Loading...
HomeMy WebLinkAbout22 Natsisky Farm Roado 0 T BUELDING INSPECTOR of the APPLICATION FOR PLAN EXAMINATION ANDTOWNOFSOUTHWINDSOR„BUILDING PERMIT z IMPORTANT — Applicant to complete all items in sections: 1, it, III, IV, and IX.O ZONING A—3 0IAT (LOCATION) DISTRICT LOCATION NO.) 4)-ANDOFBETWEENj BUILDING CROSS STREET) CROSS sTR9 MOUNTAINVIEW ESTATES a-BLxK LOT 199 a g(' lSUBDIVISIONLOTS_ II. TYPE AND COST OF BUILDING — All applicants complete Parts A — D A. TYPE OF IMPROVEMENT D. PROPOSED USE — For"Wrecking" most recent use rrnn 1 ETNew building Reside tial Nonresidential 2 Addition(l/residential, enter number 12 One family 16 Amusement, recreational o/new housing units added, i/any, 13 Two or more family — Enter 19[D Church,other religiousinPartD. 13)' number o/units— — — ——_._20 Industrial3 Alterati n (See 2 above) 14 lTransienthotel, mote ,21 Parking garage4 Repair, replacement or dormitory — Enter number 5 Wrecking 01 multifamily residential. o/ units ——————— —--r 22 Service station, repair garog enter number o/units in building in 15 Garage 23 Hospital, Institutional Part D, 13) 16 Carport 24 Office, bank, professional 6 Moving (relocation) 7 Foundation only 17 Other — Specify 25 Public utility 26 School, library, other educational B. OWNERSHIP 27 Stores, mercantile B Private (individual, corporation, 29 Tanks, towers n npr fit Institution, etc.) 29 Other — Speci/y 9 Public(Federal, State, or local 9 vernment) C. COST Omit cents) Nonresidential — Describe in detail proposed use of buildings,e.g., I d processing plant, machine shop, laundry building at hospital,elementary 10. Cost f improvement................ . school, secondary school, college, parochial school, parking garage I r, department store,rental office building, office building of industrial plant. T be installed but not included If use of existing building is being changed,enter proposed use. in the above cost a. Electrical....................... b. Plumbing ....................... c.Heating, air conditioning......... d. Other(elevator, etc.)............. 11. TOTAL COST OF IMPROVEMENT s 9qQ0 O III. SELECTED CHARACTERISTICS OF BUILDING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS a 30 Mas my(wall bearing) 40 /0 Public or private company 48• Number of stories.....e.......... 31 p W d frame 41 Private (septic tonk, etc.) 49• Total square feet of floor area, all floors, based on exterior 3 q 732 Structural steel dimensions ..................... 33 Reinforced concrete H. TYPE OF WATER SUPPLY O34 Other — Specify 42 Publlc or private company Total land area, sq. It. ........... 43 Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES F. PRINCIPAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL 51. Ericlosed...............6.0..... 35 F7 Gas Will there be central air 52. Outdoors.9*so o.......so..*..... 360011 c nditi ning?L. RESIDENTIAL BUILDINGS ONLY 37 Electricity 44 Y s 45[DIN 53. Number f bedrooms.............. 36 Coal 39 Other— Specify Will there be an el vator? Fult..........54. Number of 46 Yes 47 V No bethr oats lPort!o l........ IV. IDENTIFICATION — To b completed by all applicants Name Maili nip address — Number, street, city, and State ZIP code T I. N I' owns Dart Hill Realty Inc. 658 Ellington goaaor Lessee South W'n 2. Same Contractor 3. Architect or Engineer The owner of this building and the undersigned agree to conform to all applicable laws of this jurisdiction. Signatu,f of applicant Address Applicati n dot 00 NOT WRITE BELOW THIS LINE V. PLAN REVIEW RECORD — For office use Plops Review Required Check Plan Review Date Plans By Date Plans By NotesFeeStartedApproved BUILDING PLUMBING MECHANICAL ELECTRICAL OTHER VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Permit or Approval Check ObtDoined Number By Permit or Approval Check ObtDoined Number By BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER