Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
26 Hunter Drive
Bectric# APPLICATION FOR BUILDING PERMIT Plumbing# 26 HUNTER DRIVE HVAC # V100NUATIUDI ONLY No. 24562 Date' -Ah Sprinkler# FINAL APPROV Estimated Cost S Building L COMPLE::D BOXED AREAS Permit Fee E"g'" ' TYPE PRINT ONLY Occupancy Fee idavitSIGN V o®Appr.for CO. ETotal Fee 4& TO BUILDING DEPARTMENT,TOWN OF SOUTH WI`4DSOR,CT itional Cost) $ The undersigned hereby applies to do work according to the following specifications: Job Location 26 Hunter Drive Lot No. ! Side of Street Zone SJ? Applicant k Tel# 4 1l'tf,Sz Pet Addr ss r>4 e Zip Duo 7{ Lic# Own r Address 4 ooeV4 VQ _ Architect Address Sq. Ft.N w Area: 1st FL 2nd Fl. 3rd Fl. Total New Area —Z2 . Rooms 14 Lavatories Bathrooms 2 Garages / Purpose of this permit:_Z,;yleA- e City Water Well Septic System Sewer RL.., Ins. H.O. S.P. Cert.v Area Basement Garage Approved by(( Date f Q Use Group Construction Type RevbW 1197 F I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building and its flowed. Signed I hereby apply for a Certificate of Occupancy for the work described in this application for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Inspection / Approval Date By Appl Code Description Due Whom Code Comment 97-24562-B 5,000 B01 FOOTING 08/12/97 JFF A B02 FOUNDATION 08/25/97 JFH A Total Est Value 5,000 Electric#11411,43 APPLICATION FOR BUILDING PERMIT Plumbing# l O a 14Z 2 6 HUNTER DRIVE HvAc # 1 r-ak Dat : -Zo7q Sprinkler# NO. 24788 FINAL APPROV Estimated Cost ODO Building COMPLETE RED BOXED AREAS Permit Fee 600 Engineering ETYPE OR PRINT ONLY Occupancy Fee $ S Affidavit 1 SIGN ON REVERSE SIDE Appr.for CO. It q Total Fee G TO BULDIN DEPARTMENT,TOWN OF SOUTH WI DSOR,CTTO Cost) l o The undersigned hereby applies to do work according to the following specifications:, Job Location a? AL ,Lot No. Side of Street Zone -S-e D Applicant rd,+ ill Tel# 6 VV—S2 * Addr ss 7 Zip Lic.# Owner Address Architect 63 n6r3A-L Address Sq.Ft.New Area: 1st FL 1.23D 2nd Fl. 3rd Fl. Total New Area /a 30 Rooms Il Lavatories Bathrooms cl Garages I Purpose of this permit: C Of;7— I r, h)a'rL13 P City Water Well Septic System Sewer fa/ Ins. H.O. S.P. Cart. Area I Z V Basement Z a G3arage .26 1-1 Approved by Date Use Croup Construction Type 6 R*YbW 1/97 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances ofthe Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building and tp use is allowed. Signed Af' I hereby apply for a Certificate of Occupancy for the work dp5ribed in this application for the permit. Signed 146=- DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Location of Job: AFFIDAVIT Additional Fee'S 14 4 . 