.Ft./Hr X 0.0167 X 0.0167 Total Building Infiltration:836.88 CFM 371.9467 CFM Total Building Ventilation: 0 CFM 0 CFM System 1- Infiltration&Ventilation Sensible Gain Multiplier. 14.29 = (1.10 X 1.00 X 13.00 Summer Temp. Difference) Infiltration&Ventilation Latent Gain Multiplier 22.68 = (0.68 X 1.00 X 33.38 Grains Difference) Infiltration&Ventilation Sensible Loss Multiplier: 71.45 = (1.10 X 1.00 X 65.00 Winter Temp. Difference) System 2--- Infiltration&Ventilation Sensible Gain Multiplier 14.29 = (1.10 X 1.00 X 13.00 Summer Temp. Difference) Infiltration&Ventilation Latent Gain Multiplier 22.68 = (0.68 X 1.00 X 33.38 Grains Difference) Infiltration&Ventilation Sensible Loss Multiplier. 71.45 = (1.10 X 1.00 X 65.00 Winter Temp. Difference) yp ru ,!Iit dGi'; T'; Component Area Sen. Lat Sen. Total Description Quan Loss Gain Gain Gain 3D Window Double Pane Low Emit Wood Frame 457 10,724 0 21,745 21,745 12H Wall R-19+ 1/2"Gypsum Board(R-0.5) 467 1,821 0 465 465 16H Ceiling R-38 Insulation 500 845 0 481 481 19D Floor Over Basement/Encl Crawl Hardwood+R-19 500 845 0 0 0 Subtotals for structure: 1,924 14,235 0 22,691 22,691 Active People: 0 0 0 0 0 Inactive People: 0 0 0 0 0 Appliances:0 0 0 0 0 Lighting: 0 0 0 Ductwork: 0 4,991 0 4,729 4,729 Infiltration:Winter CFM: 150.0,Summer CFM:66.7 457 10,718 1,512 953 2,465 Ventilation:Winter CFM:0.0,Summer CFM:0.0 0 0 0 0 0 Sensible Gain Total: 28,373 Temperature Swing Multiplier:X1.00 System Load Totals: 29,944 1,512 28,373 29,885 Supply CFM: 1,291 CFM per square foot: 2.581 Square feet of room area: 500 Square feet per ton: 162.831 Total heating required with outside air. 29,944 Btuh 29.944 MBH Total sensible gain: 28,373 Btuh 95 % Total latent gain: 1,512 Btuh 5 % Total cooling required with outside air: 29,885 Btuh 2.49 Tons(based on sensible+ latent) 3.071 Tons(based on 77%sensible capacity) 11• I ', 1 I I 'i 1 I Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. I it i I.11 IIi fit It I. I.irw v,rri it 1!i it Room Length: 25.0 Feet System Number. I Room Width: 20.0 Feet Zone Number: 1 Area: 500.0 Square Feet Supply Air 1,291 CFM Ceiling Height 20.0 Feet Required Vent.Air 0 CFM Volume: 10,000.0 Cubic Feet Actual Winter Ventilation Air. 0 CFM Number of Registers: 12 of Supply:0 % Runout Air: 108 CFM Actual Summer Ventilation Air 0 CFM Runout Duct Size: 6 Inches of Supply:0 % Runout Air Velocity: 548 Feet/Minute Actual Winter Infiltration Air: 150 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air. 67 CFM alloc. Actual Loss: 0.192 ln.wg/100 Ft. Item Area U- Htg Sen.CIg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain NW-WALL-12H 20 X 20 218 0.060 3.9 850 1.0 0 217 SW-WALL-1 2H 17 X 20 158 0.060 3.9 616 1.0 0 157 NE-WALL-12H 9.2 X 20 91 0.060 3.9 355 1.0 0 91 NW-GLAS-3D 2-P 0-0 S-1 1 00%S 182 0.361 23.5 4,271 43.6 0 7,935 SW-GLAS-3D 2-P 0-0 S-1 (r/oS 182 0.361 23.5 4,271 53.6 0 9,755 NE-GLAS-3D 2-P 0-0 S-1 100%S 93 0.361 23.5 2,182 43.6 0 4,055 UP-CEIL-16H DARK 25 X 20 500 0.026 1.7 845 1.0 0 481 FLOOR-1 9D 20 X 25 500 0.052 1.7 845 0.0 0 0 Subtotals for structure: 1,924 14235 0 22691 Infiltration: Winter 150.0, Summer 66.7: 457 23.453 10,718 2.085 1,512 953 Ductwork: 0.200 4991 0.200 0 4729 Active People:230 lat/per, 300 sen/per 0 0 0 Inactive People: 150 lat/per,250 sen/per 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total.-28373 Temperature Swing Multiplier X1.00 Room Totals: 29,944 1,512 28,373 it II r Ujw tii llT ,2 41P.R i MINE8.1 Room Length: 13.0 Feet System Number. 2 Room Width: 12.0 Feet Zone Number: 1 Area: 156.0 Square Feet Supply Air 311 CFM Ceiling Height: 9.0 Feet Required Vent.Air 0 CFM Volume: 1,404.0 Cubic Feet Actual Winter Ventilation Air. 0 CFM Number of Registers: 3 of Supply:0 % Runout Air: 104 CFM Actual Summer Ventilation Air 0 CFM Runout Duct Size: 6 Inches of Supply:0 % Runout Air Velocity: 529 Feet/Minute Actual Winter Infiltration Air 77 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 34 CFM alloc. Actual Loss: 0.179 ln.wg/100 Ft. Item Area U- Htg Sen.CIg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain NW-WALL-12H 12 X 9 59 0.060 3.9 230 1.0 0 59 SW-WALL-11 2H 13 X 9 63 0.060 3.9 246 1.0 0 63 SE-WALL-12H 7 X 9 63 0.060 3.9 246 1.0 01 63 NW-GLAS-3D 2-P 0-0 S-1 1 00%S 49 0.361 23.5 1,150 43.6 0 2,136 SW-GLAS-3D 2-P 0-0 S-1 O%S 54 0.361 23.5 1,267 53.6 0 2,894 FLOOR-19D 12 X 13 156 0.052 1.7 264 0.0 0 0 Subtotals for structure:444 3403 0 5215 Infiltration: Winter: 77.2, Summer: 34.3: 103 53.563 5,517 4.757 778 490 Ductwork: 0.200 1784 0.200 0 1141 Active People:230 fat/per, 300 sen/per 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total: 6846 Temperature Swing Multiplier: X1.00 Room Totals: 10,704 778 6,846 I i.Ii I il• ,'Ii,'e„ I'I„„IxI; l tIr•I,,.I„I,,I,,„a 41 I, Ii, I,,,I•,I,f'I, 1It" III'r1 I iI'fi: II',', II,. In 1: 1"" IxII,pq" lil, t..,l' ;, I•' 1, „'',,,, ,,.a,. II•,,., Ii^'r RHV4 Pl't 14 t4,:.IjllI t 1`1,;01 1: I...I......... 1"I'l "j:-I I 14, Room Length: 26.0 Feet System Number: 2 Room Width: 12.0 Feet Zone Number. 