Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2249 Ellington Road (3)
DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERNUT# Application is hereby: TOWN of SOUTH WINDSOR BUELDING DEPARTMENT Blda Permit # 1540 SULLIVAN AVENUE 7 644-2511 ext. 230 Date Building Inspector Application must be printed or typed Location ofjob a q c> a Street No. UStreet Lot No. FEE SCHEDULE 0 - $1,000 - $12.00 Floor Apt. No. Over $1,000 12.00 per$1,000 OWNER I I I or any fraction thereof ADDRESS So L)±Ib W,"'n a 2 0 o l OWNERS PHONE# APPLICANT 1-toin,(4 M eJ)(2v?f 4L7J v ADDRESSA0 B Z2-1z I)a 76n) ro o(. o C"6 7ESTIMATEDCOST4P 5co IS THIS A CONTRACT COST?U YES NO FEE ENCLOSED $o26 SpR-CO TYPE OF JOB: 7/ Original Installation Alteration/Addition Repair Revised 11/95 APPLICATION FOR HVAC PERMIT(Continued from rcvcrsc side) TYPE OF SYSTEM TYPE OF BUILDING HEATING RESIDENTIAL lz A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS.HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION ,3 TOTAL RADIATION` DESIGN TEMP. OUTSIDE F INSIDE 7 DIFFERENCE F TOTAL HEAT LOSS(BTUH) Q HEAT LOSS SHEET MUST ACCOMP PLCATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) TYPE OF FUEL o01i GPM j.da GAS-INPUT ELECTRIC-KW OIL TANK SIZE&LOCATION INSIDE V OUTSIDE CAPACITY LPG TANK CAPACITY AIR CONDITIONING DESIGN TEMP. OUTSIDE F INSIDE F DIFFERENCE F TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE&MODEL NO.) Pe_.,Cand en sex- Aa :kafA ler Modd H 4 4 -Kff .3d TONNAGE COOLING CAPACITY(BTUH)_.10 ( VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK l n(_ 116Z c I\J_N 0 Zc e_, A .. .cev,)+rc,,J OAS fiIC1i THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. it STATE LICENSE-NO. NAME&TYPE SIGNATURE OF APPLICANT PHONE NO. 870, 6,S'4i DATE ?/ 03 CHASE.OULETTE HVAC LOAD ANALYSIS for j QU LME'RES1 DENCE SOUTH 1 INDSOR, CL 06074 RHVACR ID$N`4L WACLoAm Prepared By: Mike Ritchie HANY MECHANICAL SERVICES,INC. 44 Lower Butcher Rd. Ellington,CT.06029 860) 872-6541 02-03-03 Rt#VJAG-RoskWid&U9M COMOWOM HVAC ,wade Rtagrsm Elite sale D"*wPM0rA,b Hany moamnic+al Ghnw.WeftEWngt*n,CT 06029 92-03-03 Page I Mkceflaneow holed Oda Project File Name: CHASE.OULETTE Sydem Input M Outdoor Outdoor Indoor Indoor Grains System 1--- Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference Winter: 4 N/A N/A 72 N/A Summer: 88 72 50% 75 28 No. Projection Offset No. Proiection Offset 1 3 1 6 0 0 2 5 0 7 0 0 3 4 0.5 8 0 0 4 0 0 9 0 0 5 0 0 10 0 0 Duct SWW Irpclls Runouts Main Trunk Duct Material: Galvanized Steel Fiberglass Duct Board Roughness Factor: 0.000300 0.003000 Pressure Drop: 0.1000 In.wg/100 Ft. 0.1000 In.wg/100 Ft. Minimum Velocity: 450.0 Ft./Minute 650.0 Ft./Minute Maximum Velocity: 750.0 Ft./Minute 900.0 Ft./Minute Minimum Height: 0 Inches 0 Inches Maximum Height: 0 Inches 0 Inches OuNde Air Data Winter Summer Infiltration: 0.900 AC/Hr 0.400 AC/Hr Volume of Conditioned Space: X 6752 Cu.Ft. X 6752 Cu.Ft. 6,077 Cu.Ft./Hr 2,701 Cu.Ft./Hr X 0,0167 X 0.0167 Total Building Infiltration: 101 CFM 45 CFM Total Building Ventilation: 0 CFM 0 CFM System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 14.21 = (1.10 X 0.994 X 13.