Loading...
HomeMy WebLinkAbout25 Green Lane (4)DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR l r 3BUILDINGDEPARTMENT APPROVED 1540 SULLIVAN AVENUE 644-2511 ext. 230 Bldg.Permit# s 3 s 0 9 a7 to Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: C 51 4-re e-o, kg.,e 0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= 15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. 3 JJ APPLICANT 3 APPLICANT ADDRESS APPLICANT PHONE# y/3 ,-$— 8 eo F O W N S At Zail.-Af 12tA - q OWNER ADDRESS e-zL nS OWNER PHONE Fle - LO I C ESTIMATED COST$ /j 0 IS THIS A CONTRACT COST? s No f• FEE ENCLOSED$ rl 1 i TYPE OF JOB• SOR•CO New Installation Alteration/Addition/Repair Revised 410IH2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OFBUILDING: litEATING RESIDENTIAL C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC AWARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE __(o2F INSIDE F DIFFERENCE F TOTAL HEAT LOSS(BTUH) 91 van°F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&M DEL NO.) n1 K,e, / r 1C L,yc ,da;r WQ:/ i clr,s-r L'd/ i . 0) GROSS HEATING CAPACITY(INPUTBTUH) r d° NET RATING(OUTPUT—BTUH)130 0"70 TYPE OF VUEL OIL—GPM OIL TANK LOCATION:I INSIDE OUTSIDE CAPACITY GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING J DESIGN TEMP.OUTSIDE_?°F INSIDE V °F DIFFERENCE OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) jl yy 3 T / 5--ri/r• d/t a-r f O 3GTi4Z TONNAGE (D COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF UCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT AIOCZ41 w DATE 7 `03 RIGHT-J SHORT FORM Enure Hous DEBLOK HTG J b: 10-23-02 ALLEN ST.EAST LONGMEADOW,MA Phone:413425-88M Project • For: RESIDENCE LOTA GREEN LANE, SOUTH WINDSOR, CT D- • Htg CIg Infiltration Outside db(OF) 6 88 Method SimplifiedInsidedb(OF) 70 75 Construction quality AverageDesignTD(OF)64 13 Fireplaces 0DailyrangeM Inside humidity(%) 50 Moisture difference(gr/lb) - 28 HEATING EQUIPMENT COOLING EQUIPMENT Mak Make RUUD AIR CONDTradeTradeRuudUAKASeries UAKA-030JA RCBA-3765 Efficiency 80.0 AFUE Efficiency 10.0 SEER Heating input 0 Btuh Sensible cooling 19740 BtuhHeatingoutput0BtuhLatentcooling8460BtuhHeatingtemperaturerise0OFTotalcooling28200BtuhActualheatingfan1000cfmActualcoolingfan1000cfm Heating air flow factor 0.024 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh Space thermostat Load sensible heat ratio 88 % ROOM NAME Area Htg load Clg load Htg AVF Cig AVFft2) Btuh) Btuh) cfm) cfm) LIVING ROOM 196 5201 3003 126 158FAMILYROOM25659164433144234FOYER1685550130913569DININGROOM19652012013126106KITCH/DINE 272 8368 2054 203 108LAUNDRY/BATH 192 4801 3831 117 202DEN14460972324148123 Entire House d 1424 41134 18966 1000 1000Vntilationair00 Equip.