1 Area: 312.0 Square Feet Supply Air: 168 CFM Ceiling Height: 9.0 Feet Required Vent.Air 0 CFM Volume: 2,808.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 2 of Supply:0 % Runout Air.84 CFM Actual Summer Ventilation Air 0 CFM Runout Duct Size: 5 Inches of Supply:0 % Runout Air Velocity: 618 Feet/Minute Actual Winter Infiltration Air 19 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 9 CFM alloc. Actual Loss: 0.314 In.wg/100 Ft. Item Area U. Htg Sen.CIg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain SW-WALL-12E 9 X 9 55 0.075 4.9 268 1.2 0 68 SW-GLAS-3D 2-P 0-0 S-1 O%S 26 0.361 23.5 610 53.6 0 1,394 FLOOR-1 9D 12 X 26 312 0.052 1.7 527 0.0 0 0 Subtotals for structure: 393 1405 0 1462 Infiltration: Winter. 19.5, Summer 8.7:26 53.577 1,393 4.769 196 124 Ductwork: 0.200 560 0.200 0 617 Active People: 230 lat/per, 300 sen/per: 1 230 300 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 1,200 Lighting: 0 Sensible Gain Total: 3703 Temperature Swing Multiplier: X1.00 Room Totals: 3,358 426 3,703 US. ...... wl' pp"ll-, itNOLwV11"I"11:'Nti[211111"!$1 K Ot1': SITU!,WTI. a 1"01L;1,11-1,17,11,1%. Room Length: 13.0 Feet System Number 2 Room Width: 13.0 Feet Zone Number 1 Area: 169.0 Square Feet Supply Air 119 CFM Ceiling Height: 10.0 Feet Required Vent.Air 0 CFM Volume: 1,690.0 Cubic Feet Actual Winter Ventilation Air. 0 CFM Number of Registers: 2 of Supply:0 % Runout Air.60 CFM Actual Summer Ventilation Air 0 CFM Runout Duct Size: 4 Inches of Supply:0 % Runout Air Velocity: 683 Feet/Minute Actual Winter Infiltration Air. 22 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 10 CFM alloc. Actual Loss: 0.524 In.wg/100 Ft. Item Area U- Htg Sen.CIg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain W-WALL-12H 13 X 10 101 0.060 3.9 394 1.0 0 101 S-WALL-1 2H 13 X 10 130 0.060 3.9 507 1.0 0 129 W-GLAS-3D 2-P 0-0 S-1 O%S 29 0.361 23.5 680 62.6 0 1,815 FLOOR-19D 13 X 13 169 0.052 1.7 286 0.0 0 0 Subtotals for structure:429 1867 0 2045 Infiltration: Winter 21.7, Summer 9.7: 29 53.552 1,553 4.759 219 138 Ductwork: 0.200 684 0.200 0 437 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 fat/per,250 sen1per. 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total: 2620 Temperature SvAng Multiplier X1.00 Room Totals: 4,104 219 2,620 Ti 1.1,1 j11."ILI L%4., I 1 01: I Tel,"Mon, 17,77,11h0 il4.1 IL 1q, NT Ill,I'r,I q 1I'I. ii iij!111:i 1.1,1.11.III i'll: 1 1 46.M I, 1;-1;11 I!Jji Room Length: 13.0 Feet System Number: 2 Room Width: 11.0 Feet Zone Number: 1 Area: 143.0 Square Feet Supply Air:23 CFM Ceiling Height: 9.0 Feet Required Vent.Air.0 CFM Volume: 1,287.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 1 of Supply:0 % Runout Air.23 CFM Actual Summer Ventilation Air. 0 CFM Runout Duct Size: 4 Inches of Supply:0 % Runout Air Velocity: 261* Feet/Minute Actual Winter Infiltration Air: 34 CFM alloc. Design Loss: 0.100 1n.wg/1 00 Ft. Actual Summer Infiltration Air 15 CFM alloc. Actual Loss: 0.079 ln.wg/100 Ft. Runout velocity constraints were not met due to duct schedule limitations. Item Area U_ Htg Sen.CIg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain S -WALL-1 2H 11 X 9 53 0.060 3.9 207 1.0 0 53 S -DOOR-11 E 2.8 X 6.8 19 0.190 12.3 235 3.2 0 60 S -DOOR-11 E 4 X 6.8 27 0.190 12.3 333 3.2 0 85 FLOOR-19D 11 X 13 143 0.052 1.7 242 0.0 0 0 Subtotals for structure: 242 1017 0 198 Infiltration: Winter: 34.5, Summer: 15.3: 46 53.565 2,464 4.761 348 219 Ductwork: 0.200 696 0.200 0 83 Active People-230 lat/per, 300 sen/per. 0 0 0 Inactive People.- 150 lat/per,250 sen/per. 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total: 500 Temperature Swing Multiplier X1.00 Room Totals: 4,177 348 500 it It it I. ii IMM! yyll'i tal, ITHIi 0"vi",I J 77, 1"''. 1 1' ug Iam Room Length: 13.0 Feet System Number. 2 Room Width: 14.0 Feet Zone Number: 1 Area: 182.0 Square Feet Supply Air 98 CFM Ceiling Height 9.0 Feet Required Vent.Air 0 CFM Volume: 1,638.0 Cubic Feet Actual Winter Ventilation Air 0 CFM Number of Registers: 1 of Supply:0 % Runout Air.98 CFM Actual Summer Ventilation Air 0 CFM Runout Duct Size: 6 Inches of Supply:0 % Runout Air Velocity: 501 Feet/Minute Actual Winter Infiltration Air: 16 CFM alloc. Design Loss: 0.100 ln.wg/100 Ft. Actual Summer Infiltration Air: 7 CFM alloc. Actual Loss: 0.161 ln.wg/100 Ft. Item Area U- Htg Sen.CIg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain S-WALL-12H 14 X 9 126 0.060 3.9 491 1.0 0 125 E-WALL-1 2H 13 X 9 95 0.060 3.9 371 1.0 0 95 E -GLAS-3D 2-P 0-0 S-1 O%S 22 0.361 23.5 516 62.6 0 1,377 UP-CEIL-16H DARK 13 X 8 104 0.026 1.7 176 1.0 0 100 FLOOR-19D 14 X 13 182 0.052 1.7 308 0.0 0 0 Subtotals for structure:529 1862 0 1697 Infiltration: Winter 16.5, Summer. 