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 18.87 = (0.68 X 0.994 X 27.91 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 74.34 = (1.10 X 0.994 X 68.00 Winter Temp. Difference) RI#SAC-ReskWAIal&UgIO Cwnnwc 1 HVAC-,aads-PWWam Mite Software Vevelo #i* Hany Mechanical Chasse.Oulelte Ellis on,CT OSM 02-03-0-3 Page 2 - Room Lid Summary Repo System#1 Raam Load Sur mmy Htg Htg Run Run Clg Clg Clg Zone Clg Air Room Area Sens Rad Duct Duct Sens Lat Nom Adj Adj Sys No Name SF Btuh Len Size Vel Btuh Btuh CFM Fact CFM CFM Zone 2--- 1 Den 144 2,553 4.4 1-4 618 1,179 341 54 1.00 54 54 2 Bath Rm 64 1,307 2.3 1-4 188 358 55 16 1.00 16 16 3 Bedroom 2 180 4,691 8.1 1-5 572 1,705 452 78 1.00 78 78 4 Bedroom 1 180 4,691 8.1 1-5 572 1,705 452 78 1.00 78 78 5 Kitchen 180 4,303 7.4 2-4 648 2,473 470 113 1.00 113 113 6 Laundry 60 699 1.2 1-4 443 846 0 39 1.00 39 39 7 Hall 36 172 0.3 1-0 0 48 0 2 1.00 2 2 System 1 Totals 844 18,416 31.8 8,314 1,770 380 380 380 Main Trunk Size: IOx8 in. SOOM#1 CaOlhv system summer t Cooling Sensible/Latent Serl jble Latent Total Tons Split tyh Btuh Btuh Net Required:0.840 82%/18% 14 1,770 10,084 Recommended: 0.900 77%/23% 2,483 10,797 l CHASE.OULETTE HVAC LOAD ANALYSIS l for OUL€3TE RESIDENCE . . . . 2249 ELLINGTON RD SOUTH WINDSOR, CT.4 74. I RHVACWAC Was Prepared By: Mike Ritchie HANY MECHANICAL SERVICES,INC. 44 Lower Butcher Rd. Ellington,CT.06029 860) 872-6541 02-03-03 RHMAC ResideW &-Light Conamen!NVAC Los&Rroww". Elite So Eli Harry Mechanical Chaaa.Oulette Tftokon,CT OW29 02.03.03 Ngq 2 MiscOganecs PrWecf Data Project File Name: CHASE.OULETfE system Mips Ma- Outdoor Outdoor Indoor Indoor Grains System 1-- Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference Winter: 4 N/A N/A 72 N/A Summer: 88 72 50% 75 28 bdomcd0"dMus No. Projection Offset No. Projection Offset 1 3 1 6 0 0 2 5 0 7 0 0 3 4 0.5 8 0 0 4 0 0 9 0 0 5 0 0 10 0 0 Duct S . ng.kW. fs Runouts Main Trunk Duct Material: Galvanized Steel Fiberglass Duct Board Roughness Factor: 0.000300 0.003000 Pressure Drop: 0.1000 In.wg/100 Ft. 0.1000 In.wg/100 Ft. Minimum Velocity: 450.0 Ft./Minute 650.0 Ft./Minute Maximum Velocity: 750.0 Ft./Minute 900.0 Ft./Minute Minimum Height: 0 Inches 0 Inches Maximum Height: 0 Inches 0 Inches OuNde Air Data Winter Summer Infiltration: 0.900 AC/Hr 0.400 AC/Hr Volume of Conditioned Space: X 13056 Cu.Ft. X 13056 Cu.Ft. 11,750 Cu.Ft./Hr 5,222 Cu.Ft./Hr X 0.0167 X 0.0167 Total Building Infiltration: 196 CFM 87 CFM Total Building Ventilation: 0 CFM 0 CFM System 1— Infiltration &Ventilation Sensible Gain Multiplier: 14.21 = (1.10 X 0.994 X 13.