VII. VALIDATION Building Permit number Bui Iding P rmit issued ///2 y/19 Building S , l` Permit Fe $ J 3 CY-6 Cc (D r ve TITLE I TOWN OF SOUTH INDSOR BUILDING PERMIT Date Nov. 24 1986 Fee Paid $.5 0.4 .0 0 Est. Value .8 4,0 0 0 Permit No 15565 on the side of Lot #122 Natsisky Farm RdStleet Street No. 22 Owner Dart Hill Realty Inc _ Applicant Muriel aac u e s CERTIFICATE OF OCCUPANCY ISSUED: Date No. 7Qti Fee Paul CLASSIFICATION pwP 1 I i n cr I BUnDj NG PERNOrr NV 15565 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn. Nov. 2 4 1§6 94is 'to to Certif1j, That Dart Hill Realty Inc. is hereby granted permission to Dwelling at estimated value of 0 4 ,n n n on the side of Lot #122 NatsiskY Farm Road Saves on land owned by Dart Hill Realty Inc. Said Work to be as described in Application No. 15865 and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH VIMSOR. Ipsued Nov.106 Building Inspector. Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: `When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compelled to reason therefor." Dwelling - Lot #122 Mtn.Vw. 4 11/24/86 Dart Hill Realty Inc . 22 Natsisky Farm Road permit # 15565 Electrician Rich. Barrett 9549 Heating Contr. 64, 0' ' plumbing ItGaeton Grondin 7243 Oil Burner 7863 Certificate of Occupancy Sewer Permit Plot plans apprd. per Engr. 7 7N'S/PECTIOI"EPORT Permit # Jo e2 1 Footing 2 Foundation 3 Framing 4 Wiring l C F1 l7 A 1 5 Plumbingkj 6k6 NJ n 6 Heating A 7 Lathing 8 C.O. y63 Permit No. C TOWN OF SOUTH WINDSOR SOUTH WINDSOR, CONN. Permit N 4 7863 Certificate of Occupancy TH O C771 .-Y that the '="r' , at No.r" f d in the-'. own of South Windsor, Connecticut, has been erected and completed in accordance w' h the yB ilding Code and Zoning Regulations of i the Town of South Windsor, and is hereby app ve fo occupy. I Building Inspector IOwner, Builder Fee Paid Date w 19 I REINO E. HYYPPA 15 ASSOCIATES CIVIL ENGINEERS a LAND SURVEYORS GLASTONBURY, CONN. Do i U o iG' P i F0\0- 01?- 4)p I LOT LINES FROM MAP OW FILE TITL-ED, OPEM SSW-F- SUe VISION A-30 Z01 PLOT PLAN 5ECTIOrj 4 MOUNTWNVIEW ESTATES SOUTH WINDSOR,Gpv 1J."BY Retwo E. H"PPA!ASSocIATES 5CALE I"=40 DATE:4-9-8lo MAP NO.ISO-a3 I V SHEET Z OF V3 5HEET S Rev PREPARED FOR Irck-A. LOCA f-j,- DART HILL REALTYQZNdv«T,s w-TN INCfl%)PEC'c I CERTIFIED SUBSTANTIALLY CORRECT SOUTH WINDSOR, CONN. SCALE : 1"-40' DATE: It-tb-&(a 58-a5-22 A p ro p JQ ATE= G .: P P ., I'>>• R i ss S BUILDING PERMIT CHECK LIST ' Applicant Building Permit No. Address Date Submitted Lot No. /zZ,-Reviewed by P ro j ec t Atevlv Z,i ,/Ll' f=sl,z Date In accordance with the Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include : Approved Denied N/A 6-471. Name, address & phone number of owner/ applicant. 33 v6 8 2. Name , address & phone number of plan preparer. t/3. Zoning information - i.e. zone, open space, floodway, etc. 4 . Plot plan at 1" = 40 ' scale. a. Subdivision reference, abutting properties , etc. b. Easements of record. c. Lot description, bearings, distances , building lines, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate. e. Building location with dimensions. Elevations of proposed finish floor, garage floor & center line of road at driveway. f. Elevations of gravity drainage systems , sanitary & foundation drain at the house and the street. g. Tentative utility location gas, electric, water, etc. h. Title block with name and address of preparer, date appropriate certification, live seal and signature. 5 . Sedimentation and erosion control. 