Loading...
HomeMy WebLinkAbout23 Calla Lily LaneFBuildng " CTIQ S. g 2 APPLICATION FOR BUILDING PERMIT Plumbing to ' 2- HVAC 1' " 2 Date: 3 31 92 Sprinkler 23 CALLA LILY LANE Electric 1 `9 2 Estimated Cost $ 63,JOOO.00 Zoning Permit Fee;630.00 Affidavit NO. 19811 Occupancy Fee $ 3.00 Eng. Dept. Z ROVE Fire Dept.COMPLETE RED BOXED AREAS.Total Fee $633.00 Health Dept. TYPE OR PRINT ONLY SIGN ON REVERSE SIDE.Approved for CO: 7 Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Location 23 Calla Lily Lane Lot No._23—Side of Street RZone 11B7_ Applicant Brom Builders, Inc. Tel. # 889-7106 Address 207 West Town St. , Norwich, Ct. Zip 06360 Lic.# 5000339 STREET CITY STATE Owner Brom Builders, Inc. Address Same Architect A.W. Mastronunzio Address 36 Pleasant View, Jewett City, Ct. 06351 Sire New Area: Ft. Front Overall 26' Ft. Deep Overall 37' Total Area Garages 1 Size of Lot 5,999 sf Dist. from Street Line 25' Lavatories_ Bathrooms Rooms 1st 3 2nd 3 3rd Purpose of this Permit Construct a 3 bedroom single fardly dwelling City Water 0 Well 0 Septic 0 Sewer Use Group Construction Type Approved by Jam— Date BD1A 11/88 I h reby agr a to conform to all the requirements of the Laws of the State of Connecticut and the Ordinanc s of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone in which this building and its use is allowed. Signed 2AZ I hereby apply for a Certificate of Occupancy for the work described in this application for permit. Signed DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footin `1` Framing 92 oe- Foundation y15 Fir place + mney Insulation '91V 2v pit N Plumbing Permit# q C)C;1 Inspections: •S"1)` 92 HVAC Permit# y 3 5 Inspections: 6--/t Electrical Permit# t, Inspections: S- 7 9' MW 30--rv"L.e Sprinkler Permit# Inspections: Location of job 7 AFFIDAVIT Additional Fee .. ... ......... State of Connecticut i County of Hartford ss. Owner I. ... Odl Y``?.............of . .O1".!'v ( .'t4 Agent for building erected underContractor Permit No. .....g8.(.............. issued by the Dep't of Building of the 7bwn of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized under said permit was. ...?.° 4"L eS i. Coos- d "');?ov — Signed .............. c.... . Subscribed and sworn to before me this ............(...........day of .. ......... may,........... A.D.19(. ;2-. 7 on Esfmate Cost:$ Z& flrzJ Difference: $ Notary Public Inspection / Approval Date By Appl Code Description Due Whom Code Comment 92-19811-B 63,000. BO1 FOOTING 04/09/92 002 A B02 FOUNDATION 04/09/92 002 A B02 FOUNDATION 04/14/92 001 A B02 FOUNDATION 04/15/92 001 D FOOTING DRAINS NOT READY B02 FOUNDATION 04/20/92 002 A FOOTING DRAINS OK E01 SERVICE 05/07/92 003 A RELEASE ISSUED OK B03 FRAMING (ROUGH)05/11/92 003 A P03 ROUGH 05/11/92 003 A H03 ROUGH 05/11/92 003 A E03 ROUGH 05/11/92 003 D B04 INSULATION 05/12/92 003 D NOT READY B04 INSULATION 05/13/92 003 A REINSPECTION OK B10 FINAL 06/17/92 003 A APPROVED FOR CO/CLOSEOUT 92-12168-E 2,600 92-8435-H 3,000 92-9023-P 3,500 Total Est Value 72,100 w CERTIFICATE OF OCCUPANCY CHECK LIST Applicant Brom Builders Certificate of Occupancy 60 Address Bldg. Permit No. Lot No. 23 calla Lily Lane Date Reviewed Project PEACHBROOKE Reviewed By Date Submitted 6-9-92 Approved/D d _C!" 7-7,6-77 As required in the Zoning Regulations, no Certificate-of-Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1 . Approved building permit plan. 2 . Finish grading per approved building permit plan. 3. Site work; i.e. trees, shrubs, dumpsters, required parking. 