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 18.87 = (0.68 X 0.994 X 27.91 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 74.34 = (1.10 X 0.994 X 68.00 Winter Temp. Difference) RHVAG-Resid ial lght-Gamatie dO-HVAC-Loafs-ProWOM alike Sclera Dew6lopownt,M Hany Mochankmi Chose-10tileft. Eft ,CT 06M 02-03-03 Page 3 TotcdWiding Summary.toods Component Area Sen. Lat. Sen.Total Description Quan Loss Gain Gain Gain 3A Window Double Pane Clear Glass Wood Frame 149 5,585 0 4,065 4,065 11 C Door Metal Polystyrene Core 40 639 0 150 150 13E Part R-11 + 1/2"ExtPoly Board(R-2.5)1,331 3,396 0 800 800 16E Ceiling R-22 Insulation 794 2,593 0 1,409 1,409 16G Ceiling R-30 Insulation 970 2,177 0 1,184 1,184 19A Floor Over Basement/Encl Crawl Hardwood No Insulation 794 8,422 0 0 0 19H Floor Over Basement/Encl Crawl Carpet+ R-13 838 1,937 0 0 0 Subtotals for structure: 4,916 24,749 0 7,608 7,608 Active People:8 0 1,840 2,400 4,240 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 3,000 3,000 Lighting:0 0 0 0 0 Ductwork: 0 1,965 0 1,423 1,423 Infiltration:Winter CFM: 195.8,Summer CFM:87.0 189 14,559 1,642 1,238 2,880 Ventilation:Winter CFM:0.0, Summer CFM:0.0 0 0 0 0 0 Sensible Gain Total: 15,669 Temperature Swing Multiplier: X 1.00 Building Load Totals: 41,273 3,482 15,669 19,151 Cott s. Total Building Supply CFM: 717 CFM per square foot: 0.439 Square feet of room area: 1,632 Square feet per ton: 962.389 Bs bg Loods Total heating required with outside air: 41,273 Btuh 41.273 MBH Total sensible gain:15,669 Btuh 82 % Total latent gain: 3,482 Btuh 18 % Total cooling required with outside air: 19,151 Btuh 1.596 Tons (based on sensible+ latent) 1.696 Tons (based on 77%sensible capacity) Ilia . Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. l RHYAC-ResK%MW-&UOM Garnmercbl-HVAC k oWs Program Elite Sots aD*ve1oj*wt*,but- Hany it hnnicat Chaee,OWeft Ungton,CT 06029 02-03-03 Page 4 Sysfem#1 Zone#1.Summary toads Component Area Sen. Lat. Sen.Total Description Quan Loss Gain Gain Gain 3A Window Double Pane Clear Glass Wood Frame 89 3,336 0 2,667 2,667 11 C Door Metal Polystyrene Core 20 320 0 75 75 13E Part R-11 + 1/2"ExtPoly Board(R-2.5) 635 1,620 0 382 382 16E Ceiling R-22 Insulation 794 2,593 0 1,409 1,409 16G Ceiling R-30 Insulation 132 296 0 161 161 19A Floor Over Basement/Encl Crawl Hardwood No Insulation 794 8,422 0 0 0 Subtotals for structure: 2,464 16,587 0 4,694 4,694 Active People:4 0 920 1,200 2,120 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 1,200 1,200 Lighting:0 0 0 0 0 Ductwork: 0 1,249 0 780 780 Infiltration:Winter CFM: 112.9, Summer CFM:50.2 109 8,397 947 714 1,661 Ventilation:Winter CFM:0.0, Summer CFM:0.0 0 n/a n/a n/a n/a Sensible Gain Total:8,588 Temperature Swing Multiplier: X 1.00 Zone Load Totals: 26,233 1,867 8,588 10,455 Check 11149wes Supply CFM: 393 CFM per square foot: 0.495 Square feet of room area: 794 Square feet per ton: 858.569 Zam Leads Total heating required with outside air: 26,233 Btuh 26.233 MBH Total sensible gain: 8,588 Btuh 82 % Total latent gain: 1,867 Btuh 18 % Total