0 0 State of Connecticut ss. South Windsor- County of Hartford Owner of 1-h-E /L ("prArent for the building erected Contractor under Permit No. 2 4 7 8 8/2 4 5 6 2 issued by the Building Department of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized under said permit did not exceed the most current accepted BOCA value of S 7 8 . 4 0 2 . 0 0. ff I L C Signed Subcribed and sworn to before me this day of A.D. 19_1Z Estimated Costs 66, 600. 00 Difference: S 11 , 8 02 . 00 otary PubliC.eJCIL 3 Inspection / Approval Date By Appl Code Description Due Whom Code Comment 97-24788-B 50,000 E01 SERVICE 11/04/97 JFF D GROUND ROD NOT 81/D. U. CIRCUITS EXPOSED TO WEATHER E01 SERVICE 11/06/97 JFF A NOTIFIED NU B03 FRAMING (ROUGH) 11/20/97 JFF A E03 ROUGH 11/20/97 JFF A P03 ROUGH 11/20/97 JFF A PO4 GAS TEST 11/20/97 JFF A B04 INSULATION 11/24/97 JFF A B10 FINAL O1/05/97 DCJ D GUARD RAIL ON STEPS OFF DECK, STEPS FROM GARAGE TO HOUSE NEEDED,GROUND TO WATER WRONG B10 FINAL O1/07/98 DCJ A 97-10047-P 3,500 97-9941-H 5,100 97-14643-E 3,000 Total Est"Value 61,600 Dwelling 1,230 50,331.60 Basement 1,230 15,252.00 Garage 264 3,273.60 Smoke Det 7 525.00 BOCA Value 78,401.89 Difference 3 6. ....r^ A DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PERNIITJ Application is hereby: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bld Pernut# APPRO 1540 SULLIVAN AVENUE 7 644-2511 ext.230 Date Building Inspector Application must be'printed or typed Location ofjob Street No. Street Lot No. FEE SCHEDULE 0 - $1,000 - $12.00 Floor Apt. No. Over $1,000 12.00 per$1,000 OWNERoranyfractionthereof ADDRESS 77 ale"a d tla Uey • OWNERS PHONE# (0 APPLICANT t.-a OW N S ADDRESS f:r{ moo t!Q a- ESIT MATED COST$ 7(1 tOtam IS THIS A CONTRACT COST?a YES NO FEE ENCLOSED $ 7 0 1O0 R•C TYPE OF JOB: Original Installation Alteration/Addition/Repair Revised 11/95 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A X_RESIDENTIAL BUILDING PERMIT APPLICATION NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY INSTITUTIONAL FACTORY STORAGE ENGINEER'S NAME PHONE GARAGE MIXED USE ADDRESS CITY STATE ZIP 011icr please specify) TYPE OF INSTALLATION/WIRING METHOD Kr->,k4,1C` SIZE OF MAIN FEEDERS AND RATING OF WIRE USED Z`T CCpe 41, NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED?0/NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPERATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK j e 1'tGc y ,o-r 1 a© THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. NAME STATE LICENSE NO. TYPE SIG OF AP CANT PHONE NO. DATE I . i IrNSPECTOR `- DATE iA TIME LOCATIObf) 3CID - 3 -- 4, j, n INSPECTION: CODE: RESULT(D/A) : BUILDING: ELECTRICAL• s 1 j PLUMBING: HVAC: OTHER: PERMIT NO. 1 0 0 4-1 DEPARTMENT DECISION APPL I CATION FOR Application is hereby : PLUMBING PERMIT TOWM OF SOUTH WINDSOR R6DISAPPROVED BUILDING INSPECTION DEPT. 644-2511 Ext. 230 Date Building Inspector Application must be printed or typed. 