Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
25 Summit Drive
Electric# APPLICATION FOR BUILDING PERMIT Plum6ing# 7 25 SUMA'IIT DRIVE HVAC # 9 I5 H 22845 Date: Sprinkler# TM1 No. FINAL P R Estimated Cost $ f Buildin 6 .6 COMPLETE RED BOXED AREAS Permit Fee Enginee in TYPE OR PRINT ONLY Occupancy Fee $43 Affidavit U 07 SIGN ON REVERSE SIDE Appr.for CO. Total Fee TO BUILDI EPARTMENT, TOWN OF SOUTH WINDSOR,CT Additional Cost) $ Th undersigned hereby applies to do work according to the following specifications: Job Location,,?s S'u rn W,I T)r- Lot No. Side of Street_Zone Applicant_Jrp_?:nc, Tel. # T' / Address Q 22 Si.ill j rjctjr' Zip Lic.# Owner e._ Address Architect Address.39 n?&rrnu) 12j 000'?4 Sq. Ft.New Area: 1st FI. 2nd FI. /061 _ 3rd FI. n Total New Area Rooms Lavatories Bathrooms Garages Purpose of this permit:V&U-) hatge j2rM-A/_,JrL224 City Water 2""' Well Septic System Sewer, Use Group Construction Typ Area Q / Basem nt ION Garag Approved by jak-_ Date f2j& Revised 6/95 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked, and agree that this building is to be located the proper distance from all street lines, side yard lines and required distances from all other zones and is located in a on in which this budding and its use is allowed. Signed I hereby apply for a Certificate of Occupancy for the work described in this applicaVonfor the permit Signed 6"a 'Z' DO NOT WRITE BELOW THIS LINE - INSPECTION COMMENTS Location of Job: AFFIDAVIT Additional Fee S 6 0. 0 0 State of Connecticut ss.South Windsor County of Hartford Owner I of e4 cD 7'ncZ C A en the building erected ontractor under Permit No. 22845 issued by the Building Department of the own of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized under said permit did not exceed the most current accepted BOCA value of S ±5-5 7 5. 0 0 0. igned Subcribed and sworn to before me this day of A.D. 19 Q Estimated Cost S i i 4-. 9 7 5. 00 Difference: $ 5 5 II II II II_ 5, 6 8 5. 0 OX.cLv N tary Pu c 1i15peuuluil / RPPLuvdl LdLe jjy RPP.L Code Description Due Whom Code Comment 95-22845-B 98,000 B01 FOOTING 12/28/95 JFH A NOT TO BE STRIPED UNTIL 010296 B02 FOUNDATION 01/08/96 JFH D SNOWED IN E01 SERVICE 02/26/96 JFH A RELEASED P02 UNDERGROUND 04/08/96 JFF A B03 FRAMING (ROUGH) 04/18/96 JFH D CEILING JOIST OVERSPANNED MICRO LANS NEED JACKS E03 ROUGH 04/18/96 JFH A P03 ROUGH 04/18/96 JFH A B09 OTHER 04/24/96 JFH A FRAMING REINSPECT B03 FRAMING (ROUGH) 04/23/96 JFH D CHK 2ND FLR CLNG JOIST/OVERSPANNED/CHK FOR B04 INSULATION 04/23/96 JFF A JACKS UNDER MILO LAMS/CEILNG JOIST NEEDS SPRT B10 FINAL 06/06/96 JFF A 96-9422-H 5,375 96-9739-P 1 ,900 96-9475-H 1 ,900 96-13822-E 2,800 Total Est Value 109,975 Dwelling 2,030 83,067.60 Basement 1 ,029 12,759.60 Garage 484 6,001 .60 Smoke Det 7 525.00 BOCA Value 115,659.79 Difference 5,684.79 l SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 25 SUMMIT DRIVE LOT_#--I _ Reviewed B Engineering) RSK-KELLCO, INC. Date Reviewed e-ove Denied 1744 ELLINGTON ROAD,SOUTH