4 . Utility location a. Sanitary sewer b. foundation drain c. electrical & telephone d. water e. other 5. Sewer connection charge paid. 6 . Appropriate certification 7 . Bonding L 8. Planning & Zoning Sewer Permit No. Pavement Excavation No. COMMENTS: BUILDING PERMIT CHECK LIST fApplicantBromBuildersInc . Building P rinit No. Address207West Toen St. , Norwic Ct.Date Submitt d 4 01 Lot No. 23 #23 Calla Lily Lane _ Reviewed by Proj ect Peachbrook Date glilq In accordance with the Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include: Approved Denied N/A 1. Name, address & phone number of owner/ applicant. 2. Name, address & phone number of plan preparer. 3. Zoning information - i.e. zone, open space, floodway, etc. ZO 4. Plot plan at 1" = 44' scale. a. Subdivision reference, abutting properties, etc. b. Easements of record. c. Lot description, bearings, distances, building lines, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate. e. Building location with dimensions. Elevations of proposed finish floor, garage floor & center line of road at driveway. f. Elevations of gravity drainage systems, sanitary & foundation drain at the house and the street. V0 A g. Tentative utility location a , ectri , water, etc. h. Title block with name and address of preparer, date appropriate certification, live seal and signature.UA 5. Sedimentation and erosion control. kA 6. Special Planning & Zoning, Inland/Wetlands considerations. (Plans on file w/Town Clerk) BUILDING DEPT. PZC IWA/CC WPCA OTHERS COMMENTS: t PERMIT t a DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby :TOWN OF SOUTH WINDSOR APPROVED ISAPPR BUILDING INSPECTION DEPT. 644-2511 Ext . 230 Application must be printed or typed . Date Building Inspector 1 . LOCATION OF JOB 6L 00)/0 kil)a FEE SCHEDULE No . St et 0 - $19000 - 10.00 Floor Apt . No . Over $1,000 -10.00 EQper $1 ,000 or 2 . OWNER oleA!75,,Imc, fraction thereof C)n Wte,4,ruoo3 . ADDRESS 4. APPLICANT e c (,c v)c. 5 . ADDRESSQO RaP,M 6 . ESTIMATED COST $ t2,(P 40-- 7 . IS THIS A CONTRACT COST Ye s .A10 tJ 8 . FEE ENCLOSED $L3 " 9 . TYPE OF BUILDING:_ LZRESIDENTIAL COMMERCIAL 10 . TYPE OF JOB : Original Installation Alteration/Addition/Repair BD 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11 . LOCATION OF JOB Oa &Q lt Ile, a ae— NO . STREET,._j APT. NO 12 . TYPE OF INSTALLATION /)cjo 13 . SIZE OF MAIN FEEDER 113 S E U ygk(IJW, If 14 . NO . OF LIGHT LOOPS , 15 . NO. OF HEAT LOOPS 16 . NO . OF POWER LOOPS q 17 . NO. OF LIGHT OUTLETS /oZ 18 . NO. OF HEAT CIRCUITS 19 . NO . OF POWER OUTLETSc2 20. NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS 22 . NO. OF POWER CIRCUITS_ 23 . NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS 26 . NO . OF PANELS 1 27 . TOTAL WATTAGE 28 . NO. OF POWER FEEDERS 29 . NO. OF SWITCHES (10 30 . A/C LOAD 31. SIZE OF POWER FEEDERS 32 . NO. OF FIXTURES /off- 33 . TOTAL HORSEPOWER 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : zns. M)P, -U ijdkilatlion6-r LICENSE NO.SIGNATURE OF APPLICANT DATE PHONE NUMBER: rs.r--++.