6 . Special Planning & Zoning, Inland/Wetlands considerations. (Plans on file w/Town Clerk) BUILDING DEPT. PZC IWA/CC WPCA OTHERS COMMENTS: 9549 ELECTRICAL APPLICATION Application No.110 5 8 on the side of Lot #122 Natsisky Farm Rd.Strwt Street No. 22 Owner Dart Hill Realty_ Inc`. Electrician Ric-hard Rarrett FILED IN OFFICE OF The Building Inspector 11 2 7 19_$Z i INsrEcrION. UrNo Electrical Work shall be started until a Per. mit is granted by the Building Inspector. In New Buildings no wiring shall be started until the plumbing and heating pipes, and the fire stops (if of wood) are installed, without a special permit from the office of the Building Inspector. Electrical Permit No. Master License No. . ................................... TOWN OF SOUTH WINDSOR Building Permit No. Date FiledBUILDINGDEPARTMENT Date Final Approval . . ........ .. ................... APPLICATION FOR ELECTRICAL WORK Electrical Inspector JOB LOCATION: Co........... ..... .... ........................................A" O OWNER: Umi f .Iaj Side of Be"t-w-'e' en .. and Name of Building Owner Gam....Cal)A Address If work is for Lessee--Give name Address ................@r........................... ............. ........ ................. isBuildingnowoccupiedas (unless new) Building to be occupied as ..... .. No. of family units now Number of family units to be ..... ........ ... Is this work included in a uilding Permit? Permit Fee .......... . ......( If no Buiild,ing Per it) Permittee Business Address 4 . (,,( t.CTelephone /... . ` COST OF JNSTALLATION: ov. IV TO BE FILLED OUT BY PERMITTEE TO BE WIRED EXISTING APPLIANCES Number of light outlets to be installed Number of convenience outlets to be installed Number of present Appliance Circuits ................. . ...... ............. Number of switches to be installed Do these include Range Water Heater Number of appliances to be installed as listed below) Dryer Air Conditioner E] Oil Burner TYPE RATING NO. Range . . . . . . . . Dish Washer E] Gas Burner Well Pump E] Elec. Heaters Range Top . . . . . . Oven . . . . . . . . REMARKS: Water Heater Clothes Washer Per Clothes Dryer . . . . . Dish Washer . . . . . . Air Conditioning Motor . - Oil Burner Motor . . . . Gas Burner . . . . . . Circulator Motor . . . . Attic or Large Fan . . . Well Pump . . . . . . Electric Heat . . . . . Other . . . . . . . . I Number of new Lighting Circuits . . . . ........... .......... Number of new Appliance Circuits . . . ...........5.......... Number of Heating Circuits Number of Motor Circuits Size of present service ......... ... Size of service to be .. .......n--r) 7243 PLUMBING APPLICATION App_ . - W 6913 an the A&of Lot #122 ISTat-sisky --farm -rd . Hm 22 Owns Dart Hill Realty Inc . pkunbw Gaeton grondin RW in Offia of The BMW mg bqmmr Jan - 2R 19-.&Z No person shall rp- __ portion of the &a*p qmftm of my bwl&g except to repair66) anal a Be is scmftd by t6 Bu"n hmpe=L APPLICATION FOR PLUMBING PERMIT cC ntinu d fr m R v rs Sid ) TOWN OF SOUTH WINDSOR, CONN. 11. LOCATION OF JOB d a Ri FLOOR APT.NO.NO. STREET GENERAL PLUMBING 12. KIND OF INSTALLATION 41,C-4L' 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS _STYLE 15. NO. OF URINALS STYLE 16. NO.OF BATHTUBS 17.NO.OF LAVATORIES.=18. NO.OF SINKS•— 19. NO. OF WASHTUBS r 20. NO.OF CONDUCTORS SIZE 21. NO. OF STACKS SIZE 22. AREA OF ROOF 23.N0. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW?27. SIZE OF WINDOW 28. IF NO WINDOW,WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. ARE SEWAGE AND WATER FACILITIES AVAILABLE? SIGNATURE ADDRESS AIR -SDtalT LICENSE NO. 6 ESTIMATED COST TELEPHONE 4:' ol OWNER ADDRESS 2LL/'- ( T Q O soar lwQS6 WATER HEATER 31. TYPE S ti 32. MANUFACTURER 12 Zc e G1e TANK SAFETY DEVICES r 33. CAPACITY 37. TEMPERATURE RELIEF VALVE 34. TEST PRESSURE 38. MANUFACTURER_ 35. WORKING PRESSURE 39. PRESSURE RELIEF VALVE 36. TYPE 40. MANUFACTURER ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE OWNER OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. 