APPLICATION FOR BUILDING PERMIT
Plumbing
HVAC Date: J U L Y 17 , 1 990
Sprinkler 23 QUAIL RUN
El ctric Estimated Cost $ 1 _0 0 0
Zoning Permit Fee$ 1 . 050 . 00
18667AffidavitNO.Occupancy Fee $
1 13_._0 0
Eng. Dept.
Fire Dept. COMPLETE RED BOXED AREAS. Total Fee $ i 992 DO
H alth D ot. TYPE OR PRINT ONLY
Approved for CO: JAC. SIGN ON REVERSE SIDE. Additional Cost) $
TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT
The undersigned, hereby applies to do work according to the following specifications:
Job Location 23 QUAIL RUN SO .WINDSOR C R Lot No. 2 5 Side of Street . ZoneA-
Applicant DART HILL REALTY INC SO .WINDSOR CT 06Q74 Tel. 4 j-"'_
Address 658 ELLINGTON RD SO.WINDSOR CT Zip 06074 Lic.# 500356
STREET CITY STATE
Owner T 14 1 CONST,_CC) TUC Address 2AMF
Architect STR E 141C iAUD Address SAMF
Size New Area: Ft. Front Overall6 6 Ft. Deep Overall 112411 Total Area 1 . 980 #Garages 2
Lavatories
No. of Families 1 No. of Stories 2 Construction2 X 4 Bathrooms 2 Rooms 1st4-2nd 4 3rd
Size of Lot 30 On n Dist. from Street Line 11 5-5 It Dist. from Side Street Line 2-6 - 7
Purpose of this Permit CONSTRUCTION OF A SINGLE FAILY DWELLING
City Water ® Well Peptic Sewer
Approved by Date BD,A 11/88
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor
and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree
that this building is to be located the proper distance from all street lines,side yard lines and required distanc s from all oth r zon s and is
located in a zone in which this building and its use is allowed.
Signed
1 hereby apply for a Certificate of Occupancy for the work described in is application for permit.
Signed
DO NOT WRITE BEUDW THIS LINE—
INSPECTION RECORD
Footin Framing q—S7-2 0i -
rv_3_X P,
Foundation Fireplace/Chimney InsulationIV
POOPIumbing Perm' #
l->
Inspections:
HVAC Permit# , >_ — Inspections: /jg
iElectricalPermit#_ Inspections: d12,
Sprinkler Permit# Inspections:
i ri- all
BUILDING INSPECTION DEPARTMENT
SOUTH WI N DSOR, CON N ECTICUT
FEE PAID: $3.00
CERTIFICATE OF OCCUPANCY
ZONE: DATED 10/31 19 90
This is to certify that 23 Quail Run
Erected under permit No. 18 6 6 conforms substantially to the requirements of the building ordinances and the
zoning regulations of the Town of South Windsor and is hereby approved for occupancy as indicated below.
Approved for Occupancy— New single family dwelling -- Lot #25
Use Group: R4
Constr. Type: 5 B
Building Official
Notice:if this certificate is lost or destroyed, a duplicate should be obtained immed/ately from the Building Department.
Any change or extension of the use herein approved requires a new certificate of occupancy.
rd'i i ^C''}rh19i-,t`'f.' j-;',A'yQ<r'w•h,` .,u.4 .i.,
S^
t - f" •,
CERTIF ICATE OF OCCUPANCY CHECK LIST -7)CM-tc
A Dart Hill RealpplicantRealty Certificate Of Occu ancAddressp y / F'6 6, 7
Lot No. 25 (23 Quail Run Bldg. Permit No. &
Project Partridge Meadow
Date Submitted 10-24-90ReviewedBy
Date
Jt 7
As required in the Zoning Regulations, no certi ' cat -shall be issued until gradin plans
a of-occde cy G
g P s have been compapprovedbytheTownEngineer. The minimum requirementsinlcude:Q ements shall
Approved Denied N/A
1 1. Approved build ing permit plan.
2 . Finish grading per approvedpppovedbuildingpermitplan.
3 . Site work;trees, shrubs, dumpstersrequiredparkin
4 . Utility location
a. sanitary sewer
b. foundation drain
c. electrical & telephone
d. water
e. other
5 • Appropriate certification
6 . Bonding
Sewer Permit No.
Pavement Excay . No.
COMMENTS:
t 1!"'' 1y. •try W-."„ :1;ff'^..+na• rr a..1'!•'.-. ..-.- yw•.r+.nyS••vi••+'J.'1 i''s•k t'''' v w•-:.
f+ sbR p-- : i, "`v+!!,'Y•r.:• ;.;.fi r::;:i:s.• ti: c. ;. a- 't. r
VA
7='.n r CERTIFIr_VJ k, o ,r.*:,, LATE OF OCCUPANCY CHECK LIST
Applicant Dart Hill Realty Certificat of' OccupancyAddressBldg. Permit No.