+-m r--...;..rmsr+..,...,t...-,.--.,....-^+'..°.'_x?°1.,;,+=r^o•-R"^^..c-, :vT".;"" or_.'+---n.s. -s-t^fc.'fr '-.-r -.!>F-r- ."a-_+rM.F-_.-ct_ .....,.. Lot No. Building Permit I eedwir T mporary Service Permanent Service Pursuant to Permit No. This Certifies that the Electrical Work for which the above named Permit was granted has been duly inspected and Is hereby approved. Owner I elf ,S Electrician 1 Q S Street -J, Building Inspector PERMIT NO. q0,07-3 DEPARTMENT DECISION A P P L I C A T I O N F 0 R Application is hereby : PLUMBING PERMIT TOWM OF SOUTH WINDSOR C;PRO DISAPPROVED BUILDING INSPECTION DEPT. 2 SZ 644-2511 Ext. 230 a e Building Inspector Application must be printed or typed. 1. LOCATION OF JOB: FEE SCHEDULE 2. OWNER: 3. ADDRESS: Zo7 Si ,? C " Over $1 , 000 -10.00 t dfl Go per $1 ,000 or 4. APPLICANT: d fraction thereof 5. ADDRESS: F3x 6. EST. COST: $ 3 7. IS THIS A CONTRACT COST? YES NO JD 8. FEE ENCLOSED: $ 'J' 9. TYPE OF BUILDING: RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: ORIGINAL ALTERATION INSTALLATION ADDITION REPAID. BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: GENERAL PLUMBING 12. KIND OF INSTALLATION: 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS11Z-(;,/ STYLE 15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS 16A. NO. OF SHOWERS 1 zJ6if 17. NO. OF LAVATORIES 18. NO. OF SINKS 19. DISPOSAL / 19A. DISWASHER 20. NO. OF CONDUCTORS_ SIZE 21. NO. OF STACKS / SIZE 3 el 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? ' f 27. SIZE OF WINDOW 3xX 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? GtfC'-- 31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS 32. REMARKS AND FURTHER DETAILS WATER HEATER 33. TYPE 34. MANUFACTURER TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE LBS. 40. MANUFACTURER 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE 38. TYPE 42. MANUFACTURER Av e7.-z LICENSE NO. DATE SIGNATURE OF APPLICANT PHONE NO. O 7 FOR OFF CE USE ONLY APPLICATION FOR HVAC PERMIT DATE:5 Z- N0. TOWN OF SOUTH WINDSOR EST.COST:DU. BLDG. PERMIT NO. 57V 1540 SULLIVAN AVENUE FEE 3 V SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 0 - $19000 - $10.00 1000 or fraction LOCATION OF BUILDING 3 / ,ji /j`r J a thereof - $10.00 ern Ur b ZS EST ' <1 t-ce - `3 OWNER ADDRESS TOWN PHONE NO. HVAC CONTRACTOR ADDRESS TO PHONE NO. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM WW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC ,/ WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE --' OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RAD TION TOTAL IATION SA DESIGN TEMP. OUTSIDE C OF INSIDE U °F DIFFERENCE °F TOTAL HEAT LOSS (BTUH) QZ HEAT LOSS SHEET MUS ACCOMP APPLI ION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): G SAelAell GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) 4Q- IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE F TOTAL HEAT GAIN (BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT): TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: 