Loading...
HomeMy WebLinkAbout240 Orchard Hill DriveTO THE BUILDING INSPECTOR of dw APPLICATION FOR PLAN EXAMINATION ANDTOWNOFSOUTHWINDSORCOI1N. BUILDING PERMIT IMPORTANT — Applicant to complete all items in sections: 1, 11, III, IV, and IX.O I• AT (LOCATION) P- .v d kQlf fid )+I L L Ale Ef ZONING LOCATION NO.) STREET) 1 pV C C OF BETWEEN AND BUILDING CROSS STREET) CROSS STREET) LOT SUBDIVISION LOT BLOCK SIZE V1 II. TYPE AND COST OF BUILDING — A11 applicants complete Parts A — D v A. TYPE OF IMPROVEMENT D. PROPOSED USE — For"'Wrecking" most recent use M M 1 New building Residential Nonresidential 2 Addition(If residential, enter number 12 One family 18 Amusement, recreational of new housing units added, if any, 13 Two or more family — Enter 19 Church, other religiousinPartD, 13) number of units— — — — --),.20 Industrial3 Alteration (See 2 above) 14 Transient hotel motel, mo 21 Parking garage4 Repair, replacement or dormitory — Enter number 5 Wrecking (1J multifamily residential, of units ——————— — --Ir 22 Service station, repair garage enter number of units in building in 15 Garage 23 Hospital, institutional Part D, 13) 16 Carport 24 Office, bank, professional 6 Moving (relocation) 17 Other — SpeciJy 25 Public utility 7 Foundation only 3 26 E] School, library, other educational B. OWNERSHIP i 27 Stores, mercanfile 8 [WPrivate (individual, corporation, 28 Tanks, towers nonprofit institution, etc.) 29 Other — Specify 9 Public (Federal, State, or local government) C. COST Omit cents)? Nonresidential — Describe in detail proposed use of buildings,e.g., food processing plant, machine shop, laundry building at hospital, elementary 10. Cost of improvement,••.••..•....... school, secondary school, college, parochial school, parking garage for, department store, rental office building, office building at industrial plant. To be installed but not included If use of existing building is being changed,enter proposed use. in the above cost a. Electrical...................... b. Plumbing ...................... c. Heating, air conditioning......... d. Other(elevator, etc.)............ 11. TOTAL COST OF IMPROVEMENT is zu III. SELECTED CHARACTERISTICS OF BUILDING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS 30 Masonry (wall bearing) 40 Public or private company 48• Number of stories................ 31 Wood frame 41 Private (septic tank, etc.) 49• Total square feet-of floor area, all floors, based on exterior 32 Structural steel dimensions .................... 33 Reinforced concrete H. TYPE OF WATER SUPPLY 34 Other — Specify 42 Public or private company 50 Total land area, sq.ft. ........... 43 Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES F. PRINCIPAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL 51. Enclosed ....................... 35 Gas Will there be central air 52. Outdoors....................... 36 Oil conditi ning? L. RESIDENTIAL BUILDINGS ONLY 37 Electricity 44 Yes 45 N 53. Number of bedro ms.............. 38 Coal 39 Other— Specify Will there be an elevator? 54. Number of Full.......... 46 Yes 47 No bothr ma Partial....... NOTES and Data — (For department use) IV. IDENTIFICATION — To be completed by all applicants Name Mailing address — Number, street, city, and State ZIP code Tee. No. Iwner or i ftNl J L' L 6 44— essee O s6 ft &), ontractor rchitect or " ' 15 Le ngineer fhe owner of this building and the undersigned agree to conform to all applicable laws of this jurisdiction. iign ture of applicant Address Application date ems. aqo GL J-71- 00 NOT WRITE BELOW THIS LINE f. PLAN REVIEW RECORD — For office use Plans Review Required Check Plan Review Date Plans B Date Plans B NotesqFeeStartedyApprovedy BUILDING PLUMBING MECHANICAL ELECTRICAL OTHER l. