HomeMy WebLinkAbout25 Green LaneTown Of South Windsor
64W_1 Building Department
Location Catj,Building Permit# o2 7(6
SWIMMING POOL REQUIREMENTS:
This list is not all inclusive;please refer to pool packet. 0006 10717i11V
ll"A 48"barrier will be provided to protect the pool access. Including a temporary fence y V G/
for inground pools prior to filling.
c
t cceAss gates will be self closing and self latching(if less than 54"high they shall be on Y Q!/L C (
V/C)
0 1 side and be protected within 18"of release mechanism).the p o p
Doors providing direct access to the pool shall either have an al a self closing self fit/ N /C)
P 8 P 8 3 Y C9
latching device 54"above the floor,or a safety cover over the pool.
PNo receptacles within 10' of pool.(locking type receptacle for pool equipment must be _6y 7"'
at least 5 from pool and GFCI protected).
metal parts ofpool structure,fixed metal parts within 5'of pool,pump mown etc.,
shall be bonded with a minimum#8 solid copper wire.
v
Convenience GFCI receptacle shall be provided between 10' and 20' from pool. Y
LoTrench depth for 20 amp. circuit to pool equipment shall be 12"minimum. 6 y f r
V'A surface pool alarm shall be installed pursuant to Public Act 99-140.6/Y
1VY All swimmingpool s must be equipped with a time clock. Y L C
P pumpsP
Heated pools require a pool cover unless over 20%of the heating energy is from non-depletable sources. Q W/l)
REOUIRED SWIMMING POOL INSPECTIONS:
The following is a list of inspections that need to be performed prior to the continuation of work. Requests for
inspections can be made by calling the Building Department at 644-2511 ext. 230.
R
1. TRENCH AND BONDING-Electrical trench depth verification and bonding of pool and metal appurtenance Y
including metal reinforcing for gunite pools.
2. FINAL ELECTRICAL-Location of equipment and GFCI protection. Convenience outlet provided.
3. FINAL-Swimming pool access protection must be provided before pool.can be used.
Each swimming pool installation requires a Building and an Electrical permit. Additional permits and inspections
are required for pool decks.
I have read and understand the requirements listed above.
Applicant Signature_t; Date 3 -- ty0
Homeowner Signature Date 7- .2- 03