3eoll 2- STATE LICENSE - NAME & TYPE #9AVE S GNATURE OF APPLICANT APPROVED DATE BD 4A 11/88 I - 8 - R CALCULATION SHEET ISM (Modern Method) Copyright 1977 by The Hydronlcs Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL.A COL.s 1 COL.C COL.D COL.E COL.F COL.G 1 ROOM cc O H L W H L W H L W H L W H L W Oesign Water Temp. 2 ROOM DIMENSIONS, FT.U BTUH per F t of 3 LENGTH EXPOSED WALLS,FT. 4 Radiation Selected 41 WINDOW AND OUTSIDE DOOR AREA LL BTUH STUN BTUH BTUH BTUH 5 WALL CONSTRUCTION ROOM LIN.FT.OF Table 9,Lino 3 x H) TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED Bottom of table used f r Line 6) 7 CEILING CONSTRUCTION C Table 9. L x W) B FLOOR CONSTRUCTIONt Table 9, L x W r Lin. Ft) E 9 COLD PARTITION CONSTRUCTION F Table 9, L x H)G 10 c 1 Well(With Openings)O Ho0; r+ 2 Wells(With Openings) A J 3 Wells(With Openings)or Ent. Hall I J 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K COL,A COL.0 COL.H COL.1 COL.J COL. K COL.L TOTAL BTUH TOTAL OF BUILDING RADIATION 1 ROOM E AT SELECTED O H L W H L W H L W H L W H L W DESIGN TEMP.* 2 ROOM DIMENSIONS. FT DIFFERENCE 3 LENGTH EXPOSED WALLS, FT 4 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9, Line 3 x H) TOTAL 20% 6 TYPE OF GLASS Bottom f table used for Line 51 tFOR 7 CEILING CONSTRUCTION Table 9, L x W) GROUND OR FILL AT CONCRETE FLOOR ON GRADE LEVEL,USE LINEAR B FLOOR CONSTRUCTIONf FEET OF EXPOSED EDGE Table 9, L x W r Lin Ft.) 9 COLD PARTITION CONSTRUCTION Table 9, L x H) 10 _ 1 Wall(With Openings)G C 2 Walls(With Openings) oXJ 3 Walls(With Openings)or Ent. Hall I+ 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE FORM 1503 This form is available from The Hydr nice Institute,36 Russ Place,Berkeley Heights,N.J 07922 011OTECH INC. ROCKVILLE, CONN. 871-7802 Page 1 JOB NAME: THE CAMBRIDGE STREET DESIGN CONDITIONS TOTAL BLDG. HEAT LOSS/GAIN PHONE TOWN CONNECTICUT BLDG :Heating: 80 deg f.t/d BLDG Heat Loss BTU 30,792 Estimator: NOTES:Cooling: 20 deg f.t/d BLDG A/C Gain BTU 28,973 Room 1 Room 2 Room 3 Roos 4 Room 5 Roos 6 Room 7 Room 8 Room 9 Room 10 Room 11 Room 12 AREA NAME: FAMILY LAY KITCHEN BR 1 BR 2 CLO/BA BR 3 Outside Wall Length! 54.0 12.0 35.0 24.0 25.0 16.5 19.5 0.0 0.0 0.0 0.0 0.0 Outside Wall Height; 0.0 9.0 0.0 0.0 9.0 0.0 9.0 8.0 8.0 8.0 8.0 8.0 Sq/Ft S or W Glass : 15.0 6.0 15.0 15.0 15.0 0.0 15.0 0.0 0.0 0.0 0.0 0.0 Sq/Ft N or E Glass ! 28.0 0.0 9.0 28.0 15.0 0.0 15.0 0.0 0.0 0.0 0.0 0.0 No of Doors 1.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Floor Width i 13.0 12.0 13.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Floor Length 14.0 8.0 12.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Roof Width 0.0 0.0 0.0 13.0 11.0 16.5 10.5 0.0 0.0 0.0 0.0 0.0 Roof Length 0.0 0.0 0.0 11.0 14.0 6.0 9.0 0.0 0.0 0.0 0.0 0.0 Area Cubic Feet 11456 768 1,248 11144 11232 792 756 0 0 0 0 0 Gross Wall sq/ft 432 96 280 192 200 132 156 0 0 0 0 0 Net Wall sq/ft 368 90 256 149 170 132 126 0 0 0 0 0 Wall Heating BTU 2,061 504 11434 834 952 739 706 0 0 0 0 0 Wall Cooling BTU 736 ISO 512 298 340 264 252 0 0 0 0 0 S/W Glass sq/ft 15 6 15 15 15 0 15 0 0 0 0 0 S/W Glass Heating BTU 744 298 744 744 744 0 744 0 0 0 0 0 S/W Glass Cooling BTU 