1/L 11 e.nom-2 ATE SIGNATURE OF APPLICANT nisq,PERMIT Application For 7-.53 DEPARTMENT DECISION Heating Permit 1c W 3 0 APPLICATION IS HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS 4'APPROVED DISAPPROVED TOWN OF SOUTH WINDSOR cc 00 w DATE CHIEF INSPECTOR APPLICATIONS MUST BE PRINTED OR TTPED. B[CIN WITH NUMBER HE BELOW O 1. LOCATION OF JOB 1-a T 1616 te--A T q1s' A-f'J-,62 NO. STREET o a V y LOT NO. FLOOR APT. NO. O Q SI ~ 4j s. OWNER STAY Z: S. ADDRESS 6-03 452 461 9'To - O 4.PHONE fn S. APPLICANT , T ' d 02 s. ADDRSSS ,9 9J -S Teti G y 01 42 S d 7.PHONE w S. LICENSE N0. 3 Q ' )L r'- O EXPIRATION DATE OF LICENSE d 5' 10. ESTIMATED COST S 3 U 0 IS THIS A CONTRACT COST? YES NO 00 ts. FEE ENCLOSED S V 12. TYPE OF BUILDINCk RESIDENTIAL COMMERCIAL W a ts. TYPE OF JOB: INDUSTRIAL IV RIGINAL ALTERATIONZrINSTALLATIONADDITION REPAIR APPLICATION FOR HEATING PERMIT (Continued from Reverse Side) 11. LOCATION OF J08(1 NO.TRi FLOOR AFT.N 12. TYPE OF INSTALLATION: OIL BURNER ELECTRIC VENTILATION SPRINKLER C3 GAS BURNER STACK Cl INCINERATOR MISCELLANEOUS IDENTIFY SIZE LOCATION SIZE SIZE 13. OF TANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. 4-T/C4 B.T.U. OR SQ. FT. NET ` d 0—L2 B.T.U. OR SQ. FT. GROSS_a4_$4FI RING RATE iFLOORSTOBEHEATEDNEWOROLDBUILDINGBUILDING _1-r INSULATED - YES OR NO TYPE OF WALL ff )< Lz INSULATION 3 / ROOF OR CEILING J INSULATION AVG. SYSTEM WATER TEMP. -,l 4 U B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS. OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SO. FT. OR B.T.U. DESCRIPTION OF WORK 15. TO BE DONE- t . HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS): ow ilz[ wlNCowi AREA - SQUARE FEET T•U. 'T.U.DISTRIBUTION INSTALLED A N O OOORS VOLLWA TOTAL TOTAL J r f L R[ IST[R ROOM L w M ANO ( GROSS GLASS NET WALL CEILING FLOOR CU.FT. A TEMP. R CORTo!D t F I. TYPE AMC SIZE RAO. R L[AO[R SIZ[ < MALL 'Ct IINFILT.) OIFF. F :M 30• FT. FREE AREA TOTALS A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND B.T.U./HR. C. PIPING. OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY: NAME ADDRESS SUBCONTRACTORS AND te. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE:(OWNER) OR (AGENT) OF TH S PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. DATE SIGNATURE OF APPLICAWr BURNH AM CORPORATIOIN Heating & Cooling Division - Irvington, N. Y. 1=B=R CALCULATION SHEET 1503 Copyright 1965 Ity the Institute f Boil..and Rodiator Manufacturer,, 393 Seventh Ave.,New York,N.Y. 10901 O1wlER AOOREES- 1.2.2 DESIGN TEMPERATURE DIFFERENCE F. DATE A:GOL.A COL.s COL.C COL. D COL. E COL. f Ir COL. G ROOM1 fir'-' ' AP TOTALS RADIATION O - will " L • N Ld W N L 11 H L M "• L W FROMLINE 12 SELECTED 2 RDOM DIMENSIONS. FT. F' ow L 4 LENGTH EXPOSED WALLS. FT, t fL Z l 1 C 4 WINDOW AND OUTSIDE DOOR J REA 66 BTL : BTU" dTUN STUN STUN D— 7 S WALL CONSTRUCTION TYPE F GLASS C?>l eOhod7jCxJLINQCONSTRUCTIONi s IFLOOR COIE;TRUCTION 1 jC6LD PARTITION CONSTRUCTION 0 10 J ONKNALL WITH$LAU OR EXTERIOR DOOR) Gi f s TV WALLS G 1 r, 1 THREEWALLS 11 ENTRANCE HALL 11 TOTALBTUNAT70FTEMP.DIFfERENCE• J 12 TOTAL @TUN AT DESIGN TEMP.D1F FERENCE DQ 1 G E COL. A COL. B COL.N COL. 1 COL.J COL. K COL. L L 1 R0011 t/1 ' O W W " I L M N L W - N L W N L W N L W d ^w 2 ROOM DIMENSI NS, FT. CIO U a z 3 1 OfBUILDING RADIATION TOTAL 2 LENGTH EXPOSED WALLS. FT. t 4 WINDOW AND OUTSIDE DOOR AREA DESIGILNTEMP. SELECTED DIFFERENCEBTU" STUN BTU" STUN STUN11WALLCONSTRUCTIONy D d TVPE OF GLASS 7 CEILING.CONSTRUCTION INCREASE BATHROOM TOTAL 20% FLOOR CONSTRUCTS N 1 S COLD PARTITION CQNSTRUCTION I FOR CONCRETE FLOOR OK GROUNDOR FILL ATGRAD! LEVEL. USE LINEAR FEET10JONEWALL(WWII GLASS DR EXTERIOR DOORS A OF EXPOSED EDGE TWO WA LLS Q THREEWALLS OR ENTRANCE HALL• i Q;t fir 11 TOTALOTU14AT70FTEMP.DIFFERENCE• 12 TOTAL STUN AT OESION TEMP.DIFFERENCE LOT 190:BURNHAM CORPORATION Heatlng & Cooling Division - Irvin oa N.Y. t,% t=S=R CALCULATION SHEET 1503 Cepyrisht ms byth Institute I Soilet and Rodiotor Manufocturors, 393 Soventh Ave.,Now York,N.Y. 1001 DINNER__ ADDRESS_ 40T—/-;*.72— Z2 