Loading...
HomeMy WebLinkAbout26 Castlewood Drive (7)a DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby:TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT ArPPRO 1540 SULLIVAN AVENUE Bldg.Permit# 0 J — 644-2511 ext. 230 Date Building Inspector Application must be printed or typed Location of Job: FEE SCHEDULE VZ2/,- ,hZ,,-j2 O RU y 0-$15000=$13.00 Street No. Street Lot No. n Over$15000= 4r1"0 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS _S`Q 7-,,o%f eQ ,e cl s6v 4?!g ,Of//NC/.S'Dr /2dP_0'- 0j:1 7 3 APPLICANT PHONE# gf_-6 a _.2,PZ— leg OWNER 6111 C OWN S Fq T000 r OWNER ADDRESS OWNER PHONE C ESTIMATED COST$ ?'2 d D IS THIS A CONTRACT COST? ;tYes 13 No CJ FEE ENCLOSED$ r f Spg.CO TYPE OF JOB: New Installation 13 Alteration/Addition/Repair Revised 8/99 1 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: HEATING W RESIDENTIAL XA/C COMMERCIAL VENTILATION INDUSTRIAL EATING AM LOW PRESSURE LIMIT LBS. HIGH PRESS LBS. HYDR WARM AIR UNIT HEATER EXISTING RADIATIO ADDITIONAL ON TOTAL RADIATION DESIGN TEMP. OUTSIDE SIDE OF DIFFERENCE OF TOTAL HEAT LOSS(B F{HEAT LO MUST ACCOMPANY APPLICA DESC ALL HEATING EQUIPMENT(INCLUDING MAKE&MOD GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL OIL-GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE Rg -OF INSIDE 7 D OF DIFFERENCE /4' OF TOTAL HEAT GAIN(BTUH),-;,ZA= (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE , COOLING CAPACITY(BTUH) lJ VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK .5z,4,g1,. THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 3 7 -2 Z)-- Cl?4' CONTRACTORS LICENSE NO. STATE SIGNATURE OF APPLI DATE .- 7 y-' RIGHT-J LOAD AND EQUIPMENT SUMMARY Entire House R& E Heating & Cooling Inc. Job:243-049 26 Castelwood Road 5-24-02 310 Nutmeg Rd.South,South Windsor,CT 08074 Phone:860.282-7782 Fax:860-282-7701 Project li-iforr-natioll For: Clark Realty,lnc 658 Ellington RD, South Windsor,CT 06074 Notes: 243-049 26 Castelwood Road Inforrnatiorl Weather: Hartford,Brainard Field,CT, US Winter Design Conditions Summer Design Conditions Outside db 6 OF Outside db 88 OF Inside db 70 OF Inside db 70 OF Design TD 64 OF Design TD 18 OF Daily range M Relative humidity 50 % Moisture difference 38 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Building heat loss 53986 Btuh Structure 32300 Btuh Ventilation air 0 cfm Ventilation 0 Btuh Ventilation air loss 0 Stuh Design temperature swing 3.0 'F Design heat load 53986 Stuh Use mfg.data n Rate/swing multiplier 0.93 Infiltration Total sens.equip. load 30039 Btuh Method Simplified Latent Cooling Equipment Load SizingConstructionqualityAverage Fireplaces 1 Internal gains 2300 Btuh Ventilation 0 Btuh Heating Cooling Infiltration 4324 Btuh Area(ft2)2976 2976 Total latent equip. load 6624 Btuh Volume(ft3) 25200 25200 Air chap r 0.9 0.4 Total equipment load 36663 Btuh Equiv.A) 379 168 Heating Equipment Summary Cooling Equipment Summary Make n/a Make Heiil Trade n/a Trade Heil n/a HAC060 FCP60 Efficiency n/a Efficiency 10.0 EER Heating input 0 Btuh Sensible cooling 42000 Btuh Heating output 0 Btuh Latent cooling 18000 Btuh Heating temp rise 0 of Total cooling 60000 Btuh Actual heating fan 2000 cfm Actual cooling fan 2000 cfm Heating air flow factor 0.037 cfm/Btuh Cooling air flow factor 0.062 cfm/Btuh Space thermostat Load sensible heat ratio 83 % Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wnCphtsoft Right-Suite Residential"'5.0.28 RSR27412 2002-May-24 09:14:59 C:Wy Documents1WfthtsoR HVAC1243-049 26 Castelwood Road.rsr Page 1 RIGHT-J SHORT FORM Entire House R& E H ating & Cooling Inc. J b:243-049 26 Ca teiwood Road 5-24-02 310 NW M Rd.South,South Windsor,CT OW74 Phone:860-282-rM Fax:M282-7701 Project • For: Clark Realty,lnc 658 Ellington RD, South Windsor,CT W074 Design Information Htg Clg Infiltration Outside db(°F) 6 88 Method Simplified Inside db(°F) 70 70 Construction quality Average Design TD(°F)64 18 Fireplaces 1 Daily range M Inside humidity(%) 50 Moisture difference(gr/lb) - 38 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make Hefil Trade n/a Trade Heil n/a HAC060 FCP60 Efficiency n/a Efficiency 10.0 EER Heating input 0 Btuh Sensible cooling 42000 Btuh Heating output 0 Btuh Latent cooling 18000 Stuh Heating temperature rise 0 °F Total cooling 60000 Btuh Actual heating fan 2000 cfm Actual cooling fan 2000 cfm H ating air flow factor 0.037 cf n/Btuh Cooling air flow factor 0.062 cf n/Btuh Space thermostat Load sensible heat ratio 83 % ROOM NAME Area Htg load Clg load Htg AVF Clg AVF fr) Btuh) Btuh) cfm) cfm) First Floor 1392 32772 22692 1214 1405 Second Floor 15M 21214 9607 786 595 Entire House d 2976 53986 32300 2000 2000 Ventilation air 0 0 Equip.Q 0.93 RSM 30039 Latent cooling 6624 TOTALS 1 2976 1 53986 36663 2000 2000 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. k.; vynghtSC ft Right-Suite Residential-5.0.28 RSR27412 2002-May-24 09:14:59flo* CAMy DocunwwWWrightsoft HVAC1243-049 26 Castelwood Road.rsr Page 1