WINDSOR,CT_ Reviewed By Planning) BP_#_22845_ Ph # (203)644-8761 Date Revie GPE&Mprov Denied Date Submitted 06/06/96 FOR C f 0 ***** As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1 . Approved building permit plan 2. Finish grading per approved building permit plan 3. Site work; i.e. trees, shrubs, dumpsters, required parking 4. Utility location; a. sanitary sewer/septic system b. foundation drain ooljwdop c. electrical & telephone d. water e. other 5. Sewer connection charge paid 6. Appropriate certification 7. Bonding 8. Planning & Zoning/ Inland Wetlands Considerations Sewer Permit No. GVR Pavement Excavation No. COMMENTS: SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 25 SUMMIT DRIVE LOT_# 9 Reviewed By Engineering) RSK-KELLCO, INC. Date Reviewed jam. Approved enied 1744 ELLINGTON ROAD,SOUTH WINDSOR,CT_ Reviewed By Planning) BP # 22845 Ph_# (203)644-8761 Date Revie Approve Denied Date Submitted 12/05/95 FOR B I DING PERMIT In accordance with the Zoning and/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include: Approved Denied N/A 1. Name, address & phone number of owner/applicant y 2. Name, address & phone number of plan preparer 3. Zoning Information - i.e. zone, open space, floodway, etc. 4. Plot Plan at 1" = 40' scale a. Subdivision reference, abutting properties, etc. b. Easements of record c. Lot description, bearings, building lines, distances, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate e. Building location with dimensions. Elevations of proposed finish floor, garage floor & centerline of road at driveway f. Elevations of gravity drainage systems, sanitary foundation drain at the house and the street J g. Tentative utility location (gas, water, electric, septic system, etc.) Jh. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements. (P.E. & L.S.) 5. Sedimentation and erosion control 6. Special Planning & Zoning, Inland/Wetlands considerations (Plans on file w/Town Clerk) COMMENTS: I PERMIT DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT f Application is hereby : TOWN OF SOUTH WINDSOR BUILDING INSPECTION DEPT.APPROVED DISAPPROVED 1540 SULLIVAN AVENUE 2 Z( 644-2511 Ext . 230 at LQ d g Inspe for Application must bepp printed or typed 1 . LOCATION OF JOB } , FEE SCHEDULE No . Street 0 - $10000 - 10.00 Floor Apt . No. Over $1 ,000 -10.00 per $1 ,000 or 2 . OWNER fraction thereof 3. ADDRESS I 49 APPLICANT -" i 5, ADDRESS 4--- Sr 6. ESTIMATED COST $ C 7 . IS THIS A CONTRACT COST Y e 8. FEE ENCLOSED $ a 9 . TYPE OF BUILDING: j RESIDENTIAL COMMERCIAL 10. TYPE OF JOB : Original Installati n Alteration/Addition/Repair RD 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11 . LOCATION OF JOB1-65--7 y sv- ,.r---14 NO. STREET APT. NO , 12 . TYPE OF INSTALLATION 13 . SIZE OF MAIN FEEDER 14 . NO . OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS 16 . NO . OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS 18 . NO . OF HEAT CIRCUITS 19 . NO. OF POWER OUTLETS 20 . NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS 22 . NO, OF POWER CIRCUITS 23. NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS 26 . NO . OF PANELS 27 . TOTAL WATTAGE 28 . NO. OF POWER FEEDERS 29 . NO. OF SWITCHES 30. A/C LOAD 31. SIZE OF POWER FEEDERS 32. NO . OF FIXTURES_ 33. TOTAL HORSEPOWER_ 34. NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : LICENSE NO. GNATURE OF APPLICANT DATE PHONE NUMBER: 11iIINy1NIVIIYP'T INSPECTOR ATE Zb TIME LOCATION INSPECTION: CODE: RESULT( /A) : BUILDING: Lf `+ ELECTRICAL: 1,00 d r PLUMBING: HVAC: OTHER: PERMIT NO. q 737 DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT Application is hereby : TOWN OF SOUTH WINDSOR APPROVED DISAPPROVED BUILDING INSPECTION DEPT. 1540 SULLIVAN AVENUE 644-2511 Ext. 230 Date ui n nspector Applications must be printed or typed 1. LOCATION OF JOBS- FEE SCHEDULE 2. OWNER: 0 - $19 000 - 10.00 3. ADDRESS: a-) Over $1 ,000 - 10.00 per $1 ,000 or 4. APPLICANT:fraction thereof 5. ADDRESS: 6. EST. COST: $ 7. IS THIS A CONTRACT COST? YES 0 ED8. FEE ENCLOSED: $ 9. TYPE OF BUILDING: L RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: ORIGINAL ALTERATION INSTALLATION ADDITION REPAIR BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: GENERAL PLUMBING 12. KIND OF INSTALLATION: 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS STYLE 15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS / 16A. NO. OF SHOWERS - 17. NO. OF LAVATORIES -- 18. NO. OF SINKS_ 19. DISPOSAL L 19A. DISWASHER 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS SIZE 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 3 x ?I--- 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? jam/,per 31. SIZE OF WATER MAIN Z 31A. SIZES OF WATER PIPING & RISERS :f 32. REMARKS AND FURTHER DETAILS WATER HEATER 33. TYPE 34. MANUFACTURER TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE LBS. 40. MANUFACTURER 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE 38. TYPE 42. MANUFACTURER c / i LICENSE N0. DATE SIGNATURE OP APPLICANT PHONE NO. J ram' ERJR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: 3 115--IF, NO.' TOWN OF SOUTH WINDSOR EST.COST: 7 5'_ BLDG. PERMIT NO.AiM 1540 SULLIVAN AVENUE FEE 4 0 . SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 0 - $19000 - $10.00 1000 or fraction LOCATION OF BUILDING 6 s& thereof - $10.00 G e Q AC44tu_f- V - 6--) o r Cam_ q [O OWNS ADDRESS TOWN PHONE NO. HVAC CONTRACTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL DL A/C 4, COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) Is HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE_C15-°F INSIDE 70 OF DIFFERENCE 2,. F TOTAL HEAT GAIN (BTUH) 3&g 6; HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): //C/L e t f—to q ro,, C_4 ,l TONNAGE COOLING CAPACITY (BTUH) Yj, 40co_ IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT) : TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: 4 01-2 1 ww03 ( STATE LICENSE - NAME S TYPE #DATE SIGNATURE OVAPPIACANT OWL t hi" APPROVED DATE I - B a R CALCULATION SHEET 1503 (Modern Methods Copyright 