d 1 DESIGN TEMPERATURE DIFFERENCE F. DATE 9 A COL.S COL.C COL.D COL.It COL. it COL. G ROOM 1 ROM COL TOTALS RADIATIONZFROMLINE12SELECTEDOWWNL • N L • N L M N L r N• L M t Aeon o1MCINsroNS. FT. n m Dun 3 LENGTN EXPOSED>MALLS. F7. t Z WINDOW AND OUTSNOE DDOR AREA L O QSSTUNSTUNSTUNSTUND s NULL CONSTRUCTION v t TYPE OF GLASS 7 CsILIN CONSTRUCTION FLOOR CONSTRUCTION t t OOLO PARTITION CONSTRUCTION N Cj j FT0001TINAL E Whl.Lfwtu GLASS OR CzT"104 DOOR) s Q/ owALLS O r...r oREtWALLSORENTRANCEHALL13TUNAT7OFTEYP.OIFFERENCE• STUN AT DESIGN TEMP.Ot F FERENCE per+ K COL. A COL. S COL.N COL.1 COL.J COL.K COL.L L t ROOM O W W N L M N L M H L M H L M N L 2 ROOM DNMENSI MS. FT. V < al hPi TF iL STU" DING TOTAL RADIATIONSLENGTNEXPOSEDWALLS. FT. t 4 = AT SELECTED WINDOW AN OUTSIDE ODOR AREA IL DESIGN TEMP. DIFFERENCE STUN BTU" STUN STUN STUN . i WALL CONSTRUCTIONNFD7 6 TYPE or GLASS FaQ a co 13 tDO 7 CEILIN ,CONSTRUCTION INCREASE IIATNROOM i' Q TOTAL 20% A FLOOR CONSTRUCTION t COLD PARTITION CaQNSTRUCTiON I F It CONCRETE FLOOR OK GROUNDOR FILL AT GRAD! LEVEL.USE LINEAR FEET10ONEWALL(WITH GLASS 011 9XT9II6011 DOOR) + F EXPOSED EDGE TWO WA L LS a or TNREEWALLS OR ENTRANCE HALL• 1t TOTAL STUN AT70FTEMP.DIFFERENCE• 12 TOTAL BTUN AT DESIGN TEMP.DIFFERENCE S nnu .cn Electric# APPLICATION FOR BUILDING PERMIT Plumbing# 22 NATS I S KY FARM ROAD HVAC # 22454 Date: Sprinkler# No. FINAL AP R VAW Estimated Cost $ God D Building fo `S COMPLETE RED BOXED AREAS Permit Fee x Engineerin TYPE OR PRINT ONLY Occupancy Fee $ Affidavit SIGN ON REVERSE SIDE Appr.for CO. Total Fee 6 TO BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR,CT Additional Cost) $ Th undersigned hereby applies to do work according to the following specifications: Job Location 02 N0 T1vki fir t Lot No. Side of Street Zone ApplicantAne t l2 ` r e n P rvi- ('h c Tel. # 2 Y3—Z%(o Address '?7 (N{C7 Ov%J/-OQ 7own /2.d WrAd ct Zip 6'01O Z Lic. # r/yG?f Owner 7eZ A NS O/1 Address 2-2 /1/A fc&+ j,n Architect Address 67 Sq. Ft. N w Area: 1st FI. 2nd FI. 3rd A. Total New Area Rooms Lavatories Bathrooms Garages JPurposeofthispermit: J I e rho?I rd? City Water C Well 0 Septic System Sewer 0 Use Group 11V 4- Construction Type Area Basement Garage Approved by Date Reveal 6/95 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked, and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone whic this building and its s i a lowed. WSigned I hereby apply for a Certificate of Occupancy for the work described in this application for the permit Signed DO NOT WRITE BELOW THIS LINE -- INSPECTION COMMENTS Electrii#13-7 4 APPLICATION FOR BUILDING PERMIT Plumbing# 7 3 22 NATS I SKY FARM ROAD Date:HVAC # No. 22714 Sprinkler# FINAL APPROVALS Estimated Cost $ b4ev" Building z 1 l/COMPLETE RED BOXED AREAS Permit Fee Eio-a 6 Engineer' TYPE OR PRINT ONLY Occupancy Fee $ Affidavit SIGN ON REVERSE SIDE I].. Appr.for CO. 6 Total Fee d G TO BUI EPARTMENT, TOWN OF SOUTH W11NDSOR,CT Additional Cost) $ Th undersigned hereby applies to do work according to the following specifications: fob Location 00 41.4 .f Lot No. Side of Street .SD Zone Applicant Tel. # Address .J 4 ll =Zip 62 Lic. # Own r &4 Address Z 2,• x2 `C4., lr k:L Architect le-w Address Sq. Ft.New Area: 1st Fl. eVel-' 2nd FI. 3rd FI. Total New Area Rooms Lavatories Bathrooms Garages Purpose of this permit: S P c a City Water ` Well Septic System Sewer,ate Us Group Construction Type a Bas m nt Garage Approved by Date Revised 6/95 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper ist et ' , i yard lin nd required distances from all other zones and is locate ' a zone in which thi in and its u owed Signed I hereby apply for a Certificate of Occupancy r the w in thi ppli on for ermit Signed DO N WRI BELOW THIS LINE -- INSPECTION COMMENTS Inspection / Approval Date By Appl Cod Description Du Whom Cod Comment 95-22714-B 40,000 