Loading...
HomeMy WebLinkAbout21 Dawn Drive (3)7ApplicatioRTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# y: TOWN OF SOUTH WINDSOR NO yBUILDINGDEPARTMENT r APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 i Date B i ing Inspector Application must be printed or typed Location of Job- FEE SCHEDULEE P+W$ 0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= 15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. r 3 APPLICANT APPLICANT ADDRESS APPLICANT PHONE# OWNER SOW N SFq p, OWNER ADDRESS w OWNER PHONE Cc) ESTIMATED COST$ IS THIS A CONTRACT COST? Yes No FEE ENCLOSED$ TYPE OF JOB• SOR-C ew Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF B G: HWING SIDENTIAL a<c COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL OIL-GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFO NCE OF SUCH WORK. CONTRACTORS LIC -NIOL, TYPE E SIGNATURE OF APPLICANT DA 5 ST 02/06/2003 14:48 8606233148 LITCO EW RIGHT-J SHORE' FORM Entire House Your Company Name Your ConWWy Addle",YourGlty,ST90OW)M Phone:M-5W1212 Fmc WW566.2121 Project Information Design Information H1t9 CI0 Inflltratlon Outside db(OF)17 91 Method Simplified Inside db(OF) 70 75 Construction quality Average Design TD(°F)53 15 Fireplaces 0 Daily range M Inside hum,d4(°16) 50 MoWture difference(96Ib) - 35 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Efficiency 80.0 AFUE Efficiency 0.0 EER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Stuh Lated cooling 0 Btuh Heating temperature rise 0 °F Total cooling 0 Btuh Actual heating fan 1921 cfm Actual cooling fan 1921 Cfm Heating air flow factor 0.028 cf n/Btuh Cooling air flow factor 0.048 cfm/Btuh Space thermostat Load Sensible heat ratio 84 % ROOM NAME Area Htg bad Cig bad Htg AVF Glp AVF ft Stuh) Btuh) cfm) cfm) KITCHEN 120 2282 2770 64 133 DINNING ROOM 168 4864 2882 136 138 LIVING ROOM 308 7040 2825 197 136 FOYER 100 2933 1312 82 63 OFFICE 240 6281 3492 175 167 NEW ROOM 672 14043 8683 392 415 MUD ROOM 200 7171 4782 200 229 JUSTIMS ROOM 132 2591 1075 72 61 MICHAELS ROOM 154 4013 2265 112 1.08 MASTER BEDROOM 532 11687 6153 326 294 MASTER.CLOSET 150 3037 1284 85 61 BATH 50 2831 2622 79 125 Printout certified by ACCA to most all requiremerb of Manual J 7th Ed_ 1/1/r 1 7t I RVA-Suifa ReWdd(rtMl'm S.d.30 RSR30338 2003f ob-06 10,41:31 pap 1 AADON gOLjCHARD-MOWARD MALE-eir 02/06/2003 14:48 8606233148 LITCO EW PAGE 02 Entire House d 2726 68772 40146 1921 1921 Ventilation air 0 0 Equip. Q 0.96 RSM 88640 Latent cooling 7706 TOTALS 1 2726 68772 46245 1921 1921 Printout c ertll`W by ACGA to meet all regclirements of Manual J 7th Ed. WrightSCYft RW-Suite I @BMAWTM 5,0.30 RSR303M 2003-F*461041:31 AVON ebucrARo.HOWARn HALE.nw Pepe 2