1971 by The Hydronics Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL A COL.S COL.C COL.D COL.E COL.F COL.G 1 ROOM E Design Water TompHLWMLWHLWHLWHLWg p• 2 ROOM DIMENSIONS, FT.U STUN per F at of 3 LENGTH EXPOSED WALLS.FT. 4 Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA U. STUN STUN BTUH STUN STUN 5 WALL CONSTRUCTION NOOM LIN.FT.OF Table 9, Line 3 x H) TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED IB ttom I table used t r L ine 5) 7 CEILING CONSTRUCTION C Table 9.L x W) g FLOOR CONSTRUCT I-ON t D_ Table 9, L x W r LIn. F t) E 9 COLD PARTITION CONSTRUCTION F Table 9, L x H)G 10 _ s 1 Wall(With Openings)O 2 Wells(With Opontngsl a X 3 Wells IWrlh Openings)or Ent.Hall 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K COL.A COLS COL.H COL.I COL.J COL. K COL.L TOTAL BTUH TOTAL ROOM i OF SUILDING RADIATION AT SELECTED p H L W N L W H L W H L W H L W DESIGN TEMP-*F2A ROOM DIMENSIONS.FT DIFFERENCE U LENGTH EXPOSED WALLS. FT. 4 WINDOW AND OUTSIDE DOOR AREAto U. STUN STUN BTUH BTUH BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9, LIno 3 x HI TOTAL 20% S TYPE OF GLASS IS ttom I table used for Line 51 7 CEILING CONSTRUCTION IFOR CONCRETE FLOOR ON GROUND OR FILL AT Table 9, L x WI GRADE LEVEL,USE LINEAR 6 FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE Table 9. L x W or Lin Ft l 9 COLD PARTITION CONSTRUCTION Table 9, L x H) 10 C I Wall IWlth Oponrngs)O 0 02Wells(With Open-ngsl 2 X 3 Wells(With Openings) r Ent Hall 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE FORM 1503 This form Is available 1r m The Hydronics Institute 35 Russo Place,Berkeley Heights,N J 07922 RESIDENTIAL AIR CONDITIONING YEAR-ROUND LOAD ESTIMATE FORM 865 Form 1605.05_F I EQUIPMENT SELECTION p A. TOTAL COOLING LOAD —Btuh 36944UNIT 53 '• CAPACITY —Btuh qg040 % B. TOTAL HEATING LOAD —Btuh UNIT CAPACITY —Btuh C. DESIGN —cfm 14,6-0 A. DESIGN CONDITIONS SUMMER WINTER 0 INSIDE DESIGN TEMPERATURE — F O db db INSIDE DESIGN RELATIVE HUMIDITY Pfo m OUTSIDE DESIGN TEMPERATURE — F db wb db rnTEMPERATUREDIFFERENCE — F db db T 0 NUMBER OF OCCUPANTS z 0 m B. UTILITIES 0 POWER SUPPLY: VOLTS PHASE—CYCLE—FUSE BOX —amp LOCATION: FROM CONDENSING UNIT —ft FROM FURNACE —ft LA ADDITIONAL ELECTRICAL SERVICE REQUIRED TO BE SUPPLIED BY WATER SUPPLY: CITY WELL OTHER QUANTITY AVAILABLE —gpm AVERAGE SUMMER TEMPERATURE — F PRESSURE AVAILABLE —pSig DISTANCE FROM UNIT —ft CONDENSATE/OR CONDENSER DRAIN: DISTANCE FROM UNIT —ft PUMP REQUIRED C. HEATING GAS: NATURAL LP OTHER SPECIFIC GRAVITY HEATING VALUE — Btu/cu ft OIL: GRADE HEATING VALUE — Btu/gal D. CONSTRUCTION TYPE CONSTRUCTION INSULATION: CEILING — TYPE THICKNESS WALL — TYPE THICKNESS SLAB — TYPE THICKNESS ATTIC: UNVENTED VENTED EXHAUST FAN — cfm ROOF: OVERHANG —ft WINDOWS: SINGLE PANE DOUBLE PANE SHADED UNSHADED INSIDE SHADING AWNINGS BASEMENT SLAB CRAWL SPACE r - YORK RESIDENTIAL LOAD FACTOIS FOR COOLING AND HEATING COOLI HEATING CONSTRUCTION TEMP. DIFFE NCE-Fdb TEMP. DIFFERENCE-Fdb f0 15 20 25 30 35 40 50 60 70 80 90 100 110 A OUTSIDE