1. LOCATION OF JOB: 26 Hunter Drive L.v r 31 FEE SCHEDULE 2. OWNER: B & M Enterprises 3. ADDRESS: 376 Pleasant Valley Road0 - $19 000 - 1 ry South Windsor, CT. 06074 Over $1,000 - p e r $1 ,0 0 0 or 4. APPLICANT: Hany Brothers.. Inc. fraction thereof 5. ADDRESS: 170 West Main St. , Rockville. Cr. 06066 6. EST. COST: $ 3500.00 7. IS THIS A CONTRACT COST? x YES NO 8. FEE ENCLOSED: $ 48.00 r 9. TYPE OF BUILDING: x RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: x ORIGINAL ALTERATION x INSTALLATION ADDITION REPAIR BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: 26 Hunter Drive GENERAL PLUMBING 12. KIND OF INSTALLATION: all plumbing 13. SIZE OF MAIN DRAIN 4" 14. NO. OF TOILETS 2 STYLE 1.6 15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS 1 16A. NO. OF SHOWERS 1 17. NO. OF LAVATORIES 2 18. NO. OF SINKS 1 19. DISPOSAL 1 19A. DISWASHER 1 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS 1 SIZE 3" 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? Yes 27. SIZE OF WINDOW 3 x3 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN ill 31A. SIZES OF WATER PIPING & RISERS 3/4" & 1/2" 32. REMARKS AND FURTHER DETAILS WATER HEATER 33. TYPE gas 34. MANUFACTURER_ A-0. Smith TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY 40 gal 39. RELIEF VALVE 36. TEST PRESSURE 350 LBS. 40. MANUFACTURER Watts 100XL T & P 37. WORKING PRESSURE 150 LBS. 41. PRESSURE RELIEF VALVE 38. TYPE 42. MANUFACTURER pn2n3726 10/22/97 LICENSE NO. DATE SIGNATURE OF AP LICA' PHONE NO. 872-4706 DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT 4 RNUT 914 1 Application is hcrcb,%-: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Blda Pe=0 PRVE 1540 SULLIVAN AVENUE 644-2511 ext. 230 Date Building Inspector Application must be printed or typed Location ofjob Street No. Street Lot No. FEE SCHEDULE 0 - $1,000 - $12.00 Floor Apt. No. Over $1,000 12.00 per$1,000 t 5 e-1-eCOWNERJk1 e r 'or any fraction thereof v ADDRESS 6 ( C& C o L) r C-r o 7 owt,;En PHONE#q-4 F APPLICANT 4 JQ LlAtIO—4-_b 4-C 0t ovi N st ADDRESS 10/ loa-11,917 dp-V 44( 0 (o0711Oqr ESTIMATED COST $ 070 IS THIS A CONTRACT COST? YES NO FEE ENCLOSED $ 02 ORO C TYPE OF JOB: Original Installation Alteration/Addition Repair Revised 11/95 APPLICATION FOR HVAC PERMIT(Continued from rcvcrsc side) TYPE OF SYSTEM TYPE OF BUILDING HEATING RESIDENTIAL A/C COMMERCIAL VENTILATION INDUSTRIAL 11 EATING STEAM LOW PRESSURE LIMIT LDS.HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR Z UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE_L_F