Lot No. 1. 25 (23 Quail Run) Date Submitted 10-24-90ProjectPartridgeMeadowReviewedBY
i 2 J
Date
of
As required in the Zoning Regulations, no certificate-of-
grading
of occupancyshallbeissueduntil9gplanshavebeencompliedwithandapprovedbytheTownEngineer. The minimum requirements shallinlcude:
Approved Denied N/A
1. Approved buildingepermit plan.
2. Finish grading per approved
building permit plan.
3 . Site work; i.e. trees, shrubs, dumpsters
required parking
4 . Utility location
a. sanitary sewer
b. foundation drain
c. electrical & telephone
d. water
e. other
5 . Appropriate certifi cationication
6. Bonding
Sewer Permit No.
Pavement Excav . No.
COMMENTS:
BUILDING PERMIT CHECK LIST
Applicant art Lill Realty Z -- Building Permit No. Jg
Address 6SR Fll ;ngnt-n gong Date Submitted 7/17/90
Lot No. 29 23 Ouail Run Reviewed by 0AM
Project Pa rt r;a"P Meadow S13bd i uiS,0l?ate
In accordance with the Subdivision Regulations, prior to the building of
any structure on a lot, a Topographic Plot Plan shall be submitted for
approval. The minimum requirements shall include :
Approved Denied N/A
Y
1. Name, address & phone number of owner/
applicant.
2. Name, address & phone number of plan preparer.
3. Zoning information - i.e. zone, open space,
floodway, etc.
4 . Plot plan at 1" = 40 ' scale.
a. Subdivision reference, abutting
properties , etc.
b. Easements of record.
c. Lot description, bearings, distances,
building lines, area, etc.
e000, d. Contours, existing & proposed, 1 or 2 ft.
interval where appropriate.
e. Building location with dimensions.
Elevations of proposed finish floor,
garage floor & center line of road at
driveway.
0.010 f. Elevations of gravity drainage systems,
sanitary & foundation drain at the
house and the street.
g. Tentative utility location gas, electric ,
water, etc.
0000 h. Title block with name and address of
preparer, date appropriate certification,
live seal and signature.
5 . Sedimentation and erosion control.
6. Special Planning & Zoning, Inland/Wetlands
considerations. (Plans on file w/Town Clerk)
BUILDING DEPT.
PZC
IWA/CC
WPCA
OTHERS
COMMENTS: op
PERMIT #
DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT 115AI
Application is hereby:
TOWN OF SOUTH WINDSOR
jAPPROV
D DISAPPROVED BUILDING INSPECTION DEPT.
644-2511 Ext. 230
Vi
Application must be printed or typed.
Date Bu&Zfing Inspector
1 . LOCATION OF JOB
le o! o?.5
FEE SCHEDULE No . Street
0 - $19000 -10.00 Floor Apt . No.
Over $19000 - 10.00
per $1 ,000 or 2 . OWNER Z199T 1L-y /3zi9L-) `l
fraction thereof
3. ADDRE S S(0S<6 C/
C i1So(OHO7 y
4. APPLICANT -Uy E`er iA IL.
5 . ADDRESS
i
6. ESTIMATED COST $
7 . IS THIS A CONTRACT COST
Yes No
FEE ENCLOSED $ AaTwv &rn/'/
9. TYPE OF BUILDI
KESIDENTIAL COMMERCIAL
i
10. TYPE OF JOB :
e-riginal Installation
F Alteration/Addition/Repair
BD 3A 11/88
APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side)
11. LOCATION OF JOB /O/ o2 5— OUA-14
NO. STREET APT. NO
12 . TYPE OF INSTALLATION
13. SIZE OF MAIN FEEDER cc) f -, mil_
14. NO. OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS
16. NO. OF POWER LOOPS !7 17 . NO. OF LIGHT OUTLETS a S
18. NO. OF HEAT CIRCUITS 19. NO. OF POWER OUTLETS
20. NO. OF CONVENIENCE OUTLETS L1 3 21. NO. OF HEAT CIRCUITS /
22 . NO, OF POWER CIRCUITS a 23. NO. OF LIGHT CIRCUITS Cv
24. SIZE OF HEAT CIRCUITS /5/4MP 25 . NO. OF MOTORS
26. NO. OF PANELS 27 . TOTAL WATTAG E \ 1<W
28 . NO. OF POWER FEEDERS 29. NO. OF SWITCHES
30. A/C LOAD 31. SIZE OF POWER FEEDERS 1 td/9-L-
32. NO. OF FIXTURES 5 33. TOTAL HORSEPOWER
34 . NAME OF SUBCONTRACTORS AND TIEIR TRADES
35 . REMARKS AND FURTHER DETAILS :
LICENSE NO.SIGNATURE OF APPLICANT DATE
PHONE NUMBER: 37d- lS9D
77
I c!,
Wild$lg PermitT_
Temporary Service
Permanent Service
Pursuant to Permit No.
This Certifies that the Electrical Work for which the above named Permit was grantedhasbeendulyinspectedandisherebyapproved.
Owner C- D Electrician
Street
19Q
Buildi g Insp or
i
PERMIT NO.