WALLS — Btuh PER sq ft OF AREA (DO NOT INCLUDE WINDOW AREA) 1 NO INSULATION 4 5 6 8 9 10 10 13 15 18 20 23 25 28 2 1" INSULATION 3 4 5 6 7 8 8 10 12 14 16 18 20 22 3 2" INSULATION 2 3 3 4 5 5 5 7 8 9 10 12 13 14 4 MORE THAN 2" INSULATION 2 2 2 3 3 3 4 5 6 7 8 9 10 11 B DOORS — Btuh PER sq ft OF AREA (DO NOT INCLUDE WINDOW AREA) 1 WOOD OR ALUMINUM 1 7 1 9 12 14 17 20 22 27 32 37 42 47 52 57 C INSIDE WALLS — Btuh PER sq ft OF AREA 1 BETWEEN CONDITIONED AND 2 1 3 4 5 6 7 8 9 10 12 14 15 17 19 UNCONDITIONED SPACE D CEILING BELOW VENTED ATTIC — Btuh PER sq ft OF AREA 1 NO INSULATION 8 9 10 11 13 14 24 30 37 43 49 55 61 67 2 2" INSULATION 3 3 3 3 4 4 4 5 6 7 8 9 10 11 3 4" OR MORE INSULATION 2 2 2 2 3 3 3 4 4 5 6 6 7 8 E CEILING WITH NO ATTIC OR UNVENTED ATTIC — Btuh PER sq it OF AREA 1 NO INSULATION 14 16 18 20 22 24 20 25 30 35 40 45 50 55 2 2" INSULATION 7 8 9 10 11 12 8 11 13 15 17 19 21 23 3 4" OR MORE INSULATION 6 6 7 7 8 9 6 8 9 11 12 14 15 16 F CEILING UNDER UNCONDITIONED ROOM — Btuh PER sq ft OF AREA 1 NO INSULATION 2 2 1 3 1 4 5 1 6 1 9 11 13 15 17 19 21 23 G FLOORS (OMIT IF OVER BASEMENT) — Btuh PER sq ft OF AREA 1 OVER ENCLOSED CRAWL SPACE — — — — — — 9 11 14 16 18 20 23 26 2 OVER UNCONDITIONED ROOM 2 3 4 5 6 7 9 11 14 16 18 20 23 26 3 OVER VENTED CRAWL SPACE 3 4 5 7 9 1 t 14 17 20 24 27 31 34 37 H SLAB FLOOR ON GROUND—Btuh PER ft LENGTH OF OUTSIDE WALL 1 NO EDGE INSULATION 32 41 49 57 65 73 81 89 2 1" EDGE INSULATION 27 34 41 48 54 61 68 75 3 2" EDGE INSULATION 22 28 33 39 44 50 55 61 J OUTSIDE AIR—Btuh PER sq ft OF TOTAL FLOOR AREA i DUE TO INFILTRATION 1 1 2 2 2 3 6 7 9 10 12 13 14 16 PEOPLE — (USE MINIMUM OF 300 NOT USED IN HEATING K FIVE 5( )— Btuh EACH L APPLIANCES —Btuh TOTAL 1200 NOT USED IN HEATING M WINDOWS — TRANSMISSION — Btuh PER sq ft OF WINDOW OPENING AREA 1 SINGLE PANE 4 8 12 1 16 1 20 1 24 1 45 1 57 68 1 79 90 102 113 125 2 DOUBLE PANE OR GLASS BLOCK 2 4 7 9 11 13 22 28 33 39 44 50 55 61 N SOLAR WINDOW LOAD —(COOLING ONLY)— Btuh PER sq ft OF AREA USE ALL WINDOW AREAS)OVERHANG O ft t ft 2 ft 3 it 4 it — FOR SINGLE GLASS SHADING 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 4 1 NO SHADING DEVICE 2 ROLLER SHADES HALF DRAWN N 20 15 1 1 20 15 11 20 15 1 1 20 15 1 1 20 15 1 1 16 3 DRAPES OR VENETIAN BLIND NE &NW 50 40 30 50 40 30 50 g3l 30 50 40 30 50 40 30 17 4 OUTSIDE VENTILATED AWNINGS E &W 80 60 45 70 48 38 60 33 52 36 28 42 29 23 18 SE &SW 65 50 35 53 40 32 40 24 27 21 17 20 15 1 1 17 A) FOR DOUBLE PANE OR STORM S 40 25 20 28 1914 20 11120 15 11 20 15 11 t6 WINDOWS MULTIPLY FACTORS BY .90. B) FOR HEAT ABSORBING DOUBLE GLASS MULTIPLY FACTORS BY 60. 2 R YORK RESIDENTIAL COOLING AND HEATING LOAD ESTIMATE-ENTIRE HOUSE COOLING HEATING REFERENCE AREA NUMBER sq ft LOAD SENSI BLE LOAD SENSIBLE FACTOR HEAT FACTOR HEAT tuh OUTSIDE WALLS A 190 S/o DOORS (INCLUDE GLASS WITH WINDOWS) B INSIDE WALLS C vV - R G3a- E CEILING OR F G dt-a 50, FLOORS OR r H OUTSIDE AIR J 3 1&3 PEOPLE (5 MINIMUM) K 5 300 1500 BLOWER MOTOR HEAT HP OR 2545 ORKW3415 APPLIANCES L 1200 WINDOWS TRANSMISSION M c;L po N OVERHANG FT. N C/SHADING G 1 2- 3- 4_ NE&NW SINGLE GLASS J E &W N 5-7' O DOUBLE GLASS N SE&SW HEAT ABSORBING_S SUB TOTAL >595-D DUCT LOSS: ATTIC-1" DUCT INSULATION-SUB TOTAL X 1.15 X 1.25 ATTIC-2" DUCT INSULATION-SUB TOTAL X i•10 X 1.20 SLAB FLOOR-INSULATED DUCTS IN ENCLOSED CRAWL SPACE, UNCONDITIONED BASEMENT OR FURRED SPACES SUB TOTAL X 1.05 X 1. 