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Permit or Approval Check ObDatetaied Number By Permit or Approval Check Obtainedate BOILERNumber By BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER II. VALIDATION Building 9136Permitnumber Bui(ding 6 19 75PermitissuedNOV• Building Permit F e $ 3.00 Approved by: r fr TITLE VIII. ZONING PLAN EXAMINERS NOTES DISTRICT USE FRONT YARD SIDE YARD SIDE YARD REAR YARD NOTES IX. SITE OR PLOT PLAN — For Applicant Use N - d.eb TOWN OF SOUTH WINDSOR BUILDING PERMIT Date Jan 21 19 75 Fee Paid $.18.0.00 Est. Value $.30,000.00 Permit N?8759 on the side of Lot #7 Orchard Hill Drive Street Street No. 240 Owner Herbert Wanza Applicant Herbert Wanza CERTIFICATE OF OCCUPANCY ISSUED: Date No. 4550 Fee Paid $ 3.00 CLASSIFICATION Dwelling BUILDING PERMIT N® 8759 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn. 'Tau 21 1975, 94io t' ' to Tertify, That Hierbert Wanza is hereby granted permission to Dwelling at estimated value of $30 s 000.00 on the side of Lot #7 Orchard gill Drive Street on land owned by Herbert Wanza Said work to be as described in Application No. 8759 and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR. I Jan 21 19750 Buillng Inspector. Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compeller: to reason therefor." INSPECTION REPORT Permit # As Job 1 Footing 2 Foundation /-a3_75- 3 Framing 3 7 75- -&IA-- 4 Wirin 3- 2`- 7S- 6,d 3-a5--7s xt 8 5 Plumbing t 3-.R 03 6 Heating -o?- ?j 7 Lathing 8 C.O. C/O i i Permit No. TOWN OF SOUTH WINDSOR SOUTH WINDSOR, CONN. I Permit X 4550 I Certificate of Occupancy THIIIIIIIr`1S.TT2CERT, 'Y that the ' at No:-'tt va of South Windsor, Connecticut, has I been erected and completed in accordance with the Iguilding code and Zoning Regulations of the Town of South Windsor, and is hereby approved for occupancy.,. Building inspector Awner, Builder Fee Paid Date c 19 ' ' 5688 P ELECTRICAL APPLICATION Application No. 5999 on the side of Orchard Hill Drive Street Street No. 240 Lot P . Owner Herbert Wanza Electrician Jos .Zingarelli FILED IN OFFICE OF The Building Inspector 3-25-75 19 INSPECTION. No Electrical Work shall be started until a Per- mit is granted by the Building Inspector. In New Buildings no wiring shall be started until the plumbing and heating pipes, and the ere tops (if of wood) are installed, without a special permit from the office of the Building Inspector. PLICATION FOR PERMIT TO DO ELECTRICAI. WORK. No. .............. r..99.... ........ Permit No. .............56 a 8 TO THE BUILDING INSPECTOR of the TOWN OF SOUTH WINDSOR, CONN. hereby make application tq perform Electr cal Work according to detailed description below. All provisions of the Rules for Electrical Installation, Section 48, Building By-Laws, shall be complied with whether specified herein or not. South Windsor, Conn., 04....f............... 191 Sign here Address ............... ........... ............................ Location .................. ....1...?!. .... . ........... ...., Side of ....................................................................................................................._........_. Nature of Building How many stories .................... .........................._............._......................... New or old Building .................... How many families Kind of Installation ................ How many Stores ........................................._.........._....._.._.._....._........_........... Owner .................................................................................................................__............... Address ............................................................_.................._._........ ..... Architect ........................................................................ .... .................................. ...... Address ................................................................._.._....__.w..__._.. / Builder Address r/cC Electrician ... .. .......... ....... ............ ....................................... Address 1 ............../.....`? `•• Size of Main Wires ...........r. ...-............