DEPARTMENT DECISION APPLICATION F O R
Application is hereby: PLUMBING PERMIT
TOWM OF SOUTH WIND SOR
APPROVED DISAPPROVED BUILDING INSPECTION DEPT.
2$
644-2511 Ext. 230
Date B ding Inspector Application must be printed or typed.
1. LOCATION OF JOB:
letzel Z-6
FEE SCHEDULE 2. OWNER:^)q.¢,ej h ct.
3. ADDRESS:
0 - $19000 -10.00
Over $1 ,000 - 10.00
per $1 ,0 0 0 or 4. APPLICANT: p C
fraction thereof
5. ADDRESS: 36 A,1 a y T
6. EST. COST: $ V00,00
7. IS THIS A CONTRACT COST? YES NO
8. FEE ENCLOSED: $
9. TYPE OF BUILD NG:
RESIDENTIAL COMMERCIAL
10. TYPE OF JOB:
ORIGINAL ALTERATION
INSTALLATION ADDITION
REPAIR
BD 2A 11/88
APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side)
11. LOCATION OF JOB: ii- )vh - Ax?/P,/ ' £ /%t¢le Ze-)
GENERAL PLUMBING
12. KIND OF INSTALLATION: lt/&cry c 7/ A,2:2S/_ 13. SIZE OF MAIN DRAIN
14. NO. OF TOILETS 3 STYLE 15. NO. OF URINALS - STYLE
16. NO. OF BATHTUBS 16A. NO. OF SHOWERS 17. NO. OF LAVATORIES 3
18. NO. OF SINKS / _ 19. DISPOSAL_19A. DISWASHER /
20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS SIZE
22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS
25. NO. OF OTHER FIXTURES KIND
26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW?S
27. SIZE OF WINDOW
28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE?
29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK?
31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS
32. REMARKS AND FURTHER DETAILS lv jr p " S`
7Z L
WATER HEATER
33. TYPE 34. MANUFACTURER i 62-
TANKS SAFETY DEVICES
T EMP ERATURE
35. CAPACITY 1f(Zp -ol.39. RELIEF VALVE
36. TEST PRESSURE LBS. 40. MANUFACTURER
T
37. WORKING PRESSURE g7olp.S LBS. 41. PRESSURE RELIEF VALVE
38. TYPE 42. MANUFACTURER jt f 7TS
LICENSE NU. DATE IGN TURF OF APPLICANT
PHONE NO. 142 ; 7
L
FOR O"ICE .os Y APPL 'AT om mvAC PERMIT BATE:
w...ram..
Np, R TOWN OF SOUTH WUMOR EST.COST:
BLDG. PERMIT 0. 1540 SULLIVAN AVENUE FEE
SO vMa, CTF p7 i FEES
b 2 11 " t. 3#1 0 '- $19 000 '" $10.00
1000 or fraction
LOCATION OF BUIL q+O
thereof - $10.00
00
OWNER ADDRE TOWN PHONE N0*
a y
HV -,£CQNTRA£TOR ADDRESS TOWN PROW NO.
TYPE OF SYSTEM: HEATING
r
TYPE OF BUILDING: RESIDENTIAL
A/C CONKERCIAL
VENTILATION BUSINESS
INDUSTRIAL
F HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
HYDRONIC_tooe- WARM AIR
UNIT RADIANT HEATER (INCLUDING WOOD COAL BURNING STOVE)
TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW
WOOD COAL
OIL TANK - SIZE & LOCATION.: INSIDE OUTSIDE CAPACITY_
LPG TANK - CAPACITY
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS (BTUH) HEAT LOSS SHEET MUST ACCOMPANY PLICA I N),
DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.):
C
GROSS HgATING CAPACITY (INPUT-BTUH) Q NET RATING (OUTPUT-BTUH)iz
IF AIR CONDITIONING: DESIGN TEMP. OUTS E OF INSIDE OF DIFFERENCE F
TOTAL HEAT GAIN (BTUH)
HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.):
TONNAGE COOLING CAPACITY (BTUH)
IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT):
TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM)
PLAN MUST ACCOMPANY APPLICATION)
The undersigned hereby applies for a permit to perform the following work and is to comply
with all local ordinances and State of Conn. Building Codes in the performance of such work.
FURTHER DESCRIPTION OF WORK: zM110v4.,L11 5 O
ka//v 0, J
000
7
STATE LICENSE - NAME & TYPE #DATE GNATURE APP ICAN
z/v qtz
APPROVED DATE
BD 4A 11/88
I - B a R CALCULATION SHEET IN3 (Modern Method) Copyright 1977 by Th Hydronics Institute
WHEN ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE
COL.A COL.S COL.C COL.D COL.E COL.F COL.G
1 ROOM
Design Water Temp.O H L W M L W H L W H L W H L W
2 ROOM DIMENSIONS,FT.U STUN per F t of
3 LENGTH EXPOSED WALLS,FT. Radiation Selected
4 WINDOW AND OUTSIDE DOOR AREA a
BTUH BTUH STUN BTUH STUN
5 WALL CONSTRUCTION ROOM LIN.FT.OF
Table 9,Line 3 x H) TOTALS RADIATION
6 TYPE OF GLASS FROM LINE I SELECTED
B ttom of table used for Line 5)