INSIDE_ OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) 36$-ko.5 HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE&MODEL NO.) L & li r GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) APO TYPE OF FUEL OIL-GPM GAS-INPUT (J ELECTRIC-KW OIL TANK SIZE&LOCATION INSIDE OUTSIDE CAPACITY LPG TANK CAPACITY AIR CONDITIONING DESIGN TEMP. OUTSIDE F INSIDE 1,5 F D RENCE O F TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE&MODEL NO.) o f 0,-)-r cc)f,l o4e ose rfCc TONNAGE COOLING CAPACITY(BTUH) 07. o o VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK 5 I n Juctu.)ock j I THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. STATE LICENSE-NO. NAME&TYPE SIGNATdRE OF APPLIC PHONE NO. a U o J DATE b ld Illlllllllllllll, RESIDENTIAL AIR CONDITIONING YEAR-ROUND LOAD ESTIMATE FORM 865 Form 1605.05-F 1 rt J5 l 4_ EQUIPMENT SELECTION oe"/ d .5S"X 1( A. TOTAL COOLING LOAD -Btuh 9-5-7 UNIT CAPACITY -Btuh B. TOTAL HEATING LOAD -Btuh36:963 UNIT 417 4- -5'0 72 CAPACITY -Btuh C. DESIGN -cfm 9a4D A. DESIGN CONDITIONS SUMMER WINTER 0 INSIDE DESIGN TEMPERATURE - F i db Cjdb 1 INSIDE DESIGN RELATIVE HUMIDITY TO rr. OUTSIDE DESIGN TEMPERATURE - F db wb db m TEMPERATURE DIFFERENCE - F Z C, db db r NUMBER OF OCCUPANTS m D O B. UTILITIES POW ER SUPPLY: VOLTS PHASE CYCLE FUSE BOX -amp LOCATION: FROM CONDENSING UNIT -ft FROM FURNACE -ft ADDITIONAL ELECTRICAL SERVICE REQUIRED TO BE SUPPLIED BY h'ATER SUPPLY: CITY WELL OTHER QUANTITY AVAILABLE -gpm AVERAGE SUMMER TEMPERATURE - F o n PRESSURE AVAILABLE -pSig DISTANCE FROM UNIT -ft N CONDENSATE/OR CONDENSER DRAIN: DISTANCE FROM UNIT -ft PUMP REQUIRED C. r-HEA-rING t l GAS: NATURAL LP OTHER v SPECIFIC GRAVITY HEATING VALUE — Btu/ cu ft 1 OIL; GRADE HEATING VALUE — Btu/gal r` D. Z(,',,;TRUCTION I- i PE CONSTRUCTION INSULATION: CEILING - TYPE THICKNESS WALL - TYPE THICKNESS SLAB - TYPE THICKNESS ATTIC: UNV ENT ED VENTED EXHAUST FAN - cfm ROOF: OVERHANG -It WINDOWS: SINGLE PANE DOUBLE PANE SHADED UNSHADED INSIDE SHADING AWNINGS 3-SEMENT SLAB CRAWL SPACE 1 a YORK RESIDENTIAL LOAD FACTORS FOR COOLING AND HEATING COOLING HEATING CONSTRUCTION TEMP. DI ERENCE-Fdb TEMP. DIFFERENCE-Fdb F0 15 Lr20 25 F30F35 40 50 60 70 80 90 100 1 ;0 A OUTSIDE WALLS — Btuh PER sq ft OF AREA Z60 NOT INCLUDE WINDOW AREA) 1 NO INSULATION 4 5 6 8 9 10 10 13 15 18 20 23 25 -3 2 1 " INSULATION 3 4 5 6 7 8 8 10 12 14 16 18 20 z2 3 2" INSULATION 2 3 3 4 5 5 5 7 8 9 10 12 13 14 4 MORE THAN 2" INSULATION 2 2 2 3 3 3 4 5 6 7 8 9 10 11 B DOORS — Btuh PER sq ft OF AREA (DO NOT INCLUDE WINDOW AREA) 1 WOOD OR ALUMINUM 7 9 12 14 17 20 22 27 32 37 42 47 52 57 C INSIDE WALLS — Btuh PER sq ft OF AREA 1 BETWEEN CONDITIONED AND 2 