@ 0.93 RSM 17639Latntcooling2678 TOTALS 1424 41134 20317 1000 1000 6o+dt&-vsws haw"M wwwmwy 0rw1*"w Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wng htsoft R%ft,%b Re•wenw"-5.o.w RSRRumw7 2=-oa2 317:10:44AE& Projec i-mr Page 1 RIGHT! SHORT FORM Entire House DEBLOK HTG/COOL Job: 10-23-02 ALLEN ST,EAST LONGMEADOW,MA Phone:413-5254M Project • For. RESIDENCE LOTa GREEN LANE, SOUTH WINDSOR, CT Design Information Htg Cig Infiltration Outside db(°F) 6 88 Method Simplified Inside db(OF) 70 75 Construction quality Average Design TD(°F)64 13 Fireplaces 0 Daily range M Inside humidity(%) 50 Moisture difference(gr/lb) - 28 HEATING EQUIPMENT COOLING EQUIPMENT Make RUUD AIR COND Make RUUD AIR COND Trade Ruud Trade Ruud UAKA Series UGRA-04(E,N)MAES UAKA-030JA RCAH-Z037 Efficiency 93.5 AFUE Efficiency 10.0 SEER Heating input 45000 Btuh Sensible cooling 19320 Btuh Heating output 42000 Btuh Latent cooling 8280 Btuh Heating temperature rise 38 OF Total cooling 27600 Btuh Actual heating fan 1000 cfm Actual cooling fan 1000 cfm Heating air flow factor 0.034 cfm/Btuh Cooling air flow factor 0.055 cfm/Btuh Space thermostat Load sensible heat ratio 84 % ROOM NAME Area Htg load Clg load Htg AVF Clg AVF ft2) Btuh) Btuh) cfm) cfm) MASTER BEDROOM 234 6985 5200 241 286 MAST BATH/WIC 252 4196 1221 145 67 BEDROOM 2 FRONT 196 4700 3787 162 208 BEDROOM 2 REAR 168 4919 2013 170 111 BATH UP 112 1483 444 51 24 BEDROOM 4 322 6732 5510 232 303 Entire House d 1284 29014 18176 1000 1000 Ventilation air 0 0 Equip. @ 0.93 RSM 16903 Latent cooling 3449 TOTALS 1284 29014 20353 1000 1000 bnla:tai,c values have lean mantaally ovenwkien Printout certified by ACCA to meet all requirements of Manual J'lth Ed. wnghtSaft Right-Suite Residential 5.038 RSRRUD26387 2002-Oct-23 17-41 09 RIGHT-J LOAD AND EQUIPMENT SUMMARYEnureHouse d DEBLOK HTG Job: 10-23-02 ALLEN ST,EAST LONGMEADOW,MA Phone:413a25- M Proiect Information For:RESIDENCE LOTS GREEN LANE, SOUTH WINDSOR, CT Notes: FIRST FLOOR Design Information Weather: Hartford, Brainard Field, CT, US Winter Design Conditions Summer Design Conditions Outside db 6 OF Outside db 88Insidedb70OFInsidedb75 ° F Design TD 64 OF Design TD 13 OF Daily range MRelativehumidity50 Moisture difference 28 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Building heat loss 41134 Btuh Structure 18966 BtuhVntilationair0cfmVentilation0BtuhVntilationairloss0BtuhDesigntemperatureswing3.0 OFDesignheatload41134BtuhUsemfg.data n Rate/swing multiplier 0.93InfiltrationTotalsens.equip. load 17639 Btuh Method Simplified Latent Cooling Equipment Load SizingConstructionqualityAverage Fireplaces 0 Internal gains 460 Btuh Ventilation 0 BtuhHeati V n Cooling Infiltration 2218 Btuh Vorealume)ft3 1421 1423 Total latent equip. load 2678 Btuhoe1416014160AirChanges/hour 1.0 0.5 Total equipment load 20317 BtuhEquiv.AVF(cfm) 236 118 Heating Equipment Summary Cooling-Equipment Summary Make Make RUUD AIR CONDTradeTradeRuudUAKASeries UAKA-030JA Efficiency 80.0 AFUE RCBA-3765Efficiency 10.0 SEERHeatinginput0BtuhSensiblecooling19740 BtuhHeatingoutput0BtuhLatentcooling8460BtuhHeatingtemprise0OFTotalcooling28200BtuhActual-heating fan 1000 cfm Actual cooling fan 1000 cfmHeatingairflowfactor0.024 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh Space thermostat Load sensible heat ratio 88 % Bold/Jt tic values have been manually ovwrkkbn Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wngi tsof't Right-Suite Residential""5.0.38 RSRRUD26387 2002-Od 2317:10.44Projedl.rsr Page 1