10 TOTAL SENSIBLE LOAD Lt3 ALLOWANCE FOR LATENT LOAD-TOTAL SENSIBLE LOAD X 1.30 CORRECT FOR LOW DAILY TEMPERATURE RANGE-TOTAL LOAD X 1.05 HIGH DAILY TEMPERATURE RANGE-TOTAL LOAD X 0.96 3 YORK RESIDENTIAL LOAD FACTORS FOR COOLING 11FLYWHEEL" PERIOD AND 7 POSSIBLE PRECOOLINGA. COOLING LOAD FACTORS ARE BASED ON TWENTY— I PRECOOLING TEMP— FOUR HOURS TO TAKE ADVANTAGE OF PRECOOL— It PERIOD ERATURE SLIP PERIOD W ING PERIODS AND FLYWHEEL EFFECT OF BUILD— a n DADINGANDFURNISHINGSINTHEHOUSE. THIS f' NIT CAPACITY ALLOWS THE SELECTION OF A SMALLER UNIT Z WHICH WILL PROVIDE BETTER BALANCE OF REL— ATIVE HUMIDITY AND TEMPERATURE CONTROL. 1000 OUTSIDE TEMPERATURE ON EXTREME DAY 95° B. AREAS MARKED "A" REPRESENT PRECOOLING OF 900 THE BUILDING, FURNISHINGS, AND MATERIAL 850 INSIDE TEMPERATURE ON WITHIN A RESIDENCE. THIS PROVIDES STORED— DESIGN TEMPERATURE 80F EXTREME DAY UP COOLING WHICH DURING PEAK OUTSIDE 75" THERMOSTAT SETTING 76F TEMPERATURES TENDS TO LESSEN THE INSIDE TEMPERATURE RISE. o o 0 o o © o 8 AM !2 NOON 4 PM 8 PM 12 MIDNITE 4 AM B AM SUMMER DAILY TEMPERATURE AND HUMIDITY RANGE o N ~Af 7N DAROIA i M1wRSOTA v OUTN DA[OTA wISCONSIN R.IVAC PORK w,ll wGAN b qwA Now •Ta./r ruNols INp1ANA ONIo "aledol µe KANSAS vs c so to 42CANL' St bM.+C.1' 1 .~- NGwaAeKlNTUCKTLosWSWTlNNlSS[F tiwM OKLAHOMA ARKANSAS I.OR1N AR01II'U' Kv • 1 CAROUNA lKAS A .[— l" ASARAMA OlORW b 1.•+ 10 Ay SSYI H..r T FLORIDA AREA TEMP. HUMIDITY u RANGE RANGE Its LOW HUMID Q MED. AVERAGE HIGH DRY NATIONAL WARM AIR HEATING AND AIR CONDITIONING C. IT IS ALSO NECESSARY TO ACCOUNT FOR THE SUMMER DAILY TEMPERATURE RANGE. 1. THE SUMMER DAILY TEMPERATURE RANGE IS THE AVERAGE TEMPERATURE SWING WHICH OCCURS DURING THE COOLING SEASON. THE LOAD FACTORS ARE BASED ON THE MEDIUM TEMPERATURE RANGE. CORRECTION FACTORS MUST BE APPLIED TO AREAS IN THE LOW AND HIGH TEMPERATURE RANGES. THE AREAS ON THE MAP ARE AVERAGES SO LOCAL CONDITIONS WITHIN AN AREA SHOULD BE CONSIDERED TO DETERMINE THE TEMPERATURE RANGE TO USE. 2. MEDIUM TEMPERATURE RANGE (15 F — 25 F) A) FOR LOW TEMPERATURE RANGE (LESS THAN 15 F) MULTIPLY TOTAL LOAD BY 1.05. B) FOR HIGH TEMPERATURE RANGE (GREATER THAN 25F) MULTIPLY TOTAL LOAD BY 0.96. 3. THEREFORE, A RESIDENCE LOCATED IN A HIGH TEMPERATURE RANGE AREA HAS A GREATER FLYWHEEL EFFECT THAN ONE LOCATED IN A MEDIUM OR LOW TEMPERATURE RA14GE AREA. y•Y.. .KJ...wf.COe.Ga.