7.3: 22 53.545 1,178 4.773 166 105 Ductwork: 0.200 608 0.200 0 360 Active People: 230 lat/per, 300 sen/per 0 0 0 Inactive People: 150 lat/per,250 sen/per. 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total: 2162 Temperature Swing Multiplier X1.00 Room Totals: 3,648 166 2,162 III V, M P:j or,1iL 11; 1 oNO'NJ! Room Length: 18.0 Feet System Number. 2 Room Width: 14.8 Feet Zone Number: 1 Area: 266.4 Square Feet Supply Air. 130 CFM Ceiling Height: 10.0 Feet Required Vent.Air 0 CFM Volume: 2,664.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 2 of Supply:0 % Runout Air.65 CFM Actual Summer Ventilation Air 0 CFM Runout Duct Size: 5 Inches of Supply:0 % Runout Air Velocity: 478 Feet/Minute Actual Winter Infiltration Air 25 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 11 CFM alloc. Actual Loss- 0.189 In.wg/100 Ft Item Area U- Htg Sen.CIg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain E-WALL-1 2H 14.8 X 10 115 0.060 3.9 448 1.0 0 115 S-WALL-12H 1.8 X 10 18 0.060 3.9 70 1.0 0 18 N-WALL-12H 3 X 10 30 0.060 3.9 117 1.0 0 30 E -GLAS-3D 2-P 0-0 S-1 O%S 33 0.361 23.5 774 62.6 0 2,066 FLOOR-190 14.8 X 18 266 0.052 1.7 450 0.0 0 0 Subtotals for structure: 462 1859 0 2229 Infiltration: Winter: 24.7, Summer: 11.0: 33 53.576 1,768 4.758 249 157 Ductwork: 0.200 725 0.200 0 477 Active People:230 lat/per, 300 sen/per 0 0 0 Inactive People: 150 lattper, 250 sen/per. 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total: 2863 Temperature Swing Multiplier X1.00 Room Totals: 4,352 249 2,863 II:1' 1 I I,,,,,I , ,dill"„ I i' V:Olt iyin II' I.'ri' liilF 1$'11T 11I, ill' t,t111t,"It.ia, I tit 1k h1.r1..iP1w`;;.,1';LO1'.'l H,Q,d!11 J I" f",Jp'q,4;1 AFTER$ Basso Room Length: 35.0 Feet System Number 2 Room Width: 11.3 Feet Zone Number: 1 Area: 395.5 Square Feet Supply Air 87 CFM Ceiling Height: 10.0 Feet Required Vent Air 0 CFM Volume: 3,955.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 1 of Supply:0 % Runout Air.87 CFM Actual Summer Ventilation Air 0 CFM Runout Duct Size: 5 Inches of Supply:0 % Runout Air Velocity: 637 Feet/Minute Actual Winter Infiltration Air. 44 CFM alloc. Design Loss: 0.100 1n.wg/1 00 Ft. Actual Summer Infiltration Air. 20 CFM alloc. Actual Loss: 0.333 ln.wg/100 Ft. Item Area U_ Htg Sen.CIg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain E-WALL-12H 11.3 X 10 54 0.060 3.9 211 1.0 0 54 E-DOOR-1 1 E 6 X 6.8 41 0.190 12.3 506 3.2 0 129 E-GLAS-3D 2-P 0-0 S-1 O%S 18 0.361 23.5 422 62.6 0 1,127 FLOOR-1 9D 11.3 X 35 396 0.052 1.7 669 0.0 0 0 Subtotals for structure:509 1808 0 1310 Infiltration: Winter.44.2,Summer 19.7: 59 53.559 3,160 4.763 446 281 Ductwork: 0.200 994 0.200 0 318 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per,250 sen/per. 0 0 0 Appliances- 0 0 Lighting: 0 Sensible Gain Total: 1909 Temperature Swing Multiplier. X1.00 Room Totals: 5,962 446 1,909 I, .,I, r'I 'I,Y„'u Id ,,,I„ .I, ,y' t.I'I'I, ,,,;I r, ".,I JI'i• 'I.„I11 I'I,I;•I' I ,I;I ',I ''':;II rI, 'I ,I ,II„'I II' i, I,: 'I:11'„I,,,I•°t, ;•I;II'I„I. I' ,I,r i1 i, t IliI. IIII I,V, I' „'ll:'1"I, III, ,Ill:' ,.II„I „1 ,„ .I,II„„r:l"1,r„II, .I.:IJ '4 rr. ryl ',1,II;; I.I, I, ,I ,I, ,I,i.;4 i :I I ,n'I1I,I IY: II, I I;I '1I Ir,. I:'r,l„II :I'l l,l, ,„ lid' I r Ti.I, I•;I'i' I,i1r I,ji,tl'I,"I,•'I r';1',fJ'y: II I,i, I 1 I,I,i,.il, ,r '.iI'l l ,I 1' .I„r„I,, J I I„I„I ,I I, I„ ,I'I I;I II:":J'I'll'r ., ,r I I tI' 1J, I ,I,I„ I1,I I, I,I ,x 'I' ,I' I I,I',I I I ril''I' I, V.I: 1,,,, I 'II ,'I, RRI'11' I'Iil'r tl ,,,,,, I ',,,I I yHI',It I' M I,,,, LIr' r';,II II' , „I.,I .I ,1, ;I: „I,I II' ,I„ I Ilia ,I ,I,. I 'I'I, 'b p"iI'i; is 1.,1:,, ;I',1,„a:'rl1" II .,,, ,,.., I r r'I. r n 4 4IrlI, r I„rI'.I I" r u''I'r r i'4,11 t, III,, I I4 I:'„I 'F', it ;.ti 'I a ill 20.I I 1 ,li II,a I I„II .li I'(i:: ,e' 11„ I„ : 'aii ,1' L tfYlI. I;I. I ,,,P.rI, '{li'1 y„ , Page v 'i '7,'i,l I,.I,•I'. ,I,,,lyl I„I rl,t I't'14 tl;,,il I ,I'I,y,y, II 1 ,,,, i,lj, I, J„'r,,,,;,14: ,r,t',I uY"li' ,.I 'rI"y'' t" J JIp'*r yvl. l 'I''r I"'rI,' I',, IY:uI r,,; I„,,I'lII,I,' h II+Ir.JI:„,,,I6I,u, I•,„: i i„„,I' Ir,, Ir,":,,,IIt',,l,' I': l.l,,h,,l,l;, r, l I, 1„,.;'I1',' I,,;iI,lIlIJtVlq9•.' j'i,j;•IP,I1I I,„ I„i!;lI ial-; I;I6'„ I:;' jiilt, l,,yI j!,,.i,, I ja,:h,;,,a",II,, v I,I,.;I;pIt'8,;'I',;,Iil'l,.;,: I,li.,"j,;J;„ i,,l'•jl;;l' r. lI,„,jIl,'.I,".',I:If,'nj;„„i,;;,'1i' 1I,:,'"t: s'jI:,',l Y I,Il,'l,'.,, 1: l'li„'t,, fpp'i, II', r, II'',I,', l I" Ir,,„LII.,';I(,I'I' II,„ A,,, I,v1,'„,;IrI''rI'I:,'„I,,I.' II, J„'II;,;.r i:„';,, iIl"'j,!:II'II„, I: f p;;', p, A,',',l;,i,,;; I:; I;,;' I'j,'I;I',f„i:'I":';., Ii I;, r,;,. Ii,: i,I6„1PO p O llf :I„9II I' I I„'II,1„rI,1"I1„ ta'r'II'I;iII,I.II.;I'::, I,:',;;hI,I';'I: I I,,1 G,'IIp";TI„1;1'','1'I;,'' ;t ; I'1I;!1'hI t', I:i;l,il,l ; 1 I . r:Ih,'ir:;;l;I' ..I; II1:1';1 i li lii ,i' ;'II'L.;,I„•i'I f II 'III „lo I'1',Idd lr'i I,II+„I, . .,I., ,1,'I,,,,I,'!' I: 11, 1 ' I,,, ,J: .I ;'1,,,'I,II I I' i,I I' I .,I P I, II, II '," tr ,:li le; ,IY rl •; I i, Room Length: 16.3 Feet System Number: 2 Room Width: 14.8 Feet Zone Number. 