cooling required with outside air: 10,455 Btuh 0.871 Tons (based on sensible+ latent) 0.925 Tons (based on 77%sensible capacity) RHV AG-Rtstk lal&LkjM OorrrowcM MAC L.oaft Prograin Oki Software Ow' 401oPM"It 1m Harty Mdohnnical Chn sa,OWeft ti Ungtvn,CT OSM 02-03-03 Page 5 System#1 Zone#2 Summer toack Component Area Sen. Lat. Sen.Total Description Quan Loss Gain Gain Gain 3A Window Double Pane Clear Glass Wood Frame 60 2,249 0 1,398 1,398 11 C Door Metal Polystyrene Core 20 320 0 75 75 13E Part R-11 + 1/2"ExtPoly Board(R-2.5) 696 1,776 0 418 418 16G Ceiling R-30 Insulation 838 1,881 0 1,023 1,023 19H Floor Over Basement/Encl Crawl Carpet+ R-13 838 1,937 0 0 0 Subtotals for structure: 2,452 8,163 0 2,914 2,914 Active People:4 0 920 1,200 2,120 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 1,800 1,800 Lighting:0 0 0 0 0 Ductwork: 0 716 0 643 643 Infiltration:Winter CFM:82.9, Summer CFM:36.8 80 6,162 695 524 1,219 Ventilation:Winter CFM:0.0,Summer CFM:0.0 0 n/a n/a n/a n/a Sensible Gain Total:7,081 Temperature Swing Multiplier: X 1.00 Zone Load Totals: 15,041 1,615 7,081 8,696 Chock R xas. Supply CFM: 324 CFM per square foot:0.386 Square feet of room area: 838 Square feet per ton: 1,086.922 Total heating required with outside air: 15,041 Btuh 15.040 MBH Total sensible gain: 7,081 Btuh 81 % Total latent gain: 1,615 Btuh 19 % Total cooling required with outside air: 8,696 Btuh 0.725 Tons (based on sensible+ latent) 0.771 Tons (based on 77%sensible capacity) RHVAkC-R*sicWAIOl&- -Gomr WdW HV l,*W Rowsm Elite softwwe 0-w-wopmew,#Ot- Hater Ma4hanical Chase,OWeft EMf gtort,CT OW29 02-0"a Room hood-Summary Reports SSydem#1 Room Load Summcffy Htg Htg Run Run Clg Clg Clg Zone Clg Air Room Area Sens Rod Duct Duct Sens Lot Nom Adj Adj Sys No Name SF Btuh Len Size Vel Btuh Btuh CFM Fact CFM CFM Zone 1--- 8 Kitchen 132 5,426 9.4 2-4 685 2,615 482 120 1.15 138 120 9 Living 216 8,962 15.5 2-5 456 2,721 612 124 1.25 156 124 10 Bath 1 56 966 1.7 1-4 77 146 0 7 1.00 7 7 11 Bedroom 1 120 5,042 8.7 1-5 598 1,782 439 81 1.25 102 81 12 Bedroom 2 132 3,826 6.6 1-4 380 725 104 33 1.00 33 33 13 Bedroom 3 108 1,574 2.7 1-4 284 541 230 25 1.00 25 25 14 Hall 30 437 0.8 1-0 0 58 0 3 1.00 3 3 Zone 1 Subtotal 794 26,233 45.2 8,588 1,867 393 462 393 Zone 2--- 1 Den 120 2,198 3.8 1-4 466 890 334 41 1.00 41 41 2 Bath Rm 64 1,183 2.0 1-4 157 300 52 14 1.00 14 14 3 Bedroom 168 2,771 4.8 1-4 651 1,243 334 57 1.00 57 57 4 Living 210 4,448 7.7 1-5 488 1,455 439 67 1.25 83 67 5 Kitchen 180 3,724 6.4 1-6 545 2,341 456 107 1.00 107 107 6 Laundry 60 545 0.9 1-4 421 804 0 37 1.00 37 37 7 Hall 36 172 0.3 1-0 0 48 0 2 1.00 2 2 Zone 2 Subtotal 838 15,041 25.9 7,081 1,615 324 340 324 System 1 Totals 1632 41,273 71.2 15,669 3,482 717 803 717 Main Trunk Size: 14x10 in. syd*M#1 COO&V SMMary: . Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required:1.596 82%/18% 15,669 3,482 19,151 Recommended: 1.696 77%/23% 15,669 4,680 20,349