HomeMy WebLinkAbout26 Chandler Drive (6)DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
PERMIT#
Application is hereby:TOWN OF SOUTH WINDSOR
BUILDING DEPARTMENT
APPROVED— 1540 SULLIVAN AVENUE Bldg.Permit#
j4A, 644-2511 ext. 230
Date Building Inspector
Application must be printed or typed
C
ocation of Job:
FEE SCHEDULE
GhA aJ 0r,
0-$1,000=$13.00 Street No. Street Lot No.
Over$1,000=
13.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT 6211rhrvo- Pltl"17-0 Ile
APPLICANT ADDRESS xorf
T 06e7y
APPLICANT PHONE# y
OWNER
OWNER ADDRESS
OWNER PHONE
ESTIMATED COST$
l U
IS THIS A CONTRACT COST? 17 Yes /doRo
CJ FEE ENCLOSED$ I3
s
IS TYPE OF JOB:
pR.CO RfeNew Installation
C3 Alteration/Addition/Repair Revised 8/99
APPLICATION FOR HVAC PERMIT (Continued from reverse side
TYPE OF YYTEM: TYPE OF BUILDING:
HEATING 0 RESIDENTIAL
A/C COMMERCIAL
VENTILATION INDUSTRIAL
HEATING
kAM
LOW PRE URE LIMIT LBS. HIGHPRESSURE LIMIT LBS.
DRONIC WARM AIR UNIT RADIANT HEATER
ING RADIATIO ADDITIONAL RADIA I N TOTAL RADIATION
DESIGN TEMP. OUTSIDE_°F INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) °F(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEATING EQUI MENT(INCLUDING MAKE&MODEL NO.)
s T
cj-7 dv 0GROSSHEATINGCAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH)
TYPE OF FUEL
OIL—GPM OIL TANK LOCATION :INSIDE OUTSIDE CAPACITY
EGAS—INPUT LPG TANK CAPACITY ELECTRIC—KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
TONNAGE COOLING CAPACITY(BTUH)
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
CONTRACTORS LICENSE NO. STATE
SIGNATURE OF APPLICANT DATE
RIGHT4 LOAD AND EQUIPMENT SUMMARY
Entire House g a
U
Project Inf•
vt ,h414
For. PAT JOKES
SOUTH WINDSOR, CT
Notes:
Design Information
Weather: Windsor Locks, Bradley Fld, CT, US
Winter Design Conditions Summer Design Conditions
Outside db 8 OF Outside db 88 OF
Inside db 70 OF Inside db 75 OF
Design TD 62 OF Design TD 13 OF
Daily range M
Relative humidity 50 %
Moisture difference 22 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Building heat loss 88739 Btuh Structure 55795 Btuh
Ventilation air 0 cfm Ventilation 0 Btuh
Ventilation air loss 0 Btuh Design temperature swing 3.0 OF
Design heat load 88739 Btuh Use mfg. data n
Ratelswing multiplier 0.93
Infiltration Total sens. equip. load 51889 Btuh
Method Simplified Latent Cooling Equipment Load SizingConstructionqualityAverage
Fireplaces 1 Internal gains 1840 Btuh
Ventilation 0 Btuh
Heatin Coolin Infiltration 2722 Btuh
Area(ft2)2862 2869 Total latent equip. load 4562 Btuh
Volume(ft3) 27089 27089
Air changesthour 0.9 0.4 Total equipment bad 56452 Btuh
Equiv.AVF(cfm)407 181
Heating Equipment Summary Cooling Equipment Summary
Make Make
Trade Trade
Efficiency 80.0 AFUE Efficiency 0.0 EER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Heating temp rise 0 OF Total cooling 0 Btuh
Actual heating fan 2984 cfm Actual cooling fan 2984 cfm
Heating air flow factor 0.034 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh
Space thermostat Load sensible heat ratio 92 %
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wnoht:roft Rigffl,%te Residential"'5.0.38 RSRRUD26387 2001-Jul-06 13:59:48
AM C:VAy Doaxn A9XRuudIBASE.rsr Page 1
RIGHT-J SHORT FORM
Entire House
Project Inf•
For: PAT JOBES
SOUTH WINDSOR, CT
Design Information
Htg Cig Infiltration
Outside db(OF) 8 88 Method Simplified
Inside db(OF) 70 75 Construction quality Average
Design TD(OF)62 13 Fireplaces 1
Daily range M
Inside humidity(%) 50
Moisture difference(gr/lb) - 22
HEATING EQUIPMENT COOLING EQUIPMENT
Mak Make
Trade Trade
Efficiency 80.0 AFUE Efficiency 0.0 EER
H ating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Heating temperature rise 0 OF Total cooling 0 Btuh
Actual heating fan 2984 cfm Actual cooling fan 2984 cfm
Heating air flow factor 0.034 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh
Space thermostat Load sensible heat ratio 92 %
ROOM NAME Area Htg load Clg load Htg AVF Cig AVF
ft2) Btuh) Btuh) cfm) cfm)
KITCHEN/FAMILY M 612 25170 16781 846 897
LAUNDRY/MUD ROOM 55 2592 2965 87 159
LIVING ROOM 169 5777 3514 194 188
ENTRY 121 5823 3206 196 171
DINING ROOM 60 4765 3553 160 190
MASTER BEDROOM 300 5096 3265 171 175
MASTER BATH 100 2518 3187 85 170
BATH 60 381 146 13 8
BACK BEDROOM 208 3809 2852 128 153
FRONT S. BEDROOM 195 3780 2835 127 152
FRONT N. BEDROOM 182 4438 3001 149 160
BONUS ROOM 800 24591 10490 827 561
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
fft:. wnghtSoft Right-Suite Residential"'5.0.38 RSRRUD26387 2001-Jul-06 14:03:33
C:Wy DocumeMsXRuud16ASE.rsr Pag 1