1 Area: 241.2 Square Feet Supply Air: 164 CFM Ceiling Height: 10.0 Feet Required Vent.Air 0 CFM Volume: 2,412.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 2 of Supply:0 % Runout Air 82 CFM Actual Summer Ventilation Air. 0 CFM Runout Duct Size: 5 Inches of Supply:0 % Runout Air Velocity: 601 Feet/Minute Actual Winter Infiltration Air: 41 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 18 CFM alloc. Actual Loss: 0.297 In.wg/100 Ft. Item Area U- Htg Sen.Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain E-WALL-12H 14.8 X 10 115 0.060 3.9 448 1.0 0 115 N-WALL-12H 16.4 X 10 142 0.060 3.9 554 1.0 0 141 S -WALL-12H 3 X 10 30 0.060 3.9 117 1.0 0 30 E -GLAS-3D 2-P 0-0 S-1 0%S 33 0.361 23.5 774 62.6 0 2,066 N -GLAS-3D 2-P 0-0 S-1 100%S 22 0.361 23.5 516 17.6 0 387 FLOOR-19D 14.8 X 16.3 241 0.052 1.7 407 0.0 0 0 Subtotals for structure: 583 2816 0 2739 Infiltration: Winter:41.2, Summer: 18.3: 55 53.564 2,946 4.764 416 262 Ductwork: 0.200 1152 0.200 0 600 Active People: 230 lat/per, 300 sen/per 0 0 0 Inactive People: 150 lat/per, 250 sen/per. 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total: 3601 Temperature Swing Multiplier: X1.00 Room Totals: 6,914 416 3,601 41 141151.11:1"..."11.'M H.,in10101TARM:111;'11D 11 If.", Room Length: 18.0 Feet System Number 2 Room Width: 14.4 Feet Zone Number: 1 Area: 259.2 Square Feet Supply Air 172 CFM Ceiling Height: 10.0 Feet Required Vent Air 0 CFM Volume: 2,592.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 2 of Supply:0 % Runout Air.86 CFM Actual Summer Ventilation Air 0 CFM Runout Duct Size: 5 Inches of Supply:0 % Runout Air Velocity: 631 Feet/Minute Actual Winter Infiltration Air. 49 CFM alloc. Design Loss: 0.100 In.wg/l 00 Ft. Actual Summer Infiltration Air: 22 CFM alloc. Actual Loss: 0.327 In.wg/100 Ft. Item Area U- Htg Sen.CIg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain N -WALL-12H 14.4 X 10 Ill 0.060 3.9 433 1.0 0 ill W-WALL-12H 11.4 X 10 81 0.060 3.9 316 1.0 0 81 N-GLAS-3D 2-P 0-0 S-1 100%S 33 0.361 23.5 774 17.6 0 581 W-GLAS-3D 2-P 0-0 S-1 O%S 33 0.361 23.5 774 62.6 0 2,066 FLOOR-19D 14.4 X 18 259 0.052 1.7 438 0.0 0 0 Subtotals for structure:517 2735 0 2839 Infiltration: Winter:49.5, Summer 22.0: 66 53.561 3,535 4.758 499 314 Ductwork: 0.200 1254 0.200 0 631 Active People:230 lat/per, 300 sen/per 0 0 0 Inactive People: 150 lat/per,250 sen/per. 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total: 3784 Temperature Swing Multiplier X1.00 Room Totals: 7,524 499 3,784 AwAdvw4O1HtQA` P4ge.22pi"We 0,866th"W TOp. M d j EJ P.-1111 Room Length: 24.0 Feet System Number: 2 Room Width: 8.5 Feet Zone Number. 1 Area: 204.0 Square Feet Supply Air 50 CFM Ceiling Height: 10.0 Feet Required Vent.Air 0 CFM Volume: 2,040.0 Cubic Feet Actual Winter Ventilation Air 0 CFM Number of Registers: 1 of Supply:0 % Runout Air:50 CFM Actual Summer Ventilation Air. 0 CFM Runout Duct Size: 4 Inches of Supply:0 % Runout Air Velocity: 572 Feet/Minute Actual Winter Infiltration Air: 8 CFM alloc. Design Loss: 0.100 1n.wg/1 00 Ft. Actual Summer Infiltration Air: 4 CFM alloc. Actual Loss, 0.369 In.wg/100 Ft. Item Area U_ Htg Sen.Clig Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain N-WALL-1 2H 8.5 X 10 85 0.060 3.9 332 1.0 0 85 E-WALL-12H 10 X 10 89 0.060 3.9 347 1.0 0 89 E -GLAS-3D 2-P 0-0 S-1 O%S 11 0.361 23.5 258 62.6 0 689 FLOOR-1 9D 8.5 X 24 204 0.052 1.7 345 0.0 0 0 Subtotals for structure: 389 1282 0 863 Infiltration: Winter. 8.2, Summer: 3.7: 11 53.545 589 4.727 83 52 Ductwork: 0.200 374 0.200 0 183 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lattper, 250 sen/per 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total: 1098 Temperature Swing Multiplier: X1.00 Room Totals: 2,245 83 1,098 7i INJ 1y i{ir moor Ii r 1 yry1 y t,11..I t I I Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 3D Window Double Pane Low Emit Wood Frame 356 8,353 0 18,240 18,240 11 E Door Metal Urethane Core 18 222 0 57 57 12H Wall R-19+ 1/2"Gypsum Board(R-0.5) 1,685 6,572 0 1,683 1,683 16H Ceiling R-38 Insulation 2,402 4,060 0 2,310 2,310 Subtotals for structure: 4,461 19,207 0 22,290 22,290 Active People: 0 0 0 0 0 Inactive People: 0 0 0 0 0 Appliances:0 0 0 0 0 Lighting: 0 0 0 Ductwork: 0 8,837 0 4,903 4,903 Infiltration: Winter CFM:349.5, Summer CFM: 155.3 374 24,973 3,523 2,221 5,744 Ventilation:Winter CFM:0.0, Summer CFM:0.0 0 0 0 0 0 Sensible Gain Total: 29,414 Temperature Swing Multiplier.X1.00 System Load Totals: 53,017 3,523 29,414 32,937 Supply CFM: 1,338 CFM per square foot 0.557 Square feet of room area: 2,402 Square feet per ton: 754.555 Total heating required with outside air 53,017 Btuh 53.017 MBH Total sensible gain: 29,414 Btuh 89 % Total latent gain: 3,523 Btuh 11 % Total cooling required with outside air: 32,937 Btuh 2.745 Tons(based on sensible+ latent) 3.183 Tons(based on 77%sensible capacity) r II, , ,e Ir „ ;'i i ,li ''l, , pile II I' I'. il'tl ,1''i" ' Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Ri fiii'lill"vik""till W It 1[1.1:11N d I'j I N'!I II-Rji" T M Room Length: 12.0 Feet System Number. 