Loading...
HomeMy WebLinkAbout26 Chandler Drive (6)DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby:TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT APPROVED— 1540 SULLIVAN AVENUE Bldg.Permit# j4A, 644-2511 ext. 230 Date Building Inspector Application must be printed or typed C ocation of Job: FEE SCHEDULE GhA aJ 0r, 0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT 6211rhrvo- Pltl"17-0 Ile APPLICANT ADDRESS xorf T 06e7y APPLICANT PHONE# y OWNER OWNER ADDRESS OWNER PHONE ESTIMATED COST$ l U IS THIS A CONTRACT COST? 17 Yes /doRo CJ FEE ENCLOSED$ I3 s IS TYPE OF JOB: pR.CO RfeNew Installation C3 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF YYTEM: TYPE OF BUILDING: HEATING 0 RESIDENTIAL A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING kAM LOW PRE URE LIMIT LBS. HIGHPRESSURE LIMIT LBS. DRONIC WARM AIR UNIT RADIANT HEATER ING RADIATIO ADDITIONAL RADIA I N TOTAL RADIATION DESIGN TEMP. OUTSIDE_°F INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUI MENT(INCLUDING MAKE&MODEL NO.) s T cj-7 dv 0GROSSHEATINGCAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL OIL—GPM OIL TANK LOCATION :INSIDE OUTSIDE CAPACITY EGAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. STATE SIGNATURE OF APPLICANT DATE RIGHT4 LOAD AND EQUIPMENT SUMMARY Entire House g a U Project Inf• vt ,h414 For. PAT JOKES SOUTH WINDSOR, CT Notes: Design Information Weather: Windsor Locks, Bradley Fld, CT, US Winter Design Conditions Summer Design Conditions Outside db 8 OF Outside db 88 OF Inside db 70 OF Inside db 75 OF Design TD 62 OF Design TD 13 OF Daily range M Relative humidity 50 % Moisture difference 22 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Building heat loss 88739 Btuh Structure 55795 Btuh Ventilation air 0 cfm Ventilation 0 Btuh Ventilation air loss 0 Btuh Design temperature swing 3.0 OF Design heat load 88739 Btuh Use mfg. data n Ratelswing multiplier 0.93 Infiltration Total sens. equip. load 51889 Btuh Method Simplified Latent Cooling Equipment Load SizingConstructionqualityAverage Fireplaces 1 Internal gains 1840 Btuh Ventilation 0 Btuh Heatin Coolin Infiltration 2722 Btuh Area(ft2)2862 2869 Total latent equip. load 4562 Btuh Volume(ft3) 27089 27089 Air changesthour 0.9 0.4 Total equipment bad 56452 Btuh Equiv.AVF(cfm)407 181 Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Efficiency 80.0 AFUE Efficiency 0.0 EER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Heating temp rise 0 OF Total cooling 0 Btuh Actual heating fan 2984 cfm Actual cooling fan 2984 cfm Heating air flow factor 0.034 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh Space thermostat Load sensible heat ratio 92 % Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wnoht:roft Rigffl,%te Residential"'5.0.38 RSRRUD26387 2001-Jul-06 13:59:48 AM C:VAy Doaxn A9XRuudIBASE.rsr Page 1 RIGHT-J SHORT FORM Entire House Project Inf• For: PAT JOBES SOUTH WINDSOR, CT Design Information Htg Cig Infiltration Outside db(OF) 8 88 Method Simplified Inside db(OF) 70 75 Construction quality Average Design TD(OF)62 13 Fireplaces 1 Daily range M Inside humidity(%) 50 Moisture difference(gr/lb) - 22 HEATING EQUIPMENT COOLING EQUIPMENT Mak Make Trade Trade Efficiency 80.0 AFUE Efficiency 0.0 EER H ating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Heating temperature rise 0 OF Total cooling 0 Btuh Actual heating fan 2984 cfm Actual cooling fan 2984 cfm Heating air flow factor 0.034 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh Space thermostat Load sensible heat ratio 92 % ROOM NAME Area Htg load Clg load Htg AVF Cig AVF ft2) Btuh) Btuh) cfm) cfm) KITCHEN/FAMILY M 612 25170 16781 846 897 LAUNDRY/MUD ROOM 55 2592 2965 87 159 LIVING ROOM 169 5777 3514 194 188 ENTRY 121 5823 3206 196 171 DINING ROOM 60 4765 3553 160 190 MASTER BEDROOM 300 5096 3265 171 175 MASTER BATH 100 2518 3187 85 170 BATH 60 381 146 13 8 BACK BEDROOM 208 3809 2852 128 153 FRONT S. BEDROOM 195 3780 2835 127 152 FRONT N. BEDROOM 182 4438 3001 149 160 BONUS ROOM 800 24591 10490 827 561 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. fft:. wnghtSoft Right-Suite Residential"'5.0.38 RSRRUD26387 2001-Jul-06 14:03:33 C:Wy DocumeMsXRuud16ASE.rsr Pag 1 V J