HomeMy WebLinkAbout25 Evans Crossingr
D::ISION APPLICATION FOR HVAC PERMIT PERMIT#
eby:
TOWN OF SOUTH WINDSOR 7
BUILDING DEPARTMENT
1540 SULLIVAN AVENUE Bldg.Permit#
644-2511 ext. 230
g Inspector
Application must be printed or typed
Location of Job:
Fo
EE SCHEDULE
1,000=$13.00 Street No. Street Lot No.
Over$1,000=
13.00 per$1,000
ny fraction thereof Tenant Designation Apt.No.
APPLICANT AW r f 4 f c
APPLICANT ADDRESS 11 C S I-.S'c C 77-
L 6 a 24/
APPLICANT PHONE# 1 S- ?
OWNER 0,011"orj 4- Z G d/v 5•'
S"Cq 1'j OWNER ADDRESS f/
k OWNER PHONE
ESTWATED COST$ 300 , 00
V
IS THIS A CONTRACT COST. Yes No
FEE ENCLOSED$ / 7 V` CJD
l 1
pR. O TYPE OF JOB:S C
V-New Installation
0 Alteration/Addition/Repair Revised 5101
APPLICATION FOR HVAC PERMIT (Continued from reverse side)
TYPE OF SYSTEM: TYPE OF BUILDING:
HEATING RESIDENTIAL
4 A/C COMMERCIAL
VENTILATION INDUSTRIAL
HEATING
STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
HYDRONIC WARM AIR UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT BTUH)
TYPE OF FUEL
OIL--GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY
GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE /00 OF INSIDE 7/ OF DIFFERENCE 2f OF
TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COO ING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
a. S1 1•1 0 re-e-t 2.
TONNAGE 9 r1`Ari.9, COOLING CAPACITY(BTUH)
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
8 u f.Fs+ /f 'od+1.
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK e7e,4,c f r
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
3 37 9 2-
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT- DATE 2,
F. W. Webb - WebbConnect Online Ordering System Page 1 of 2
nwu
PM&AMGl
For WebbConnect II Support call Webmaster at 781 272 6600,8AM-5PM
I
Building Information Rooms
Name Islam Click on room label to edit
Location 25 Evans Crossing Exterior
South Windsor,Ct. wall floor
Label Length height sq. ft.
Upper design 100
temp.office FKS248
Lower design -10 1 foyer 170.10 8 129.28
temp.kitchen/family 14.8 8 503.2
Room temp. 71 rm
Leeway as % 10 1 T.V. room 1[27 J1 8 1181.04
Number of 5@400 dining/living 49.2 8 534.6
people rm
Ground 50 master bath ID.3 135.E
temp.
master bed rm 35 8 300
Cooling air 50 IF
Warming air 120
bed#2 1131
gg uuccss
Bed#3 1114 154
5*Y+.v
f .. Aw''iK'C{krli.'`'a:Gvt•`5`%nPf y 5`u? k
bed#4 127.3 185
2nd. floor 17 8 204
foyer
1"3EONa
Ca}culgt}otq
Building Rooms
n nr nnF-1
http://webbeonnect.fwwebb.cons/bin/f wkf?wc.hc.room.process 5/23/2003
F. W. Webb - WebbConnect Online Ordering System Page 2 of2
Gain BTU 42604 Gain Gain Loss Loss Base
Loss BTU 16654411Label BTU CFM BTU CFM Board
office 2437 81 4065 77
Gain CMF 1419
Loss CFM 1258 Tfoyer1113181144 3248 61
Base Board 120
kitchen/family 7464 249 8940 169 16
rm 11
Tonnage imT.V. room 4763 159 8089 153 114
dining/living 26
rm
master bath 1273 42 3523 67
master bed rm 5226 174 7316 138 113
bed#2 3071 102 4912 93
Bed#3 2460 82 3427 65
bed#4 2111 70 4214 80
2nd. floor 2942 98 3913 74 7
foyer
For WebbConnect II Support call Webmaster at 781-272-6600, 8AM-5PM
Back to Login I Current Order Pad I All Order Pad Entries I Order/quote/AR Info
Home I About F.W.Webb I Products I Locations I Programs/Services I News
Copyright®1999-2002 F.W.Webb.All Rights Reserved.
http://webbconnect.fwwebb.com/bin/fwk9we.hc.raom.process 5/23/2003