186 74 186 186 186 0 186 0 0 0 0 0 S/W Glass Solar BTU 11200 480 1,200 11200 11200 0 11200 0 0 0 0 0 N/E Glass sq/ft 28 0 9 28 15 0 15 0 0 0 0 0 N/E Glass Heating BTU 11389 0 446 11389 744 0 744 0 0 0 0 0 N/E Glass Cooling BTU 347 0 112 347 186 0 186 0 0 0 0 0 N/E Glass Solar BTU 11120 0 360 11120 600 0 600 0 0 0 0 0 Doors sq/ft 21 0 0 0 0 0 0 0 0 0 0 0 Door Heating BTU 538 0 0 0 0 0 0 0 0 0 0 0 Door Cooling BTU 160 0 0 0 0 0 0 0 0 0 0 0 Floor sq/ft 182 96 156 143 154 99 95 0 0 0 0 0 Floor Heating BTU 2,912 11536 2,496 0 0 0 0 0 0 0 0 0 Floor Cooling BTU 0 0 0 0 0 0 0 0 0 0 0 0 Roof sq/ft 182 96 156 143 154 99 95 0 0 0 0 0 Roof Heating BTU 0 0 0 343 370 238 227 0 0 0 0 0 Roof Cooling BTU 0 0 0 143 154 99 95 0 0 0 0 0 Lights Cooling BTU 155 82 133 122 131 84 81 0 0 0 0 0 Appliance Cooling BTU 191 101 164 150 162 104 99 0 0 0 0 0 People Cooling BTU 177 93 152 139 ISO 96 92 0 0 0 0 0 Latent Cooling BTU 945 498 810 742 799 514 491 0 0 0 0 0 Yentilation Heat BTU 11376 421 922 596 506 176 436 0 0 0 0 0 Ventilation Cool BTU 941 272 653 801 704 209 591 0 0 0 0 0 Duct Heat Loss BTU 541 166 362 234 199 69 171 0 0 0 0 0 Duct Cool Loss BTU 370 107 257 315 277 82 232 0 0 0 0 0 Area Heating BTU 9,560 2,924 61404 4,141 31514 11222 31027 0 0 0 0 0 Area Cooling BTU 61537 1,888 4,539 5,563 4,889 1,453 4,104 0 0 0 0 0 Area Air Heating CFM 126 38 84 54 46 16 40 0 0 0 0 0 Area Air Cooling CFM 218 63 151 185 163 48 137 0 0 0 0 0 TTL Building. Square feet-> 925 Heating Air Changes/Hour -> 3.29 TTL Building. Cubic feet-) 7,396 Cooling Air Changes/Hour -> 7.83 TTL Building Heating CFM -> 405 Heating CFM per SO/FT ->0.44 TTL Building Cooling CFM -> 966 Cooling CFM per SQ/FT ->1.04 0E/10/B 1 HEAT I Ni3/r-:OOL I NG BTU ESTIMATE: I' ll, f dg c CA i . Doe r. I GIB I 60U1came AA le III/=15L MiAll Ft Al o 1P, 6 00/o ro CA 13 ZE QS•BL11L-T LE•END --— F 1 pRA14.1 cn z WATER S6RN- CONN GRID NORTH z1•'s DIME1.lS10 "W"" 1GE m cC132.S Spe.:f[- F.Lev* S — SAN ITAW SEW E R NOTES: r•..CCi"I"oUR. LECTRI..SE tV GE 0• (>EGw- 1. REFERENCE IS MADE TO THE FOLLOWING MAPS: AB&SIO PEEL SILO" WIL.Dr-Dr PEACHBROOKE, ZONE DISTRICT DRZ, APPLICANT BROM BUILDERS, INC., 207 WEST TOWN ST., NORWICH, CONNECTICUT, (TELEPHONE: (203) 880-7106) PROPERTY OF NORMAN P. PRIEST, SULLIVAN ANVENUE - CONN. ROUTE 104, SOUTH WINDSOR, CONNECTICUT, DATE: MARCH 13. 1891, REVISED THRU 3 14Wq w, SCALE: (AS SHOWN), SHEETS 1 THRU 15 OF 15. PREPARED BY DAVID L. STEIN, LS., CERTIFIED BY DAVID L. STEIN, LS AND THOMAS STEVENS. PE 6 I.S. I HEREBY DECLARE THAT THIS MAP IS SUBSTANTIALLY REVISED PLOT PLAN LEGEND CORRECT THIS MAP AND SURVEY WERE PREPARED IN 8 9ZACCORDANCEWITHTHESTANDARDSOFACLASSA-2 LOT 3(A1P1Pta 1 Vr) ------• PROP. CONTOUR SURVEY AS DEFINED IN THE -RECOMMENDED STANDARDS EXIST. CONTOUR FOR SURVEYS AND MAPS IN THE STATE OF CONNECTICUT" PROP. ELEVATION ARED ANb ADOP ED BY THE CONNECTICUT ASSOC. P E A C H B R O O K E 00.0 EXIST. ELE VATIO F LAND URV ON SEPTEMBER 13, 84. S 6" SANITARY G j Z PREPARED FOR W— WATER LINE F-- 4" FOOTING DRAIN 1.. tiTFI .S 1S 1 D BROM BUILDERS INC. A%, ., W DAVID 1.. S 11AN, LAND S11RV1.'YOR JUN .. 9 1992 South Windsor BUILDING DEPARTMENT p,ctor do TLLrry,y'' xax a • r/Yp.•i DA