HomeMy WebLinkAbout25 Sunrise LaneElectric# I l,. n APPLICATION FOR BUILDING PERMIT Plumbing# 4 v W5 25 SUNRISE LANE HVAC # b ras". 25567 Dat : Alge Sprinkler# NO' S FINAL APPROVALN2--7199 Estimated Cost $ 19666 Building COMPLETE RED BOXED AREAS Permit Fee 401 Engineering TYPE OR PRINT ONLY Occupancy Fee $ AffidavitSIGN ON REVERSE SIDE Appr.for CO.7 Total Fee 41011 TO BUILDNC'DEPARTMENT,TOWN OF SOUTH WI DSOR,CT motional Cost) a— The undersigned hereby applies to do work according to the following specifications: Job Location J,6- S u/il l'/S' X,_Lot No.--:3 _Side of Street Zone A-?o Applicant J2t/Vt Esiff'e°PRI SPS 1,k—, Tel.# 6S/r/-S28T Address ;50/., )O (,p Zip 01ko7 Lic.# Owner r--8C t k&) Address J L Aloe a• Architect tt-aM 9- b2S1 6n1 Address f 8L/ 1,JrNbSa R AOL , zowoso2T CT 060'?r Sq.Ft.New Area: lst FI. 15-4o'C/2nd Fi. /3 g 7 3rd Fl. Total New Area .2g9t Rooms /O Lavatories Bathrooms 3 Garages 3 Purpos of this permit: 9)N6L E FAIN I L Y bwF C L/rV City Water Well Septic System Sewer Ins. H.O. S.P. Cert. Area Basement Garage LOO S Approved by Date—:IN5 S Use Group Construction Type RwWA 1/97 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in whiAtiilding an is allowed. Signed I hereby apply for a Certificate of Occupancy for the work d in this application for the permit. 12Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Location of Job:AFFIDAVIT Additional Fee$ -0- State of Connecticut} ss.South Windsor County of Hartfor Ie'- k of L. iwi: Agent for the building erected 25567 Contractor under Permit No. issued by the Building Department of the Town of South Windsor being duly sworn,make oath and say that the actual cost f c f1etedd ork authorizeMsaid d not exceed the most current accepted BOCA value of$ 1y •U' Signed Subscribed and sworn to before me this OA day of A.D.19a Estimated Cost$ 1 91 ,0 0 0. 0 0 Difference: $ -0- ry Public Inspection / Approval Date By Appl Code Description Due Whom Code Comment 98-25567-B 168,000 B01 FOOTING 09/18/98 DCJ A B02 FOUNDATION 09/30/98 DCJ A P02 UNDERGROUND 10/16/98 DCJ A E01 SERVICE 11/23/98 DCJ A RELEASED TO N.U. P03 ROUGH 12/09/98 JFF A B03 FRAMING (ROUGH) 12/30/98 DCJ A SPECS TO BE SUBMITTED FOR CHANGE OF BEAM IN GARAGE E03 ROUGH 12/30/98 DCJ A B04 INSULATION 01/08/99 DCJ A B05 FIREPLACE/CHIMNEY 01/08/99 DCJ A PO4 GAS TEST 01/15/99 DCJ A LEFT STICKER B03 FRAMING (ROUGH) 01/27/99 DCJ A BOLTING OF BEAMS IN GARAGE B10 FINAL 05/20/99 DCJ D EGRESS THRU RM. FROM M.BEDRM. , SELF CLSR ON GAR. DOOR, GRND SERV TO H2O, G RAIL BSMT STAI B10 FINAL 05/24/99 DCJ D NOT READY B10 FINAL 05/27/99 DCJ A APPROVED FOR CO CLOSEOUT 98-10329-H 10,000 98-10259-P 9,000 98-16050-E 4,000 Total Est Value 191,000 Dwelling 2,975 121,737.00 Basement 1,555 19,282.00 Garage 1,008 12,499.20 Smoke Det 7 525.00 BOCA Value 174,068.82 Difference 16,931.18) rj5q1C-R— -10 ' t A s SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 25 SUNRISE LANE LOT_# 3 Reviewed B E ttlBering)B & M ENTERPRISES Date Reviewed Z7 A ro enied 376 PLEASANT VALLEY RD,SOUTH WINDSOR,C Reviewed By P anning) BP_#_25567_ Ph_#_(203) 528-5418 Date Reviewed pprov Denied Date Submitted 09/09/98 FOR of 0 As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 4z 1. Approved building permit plan J/- 2. Finish grading per approved building permit plan 3. Site work; i.e. trees, shrubs, dumpsters, required parking 4. Utility location; a. sanitary sewer/septic system b. foundation drain C. electrical & telephone d. water e e. other CC,A-D 5. Sewer connection charge paid j y a`6 6. Appropriate certification 7. Bonding 8. Planning & Zoning/ Inland Wetlands Considerations Sewer Permit No. uorn Pavement Excavation No. COMMENTS: CIAJT14- NI-T Wu-J L JT C4ADE:S woWk -r F)L--(,D• y60U: LAJ" /IA .,-14Vn, SI4.7 PA JQL Wid 1gLP- J6r'(li-/ (J' &L o1-<:, rt, ,,- it,.:T 4 AA t9.