B01 FOOTING 10/25/95 JFF A B03 FRAMING (ROUGH) 12/01/95 JFF A E03 ROUGH 12/01/95 JFF A P03 ROUGH 12/01/95 JFF A B04 INSULATION 12/04/95 JFH A B10 FINAL 12/22/95 JFH D NO ONE HOME P03 ROUGH 02/20/96 JFH D NO ONE HOME P03 ROUGH 02/20/96 JFH A KITCHEN SINK B10 FINAL 02/20/96 JFH A 95-9356-H 2,500 96-9691-P 500 95-9673-P 900 95-13745-E 900 Total Est Value 44,800 REINO E. HYYPPA 8 ASSOCIATES CIVIL ENGINEERS 8 LAND SURVEYORS GLASTONBURY9 CONK. 1 OV boo P o0 01 h 10, a Q 01 10 1 a QC v J'\ to Al b% 02 P P 00, oli LOT LINES FROM MAP ON FILE TITLEO,OOPEM'SPACE SUBDIVISION A-30 ZONE PLOT FLAN 5FCTICkJ 4 MOUNTAINVIEW ESTATES -%UTH WIND'AfZ,CO JN.~By Re=1No E. HyyppA#AssocIA1ES 5CALE I"=40 OATE: 4-4-84, MAP 1Jn.180-66-1N SHEET 2 OF 1"3 NEETS R ,o- PREPARED FOR. DART HILL REALTY IN(1.jp ZG a•JC (ot..+T o•as W TN CERTIFIED `,J65TANT14LL.`I Wi?RECT SOUTH WINDSOR, CONK. SCALE : 1"%40' OATE: 11-1b-a i i's r AE-, D---PAR'rvIENT TO THE This certified that ti ic: 1.lie true Pies of the proposed builaing ur to 6%erected a V-10 together with amendments stied in applic.1,,fll ,ndfiledwithplanandIagreetocomplywj,,h .,If - rji.ig.Building and state laws and such ord,-rs is ;i,h beissuedbytheBuildingDepartirfnt ,ng pendef,of this application and fi I I of a b ingpermit. Signed This plan is pro ubject to the condition U,at orders and din es regulating building shall bqcompliedwih Conditionally Ap oved These filed wit" ing 1 spc or Clots CERTIFICATION OF ZONING COMPLIANCE Proposed building(s), use(s) and/or structure(s', as shown on this plan appear(s) to be '1-,l conformance with current Sot th Wind regulations. Variances and special exceptioit., may apply. Date CRWg E64rcement. Officer xakI PERMIT DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT 3?4.5' Application is hereby: TOWN OF SOUTH WINDSOR BUILDING INSPECTION DEPT.APPROVED DISAPPROVED4,:1i 1540 SULLIVAN AVENUE 1 UL i 644-2511 Ext. 230 Date g Inspector Application must be printed or typed f 1 . LOCATION OF JOB 1:L a's r s k F 9Rwt AJ. FEE SCHEDULE No . Street 0 - $16000 -10.01i Floor Apt . No. Over $1,000 -l 0.Oe 2. OWNER d per $1,000 Or vNeld M fraction thi reof 3. ADDRESS j r seal91 ORr C`• i 7 t ll4. APPLICANT Rp ,r• SQ.1 tic 61 5. ADDRESS Dj 6ek4i4.« 674 ky, Id d S12 0 (a 01 f1 6. ESTIMATED COSTJoUU 7 . IS THIS A CONTRACT COST Y 8. FEE ENCLOSED $ G 9 E BUILDING:TYPE OF C RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: Original Installation Alteration/Addition/Repair A D 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11 . LOCATION OF JOB NO. STREET APT. NO . 12 . TYPE OF INSTALLATION 13 . SIZE OF MAIN FEEDER y k> 14 . NO . OF LIGHT LOOPS 15. )10. OF HEAT LOOPS_ 16 . NO. OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS 18 . NO . OF HEAT CIRCUITS: 19. -NO. OF POWER OUTLETS 20 . NO. OF CONVENIENCE OUTLETS 21. 'NO. OF HEAT CIRCUITS 22 . NO, OF POWER CIRCUITS 23. NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS_ 26 . NO . OF PANELS 27 . TOTAL WATTAGE 28 . NO. OF POWER FEEDERS 29. NO. OF SWITCHES 30. A/C LOAD 31. SIZE OF POWER FEEDERS 32. NO. OF FIXTURES 33. TOTAL HORSEPOWER 34. NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : p atp ip a ;at/C t> P. RQ*A A gh It LICENSE NO.SIGNATURE OF APPLICANT DATE PHONE NUMBER: (Llo-- 3 132 STATE OF CONNEc-ncu f DEPT.OF CONSUMER PROTECTION BOARD FOR OCCe LIC. GLORIA SCHAFFER This is to certify that under the Nwoviekwo'r of on Gen"Statutes the person a$/ot1 f1j 68. 00as: ELECTRICAL ACTOR--E1u1.tFoNER ocP ROBERT BISAILLON 289 BROONDSOR T SOUTH NI CT06074 ICaN D: EE PAID LIC.NO 125136 $150000 EFFECTIVE EXPIRES 10/01/93 10/01/95 PERMffIT N0. DEPARTMENT DECISION A P P L I C A T I 0 N F O R Application is hereby : PLUMBING PERMIT TOWM OF SOUTH WINDSOR APPROVED DISAPPROVED BUILDING INSPECTION DEPT. lit N 644-2511 Ext. 230 D a e B n s p e c t o r Application must be printed or typed. 