_ No. of Light Loops ...............1....... ..... .... No. of Heat Loops No. of Power Loops No. of Light Outlets .... .!,?` ............. No. of Heat Outlets ................... ... ... ..... .... No. of Power Outlets ..................................... Nod of Light Circuits ../. ................. No. of Heat Circuits .... . ..... . . .. ........ No. of Power Circuits ................ ................. N . of Sockets ......... .......1.. ... .. ............ No. of Heat Receptacles ......... .. ..... ... No. of Motors ......................... ............ .................. No. of Panels .................. ............. ................ .. Size of Heat Circuit ....... ........... .............. No. of Power Receptacles ......................... No. of Switches 3 Total Wattage Size of Power Circuit Total Horsepower ............ ........................... No. of Straight Electric Fixtures ......../.75............................... No. of Combination Fixtures ........................................... .............. No. of Receptacles No. of Cord Drops ............................................................................................... r Remarks: For other kind of Installation .................. .. .............. ............. ............... S...sJ" 1.................................. Estimated Cost ...a` 2".ej..d... ... G 4703 PLUMBING APPLICATION Application Nat 4492 on the ... ...___ side of Lot .#7 Orchard Hill Drive Sant Street No. ..._ 240 Owns Herbert Wanza Plumber _.Herbert W an z a Filed in Office of The Build'mg Impectar May 12 191— No person shall construct, add to or alter my portion of the drainage system of ace' buiHiog except to repair lealms) until a Pkrmit is Stowed by the Building Inspector. L+4.92 47034ApplicationNo........................................... Permit No. ...........................I.......... TO THE BUILDING INSPECTOR of the TOWN OF SOUTH WINDSOR, CONN. hereby make application to perform plumbing according to detailed description below. All provisions of the Rules for Sanitation, By-Laws, Sections 33 to 47 inclusive, shall be complied with whether specified herein or not. South Windsor, ...I`..'........................1..Z.,...................... 19 T. Sign here ....................................... .................................. Address .......1.Ir.......ortc.Mk,AE-r Qhl! .,...... lC•.......5.....Win' Location .4,. "t'................ O.I[Grl fl't7................1rl t?1 t.L.l.................... side of ...........S..A.ta.rm................................................................ Street Nature of Building .......... A.................................. How many stories .. ......TW.G............................................................ Owner .......WA.A)ZA........... 9.04.T'•................Cr.'.o....:I.. ....... Address ...I.J.0.....A..1.C.C.h1. .4.kAiu........PA., ....5*...S . W 0)Wx. Architect .. ................................... ........... ............................... .................... Address ........ ........................................................................................................... Builder 0 OST.*. .................cv A................. Address .........!.!........P.4............. Plumber ..... . `1 Vic- T..........t..JAvJ. A........T ................ Address .........H............................... .................................A...............K............ DRAINAGE CESSPOOLS, How many !,.1ov. Where locatedPP-q4k.............. Are they water tight .. . . ......................................................................... Of what materials are they built ...................................................... Size o Kind ofipipefromhousetocesspool . . ...................................pipe ............. .................................................................................... MAIN DRAIN IN CELLAR, Material .......i r t;iar....... Diameter ............4...................................... Above or below cellar bottom .. Bid• .