3 Room Width: 13.0 Feet Zone Number. 1 Area: 156.0 Square Feet Supply Air 265 CFM Ceiling Height: 12.0 Feet Required Vent.Air.0 CFM Volume: 1,872.0 Cubic Feet Actual Winter Ventilation Air. 0 CFM Number of Registers: 3 of Supply:0 % Runout Air 88 CFM Actual Summer Ventilation Air 0 CFM Runout Duct Size: 6 Inches of Supply:0 % Runout Air Velocity: 450 Feet/Minute Actual Winter Infiltration Air. 74 CFM alloc. Design Loss: 0.100 In.wg/1 00 Ft. Actual Summer Infiltration Air: 33 CFM alloc. Actual Loss: 0.130 In.wg/100 Ft. Item Area U- Htg Sen.Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain NW-WALL-12H 12 X 12 114 0.060 3.9 445 1.0 0 114 SW-WALL-12H 13 X 12 107 0.060 3.9 417 1.0 0 107 SE-WALL-12H 7 X 12 84 0.060 3.9 328 1.0 0 84 NW-GLAS-3D 2-P 0-0 S-1 100%S 30 0.361 23.5 704 43.6 0 1,308 SW-GLAS-3D 2-P 0-0 S-1 O%S 49 0.361 23.5 1,150 53.6 0 2,626 UP-CEIL-16H DARK 12 X 13 156 0.026 1.7 264 1.0 0 150 Subtotals for structure:540 3308 0 4389 Infiltration: Winter: 73.8, Summer: 32.8: 79 66,772 5,275 5.937 744 469 Ductwork: 0.200 1717 0.200 0 972 Active People:230 lat/per, 300 sen/per. 0 0 0 Inactive People: 150 fat/per, 250 sen/per 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total: 5830 Temperature Swing Multiplier: X1.00 Room Totals: 10,300 744 5,830 I I,,; ,I„ i q, rl,'•II;::'I, r'I ;i'Ir,f i, ,I, I, rl III, , ,,,,I,I' r'''I, ',I,' 'I•I'I',I,,,ti• I ','' ''', II' If`; .!"N, ,: ,T,T f! r ,91;!,' li .il,'I.,. I,[ 7 L[1'I I I,I,I,r, iI.t i ' 'IYIr 4I I' II I i,t I, NI I,r j';;1'•;j!'I I'jil'I I III',;I. II''.1!' I,WI i I''', ,Irt ry}I•T'I" J' II'',;lyr i•I;yl 1,II III F"I! I.II ;hl",,,',I,I. I I !'r„„I r, 'I:I II,I .,I,q'+i,;,l qrl, II!„.I'r,, ''',i;I,I.,I .I I !.r II', 'IHta-pp ':i "I'„I,,,.i,,i' Irl''I,ii';II';r ,III'', r'G I';,,9 II,'b'f I•u';!,I,,j,lull„ ;il,.i 1p l,,,,'u'"I I; I111 :I'I I'I,"II,II„I I.,I I'I Illltl,ll' dd''I. '' i' I'ICI ,r' wt L'-"^ 'Ip4 a 1",ccyyT,; y' t' l''l" y,'p"' 1 0..'IYI' II' I',III i,1''1'' i;I'IlIlfi,,il'I,lt'r;iI'Ih'''r,r'I.,1''I':Ii1l.,„: I•IIIlIr,II,r" Irl,'lu'Ir1.'I I,' I,,!I!'sII,',II,1I,I q,,I„(,'',lI,„lII II,rI,,,,„ v l,.I,,,I,iI„'lIl.IIi1,'.1''11:I1„'6IIf;„,1I,,ffI,;,'I;I',;Ir,l' p',l'Ifd,In';'li',„Iyrp;;I l„j fJ, 5I,r.r4,I II,{South, iii„ r II",I,,,,,.'I'I:;,",lIi',IiI.,lIl,f,I,''!I,:!I",i•,rf,,II'I'lI'„,I.II,i•1,l1,Ir",,I III,'J.,,rI,,II,.,,iI.'II',`r,l,y1.„I1Itn's',1is'i1IrtJ".II'II:,,'1•iM„;LII f;'I,'I,I,1I„,'lI1;yI'Ii hI I' •, iI„I'IY, I I ii I I' I I. I"24 i'r, i;ll iti' I I 'lil; ;Il I';•'I II':;'i'I u., II'.I; I, „I,. ',i;l,l,l,l,.,l,,,l I I,il..',I„I,I;;i'I';II,I ll,l.ii°li'll' ,;Illi:!II, i;s',I„Ild; Il I;;"I,'Ilph;i;t;l„ ;II II F,j tl,,l I. Ili,l" {1 J'I"fi'' 'ilyi I•Ilrfirr}} L•'ll.,rra.,l•,a ,. .il' III,, .;1,,.4'{Ii'i;l, I h,I' iii''aa,,,• ,,j'i,IIf I. ,r, r i,l,. .;1;11`11. `IiIJ, 'I„bit4It,,.1.1;1,'1' !,ry ',I'I,a ,,,, ;,I ,Y,'1•lI'I il' I '..,I.I,'L' wl I, i"I' ,II a,; !'1„ "i' Y ,I n11,l ll;d, ,,,1„ rill `nl l Pl,IIrl,''""r, ',I Irl'{,y I!{.I II;'I rl'I'I i'!',!"I h'I'Ir,!II. I'" Iti' !I,'il111611' l''" ' „;I,rfll";lr,i'!,I IfMI yl''^rr r',,II"",I,';,,I j,'.I' 'II'SI:I,Inrl I ,,II",,I•i`; l-' ,, , n I ''I I .I,I,:i' d, ,I,. 11 ,I, IF,I .I' I I I •I.. I"1''I gull, !. II„il,1li,l„IwII,I„y II'I.',1'r{, I;1ll' YI,'!r;,l•I n, 4,,.,rl,,,hlii'i,,,,+1,;,r II:,,L, ,,. 1 4Y,;rr,1, '„ „ of ,,ir;; Jl I 1,'I ur, :Qrl,:,q u rlr Room Length: 16.5 Feet System Number: 3 Room Width: 20.5 Feet Zone Number: 1 Area: 338.3 Square Feet Supply Air: 138 CFM Ceiling Height: 9.0 Feet Required Vent.Air 0 CFM Volume: 3,044.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 2 of Supply:0 % Runout Air:69 CFM Actual Summer Ventilation Air 0 CFM Runout Duct Size: 5 Inches of Supply:0 % Runout Air Velocity: 508 Feet/Minute Actual Winter Infiltration Air. 34 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 15 CFM alloc. Actual Loss: 0.213 In.wg/100 Ft. Item Area U- Htg Sen.Clg Latent Sen. Description Quantity Value_ HTM Loss HTM Gain Gain SW-WALL-12H 11.5 X 9 68 0.060 3.9 265 1.0 0 68 SW-GLAS-3D 2-P 0-0 S-1 0%S 36 0.361 23.5 845 53.6 0 1,930 UP-CEIL-16H DARK 16.5 X 20.5 338 0.026 1.7 571 1.0 0 325 Subtotals for structure: 442 1681 0 2323 Infiltration: Winter. 