•.n SUBJECT TO CHANGE WITHOUT NOTICE YORKPRINTEDINU.S.A. BORG WARNER COL 10M 273 .10 Form 1605.05-F1 P.O. BOX 1592, FORK, PENNSI'LVANIA 17405 FOR,r,48FI+CE USE ONLY APPLICATION FOR HVAC PERMIT DATE: g y. , "'TOWN OF SOUTH WINDSOR EST.C ea1540SULLIVANAVENUEFEE SOUTH WINDSORs CT 06074 FEES: 644-251 - Ext. 230 0 - $19000 - $10.0C 1000 or fraction Lg"T,TO1 OF BUILDING there f - $10.00 e"'00400" ADDRESS TOWN PHONE NO. 8 ADDRESS TOWN PHONE NO. SYLS'1'EM: HEAT=TYPE OF BUILDING: RESIDENTIAL_ A/C COMMERCIAL aiTVFLATION BUSINESS _ INDUSTRIAL IFARFAMG.: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMITLBS. WARM AIR UNIT HEATF,$ (INCLUDING WOOD COAL BURNING STOVE)_ d" r OF FURL: 0X.-GPM GAS IN-PUT ELECTRIC KW i.. WQDD COAL r.01L TANK - SIZE A I,t UTION INS OUTSIDE CAPACITY of?. LPG TANK - CAFACTTY ISTINr- RAD A TT 1 ADDITIONAL ERADIATION TOTAL RADIATION, DESIGN TEMP. W9TEDE f? IF INSIDE LZF DIFFERENCE ?0 •F TOTAL HEAT LOSS (BTUR) HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DES C SE ALL UWVG WIPDi = (INCLUDING MARE & MODEL NO.): POSS RUTINd"COAA UT-BTUH) NET RATING (OUTPUT-BTUH) W A,IR.=NDITT.0NZNG,: DESIGN TEMP. OUTSIDE_•F INSIDE F DIFFERENCE TWAL HEAT GAIN (BTOH) BRAT GAIN SHEET MUST ACCOMPANY APPLICATION) 00CRIBE ALL 4-M EQUPMM (INCLUDING MAKE & MODEL NO.): 1 NAGE COOLING CAPACITY BTUH) I•I : , Q , . ' , x.:A4L AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN MMAUSE EQUIPMENT) FRESH AIR IN A.si&E (CFM) PLAX I Gr ACOOV c.,,APKICATION) for a permit to perform the following work and is to comply w:.t local 'orate,! and State of Conn.Buildin des in the performance of such w rk. inim R. D,ESCRPMv alp WORK: Lem aZct c Z41 L SE - NAME i TYPE DA SIGENGNATURE OF APPLICANT APPROVED UTE 80 as 11/88 i I = B= R CALCULATION SHEET 15W (Modern Method) Copyright 1977 by The Hydronlcs Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DA,T a COL.A COL.d COL.C COL.D COL.E/ I COL.F COL.G 1 ROOM v/ 7//? G,'7 / Q e;?Q O H L I W H I L I W H L W H L W H L W Design Water Temp. 0ROOMDIMENSIONS,FT. U Zb Z 8 OTUH o•Foot of 3 LENGTH EXPOSED WALLS,FT. o20 Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA r D Q o? dTUH dTUH dTUH dTUH dTUH 5 WALL CONSTRUCTION ROOM LIN.FT.OFTable9,Line 3 x H) 1J tfo00 Roo O OXOFROM LI1NE 12 SEDECTED6TYPE rn GLASS D0 d 0v v00IBottmoftableusedforLine5) 8 7 CEILING CONSTRUCTION Z620 C r( Teb1e 9,L a W) D '. oo—e FLOOR CONSTRUCTIONt ITable 9, L a W r Lin. F t.l 9 COLD PARTITION CONSTRUCTION F I T stile 9.L a H) Fa-f-C 1 Wall(With Openlnps) C 0 z 30o HO 60,/ -Y"Z irZ ?wall,(w,th Openings) a x / pU Z oU LZOU I OCR 1 J J3walls(With Openin egs) or Ent Half 1- J oO If TOTAL UTUH AT 70F TEMP DIFFERENCE'30U 7f 7©e ± 7000 rOKTOTtLOTUHATDESIGNTEMPDIFFERENCEOQQQe L Off L.COA _ - - _--_ COL B COL.H COL. 1 COL J COL.K COL.L TO AL dTUH TOTAL 1 1 ROOM OF dU1L•DING RADIATION Ps e a O AT SELECTED O H L W H I L W H L W H L W H L W DESIGN TEMP.