7 CEILING CONSTRUCTION C
Table 9.L x W)D
g FLOOR CONSTRUCTIONt
Table 9. L x W or Lin. Ft) E
9 COLD PARTITION CONSTRUCTION F
Tsbie 9,L x HI G
10 _c 1 Wall(With Openings)C
2 Wells(With Openings) X:
3 Wells(With Openings) or Ent.Hall f.
1
11 TOTAL BTUH AT 70F TEMP. DIFFERENCE'
12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE K
COL.A COLS COL.H COL. 1 COL.J COL.K COL.L TOTAL BTUH TOTAL
1 ROOM OF BUILDING RADIATION
AT SELECTED
O H L W q L W N L W H L W H L W DESIGN TEMP.'
2 ROOM DIMENSIONS. FT 1 DIFFERENCE
u
3 LENGTH EXPOSED WALLS, FT. 4
4 WINDOW AND OUTSIDE DOOR AREA U.
BTUH BTUH BTUH STUN BTUH
5 WALL CONSTRUCTION INCREASE BATHROOM
Table 9.Line 3 x H) TOTAL 20%
6 TYPE OF GLASS
Bottom of table used for Line 5)
tFOR CONCRETE FLOOR ON
7 CEILING CONSTRUCTION GROUND OR FILL AT
Table 9,L x W)GRADE:LEVEL,USE LINEAR
FEET OF EXPOSED EDGEBFLOORCONSTRUCTION(
Table 9,L x W or Lin. Ft.)
9 COLD PARTITION CONSTRUCTION
Table 9, L x H)
10 -C 1 Wall(With Openings) G
2 Walls(With Openings) XeJ
3 Walls(With Openings) r Ent. Hall 1.
I I TOTAL BTUH AT 7OF TEMP. DIFFERENCE'
12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE
FORM 1503
This form Is available fr m The Hydronlcs Institute.35 Russo Place,Berkoley Heights,N.J. 07922
Page 1
HEATLOSS vers 3. 1 Copyright 19 I'll6, 1987, Thomas and Associates, Bellaire, Mi
616) 533-8472
PETER SAVAS
56 CHRISTOPHER DR
WESTFIELD, MA 01085
413) 562-6986
08-30-1990
D & G PLUMBING
LOT 25
PARTHRIDGE MEADOW
ENTRY Prepared by PETER SAVAS
HEATLOSS
THE TbTAL BTUH FOR THIS ROOM IS 3, 630
The total feet of radiation required for this room 7. 3
DINING ROOM Prepared by PETER SAVAS
HEATLOSS
THE TOTAL BTUH FOR THIS ROOM IS 5, 217
The total feet of radiation required for this room 10. 4
REAR ENTRY Prepared by PETER SAVAS
HEATLOSS
THE TOTAL BTUH FOR THIS ROOM IS 1 , 570
The total feet of radiation required for thzs room 3. 1
BATH Prepared by PETER SAVAS
HE AT*LOSS
THE TOTAL BTUH FOR THIS ROOM IS 1 , 577
The total feet of radiation required for this room 3. 2
KITCHEN Prepared by PETER SAVAS
HEATLOSS
THE TOTAL BTUH FOR THIS ROOM IS 4, 490
The total feet of radiation required for this room 9. 0
FAMILY ROOM Prepared by PETER SAVAS
HEATLOSS
THE TOTAL BTUH FOR THIS ROOM IS 6, 438
The total feet of radiation required for this room 12. 9
LIVING ROOM Prepared by PETER SAVAS
HEATLOSS
THE TOTAL BTUH FOR THIS ROOM IS 4, 936
The total feet of radiation required for this room 9. 9
RIGHT FRONT BEDROOM Prepared by PETER SAVAS
HEATLOSS
THE TOTAL BTUH FOR THIS ROOM IS 6, 419
Page 2
The total feet of radiation required for this room 12. 8
MASTER BEDROOM CLOSET Prepared by PETER SAVAS
HEATLOSS
TA TOTAL DTUH FOR THIS ROOM Ig 1 , 038
The total feet of radiation required for this room 2. 1
HALL BEDROOM Prepared by PETER SAVA':_
HEATLOSS
THE TOTAL BTUH FOR THIS ROOM IS 440
The total feet of radiation required for this room 0. 9
MASTER BATH Prepared by PETER SAVAS
HEATLOSS
THE TOTAL BTUH FOR THIS ROOM IS 1 , 985
The total feet of radiation required for this room 4. 0
MAIM BATH Prepared by PETER SAVAS
HEATLOSS
THE TOTAL BTUH FOR THIS ROOM IS 1 , 717
The total feet of radiation required for this room 3. 4
BEDROOM Prepared by PETER SAVAS
HEATLOSS
THE TOTAL BTUH FOR THIS ROOM IS 5, 006
The total feet of radiation required for this room 10. 0
BEDROOM FRONT CORNER Prepared by PETER SA VAS
HEATLOSS
THE TOTAL BTUH FOR THIS ROOM IS 6, 161
The total feet of radiation required for this room 12. 3
BEDROOM Prepared by PETER SAVAS
HEATLOSS
THE TOTAL BTUH FOR THIS ROOM IS 2, 503
The total feet of radiation required for this room 5. 0
TOTALS FOR LIVING AREA
THE TOTAL BTUH FOR THIS AREA IS