--GRWP AND S DE , 1mum O M u Y a -,,N. o. . ,r , eJ : .—r —_-.. ;,E f , MAY 2 6 1999 N tz SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 25 SUNRISE LANE LOT_## 3 Reviewed By J Engineering) B & M ENTERPRISES Date Reviewed prov enied 376 PLEASANT VALLEY RD,SOUTH WINDSOR,C Reviewed By Planning) BP_#_25567 Ph_#_(203)528-5418 Date Reviewe pprov Denied Date Submitted 09/09/98 FO BUIL I G PER In accordance with the Zoning and/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include: Approved Denied N/A 1. Name, address & phone number of owner/applicant 2. Name, address & phone number of plan preparer 3. Zoning Information - i.e. zone, open space, floodway, etc. 4. Plot Plan at 1" = 40' scale a. Subdivision reference, abutting properties, etc b. Easements of record C. Lot description, bearings, building lines, distances, area, etc. l d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate e. Building location with dimensions. Elevations of proposed finish floor, garage floor & centerline of road at driveway ff. Elevations of gravity drainage systems, sanitary foundation drain at the house and the street V g. Tentative utility location (gas, water, electric, septic system, etc.) h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements. (P.E. & L.S.) 5. Sedimentation and erosion control 6. Special Planning & Zoning, Inland/Wetlands considerations (Plans on file w/Town Clerk) COMMENTS: 9 10 ll R cEn EO S Ep o DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PERMIT# CATI O Application is hereby: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit# APPROVED 1540 SULLIVAN AVENUE 644-2511 ext.230 Date wilding Inspector Application must be printed or typed Location ofjob Street No. Street Lot No. FEE SCHEDULE Floor Apt.No. 0 - $1,000 - $12.00 Over $1,000 12.00 per$1,000 OWNER or any fraction thereof ADDRESS I OWNERS PHONE# APPLICANT OWN g ADDRESS ?F.d'` C 3 44( ESTIMATED COST$ d O l C = IS THIS A CONTRACT COST? YES NO j 1 FEE ENCLOSED $ QY sOR C0 TYPE OF JOB: Original Installation Alteration/Addition/Repair Revised 11/95 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL BUILDING PERMIT APPLICATION YES / NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY INSTITUTIONAL FACTORY STORAGE ENGINEER'S NAME PHONE GARAGE MIXED USE ADDRESS CITY STATE ZIP Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF MAIN FEEDERS AND RATING OF WIRE USED NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED?YES/NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPERATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN. BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. NAME STATE LICENSE NO.' TYPE SIGNATURE OF APPLICANT PHONE NO. DATE il5g 3CTOR G 3 DATZ 23 TIME LOCATION 5 INSPECTION: CODE: RESULT(D/A) : f zIS I BUILDING: ELECTRICAL: Leh t F G PLUMBING: F HVAC: E P i OTHER: 64, I f i t' DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT q Application is hereby: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit# APPROVE 1540 SULLIVAN AVENUE 644-2511 ext. 230 Date Building Inspector Application must be printed or typed Location ofjob Street No. Street Lot No. FEE SCHEDULE Floor Apt.No. 0 - $1,000 - $12.00 Over $1,000 12.00 per$1,000 or any fraction thereof OWNER rvl A I ADDRESS i c6 p OWNERS PHONE# APPLICANT OWN 3 ADDRESS g?c rS;cc s% pb• x • 3o Z 7 2- r 4 y , C-r . 