* qDIFFERENCE2ROOMDIMENSIONS, FT U 8 /q / f, 'f 1 Z Q 0 3 LENGTH EXPOSED WALLS. FT. 0 WINDOW AND OUTSIDE DOOR AREA 3OZ STUH STUH 91TUH 8TUH STUH j 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9,Line 3 x H) J—/- sD/, — O --jl it - TOTAL 20% fLV 6 TYPE OF GLASS Bottom of table used for Line 5) --- Z 0 N NtFORCONCRETEFLOORO j 7 CEILING CONSTRUCTION GROUND OR FILL ATTable9.L x W) OS U co yoo GRADE LEVEL,USE LINEAR 6 FLC•OR CONSTRUCTIONt FEET OF EXPOSED EDGE Tan1e 9,L x W r Lin Ft.) 9 COLD PARTITION CONSTRUCTION fITable9,L x H) 10 -C 1 Wall(With Openings) G; 0/ O 2 Walls(With Openings) a X ,Q e J i3Wells(With Open#ngs)or Ent Hall H 1 11 TOTAL STUN AT 70F TEMP DIFFERENCE' 3 tp o 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE Q p?1!f lJ Tnss form Is available from The Hydronks Institute,35 Russo Piece,Berkeley Heights,N 1 07922 FORM 1503 j seci$-# APPLICATION FOR BUILDING PERMIT Plumbing# 25 Summit Drive D ZHVAC # Date: Y /6 Sprinkler# No. 28725 FINAL APPROVALS Estimated Cost Building ub 4 a COMPLETE RED BOXED AREAS Permit Fee 420 Engineering TYPE OR PRINT ONLY Occupancy Fee $ l o. - Affidavit 14 SIGN ON REVERSE SIDE Appr.for CO.- 3 6 v Total Fee 3c JO BUILDING D94TAENT,TOWN OF SOUTH WNDSOR,CT Additional Cost) $ The underi'Wed hereby applies to do work according to the following specifications: Job Location .96 EU M M/! P)e• Lot No. 'q Side of Street 4E;':T Zon AA36 Applicant e-b 141,4,c' 1J Tel.# 160 z 99"Zq 9 s Address o2,5 10 IK M/7- 4> • Zip Lic.# Owner_At-P nlftiPlff LFZON Address Z 5 5V44 M/r- >R. Architect Address Sq.Ft.N w Area: 1st FI. 2nd FI. 3rd Fl. Total New Area Rooms Lavatories Bathrooms Garages Purpos of this permit: ,o{er S c I K 3 O City Water Well Septic System Sewer Ins. H.O. S.P. Cert. Area Basement Garage Approved by 0 Date se Group Construction Type Revised 9/01 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building and's se i llowed. Signed I hereby apply for a Certificate of Occupanc r he work describ in th' pplication for the permit. Signed DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Inspection / Approval Date By Appl Code Description Due Whom Code Comment 28725-B 7,589 BO1 FOOTING 05/16/02 JFF A WITH OWNER AN CONTRACTOR 18 8IN PIERS B10 FINAL 06/03/02 WNB A WITH OWNER B10 FINAL 06/03/02 WNB A CLOSEOUT i FROM PHONE NO. . Jan. 05 2001 07:55AM P1 CJ1/JJ/w:Ul 1 J. L UUL+V4++JV iV W-+11..HL J.J lv i-.l Jl LOT 4 NIF ry f N o SUE W L A RSE'N f S 21 7 6'31 '0 •.W Yr,a i• 4 n AfR r Mr Sh. ...-. uvv274, H IF rJQM, SLJ ' W. LARSEN 00 je SAN.FL LOT 21516 COP? 5 L TF-*223.9T 1.3' INVot219.76 Z IP SE r sa.68' / SET N 21 *1 6.31—" r» — 24'-1$it Q5 N-12 X#S T)#NG WA s r,ox DRPE DATA. i stowN. THIE 453 ANQ ?I 4 INFORMATION vNov da gRWt3ZON u 6' LAT, INV-20-5.? tf5S40NS, ANO r TKS MAP s 06 ro os OF A r OAFS FOR 4 i• APED ANO 2%6 e7o,Q FLYNN LAND SURVEYING D APR 1 6 2tr' South Windsor BUILDING DEPARTMENT ro THE This cettit-d th,,t c, t,i n 1 1lc tr, copies of the Ge rr/cc//tcd at q i—ther wl'h ...r:,- tl,•c; ',y lht Lug' I rl; f'ndenc; its appllr,atlu:t •r li„x f a bl.ttdmj, X / per-nit flu•. I,I.,n ,s ,;, nJition than u'I71'rs }nct Or-11,111'1 s n utn;ding shall be L1,111,I'Cd v.lth t7 onUttlon<rily ',tjproved These flied with Bu 1 n P.,ct Clark tat zl_— No. CE,k i "11..Ai i0i1 O ;UONING COMPLiAi`.CE Proposed building;s;, uses) rand/or c:7 p ^Till•I 1 I r,J l,1-•t., 4 t. /1 l 3. V, Date LIAO Zom,,g Enforcc-ment Gfi,'cer __