33.6, Summer 15.0: 36 66.778 2,404 5.944 339 214 Ductwork: 0.200 817 0.200 0 507 Active People:230 lat/per, 300 sen/per. 0 0 0 Inactive People: 150 lat/per, 250 sen/per: 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total: 3044 Temperature Swing Multiplier: X1.00 Room Totals: 4,902 339 3,044 Sb N." r. 11iv Ii J!.j 1 1 1 1,1110,1"1" ill,Ul Ill)"11 KIM 1!1:1!:j'. jyif 111,15-1:111101,11:1: WIT IN Mad,11-1;1" 11414-:1 A!TV:0. IM 411[ fli j",:4::, Room Length: 30.0 Feet System Number: 3 Room Width: 13.0 Feet Zone Number: 1 Area: 390.0 Square Feet Supply Air 222 CFM Ceiling Height: 9.0 Feet Required Vent.Air 0 CFM Volume: 3,510.0 Cubic Feet Actual Winter Ventilation Air 0 CFM Number of Registers: 3 of Supply:0 % Runout Air.74 CFM Actual Summer Ventilation Air 0 CFM Runout Duct Size: 5 Inches of Supply:0 % Runout Air Velocity: 544 Feet/Minute Actual Winter Infiltration Air 62 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 27 CFM alloc. Actual Loss: 0.244 ln.wg/100 Ft Item Area U- Htg Sen.CIg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain S-WALL-12H 30 X 9 246 0.060 3.9 959 1.0 0 245 W-WALL-1 2H 13 X 9 75 0.060 3.9 293 1.0 0 75 E-WALL-12H 13 X 9 117 0.060 3.9 456 1.0 0 117 S -DOOR-1 1 E 2.8 X 6.5 18 0.190 12.3 222 3.2 0 57 W-GLAS-3D 2-P 0-0 S-1 O%S 30 0.361 23.5 704 62.6 0 1,878 S-GLAS-3D 2-P 0-0 S-1 O%S 6 0.361 23.5 141 30.7 0 184 W-GLAS-3D 2-P 0-0 S-1 O%S 12 0.361 23.5 282 62.6 0 751 UP-CEIL-16H DARK 30 X 13 390 0.026 1.7 659 1.0 0 375 Subtotals for structure:894 3716 0 3682 Infiltration: Winter.61.7, Summer 27.4: 66 66.773 4,407 5.939 622 392 Ductwork: 0.200 1625 0.200 0 815 Active People:230 fat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per,250 sen/per 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total: 4889 Temperature Swing Multiplier X1.00 Room Totals: 9,748 622 4,889 tillIOU,Ig I T MOP1911"'i I.RN I i 11 1 a kllnoll: ,VW1000 1001 A i ji :11 1 1 1 i f 1'1.W- i F11V4N)buth,WlIhop, w1.1: I Y 1 T j I 1-1 14 1111 1i1iI"-!1 11:1ki'l 111.11-111 11"1 i1,,:Jill Ylftoij 7.-17-77-717-4 Nil 1:N11111IR1141,1 Room Length: 22.0 Feet System Number 3 Room Width: 14.0 Feet Zone Number: 1 Area: 308.0 Square Feet Supply Air:85 CFM Ceiling Height: 9.0 Feet Required Vent.Air.0 CFM Volume: 2,772.0 Cubic Feet Actual Winter Ventilation Air: 0 CFM Number of Registers: 1 of Supply:0 % Runout Air.85 CFM Actual Summer Ventilation Air 0 CFM Runout Duct Size: 5 Inches of Supply:0 % Runout Air Velocity: 622 Feet/Minute Actual Winter Infiltration Air: 15 CFM alloc. Design Loss: 0.100 1 n.wg/1 00 Ft. Actual Summer Infiltration Air: 7 CFM alloc. Actual Loss: 0.318 ln.wg/100 Ft. Item Area U- Htg Sen.Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain E -WALL-12H 12 X 9 92 0.060 3.9 359 1.0 0 92 S-WALL-12H 7.5 X 9 68 0.060 3.9 265 1.0 0 68 E -GLAS-3D 2-P 0-0 S-1 O%S 16 0.361 23.5 375 62.6 0 1,002 UP-CEIL-16H DARK 22 X 14 308 0.026 1.7 521 1.0 0 296 Subtotals for structure: 484 1520 0 1458 Infiltration: Winter: 15.0, Summer.6.6:16 66.750 1,068 5.938 151 95 Ductwork: 0.200 518 0.200 0 311 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat/per,250 sen/per 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total: 1864 Temperature Swing Multiplier. X1.00 Room Totals: 3,106 151 1,864 lop,11pl"ti tl.4pl I yy,,i;Nll tl, ,1 I :I ' a, ,. I IS 1' 'Ifl,1'f YiI Il i'..Ni. J' NI4l.i, al. dl'llirn'qr1 tli I. I x 1. 1iI,y}. il'It h'•iJ"'', t,,b' 1tb I I a'i^I II 'Itlr,l.l.l.l'r Id1 h'77 "b:f;ltj 1 T' Room Length: 36.0 Feet System Number: 3 Room Width: 12.0 Feet Zone Number 1 Area: 432.0 Square Feet Supply Air. 173 CFM Ceiling Height: 10.0 Feet Required Vent.Air 0 CFM Volume: 4,320.0 Cubic Feet Actual Winter Ventilation Air. 0 CFM Number of Registers: 2 of Supply:0 % Runout Air.86 CFM Actual Summer Ventilation Air 0 CFM Runout Duct Size: 5 Inches of Supply:0 % Runout Air Velocity: 634 Feet/Minute Actual Winter Infiltration Air. 36 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 16 CFM alloc. Actual Loss: 0.331 In.wg/100 Ft. Item Area U- Htg Sen.Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain E-WALL-12H 12 X 10 81 0.060 3.9 316 1.0 0 81 E-GLAS-3D 2-P 0-0 S-1 0%S 39 0.361 23.5 915 62.6 0 2,441 UP-CEIL-16H DARK 36 X 12 432 0.026 1.7 730 1.0 0 416 Subtotals for structure:552 1961 0 2938 Infiltration: Winter. 36.4, Summer: 16.2: 39 66.769 2,604 5.923 367 231 Ductwork: 0.200 913 0.200 0 634 Active People:230 lat/per, 300 sen/per. 0 0 0 Inactive People: 150 lat/per,250 sen/per: 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total: 3803 Temperature Swing Multiplier X1.00 Room Totals: 5,478 367 3,803 1. p II I. Iit40t ti 11"Iil "'till ij,111171111 I C 1.1 I'lid lu 11IThiRl All mj j'pY,!j Room Length: 16.0 Feet System Number. 