1 3 4 5 6 7 8 9 10 12 14 15 17 19 UNCONDITIONED SPACE D CEILING BELOW VENTED ATTIC — Btuh PER sq ft OF AREA 1 NO INSULATION 8 9 10 11 13 14 24 30 37 43 49 55 61 7 2 2" INSULATION 3 3 3 3 4 4 4 5 6 7 8 9 10 11 3 4" OR MORE INSULATION 2 2 2 2 3 3 3 4 4 5 6 6 7 8 E CEILING WITH NO ATTIC OR UNVENTED ATTIC — Btuh PER sq ft OF AREA 1 NO INSULATION 14 16 18 20 22 24 20 25 30 35 40 45 50 35 2 2" INSULATION 7 8 9 10 11 12 8 11 13 15 17 19 21 23 3 4" OR MORE INSULATION 6 6 7 7 8 9 6 8 9 11 12 14 15 ;6 F CEILING UNDER UNCONDITIONED ROOM — Btuh PER sq ft OF AREA 1 NO INSULATION 2 1 2 1 3 1 4 1 5 1 6 1 9 11 13 15 17 19 21 3 G FLOORS (OMIT IF OVER BASEMENT) — Btuh PER sq ft OF AREA 1 OVER ENCLOSED CRAWL SPACE — — — — — — 9 11 14 16 18 20 23 26 2 OVER UNCONDITIONED ROOM 2 3 4 5 6 7 9 11 14 16 18 20 23 26 3 OVER VENTED CRAWL SPACE 3 4 5 7 9 11 14 17 20 24 27 31 34 37 H SLAB FLOOR ON GROUND— Btuh PER ft LENGTH OF OUTSIDE WALL 1 NO EDGE INSULATION 32 41 49 57 65 73 81 65 2 1 " EDGE INSULATION 27 34 41 48 54 61 68 75 3 2" EDGE INSULATION 22 28 33 39 44 50 55 61 J OUTSIDE AIR— Btuh PER sq ft OF TOTAL FLOOR AREA 1 DUE TO INFILTRATION 1 1 1 2 1 2 F2 1 3 6 T77 9 10 12 13 14_ 16 PEOPLE — (USE MINIMUM OF 300 NOT USED IN HEATINGK FIVE (5) — Btuh EACH L APPLIANCES — Btuh TOTAL 1200 NOT USED IN HEATING M WINDOWS — TRANSMISSION — Btuh PER sq ft OF WINDOW OPENING AREA 1 SINGLE PANE 4 8 12 1 16 20 1 24 1 45 57 1 68 79 90 102 1 113 125 2 DOUBLE PANE OR GLASS BLOCK 2 4 7 9 11 13 22 28 33 39 44 50 55 61 N SOLAR WINDOW LOAD —(COOLING ONLY)— Btuh PER sq ft OF AREA USE ALL WINDOW AREAS)OVERHANG O ft i ft 2 ft 3 It 4 ft FOR SINGLE GLASS SHADING 1 2 3 11 2 3 1 2 3 1 2 3 1 2 3 4 1 NO SHADING DEVICE 2 ROLLER SHADES HALF DRAWN N _ I 0 15 11 20 15 11 20 15 11 20 15 11 20 1 5 1 t 1 6 ODRAPES OR VENETIAN BLIND NE &NW 50 40 30 50 40 30 50 40 30 50 40 30 50 40 30 1 7 4 OUTSIDE VENTILATED AWNINGS E &W 80 60 45 70 48 38 60 42 33 52 36 28 42 29 23 1 8 SE &SW 65 50 35 53 40 32 40 31 24 27 21 17- 20 15 1 1 17 A) FOR DOUBLE PANE OR STORM S 40 25 201 281 19 14 20 15 11 20 15 117 207 15 11 , 16 WINDOWS MULTIPLY FACTORS BY .90. B) FOR HEAT ABSORBING DOUBLE GLASS MULTIPLY FACTORS BY 60. 2 YORK RESIDENTIAL COOLING AND HEATING LOAD ESTIMATE—ENTIRE HOUSE COOLING HEATING REFERENCE AREA NUMBER sq ft LOAD SENSIBLE LOAD SENSIBLE FACTOR HEAT FACTOR HEAT OUTSIDE WALLS A a„ 3 6aZ DOORS (INCLUDE GLASS WITH WINDOWS) B a 3 7 77 INSIDE WALLS C I D a.3 0 . -l c7 j 69 / 5-C OR E CEILING OR F G FLOORS OR H OUTSIDE AIR J IA3v 499, a.q 6 (3 /Q 3O O PEOPLE (5 MINIMUM) K 5 300 1500 BLOWER MOTOR HEAT HP OR 2545 ORKW3415 APPLIANCES L 1200 WINDOWS TRANSMISSION M 7 0 l OVERHANG FT. N go OSHADING 1 _ 2- 3- 4_ m NE&NW SINGLE GLASS OJ E&W