The total feet of radiation required for this
End of report
Page 1
HEATLOSS vers 3. 1 Copyright 1986, 1987, Thomas and Associates, Bellaire, Mi
616) 533-8472
PETER SAVAS
56 CHRISTOPHER DR
WESTFIELD, MA 01085
413) 562-6986
08-30-1990
D & G PLUMBIN8
LOT 25
PARTHRIDGE MEADOW
ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA
ENTRY Prepared by PETER SAVAS
ROOM NUMBER 1 CEILING HEIGHT IS 8. 00 VOLUME IS 960. 00 CUBIC FEET
1 EXPOSED OPENINGS, TOTALING >>>>>>>>>>>>>>>>>>>>>>>> 38. 08 SQUARE FEET
1 EXPOSED WALLS, not including openings, TOTALING >>> 4 1 . 92 SQUARE FEET
ROOM SIZE IS 10. 00 LONG by 12. 00 WIDE, TOTALING >> 120. 00 SQUARE FEET
FLOOR TYPE IS: Floor over any Conditioned Space
CEILING TYPE IS: Conditioned space above
WINDOW TYPE IS: No openings in thjs room
WALL CONSTRUCTION IS: Frame, Insulated
HEATLOSS
The Total BTUH for the outside walls are 277
The Total BTUH for the Exposed Openings are 17072
The total BTUH for the ceilings 0
The total BTUH for the floors 0
The BTUH infiltration for the walls is 0
The BTUH infiltration for the openings zs 2, 281
THE TOTAL BTUH FOR THIS ROOM IS 3, 630
The total feet of radiation required for this room 7. 3
EST TIMAED HEAT LOSS C L.ALCUATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA
DINING ROOM Prepared by PETER SAVAS'
ROOM NUMBER 2 CEILING HEIGHT IS 8. 00 VOLUME IS 1248. 00 CUBIC FEET
3 EXPOSED OPENIN IIIS, TOTALINIli 00 SQUARE FEET
2 EXPOSED WALLS, not including openings, TOTALIN6 >>> 155. 00 SQUARE FEET
ROOM SIZE IS 13. 00 LONG by 12. 00 WIDE, TOTALING 156. 00 SQUARE FEET
FLOOR TYPE IS: Floor over any Conditioned Space
CEILING TYPE IS'". Conditioned space above
WINDOW TYPE IS: Single with storm sash
WALL CONSTRUCTION IS: Frame, Insulated
HEATLOSS
The Tota] BTUH for the outside walls are 1 , 023
The Total BTUH for the Exposed Openings are 2, 218
The total BTUH for the ceilzngs 0
The total BTUH for the floors 0
The BTUH infiltration for the walls is 0
The BTUH infiltration for the openings is 1 , 977
THE TOTAL BTUH FOR THIS ROOM IS 5, 217
The total feet of radiation required for thjs room 10. 4
ESTIMATED HEAT LOSSLCULATIONCA FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA
Page 2
REAR ENTRY Prepared by PETER SAVAS
ROOM NUMBER 3 CEILING HEIGHT IS 8. 00 VOLUME IS 320. 00 CUBIC FEET
2 EXPOSED OPENINGS, TOTALING >>>>>>>>>>>>>>>>>>>>>>>> 20. 40 SQUARE FEET
2 EXPOSED WALLS, not including openings, TOTALING >>> 35. 60 SQUARE FEET
ROOM SIZE IS 10. 00 LONG by 4. 00 WIDE, TOTALING >>40. 00 SQUARE FEET
FLOOR TYPE IS: Floor over any Conditioned Space
CEILING TYPE IS: Conditioned space above
WINDOW TYPE IS: No o m
WALL CONSTRUCTION IS: Frame, Insulated
HEATLOSS
The Total BTUH for the outside walls are 235
The Total BTUH for the Exposed Openings are 574
The total BTUH for the ceilings 0
The total BTUH for the floors 0
The BTUH infiltration for the walls is 0
The BTUH infiltration for the openings is 760
THE TOTAL BTUH FOR THIS ROOM IS 1 , 570
The total feet of radiation required for this room 3. 1
ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA
BATH Prepared by PETER SAVAS
ROOM NUMBER 4 CEILING HEIGHT IS 8. 00 VO MELU IS 320. 00 CUBIC FEET
1 EXPOSED OPENINGS, TOTALING >>>>) >>>>>>>>>>>>>>>>>>>9. 00 SQUARE FEET
2 EO SE D WALL S, not inclu d J. openings, TOTALING >>> 95. 00 SQUARE FEETXP
ROOM SIZE IS 8. 00 LONG by 5. 00 WIDE, TOTALING >>40. 00 SQUARE FEET
FLOOR TYPE IS: Floor over any Conditioned Space
CEILING TYPE IS: Conditioned space above
WINDOW TYPE IS: Single with storm sash
WALL CONSTRUCTION IS: Frame, Insulated
HEATLOSS
The Total BTUH for the outside walls are 627
The Total BTUH for the Exposed Openings are 444