3 Room Width: 14.0 Feet Zone Number: 1 Area: 224.0 Square Feet Supply Air. 175 CFM Ceiling Height: 10.0 Feet Required Vent.Air 0 CFM Volume: 2,240.0 Cubic Feet Actual Winter Ventilation Air. 0 CFM Number of Registers: 2 of Supply:0 % Runout Air:88 CFM Actual Summer Ventilation Air. 0 CFM Runout Duct Size: 5 Inches of Supply:0 % Runout Air Velocity: 643 Feet/Minute Actual Winter Infiltration Air. 50 CFM alloc. Design Loss: 0.100 ln.wg/100 Ft. Actual Summer Infiltration Air: 22 CFM alloc. Actual Loss: 0.340 In.wg/1 00 Ft. Item Area U- Htg Sen.CIg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain E -WALL-12H 14 X 10 107 0.060 3.9 417 1.0 0 107 N -WALL-12H 16 X 10 140 0.060 3.9 546 1.0 0 139 S-WALL-12H 2 X 10 20 0.060 3.9 78 1.0 0 20 E -GLAS-3D 2-P 0-0 S-1 O%S 33 0.361 23.5 774 62.6 0 2,066 N -GLAS-3D 2-P 0-0 S-1 1 00%S 20 0.361 23.5 469 17.6 0 352 UP-CEIL-16H DARK 16 X 14 224 0.026 1.7 379 1.0 0 215 Subtotals for structure: 544 2663 0 2899 Infiltration: Winter: 49.5, Summer: 22.0: 53 66.774 3,539 5.943 499 315 Ductwork: 0.200 1240 0.200 0 643 Active People: 230 lat/per, 300 sen/per: 0 0 0 Inactive People: 150 lat(per,250 sen/per: 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total: 3857 Temperature Swing Multiplier X1.00 Room Totals: 7,442 499 3,857 il•i 1' ;I, , If' 7, YI,.II„ ,J d , , i i I, ;• y IjI, .i m'iG,,, ,,, ; ,f' i, i, i.;,, 'Ir t,; Ir ;,tl,, „r.•;','=''.I n, le NI I' I',' 1! I, i i,lil lIi,l' I' ' I' 1 i,lIl,' I" i i,l iiI'I, ' i! 1 Il, II, I'I ; i.' I '*,i,C.;,l,;'r',!i';il.,il','awl„'lld, i•: 1'. l„I' i,Il,M,I„7,"',N„I;L';' r: YLl)ir.I„ rSI"lI'b1; I• 5,Y,` Y,! r'^ nIi, I i+ t,iw,.lFP.i l,,'u,„w, I,i, I.;CiI`M;,,II,'II N1nManA:;;F il,I II, i.'il l "1 J 1 1 a"GlNi' liflly is II ,I ' il' .I I 97r, Yr ,IiMriy;tY.IN*IdyYi.ln• III; Room Length: 24.0 Feet System Number 3 Room Width: 9.3 Feet Zone Number: 1 Area: 223.2 Square Feet Supply Air.81 CFM Ceiling Height: 10.0 Feet Required Vent.Air 0 CFM Volume: 2,232.0 Cubic Feet Actual Winter Ventilation Air 0 CFM Number of Registers: 1 of Supply:0 % Runout Air.81 CFM Actual Summer Ventilation Air 0 CFM Runout Duct Size: 5 Inches of Supply:0 % Runout Air Velocity: 596 Feet/Minute Actual Winter infiltration Air. 15 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air. 7 CFM alloc. Actual Loss: 0.292 In.wg/1 00 Ft. Item Area U- Htg Sen.Clg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain N-WALL-12H 9.3 X 10 93 0.060 3.9 363 1.0 0 93 E-WALL-12H 10 X 10 84 0.060 3.9 328 1.0 0 84 E-GLAS-3D 2-P 0-0 S-1 0%S 16 0.361 23.5 375 62.6 0 1,002 UP-CEIL-16H DARK 24 X 9.3 223 0.026 1.7 377 1.0 0 215 Subtotals for structure:416 1443 0 1394 Infiltration: Winter 15.0, Summer.6.6:16 66.750 1,068 5.938 151 95 Ductwork: 0.200 502 0.200 0 298 Active People: 230 laUper, 300 sen/per: 0 0 0 Inactive People: 150 lat/per,250 sen/per 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total: 1787 Temperature Swing Multiplier X1.00 Room Totals: 3,013 151 1,787 FtHIJ liltAd Wh WJhhh", i ,I il',6,i ,,,li, ',I.I,ii'i, el;ln I, I';,I. 'I: „I,'ll l' li it I,, ,4'! p,l;'j I I I I1;1,,, II , ,,I I'II il'I 'I I,i j!.j'jj1:114!lj'I'l 1: .1,I'llilt ltl'i,„„I',i N J'N'jN14.,1.1,J 1,. "I hNDetailied wN!NA Ay Room Length: 24.0 Feet System Number: 3 Room Width- 13.8 Feet Zone Number: 1 Area: 331.2 Square Feet Supply Air 197 CFM Ceiling Height: 10.0 Feet Required Vent.Air 0 CFM Volume: 3,312.0 Cubic Feet Actual Winter Ventilation Air. 0 CFM Number of Registers: 2 of Supply:0 % Runout Air:99 CFM Actual Summer Ventilation Air 0 CFM Runout Duct Size: 6 Inches of Supply:0 % Runout Air Velocity: 503 Feet/Minute Actual Winter Infiltration Air: 64 CFM alloc. Design Loss: 0.100 In.wg/100 Ft. Actual Summer Infiltration Air: 29 CFM alloc. Actual Loss: 0.162 In.wg/100 Ft. Item Area U_ Htg Sen.CIg Latent Sen. Description Quantity Value HTM Loss HTM Gain Gain N-WALL-1 2H 13.8 X 10 102 0.060 3.9 398 1.0 0 102 W-WALL-12H 12 X 10 87 0.060 3.9 339 1.0 0 87 N -GLAS-3D 2-P 0-0 S-1 100%S 36 0.361 23.5 845 17.6 0 634 W-GLAS-3D 2-P 0-0 S-1 O%S 33 0.361 23.5 774 62.6 0 2,066 UP-CEIL-16H DARK 24 X 13.8 331 0.026 1.7 559 1.0 0 318 Subtotals for structure: 589 2915 0 3207 Infiltration: Winter: 64.5, Summer: 28.7: 69 66.783 4,608 5.942 650 410 Ductwork: 0.200 1505 0.200 0 723 Active People:230 fat/per, 300 sen/per 0 0 0 Inactive People: 150 lat/per,250 sen/per 0 0 0 Appliances: 0 0 Lighting: 0 Sensible Gain Total: 4340 Temperature Swing Multiplier X1.00 Room Totals: 9,028 650 4,340 7-20-1999 4:42PM FROM C WELTI ASSOC 203 657 2514 P• 1 DR. CLARENCE WELTI, P.E., P.C. GEOTECHNICAL ENGINEERING 227 Williams Street * P.O. Box 397 Glastonbury,CT 08Q.'i3 July 20, 1999 8W)6U.4623!FAX(660)657-2514 Mr. Brian Edwards 13&M Construction Fax 644-7525 Re: Soils beneath Foundations at CoWns Crossing; South Windsor,CT, Dear Brian: Regarding the above the soils at the subject site fall in Class A and are generally sands with relatively high permeability and a water table for most of the area at least 10 feet below footings. Based on descriptions in sections 