N Aq 34 DOUBLE GLASS N SE&SW OHEATABSORBING_S J 13 f SUB TOTAL a 33s DUCT LOSS: ATTIC-1" DUCT INSULATION-SUB TOTAL X 1.15 X 1.25 ATTIC-2" DUCT INSULATION-SUB TOTAL X 1.10 X 1.20 SLAB FLOOR-INSULATED DUCTS IN ENCLOSED CRAWL SPACE, UNCONDITIONED BASEMENT OR FURRED SPACES SUB TOTAL X 1.05 TOTAL SENSIBLE LOAD y,Q $ 3 G 9&3 ALLOWANCE FOR LATENT LOAD-TOTAL SENSIBLE LOAD X 1.30 CORRECT FOR LOW DAILY TEMPERATURE RANGE-TOTAL LOAD X 1.05 HIGH DAILY TEMPERATURE RANGE-TOTAL LOAD X 0.96 3 YORK RESIDENTIAL LOAD FACTORS FOR COOLING FLYWHEEL" PERIOD AND SSIA. COOLING LOAD FACTORS ARE BASED ON TWENTY— 2 PRECOOLING POTEMP- E PRECOOLING FOUR HOURS TO TAKE ADVANTAGE OF PRECOOL— z PERIOD ERAT RE SLIP PERIOD ILI ING PERIODS AND FLYWHEEL EFFECT OF BUILD— a ING AND FURNISHINGS IN THE HOUSE. THIS H LOAD UNIT CAPACITY ALLOWS THE SELECTION OF A SMALLER UNIT Z WHICH WILL PROVIDE BETTER BALANCE OF REL— ATIVE HUMIDITY AND TEMPERATURE CONTROL.x 1001, OUTSIDE TEMPERATURE ON EXTREME DAY 95° B. AREAS MARKED "A" REPRESENT PRECOOLING OF 90° THE BUILDING, FURNISHINGS, AND MATERIAL 850 INSIDE TEMPERATURE ONDESIGNTEMPERATURE80FEXTREMEDAYWITHINARESIDENCE. THIS PROVIDES STORED— 800 UP COOLING WHICH DURING PEAK OUTSIDE 750 THERMOSTAT SETTING 76F TEMPERATURES TENDS TO LESSEN THE INSIDE TEMPERATURE RISE. 0 0 0 0 0 © o 8 AM 12 NOON 4 PM 8 PM 12 MIDNITE 4 AM 8 Ant SUMMER DAILY TEMPERATURE AND HUMIDITY RANGE 30 fYAS fN DA4OTA wrr+lSOu rr OVTM DAKOTA WISCONSw c r0« ,,,ASS. 40 MKMGAN IOWA Pl1AMS'1lVAMV'r / 0.lwOIS WW- Ow tr,.r.. V"w 35 vim• vuawu SSAtMiVCA1 TLNNlSStt MO A,a•+A 1-A OKLAHOMA ARKANSAS A"' 1M w. S A,O%,HA AIASArJ Gl'JtGw 30 30 vr SSO" S.r Vtiw M.wwr. O•S."• /lMOA u`AREA TEMP. HUMIDITY RANGE RANGE u LOW HUMID Q MED. AVERAGE HIGH DRY NATIONAL WARM AIR HEATING AND AIR CONDITIONING C. IT IS ALSO NECESSARY TO ACCOUNT FOR THE SUMMER DAILY TEMPERATURE RANGE. 1. THE SUMMER DAILY TEMPERATURE RANGE IS THE AVERAGE TEMPERATURE SWING WHICH OCCURS DURING THE COOLING SEASON. THE LOAD FACTORS ARE BASED ON THE MEDIUM TEMPERATURE RANGE. CORRECTION FACTORS MUST BE APPLIED TO AREAS IN THE LOW AND HIGH TEMPERATURE RANGES. THE AREAS ON THE MAP ARE AVERAGES SO LOCAL CONDITIONS WITHIN AN AREA SHOULD BE CONSIDERED TO DETERMINE THE TEMPERATURE RANGE TO USE. 2. MEDIUM TEMPERATURE RANGE (15 F — 25 F) A) FOR LOW TEMPERATURE RANGE (LESS THAN 15F) MULTIPLY TOTAL LOAD BY 1.05. B) FOR HIGH TEMPERATURE RANGE (GREATER THAN 25 F) MULTIPLY TOTAL LOAD BY 0.96. 3. THEREFORE, A RESIDENCE LOCATED IN A HIGH TEMPERATURE RANGE AREA HAS A GREATER FLYWHEEL EFFECT THAN ONE LOCATED IN A MEDIUM OR LOW TEMPERATURE RANGE AREA. SUBJEC I- TO CHANGE WITHOUT NOTICE PRINTED IN U.S.A. YORK =- P.O., I'273 .10L BOX 1592, YORK, PENNSYLVANIA 17405