The total BTUH for the ceilings 0
The total BTUH for the floors 0
The BTUH infiltration for the walls is 0
The BTUH infiltration for the openings is 507
THE TOTAL BTUH FOR THIS ROOM IS 1 , 577
The total feet of radiatzon required for this room 3. 2
ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUJLDING (C) 1986, 1987 TA
KITCHEN Prepared by PETER SAVA S
ROOM NUMBER 5 CEILING HEIGHT IS 8. 00 VOLUME JS 1728. 00 CUBIC FEET
2 EXPOSED OPENINGS, TOTALlNG >>>>>>>>>>>>>>>>>>>>>>>> 52. 80 SQUARE FEET
1 EXPOSED WALLS, not including openings, TOTALING >>> 91 . 20 SQUARE FEET
ROOM SIZE IS 18. 00 L ON G by 12. 00 WIDE, TOTALING >> 216. 00 SQUARE FEET
FLOOR TYPE IS: Floor over any Conditioned Space
CEILING TYPE IS: Conditioned space above
WINDOW TYPE IS: Single with storm sash
WALL CONSTRUCTION IS: Frame, Insulated
HEATLOSS
The Total BTUH for the outside walls are 602
The Total BTUH for the Exposed Openings are 2, 063
The total BTUH for the ceilings 0
The total BTUH for the floors 0
Page 3
The BTUH infiltration for the walls is 0
The BTUH infiltration for the openings is 1 , 825
THE TOTAL BTUH FOR THIS ROOM IS 4, 490
The total feet of radiation required for this room 9. 0
ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA
FAMILY ROOM Prepared by PETER SAVAS
ROOM NUMBER 6 CEILING HEIGHT IS 8. 00 VOLUME IS 1920. 00 CUBIC FEET
1 EXPOSED OPENINGS, TOTALING 40. 00 SQUARE FEET
2 EXPOSED WALLS, not including openings, TOTALING >>> 216. 00 SQUARE FEET
ROOM SIZE IS 20. 00 LONG by 12. 00 WIDE, TOTALING >> 240. 00 SQUARE FEET
FLOOR TYPE IS: Floor over any Conditjoned Space
CEILING TYPE IS: Conditioned space above
WINDOW TYPE IS: Single with storm sash
WALL CONSTRUCTION IS: Frame, Insu la.ted
HEATLOSS
The Tota] BTUH for the outsjde walls are 1 , 426
The Total BTUH for the Exposed Openings are 1 , 971
The total BTUH for the ceilings 0
The total BTUH for the floors 0
The BTUH infiltration for the walls is 0
The BTUH infiltration for the openings is 3, 041
THE TOTAL BTUH FOR THIS ROOM IS 6, 438
The total feet of radiation required for this room 12. 9
ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIA|. BUILDING (C) 1986, 1987 TA
LIVING ROOM Prepared by PETER SAVAS
ROOM NUMBER 7 CEILING HEIGHT IS 8. 00 VOLUME IS 1408. 00 CUBIC FEET
2 EXPOSED OPENIN6S, TOTALIN6 >>>>>>>>>>>>>>>>>>>>>>>> 30. 00 SQUARE FEET
2 EXPOSED WALLS, not including openings, TOTALING >>> 186. 00 SQUARE FEET
ROOM SIZE IS 11 . 00 LONG by 16. 00 WIDE, TOTALING >> 176. 00 SQUARE FEET
FLOOR TYPE IS: Floor over any Conditioned Space
CEILlNG TYPE IS: Conditioned space above
WINDOW TYPE IS: Single with storm sash
WALL CONSTRUCTION IS: Frame, Insulated
HEATLOSS
The Total BTUH for the outside walls are 1 , 228
The Total BTUH for the Exposed Openzngs are 1 , 478
The total BTUH for the ceilings 0
The total BTUH for the floors 0
The BTUH infiltration for the walls is 0
The BTUH infiltration for the openings is 2, 230
THE TOTAL BTUH FOR THIS ROOM IS 4, 936
The total feet of radiation required for this room 9. 9
ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA
RIGHT FRONT BEDROOM Prepared by PETER SAVAS
ROOM NUMBER 8 CEILING HEIG HT IS 8. 00 VOLUME IS 1440. 00 CUBIC FEET
3 EXPOSED OPEN INGS, TOTALIN6 45. 00 SQUARE FEET
2 EXPOSED WALLS, not including openings, TOTALING >>> 171 . 00 SQUARE FEET
ROOM SIZE IS 12. 00 LONG by 15. 00 WIDE, TOTALING >> 180. 00 SQUARE FEET
FLOOR TYPE IS: Floor over any Conditioned Space
Page 4
CEILING TYPE IS: Unronditioned Attic Space Above
WINDOW TYPE IS: Single with storm sash
WALL CONSTRUCTION IS: Frame, Insulated
HEATLOSS
The Total BTUH for the outside walls are 1 , 129
The Total BTUH for the Exposed Openings are 2, 218
The total BTUH for the ceilings 792
The total BTUH for the floors 0
The BTUH infiltration for the walls is Cl
The BTUH infiltration for the openings is 2, 281
THE TOTAL BTUH FOR THIS ROOM IS 6, 419
The total feet of radiation required for this room 12. 8
ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA
MASTER BEDROOM CLOSET Prepared by PETER SAVAS
ROOM NUMBER 9 CEILING HEIGHT IS 8. 00 VOLUME IS 448. 00 CUBIC FEET
0 EXPOSED OPENINGS, TOTALING >>>>>>>>>>>>>>>>>>>>>>0. 00 SQUARE FEET
2 EXPOSED WALLS, not including openings, TOTALING >>> 120. 00 SQUARE FEET
ROOM SIZE IS 7. 00 LONG by 8. 00 WIDE, TOTALIN6 >>56. 00 SQUARE FEET
FLOOR TYPE IS: Floor over any Conditioned Space
CEILING TYPE IS: Unconditioned Attic Space Above
WINDOW TYPE IS: No openings in this room
WALL CONSTRUCTION lS: Frame, Insulated
HEATLOSS
The Total BTUH for the outside walls are 792
The Total BTUH for the Exposed Openings are 0
The total BTUH for the ceilings 246
The total BTUH for the floors 0
The BTUH infiltration for the walls is 0
The BTUH infiltration for the openings is 0
THE TOTAL BTUH FOR THIS ROOM IS 1 , 038
The total feet of radiation required for this room 2. 1
ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA
HALL BEDROOM Prepared by PETER SAVAS
ROOM NUMBER 10 CEILIN8 HEI8HT IS 8. 00 VOLUME IS 320. 00 CUBIC FEET
0 EXPOSED OPENINGS, TOTALING >>>>>>>>>>>>>>>>>>>>>>>>0. 00 SQUARE FEET
1 EXPOSED WALLS, not including openings, TOTALING >>> 40. 00 SQUARE FEET
ROOM SIZE IS 5. 00 LONG by 8. 00 WIDE, TOTALING >>40. 00 SQUARE FEET
FLOOR TYPE IS: Floor over any Conditioned Space
CEILING TYPE IS: Unconditioned Attic Space Above
WINDOW TYPE IS: No openings in this room
WALL CONSTRUCTION IS: Frame, Insulated
HEATLOSS
The Total BTUH for the outside walls are 264
The Total BTUH for the Exposed Openings are 0
The total BTUH for the ceilings 176
The total BTUH for the floors 0
The BTUH infiltration for the walls is 0
The BTUH infiltration for the openings is 0
THE TOTAL BTUH FOR THIS ROOM IS 440
The total feet of radiation required for this room 0. 9
Page 5
ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA
MASTER BATH Prepared by PETER SAVAS
ROOM NUMBER 11 CEILING HEIGHT IS 8. 00 VOLUME IS 448. 00 CUBIC FEET
1 EXPOSED OPENINGS, TOTALING 12. 00 SQUARE FEET
1 EXPOSED WALL8, not including openings, TOTALING SQUARE FEET
ROOM SIZE IS 7. 00 LON G by 8. 00 WIDE, TOTALING >>56. 00 SQUARE FEET
FLOOR TYPE IS: Floor over any Conditioned Space
CEILING TYPE IS: Unconditioned Attic Space Above
WINDOW TYPE IS: Single with storm sash
WALL CONSTRUCTION IS: Frame, Insulated
HEATLOSS
The Total BTUH for the outside walls are 343
The Total BTUH for the Exposed Openings are 591
The total BTUH for the ceilings 246
The total BTUH for the floors 0
The BTUH infiltration for the walls is 0
The BTUH infiltration for the openings is 473
THE TOTAL BTUH FOR THIS ROOM IS 1 , 985
The total feet of radiation required for this room 4. 0
ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA
MAIM BATH Prepared by PETER SAVAS
ROOM NUMBER 12 CEILING HEIGHT IS 8. 00 VOLUME IS 448. 00 CUBIC FEET
1 L GEXPOSEDOPENINGS, TOTAIN >>>>>>>>>> >>>>>>>>>>>>8. 00 SQUARE FEET
1 EXPOSED WALLS, not zncluding openings, TOTALING >>> 48. 00 SQUARE FEET
ROOM SIZE IS 7. 00 LONG by 8. 00 WIDE, TOTALING >>56. 00 SQUARE FEET
FLOOR TYPE IS: Floor over any Conditioned Space
CEILING TYPE IS: Unconditioned Attic Space Above
WINDOW TYPE IS: Single with storm sash
WALL CONSTRUCTION IS: Frame, Insulated
HEATLOSS
The Total BTUH for the outside walls are 317
The Total BTUH for the Exposed Openings are 394
The total BTUH for the ceilings 246
The total BTUH for the floors 0