1813.5.1 and 1813.5.3 in she building code this would exclude any dedicated drainage system. laamp proofing is however normally recommended, as are footing drains. Very tru ours. Ely C s WL arence Welti,PhD,P.E. es.Dr. Clarence Welti,P. E.,P.C. h M 20 t 5 r 02/15/00 TUE 12:28 FAX Architectural Fireplaces 10002 LA-e ohs elcd=@ DA_6 SL)/J8Sg, IE, 7*vfdwxwm infimpl= Q. Temirad n. Vent tOrMlMaUn MW not be recessed In the wall or Aiding. Siding may be brought to the edge d the cap boss. Install the cap as shown in Foiro 1j. Cap pipe sealon$ ShOUM overlap the vent pipe by 11/2 inches. Caulk outside edges of OW, Local codes may require the installation of a shW6(CS) which prevents the a*from accidentally touching anything or anyone. F1WrV 14 Mkistrates cap locations Prescribed by current ANSI Z273.1 and CANICOA-51 49 ln$tWI&tjon Cod". AIN. P"b" M T-7 A AT QWM MMEA W g ONure14-Taft.M., tions Clem ly inlet-6 fact(1.8 A Clearance above veranda.Porch, M)MinIMUM. dank,or balcony- am)MI"Imum. Clearance abovet a&or paved drive-it9Clearancetowil t may be opened-9 way located on pumc"0 7 feet(2.1 M)mini. Inch"(so am)m Inch minimum In mum. Use of a this diwwnslan to Conods),as low an 12 Inch Clearance under vera* rch de*,or balcony-Ar C w cisarancato pormwe --ad window-12 inch- as(30 cm)minimum. IM.nded to prevent 12 Inches(30 an)mlri fain. wndeneatlom on window. A vent must not termMism y above a sidewalk w Vertical clearance to venti soffit located above or paved driveway which i boated between two sin- fine WMSI within a horizontal distance of 2 log(60 gle family dwellings and serves both dweNings. cm)from the center-line of the terminal-18 Inchiss Only permitted if veranda,porch dock,or behmny is 40 cin)min mum.fully open on a minimum of 2 sides beneath the E* w Clearance to urwonlileted soffit-12 Inch"(30 am) floor. minimum. As specified in Installation Codes. Note: Local F w Clearance to outside oomor-v IljoItog to usM. codes of regulations may require diffeteM clear- 0 - C4*&&=to inside comer-6 Inolhos as Noted. antes_ n Not to be Installed above a motoriNgulator usem- Distarics required for vinyl Will materials-so Inch- bly within 3 fog(90 cm)horizontally from the am- es(76 am)minknum, lar4lm of the regulator. Distance required for vinyl soft materials with the 10 Clearwo to service regulator vent outlet-6 I'm use of a vinyl soffit shM-is Indhes(46 am)Wril- I A M)mK MVM. J Clearance to non~anloal Ave supply inlet to AS specified in COA 8149 Installation Cgdn(1991). building or the corr6uslion air Inlet to any other Now: Local Codes or Reaftlong may require df- opplance-12 kw*w PC oar)minknum. forent clearances. 6-98 94 28467C September 1,2000 To Whom It May Concern, Please note that Jay Gauthier Plumbing and Heating LLC is no longer doing work at Lot#6 Q( Sunrise Lane. The job was completed by us as far as the rough-in only. All finish work will be done by another contractor. We wish to cancel our permit and make sure that the new contractor is not doing work under our permit.Thank you for your consideration in this matter. e e y, y Gauthier DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PERMIT Application is hereby: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit# APPROVED 1540 SULLIVAN AVENUE 7—Z 644-2511 ext.230 AA Date Buil g I Spector Application must be printed or typed Location ofjob Street No. Street Lot No. FEE SCHEDULE I Floor Apt.No. f 0 - $1,000 - $4,Q0`,,n Over $1,000 12.00 per$1,000 OWNER 1 C44 or any fraction thereof ADDRESS U C4 -lf e- Q0 OWNERS PHONE# APPLICANT CURRENT ELECTRIC INC. OW N g ADDRESS 332 Old Marlborough Tpke. I Jok ESTIMATED COST$ IS THIS A CONTRACT COST? NO Akw FEE ENCLOSED $ Z&' D® OR-Co TYPE OF JOB: Original Installation Alteration/Addition/Repair Revised 11/95 I i APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A Ix RESIDENTIAL BUILDING PERMIT APPLICATION YES / NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY INSTITUTIONAL FACTORY STORAGE ENGINEER'S NAME PHONE GARAGE MIXED USE ADDRESS CITY STATE ZIP Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF MAIN FEEDERS AND RATING OF WIRE USED NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS -0 NUMBER OF PANELS 2- REMOTE DISCONNECT REQUIRED?-)XS/NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPERATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK 1 d-C_ boo o Qa Aea4tf-aV THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN PERFORMANCE OF SUCH WORK. NAME STATE LICENSE NO. TYPE SI TURE OF APPLICANT PHONE NO.L ZL?! DATE J Shirley Wilhelm-CRS Approval Confirmation: Request No. 182765 Page 1 From: clpsvc@nu.com> To: WILHEL@SOUTHWINDSOR.ORG> Date: 8/15/01 2:38PM Subject: CRS Approval Confirmation: Request No. 182765 CRS Work Request M 182765 House No:26 Lot No: 6 Street Name: Inspector:JOHN COLLINS Approval Date: Aug 15,2001