-! ..:........................... .............. ...................................................._.........................................................I.......... SOIL PIPES, Material .......0 S- ........ Diameter ............4..`H................................. Diameter .........I.v-e—.1....z.~........4.....3.h..WASTE PIPES, Material ......... L1. T<<........................ TRAPSy Type proposed to use is ... .. .. ........... ... .. .. ................ RAIN WATER LEADERS, where do they run to .....S.M.4.(................ry...........4. .! .................................................... REFRIGERATOR WASTES, where do they run to ... .... .00.o.IZ................................................................................ ............................... TANK OVERFLOWS, where do they run to . . .. 64! a FIXTURES oN WATER CLOSETS, How many . ................&........................ Where located ..1111w.1N. V..................M.*. ..........?4.'.r''......... Distance from trap to vertical soil pipe ........1.0....................... Pattern L.O.Ad.4....... ............................................................... WASH TRAYS, How many ......................0.Ok).C................ Where located . . ..................................... ................................................ SINKS, How many ...................................................t..................................... Where located .. --K.L.Y'aA.................................................. BUTLER'S SINKS, How many .................W..Mv..q............... Where located.. ...... ...................................................................................... REFRIGERATOR SINKS, How many.. .....#4.0+ 4........ Where located .................................................................................................... LAVATORIES; How many ...............................Zs............................. Where located .......L,.4U. .......D.N. ............. .1. .......5A-1'='r BATH TUBS,How many...................................I................................... Where located ...............A.#.#...................t3A..:xiL-1............................. URINALS, How many ...............................k Q.&A...................... Where located ..................................................................................................... Are water closets and urinals to be local vented . .. . ........ . .. If not, is there a window in outer wall of room where same are to be located ........... Estimated Cost ......I .Q.-..'`................. Application For 4610 _. 4389 DEPARTMENT DECISION eS • Permit :n 3 APPLICATION IS HEREBY:DEPARTMENT OF UCME3 AND YN9P1wmil". APPROVED DISAPPROVED TOWN OF SOUTH WINDSOR 0 Cd 9/17/75 o,4 51 00 4) DATE qr CHIEF IN R 4APPLICATIONS MAST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE SEL00 C c os. 1. LOCATION OF J o 240 Orchard Hill Drive cd S: NO. STmw Cd Q Lot #7 LOT NO.FLOOR AR. NO. OLV s. OWNER Herbert Wanza a S. ADDRESS 190 Orchard Hill Drive be o 3 0 4.PHONE Ci S. APPLICANT Herbert Wanza s. ADDRESS Lo& #7 Orchard Hill Drive PHONE w 'o S. LICENSE NO. A. 0 w s. EXPIRATION DATE OF LICENSE 10. ESTIMATED COST : 1 500. 00 1 g IS THIS A CONTRACT COWTJ YES13 NO b0 1:. FEE ENc.LosEo : Permit 8759 as 1s. TYPppE OF BUILIHNQ: ba iJ RESIOEMTIAL COMMERCIAL i' cis a 14. TYPE OF JOB: INDUSTRIAL x ALLATION ADDITIONAON REPAIR Y, i r y APPLICATION FOR HEATING PERMIT (Continued from Rev roe Side) I b L -711. LOCATION OF JOB O '' ''', I-'- h NO. STREET FLOOR AFT.NO. y 12. TYPE OF INSTALLATION: LJ OIL BURNER ELECTRIC VENTILATION SPRINKLER GAS BURNER Cl STACK INCINERATOR MISCELLANEOUS IDENTIFY SIZE InLOCATIONSIZE1SIZE 13. OF TANK 7+ ' OF TANK ' '-j OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE An; r i,1 G1 s 11 ,•:i BOILER OR FURNACE MAKE AND NO. I ?i!') '}i' 8.T.U. OR SQ. FT. NETS,0 OR SQ. FT. GROSS,"_FIRING RATE I FLOORS TO BE HEATED NEW 0 -060-BUILDING INSULATED — YES OR-NO Y'- TYPE OF WALL r INSULATION F<%t, 'f-' 3`-' ROOF OR CEILING 3f INSULATION J` AVG. SYSTEM WATER TEMP. NO ° B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE 0 r i1'I.! - FAH RENHEIT 'U I •}4 `• MAKE OF RADIATION: BASEBOARD, COPPER CONVECTORS, OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U. r;.;r' ry. 7 DESCRIPTION OF WORK 15. TO BE DONE: IS. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS): R oM size wlNDow, AREA — SQUARE FEET f,.T.u. s.T.u.H DISTRIBUTION INSTALLED AND DOOR, VOLUME TOTAL TOTAL ROOM L w N AMD hl GROSS GLA„ NET WALL CEILING FLOOR CU.FT. AT MPF CON TOTED J F REGISTER C QQ TYPE AND,IZE RAD. OR LEADER SIZE < WALL f' to INFILT.) DIFF. ('•'•F P SI d SO. FT. FREE AREA 160 U Li I 1 I o ` 1 IL J S C U ', '0 JP 9 ccq4 Z z4 -zoo S" i5c o h1rI;1 - Z 3 8L 3 S— t i r ' r I Y ARz R' 4• • L_0 1 z GU TOTALS 11, r A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND B.T.U./HR. r C. PIPING, OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY: " % NAME ADDRESS SUBCONTRACTORS AND IS. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE(OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. 7 DATE SIGNATURE OF AFNLICANT TO THE BUHMING INSPECTOR of aw APPLICATION FOR TOWN OF SOUTH WMIDSM CORM. PLAN EXAMINATION A N D BUILDING PERMIT IMPORTANT — Applicant to complete all items in ctions: 1, 11, 111, IV, and IX.O I ZONING AT (LOCATION) vz DISTRI414A30 LOCATION NO.) STREET) OF BETWEEN AND BUILDING CROSS STREET) CROSS STREET) LOT SUBDIVISION LOT-7—BLOCK SIZE Vf II. TYPE AND COST OF BUILDING — A11 applicants complete Parts A — D I X A. TYPE OF IMPROVEMENT D. PROPOSED USE — For"Wrecking" most recent use M 1 FNew building Residential Nonresidential 2Addition(If residential, enter number 12 One family 18 Amusement, recreationalofnewhousingunitsadded, if any, in Part D, 13)13 Two or more family — Enter 19 Church, other religious number of units— — — — --)P. 20 Industrial3 Alteration (See 2 above) 14 Transient hotel, motel, 4 Repair, replacement or dormitory — Enter number 21 Parking garage 5 Wrecking (If multifamily residential, of units ——————— — --jo- 22 Service station, repair garage enter number of units in building in 15 Garage 23 Hospital, institutional Part D, 13) 6 Moving (relocation) 16 H Carport 24 H Office, bank, professional 7 H Foundation only 17 Other — Specify 25 H Public utility 26 H School, library, other educational B. OWNERSHIP 27 H Stores, mercantile 8 D4 Private(individual, corporation, 28 Tanks, towers nonprofit institution, etc.) 29 Other — Specify 9 H Public (Federal, State, or local government) C. COST Omit cents) Nonresidential — Describe in detail proposed use of buildings, e.g., foodIr processing plant, machine shop, laundry building at hospital,elementary 10. Cost of improvement................ Sq%2CPAP 0 school, secondary school, college, parochial school, parking garage for, department store, rental office building, office building at industrial plant. To be installed but not included If use of existing building is being changed, enter proposed use.in the above cost a. Electrical....................... n b. Plumbing ...................... c. Heating, air conditioning......... d. Other(elevator, etc.)............ 11. TOTAL COST OF IMPROVEMENT Om III. SELECTED CHARACTERISTICS OF WILDING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS 30 Masonry (wall bearing) 40 KPublic or private company 48. Number of stories................ —774,w C 49. Total square feet of floor area,31 Wood frame 41 Private (septic tank, etc.) all floors, based on exterior 32 H Structural steel dimensions .....................Q 33 Reinforced concrete H. TYPE OF WATER SUPPLY 50. Total land area, sq. ft. ...........34 Other — SpeciJy 42Limi Public or private company p 43 Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES F. PRINCIPAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL 51. Enclosed ....................... ct 35 Gas Will there be central air 52. Outdoors....................... 