The BTUH infiltration for the walls is 0
The BTUH infiltration for the openings is 473
THE TOTAL BTUH FOR THIS ROOM IS 1 , 717
The total feet of radiation required for this room 3. 4
ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL BUILDING (C) 1986, 1987 TA
BEDROOM Prepared by PETER SAVAS
ROOM NUMBER 13 CEILING HEIGHT IS 8. 00 VOLUME IS 1152. 00 CUBIC FEET
2 EXPOSED OPENINGS, TOTALING >>>>>>>>>>>) >>>>>>>>>>> 30. 00 SQUARE FEET
2 EXPOSED WALLS, not including openings, TOTALING >>> 162. 00 SQUARE FEET
ROOM SIZE IS 12. 00 L ON G by 12. 00 WIDE, TOTALING >> 144. 00 SQUARE FEET
FLOOR TYPE IS: Floor over any Conditioned Space
CEILING TYPE IS: Unconditioned Attic Space Above
WINDOW TYPE IS: Single with storm sash
WALL CONSTRUCTION IS: Frame, Insulated
HEATLOSS
The Total BTUH for the outside walls are 1 , 069
The Total BTUH for the Exposed Openings are 1 , 478
Page 6
The total BTUH for `the ceilings 634
The total BTUH for the floors 0
The BTU* infiltration for the walls is 0
The BTUH infiltration for the openings is 1 , 825
THE TOTAL BTUH FOR THIS ROOM IS 5, 006
The t,otal feet of ,adiation required for this room 1.0. 0
ESTIMATED HE T LOSS CALCULATION FOR RESIDENTIAL BUILDING /C) 1986, 1987 TA
BEDROOM FRONT CORNER Prepared by PETER SAVAS
ROOM NUMBER 14 CEILING HEIGHT IS 8. 00 VOLUME IS 1344. 00 CUBIC FEET
3 EXPOSED OPENING IS', TOTALING >>>>>>>>>>>>>>>>>>>>>>>> 45. 00 SQUARE FEET
2 EXPOSED WALLS, not including openings, TOTALING ) >> 163. 00 SQUARE FEET
ROOM SIZE IS 12. 00 LONG by 14. 00 WIDE, TOTALING >> 168. 00 SQUARE FEET
FLOOR TYPE IS: Floor over any Conditioned Space
CEILING TYPE IS: Unconditioned Attic Space Above
WINDOW TYPE IS: Single with storm sash
WALL CONSTRUCTION IS: Frame, Insulated
HEATLOSS
The Total BTUH for the outside walls are 1 , 076
The Total BTUH for the Exposed Openings are 2, 218
The total BTUH for the ceilings 739
The total BTUH for the floors 0
The BTUH infiltration for the walls is 0
The BTUH infiltration for the openings is 2, 129
THE TOTAL BTUH FOR THIS ROOM IS 6, 161
The total feet of radiation required for this room 12. 3
ESTIMATED HEAT LOSS CALCULATION FOR RESIDENTIAL L GBUIDIN (C) 1986, 1987 TA
BEDROOM Prepared by PETER SAVAS
ROOM NUMBER 15 CEILING HEIGHT IS 8. 00 VOLUME IS 864. 00 CUBIC FEET
1 EXPOSED OPENINGS, TOTALING >>>>>>>>>>>>>>>>>>>>>>>> 15. 00 SQUARE FEET
1 EXPOSED WALS no cu o nL , t inlding pein L.gs, TOTAING >>> 57. 00 SQUARE FEET
ROOM SIZE IS 9. 00 LONG by 12. 00 WIDE, TOTALING >> 108. 00 SQUARE FEET
FLOOR TYPE IS: Floor over any Conditioned Space
CEILING TYPE IS: Unconditioned Attic Space Above
WINDOW TYPE IS: Single with storm sash
WALL CONSTRUCTION IS: Frame, Insulated
HEATLOSS
The Total BTUH for the outside walls are 376
The Total BTUH for the Exposed Openings are 739
The total BTUH for the ceilings 475
The total BTUH for the floors 0
The BTUH infiltration for the walls is 0
The BTUH infiltration for the openings is 912
THE TOTAL BTUH FOR THIS ROOM IS 2, 503
The total feet of radiation required for this room 5. 0
TOTALS FOR LIVING AREA
VOLUME IS 14368 CUBIC FEET
EXPOSED OPENlNGS, TOTALING >>>>>>>>) >>>>>>>>>>>>>>>>>> 390 SQUARE FEET
EXPOSED WALLS, not including openings, TOTALING ) >>>>> 1634 SQUARE FEET
TOTAL SQUARE FOOTAGE OF HOME 1796 SQUARE FEET
Page 7
Prepared by P TER -SAVAS
HEATLOSS
The Total BTUH for the Exposed Openings are 17, 459
The total BTUH for the ceilings 3, 555
The total B T U H for the floors 0
The BTUH infiltration for the walls is 0
The BTUH infiltration for the openings is 20, 714
THE TOTAL BTUH FOR THIS AREA IS 53, 129
The total feet of radiation required for this area 106. 3
End of report