Loading...
HomeMy WebLinkAbout22 Spruce LaneJ 13 zI23 7 DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT Application is hereby:TOWN OF SOUTH WINDSOR PERMIT# BUILDING DEPARTMENT 9 F y PROV 1540 SULLIVAN AVENUE Bldg.Permit# 7 (j 3 644-2511 ext. 230 Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: 9 0/00 0-$1,000=$15.00 Street No. IF Street 7Lot No. Over$1,000= 15.00 per$1,000 or any fraction thereof Tenant Designation Ap APPLICANT J/),•i c L- APPLICANT ADDRESS `s u APPLICANT PHONE# SCE w OWN S OWNER q OWNER ADDRESS -3 jA-te, Ayy- 4 A OWNER PHONE 7 — 3 a :2 C ESTIMATED COST$ 9, a/ IS THIS A CONTRACT COST? es No FEE ENCLOSED$ O TYPE OF JOB: OR-C ew Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: HEATING PORESIDENTIAL COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT-BTUR) NET RATING(OUTPUT-BTUH) TYPE OF FUEL OIL-GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENC F TOTAL HEAT GAIN(BTUHII3 Q jr L(HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH)GY/ VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. Crl3057f'ZZ CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE C-l0'G C Short Form J b: Date: a Entire House By: O AUTOMATIC TLC 64 OAKLAND AVE,E.HARTFORD,CT 06108 Phone:568-1200 Project • For: REV HAYES 22 SPRUCE ST, S. WINDSOR, CT Phone: 644-8439 Design Information Htg Clg Infiltration Outside db (OF) 0 95 Method Simplified Inside db(°F) 70 70 Construction quality Average Design TD (OF) 70 25 Fireplaces 0 Daily range M Inside humidity(%) 50 Moisture difference (gr/lb) - 21 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Efficiency 80 AFUE Efficiency 0 EER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Heating temperature rise 0 OF Total cooling 0 Btuh Actual heating fan 1164 cfm Actual cooling fan 1164 cfm Heating air flow factor 0.000 cfm/Btuh Cooling air flow factor 0.054 cfm/Btuh Space thermostat Load sensible heat ratio 94 % ROOM NAME Area Htg load Clg load Htg AVF Clg AVF ft2) Btuh) Btuh) cfm) cfm) WHOLE HOUSE 1008 0 17535 0 944 ENTRY 240 0 4094 0 220 Entire House d 1248 0 21629 0 1164 Ventilation air 0 0 Equip. @ 1.00 RSM 21629 Latent cooling 1427 TOTALS 1248 0 1 23056 0 1164 Bold4tallc values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wriyljtsoft Right-Suite Residential J8 5.8.20 RSR31194 2003-May-23 11:07:30 ACC*\ Proiect2.rrp calc=MJ8 Orientation=N Page 1