1. LOCATION OF JOB: C u FEE SCHEDULE 2. OWNER: 4&101J56A) 0 - $1 ,000 - 10.00 3. ADDRESS: 5j#/; I Over $1 ,000 - 10.00 lper $1 ,000 or 4. APPLICANT:fraction thereof 5. ADDRESS: P YV 6. EST. COST: $ 5-0 O 7. IS THIS A CONTRACT COST? YES X NO 8. FEE ENCLOSED: $ CJ 9. TYPE OF BUILDING: X RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: ORIGINAL ALTERATION INSTALLATION X ADDITION REPAID. BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: GENERA PLUMBING 12. KIND OF INSTALLATION: 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS STYLE 15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS 16A. NO. OF SHOWERS 17. NO. OF LAVATORIES 18. NO. OF SINKS 19. DISPOSAL 19A. DISWASHER 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS SIZE 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS e 32. REMARKS AND FURTHER DETAILS , k 1 GC t J Q i Al, WATER HEATER 33. TYPE 34. MANUFACTURER TANKS SAFETY DEVICES TElfPERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE LBS. 40. MANUFACTURER 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE 38. TYPE 42. MANUFACTURER LICENSE NO. DA2fE SIGN RE PPLICANT PHONE NO. PERMIT NO. q I--k5 DEPARTMENT DECISION APPL ICATION FOR Application is hereby : PLUMBING PERMIT TOWM OF SOUTH WINDSOR 2sPPROVED DISAPPROVED BUILDING INSPECTION DEPT. 644-2511 Ext. 230 Date Building Inspector Application must be printed or typed. 1. LOCATION OF 7,S1,5gill FEE SCHEDULE 2. OWNER: lAofl rQ 3. ADDRESS: 0 - $19000 -10.00 4km Over $1 ,000 - 10.00 per $1 ,000 or 4. APPLICANT: fraction thereof 5. ADDRESS: GX212- 6. EST. COST: $ 7. IS THIS A CONTRACT COST?ES N0 8. FEE ENCLOSED: $ 1)Lf 9. TYPE OF BUILDING: RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: ORIGINAL ALTERATION INSTALLATION ADDITION REPAID. BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: 4 s GENERAL PLUMBING 12. KIND OF INSTALLATION: iIjw-rev"13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS STYLE 15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS 16A. NO. OF SHOWERS 17. NO. OF LAVATORIES 18. NO. OF SINKS 19. DISPOSAL 19A. DISWASHER 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS SIZE 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS 32. REMARKS AND FURTHER DETAILS WATER HEATER 33. TYPE 34. MANUFACTURER TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE LBS. 40. MANUFACTURER 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE 38. TYPE 42. MANUFACTURER LICENSE NO. DATE SIGNATURE OF OPLICANT PHONE NO. 1,).i V 4 I ,f I F;T AW,4, rw Ame 4ll I'C 00 0 IT10H OF BVILDbih---LOU T-7 rA z"Soo Ak ER ADDRESS T" PHM;`NO. 5_aA A HVAC, COYMCTOR" ADWESS TOW 90* TYPE, OF SYSTEM: HEATING Typt OF "BUILDING: RESIDENTIAL A/C COMMOCIAL VENTILATION BUSINESS IF HEATING: STEAK-- LOW_PRESSW, UKT LBS* HIGH PRESSURE LIMIT LBS* A,HYDRONIC WAM, IP, UNIT RADIANT HEATER awmm WOOD COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT L/ ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION ...... DESIGN TEMP. OUTSIDEj-:eQ-OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) IUST ACCOMPANY APPLICATION)HEAT LOSS SHEET I DESCRIBE ALL HEATING, EQUIPMENT (INCLUDING MAKE- & MODEL NO-): x4falz NPUT-IH - 2oloUNTIG (OUPUT-BH) & 000GROSSIT IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE F TOTAL HEAT GAIN (BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN MWAUSE EQUIPMENT) : TOTAL SIZE OF SYSTEM (CFH) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: 2 STATt LICENSE -- NAME & TYPE #DATE LSIGNATUXE OF ?"ANT U., Ift I APPROVED DATE chi ao- I - 8 - R CALCULATION SHEET 1503 (Modern Method)Copyright 1977 by The Hydronics Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE C L A COL.B COL.C COL.D COL.E COL.F COL.G 1 ROOM Q O H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT.U BTUH Ow Foot of 3 LENGTH EXPOSED WALLS.FT. Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA to BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION ROOM LIN. FT.OF ITable 9.Line 3 x H) TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED I Bottom of table used low Line 51 7 CEILING CONSTRUCTION C Table 9,L x W) B FLOOR CONSTRUCTIONt Table 9,L x W r Lin. F t) E 9 COLD PARTITION CONSTRUCTION F Table 9.L K HI G 10 _C 1 Wall(With Openings)O H we 2 Walls(With Openings) X 1 3 Wells(With Openings)or Ent. Hall N J 11 TOTAL BTUH AT 7OF TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K COL.A COLS COL.H COL.i COL. J COL.K COL.L TOTAL BTUH TOTAL OF SUILDING RADIATIONIROOMATSELECTED O H L W H I L W H L W H L W H L W DESIGN TEMP.• 2 ROOM DIMENSIONS.FT U DIFFERENCE 3 LENGTH EXPOSED WALLS, FT. d WINDOW AND OUTSIDE DOOR AREA U. STUN BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9.L1no 3 x HI TOTAL 20% 6 TYPE OF GLASS Bottom 1 table used for Line 51 IFOR CONCRETE FLOOR ON 7 CEILING CONSTRUCTION GROUND OR FILL AT Table 9. L x W) GRADE LEVEL.USE LINEAR 6 FLOOR CONSTRUCTION1 FEET OF EXPOSED EDGE ITable 9.L x W or Lin Ft 1 9 COLD PARTITION CONSTRUCTION ITable 9.L x H) 10 _c 1 Wall(With Openings) 2 Wells(With Openings)p xJ 3 Walls(With Openings)or Ent Hall 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE FORM 1503 This form Is available from The Hydronics Institute 35 Russo Place,BoAsley Heights.N J 07922 B=R CALCULATION SHEET 1502 C pyright 1960 by the Institute of I iler and Radiator Manufacturers OWNER IN rv ADDRESS RA DATE TYPE OF BUILD NG CONSTRUCTION J M 16s DESIGN TEMPERATURE DIFFERENCE I I Roots F. COL. A COL. B COL. C COL. D COL. E COL. IF L H L W H L - W H L W H L W H L W 2 ROOM DIMENSIONS. FT. J 9 O 3 LENGTH EXPOSED WALLS. FT.O ROOMBTUHBTUHBTUHBTUHBTUHTOTALS41GROSSWALLAREA. SQ. FT. REQUIRED REQUIRED REQUIRED REQUIRED REQUIRED FROM LINE 11 5I GLASS AREA. SQ. FT. 41 00 61 NET WALL AREA. SQ. FT. 0 B /71 CEILING AREA, SQ. FT. _1P 81 FLOOR AREA. SQ. FT. t O'C 9 ROOM VOLUME FOR 1 -. cam--- --------------- ------------- INFILTRATION I f .Q 10 TOTAL BTUH AT 70F TEMP. DIFFEREN E Z 1 1 I TOTAL BTUH AT DE IGN TEMP. DIFFERENCE 2 12 HEAT DISTRIBUTING UNITS i G- COL. A COL. G COL. H COL. I COL. J COL.-!So 1 ROOM H H L W H L W H L W H L W H L W 2 ROOM DIMENSIONS. FT.I- 3, LENGTH EXPOSED WALLS. FT. BTUH BTUH BTUH BTUH BTUH 41 GROSS WALL AREA. SQ. FT. REQUIRED REQUIRED REQUIRED REQUIRED REQUIRED J 51 GLASS AREA. SO. FT. 61 NET WALL AREA. SO. FT. N K 0% Ole 71 CEILING AREA. SO. FT. b¢81 FLOOR AREA. SQ. FT. t 1. 9 ROOM VOLUME FOR U TOTAL BTUHI - INFILTRATION OF BUILDING ATI CU. FT. DESIGN TEMP. DIFFERENCE 10 TOTAL BTUH AT 70F TEMP. DIFFERENCE` 1 1 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE 12 HEAT DISTRIBUTING UNITS INCREASE BATHROOM TOTAL 20% tFOR CONCRETE FLOOR ON GROUND OR FILL AT GRADE LEVEL. USE LINEAR FEET OF EXPOSED EDGE This f rm is available from Th Hydronics Institute (Formerly The Institute f B filer and Radiat r Manufacturers) 35 Russo Place, Berkeley Heights, N.J.07922 FORM In 2 E S T I MATE QUANTITY ITEM AMOUNT Boiler No. Net I B-R Rating or Net SBI Rating* Oil or Gas Burner or Stoker, with Controls Oil Tank, Pipe and Fittings Combustion Chamber or Stoker Hearth Pump Thermostat Low Limit Control Reverse Control Extra Controls Draft Regulator Flow Control Valve Pressure Reducing Valve Relief Valve Air Cushion Tank Domestic Water Heater and Tank Mixing Valve Pipe, Valves, Fittings, Hangers Pipe Covering Heating Units (Radiators, Baseboards, Convectors) Radiator Enclosures Sets — Radiator Brackets Radiator Valves Radiator Union Elbows Radiator Air Valves Main Air Vents Floor and Ceiling Plates Smoke Pipe Foundation Electric Wiring Pounds — Asbestos Cement Paint Freight and Cartage Labor Incidentals Total Cost Overhead Profit Bid Net I=B=R Rating or Net SBI Rating of Boiler should equal or exceed the total heat loss of the house plus proper allowance f r domestic hot water