4 G (33-a 2.7Z C ESTIMATED COST$ , 4Q 0 a C] IS THIS A CONTRACT COST? YES NO FEE ENCLOSED $ OF JOB:OR-Co E Original Installation Alteration/Addition/Repair Revised 10/96 APPLICATION FOR PLUMBING PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION YES / NO RESIDENTIAL BUSINESS CURRENT USE AND OCCUPANCY ASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCYEDUCATIONAL INSTITUTION FACTORY ENGINEER'S NAME PHONE STORAGE GARAGE ADDRESS MIXED USE CITY STATE ZIP Other please specify) TYPE OF INSTALLATION SIZE OF MAIN DRAIN NO. OF TOILETS STYLE NO. OF URINALS STYLE NO. OF BATHTUBS NO. OF SHOWERS NO. OF LAVATORIES NO. OF CONDUCTORS SIZE NO. OF STACKS SIZE AREA OF ROOF NO. OF CATCH BASINS NO. OF FLOOR DRAINS NO. OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW YES/NO SIZE OF WINDOW IF NONE C.F.M. OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER WATER BEATER TYPE MANUFACTURE TANKS SAFETY DEVICES TEMPERATURE CAPACITY RELIEF VALVE TEST PRESSURE WORKING PRESSURE PRESSURE RELIEF VALVE TYPE MANUFACTURER DESCRIPTION OF WORK CD'p-t h 7—(e F-(C--,— C THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. NAME STATE LICENSE NO. TYPE SIGNATURE OF APPLICANT PHONE NO.06 U-QS U33 DATE f-rJ DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PER tiIIT Application is hereby TOWN of SOUTH WINDSOR BUELDING DEPARTMENT Bldg Permit# APPROVED 1540 SULLIVAN AVENUE L t - 644-2511 est. 230 Date Building Inspector Application must be printed or typed Location ofjob Street No. Street Lot No. FEE SCHEDULE 0 - $1,000 - $12.00 Floor Apt.No. Over $1,000 12.00 per$1,000 or any fraction thereof OWNER-r S P ADDRESS • c5 n / s 8 Et i OWNERS PHONE# APPLICANTA OW N SE•q ADDRESS 70 e y r Z< ESTIMATED COST $ IS THIS A CONTRACT COST? YES NO 3 L` FEE ENCLOSED $ S R C Q TYPE OF JOB: ginal Installation Alteration/Addition/Repair Revised 11/95 s APPLICATION FOR HVAC PERMIT(Continued from reverse side) TYPE OF SYSTEM TYPE OF BUILDING HEATING RESIDENTIAL A/C t/ COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS.HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIRs,,n UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE 4 F INSID) c2 F DIFFERENCETO F TOTAL HEAT LOSS(BTUH) -22L6 9 HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE&MODEL NO.) 6/00 GROSS HEATING CAPACITY (INPUT-BTUH on6ET RATING (OUTPUT-BTUH) ,, TYPE OF FUEL OIL-GPM GAS-INPUT,/ ELECTRIC-KW OIL TANK SIZE&LOCATION INSIDE OUTSIDE CAPACITY LPG TANK CAPACITY AIR CONDITIONING DESIGN TEMP. OUTSIDE F INSIDE75 F DIFFERENCE Z,of TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING E UIPMENT (I CLUDING MAIL &MODEL NO.) E e__ l TONNAGE_ COOLING CAPACITY(BTUH) 7 a t CUln VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 3 3 Iq 51 . STATE LICENSE-NO. NAME&TYPE SIGWA APPLICANT PHONE NO.,), C, Z—DATE // 9 EO ADVANCED HEATING & AIR CONDITIONING INC. JOB NAME: B&M Enterprises So. Windsor DESIGN CONDITIONS