7=`4'p 36 X Oil c nditioning?L. RESIDENTIAL BUILDINGS ONLY 37 Electricity 44 H Yes 45 EZ No 53. Number of b drooms.............. 38 Coal 39 Oth r— Specify Will there be an elevator? Full.......... 54. Number of 46 H Yes 47 50 N bathro ms partial........ NOTES and Data — (For department use) IV. IDENTIFICATION — To be completed by all applicants Name Mailing address — Number, street, city, a st a t ZIP code Tel. N 1. 174tV,001? F- 0Owneror Lessee 4 ro 2. Contractor 3. Architect or Engineer The own r of this building and the undersigned agree to conform to all applicable laws of this jurisdiction. Signature of ap lica Address i Application date ale"z DO NOT WRITE BELOW THIS LINE V. PLAN REVIEW RECORD — For office use Plans R vi w R quired Check Plan Fee Review DaSteartePllaans By DateApp Plans By Notes BUILDING PLUMBING MECHANICAL ELECTRICAL OTHER 1 1$ VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Permit or Approva I Check O Date bta ned Number By Permit or Approva I Check Date Obta ned Number By BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER VII. VALIDATION Building 8759Prmitnumber Bui(ding Permit issued Jan 21 19 Bui Iding Permit Fee $ 180.00 Approved by: TITLE VIII. ZONING PLAN EXAMINERS NOTES DISTRICT USE FRONT YARD SIDE YARD SIDE YARD REAR YARD NOTES IX. SITE OR PLOT PLAN — For Applicant Use N 1 •9 s „A 4 x a s F g a a y Y § a;>w--; _s b¢ s YK iir 4c.Y"vi4- y+ f I TOWN OF SOUTH WINDSOR BUILDING PERMIT 4 Date Nov. 6 19 75 Fee Paid $ 3'00 Est. Value 00.00 Permit NO 9, 136 on the side of Orchard Hill Drive Street Street No. 240 Owner Barry Nance Applicant Barry Nance CERTIFICATE OF OCCUPANCY ISSUED: Date No. Fee Paid $ CLASSIFICATION Greenhouse 12 x 23. BUILDING PERMIT N! 913-6 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn. tJo y. 6 ig 75. 94is 'to to T erttfil, That Barry dance is hereby granted permission to Greenhouse 12 x 23. at estimated value of $ 2 0 0.0 0 on the side of 240 Orchard Hill Drive Street on land owned by Barry Nance Said Work to be as described in Application No. 94,36 and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR. Iss iJ ov. 6 9 75 AuildKg Inspector. Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compelled to reason therefor." INSPECTION REPORT Permit # Job ;Zyo 1 Footing '-- 2 Foundation 7 3 Framing 4 Wiring 5 Plumbing 6 Heating 7 Lathing 8 C.O. Electric# APPLICATION FOR BUILDING PERMIT Plumbing# 240 ORCHARD HILL DRIVE HVAC # Date: — 4- 9r Sprinkler# No.22621 FINAL APPROVALS Estimated Cost $ V Building COMPLETE RED BOXED AREAS Permit Fee 30 Engineering TYPE OR PRINT ONLY Occupancy Fee $ Affidavit SIGN ON REVERSE SIDE Appr.for CO. Total Fee 3 U TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR,CT Additional Cost) $ The and rsign d hereby applies to dowork according to the following specifications: Job Location E/t</® O 'e olfc/ IV,Lot No. Side of Street Zone Applicant t/u i 'fy1-r/a/t O Tel. # WS Address I oA 4e . rPt ' Zip B6/o? Lic. # 3 64 7o;2 3 Owner 17o- 1 'sl G2/'M4/t'o-,t/ Address o&eh.aa _ Architect Address Sq. Ft. New Ar a: 1st FI. 2nd FI. 3rd FI. Total New Area Rooms Lavatories Bathrooms Garages Purpose of this permit: P&^4 Dec tit tI Z ri City Water 1. Well 0 Septic System Sewer Use Group ±LA Construction Type N Area Basement Garage Approved by JOTDate cl '( Revised 6/95 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked, and agree that this budding is to be locate a oper distance from all street lines, side yard lines and required distances from all other zones and is located in a zone hic his buildin rid its u owed. Signed I hereby apply for a Certificate of Occupancy for the work described in his application for the permit Signed DO NOT WRITE BELOW THIS LINE -- INSPECTION COMMENTS Inspection / Approval Date By Appl Code Description Due Whom Code Comment 95-22621-B 2,500 BO1 FOOTING 09/19/95 JFF A B10 FINAL 05/13/96 JFH A