TOTAL BLDG. HEAT LOSS/GAIN PHONE 644-5288 PO Box 1060 CT. BLDG : Lot13 Sunrise Estates Heating: 70 deg f.t/d BLDG Heat Loss BTU 39,968 Estimator: NOTES: 25 Sunrise &q 4 r-Cooling: 20 deg f.t/d BLDG A/C Gain BTU 47,949 Stephen Smith Room i Room 2 Room 3 Room 4 Room 5 Room 6 Room 7 Room 8 Room 9 Room 10 Room 11 Room 12 AREA NAME; Family Study Foyer Dining Mud Kitchen Dinette Master Mas Clos Bed 2 Lav Bed 3 Outside Nall Length; 39.0 29.0 15.0 20.0 41.0 14.0 13.0 48.0 42.0 11.0 5.0 28.0 Outside Wall Height; 9.0 9.0 18.0 9.0 9.0 9.0 9.0 9.0 8.0 8.0 8.0 8.0 Sq/Ft S or W Glass ; 28.0 42.0 40.0 28.0 6.0 0.0 0.0 28.0 0.0 0.0 0.0 0.0 Sq/Ft N or E Glass ; 62.0 0.0 0.0 0.0 0.0 9.0 42.0 24.0 0.0 24.0 0.0 24.0 No of Doors 0.0 0.0 1.0 0.0 3.0 0.0 0.0 0.0 1.0 0.0 0.0 0.0 Floor Width 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 16.5 0.0 0.0 0.0 Floor Length 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 9.0 0.0 0.0 0.0 Roof Width 6.0 0.0 15.0 0.0 8.0 0.0 0.0 31.0 16.5 11.0 5.0 12.5 Roof Length 14.0 0.0 18.5 0.0 25.0 0.0 0.0 14.0 9.0 13.0 13.0 15.5 Area Cubic Feet 756 0 4,995 0 1,800 0 0 31906 1,188 11144 520 1,550 Gross Wall sq/ft 351 261 270 180 369 126 117 432 336 88 40 224 Net Wall sq/ft 261 219 209 152 300 117 75 380 315 64 40 200 Wall Heating BTU 731 613 585 426 840 328 210 1,064 882 179 112 560 Wall Cooling BTU 365 307 293 213 420 164 105 532 441 90 56 280 S/W Glass sq/ft 28 42 40 28 6 0 0 28 0 0 0 0 S/W Glass Heating BTU 1,215 1,823 1,736 1,215 260 0 0 1,215 0 0 0 0 S/W Glass Cooling BTU 336 504 480 336 72 0 0 336 0 0 0 0 S/W Glass Solar BTU 2,240 3,360 3,200 2,240 480 0 0 2,240 0 0 0 0 N/E Glass sq/ft 62 0 0 0 0 9 42 24 0 24 0 24 N/E Glass Heating BTU 2,691 0 0 0 0 391 1,823 1,042 0 1,042 0 1,042 N/E Glass Cooling BTU 744 0 0 0 0 108 504 288 0 288 0 288 N/E Glass Solar BTU 2,480 0 0 0 0 360 1,680 960 0 960 0 960 Doors sq/ft 0 0 21 0 63 0 0 0 21 0 0 0 Door Heating BTU 0 0 470 0 1,411 0 0 0 470 0 0 0 Door Cooling BTU 0 0 168 0 504 0 0 0 168 0 0 0 Floor sq/ft 84 0 278 0 200 0 0 434 149 143 65 194 Floor Heating BTU 0 0 0 0 0 0 0 0 2,079 0 0 0 Floor Cooling BTU 0 0 0 0 0 0 0 0 0 0 0 0 Roof sq/ft 84 0 278 0 200 0 0 434 149 143 65 194 Roof Heating BTU 176 0 583 0 420 0 0 911 312 300 137 407 Roof Cooling BTU 71 0 233 0 168 0 0 365 125 120 55 163 Lights Cooling BTU 72 0 237 0 171 0 0 370 127 122 55 165 Appliance Cooling BTU 59 0 194 0 140 0 0 304 104 100 46 136 People Cooling BTU 43 0 142 0 102 0 0 222 76 73 33 99 Latent Cooling BTU 38 0 126 0 91 0 0 197 67 65 29 88 Ventilation Heat BTU 866 438 607 295 528 129 366 762 674 274 45 362 Ventilation Cool BTU 1,161 751 913 502 387 114 412 1,046 199 327 49 392 Duct Heat Loss BTU 341 172 239 116 208 51 144 300 265 108 18 142 Duct Cool Loss BTU 456 295 359 197 152 45 162 412 78 129 19 154 Area Heating BTU 6,020 3,047 4,221 2,052 3,667 898 2,543 5,294 4,682 1,903 311 2,512 Area Cooling BTU 8,065 5,217 6,344 3,488 2,686 790 2,863 7,271 1,386 2,274 343 2,725 Area Air Heating CFM 79 40 56 27 48 12 33 70 62 25 4 33 Area Air Cooling CFM 269 174 211 116 90 26 95 242 46 76 11 91 TTL Building. Square feet-) 1,763 Heating Air Changes/Hour -> 1.79 TTL Building. Cubic feet-> 17,595 Cooling Air Changes/Hour -> 5.45 TTL Building Heating CFM -> 526 Heating CFM per SQ/FT ->0.30 TTL Building Cooling CFM 1,598 Cooling CFX per SQ/FT ->0.91 11/08/98 HEATING/COOLING BTU ESTIMATE: