Loading...
HomeMy WebLinkAbout21 Berle Road (11)FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: ( 0 1.74Pr NO. TOWN OF SOUTH WINDSOR EST.COST: 9C BLDG. PERMIT NO. 1540 SULLIVAN AVENUE FEE SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 0 - $19000 - $10.00 1000 or fraction LOCATION OF BUILDING C thereof - $10.00 XWX 5 OWNER ADDRESS TOWN PHONE NO. HVAC CONTRACTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW WOOD COAL / OIL TANK - SIZE & LOCATION: INSIDE 'j/OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) 4 HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN (BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT) : TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: STATE LICENSE - NAME & TtPE #DATE SIG ATUR OF APPLICANT dIAr_ APPROVED IJATt BD 4A 11/88 I a B - R CALCULATION SHEET 1503 (Mod rn Method) Copyright 1977 by The Hydronlcs Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL A COL.B COL.C COL.D COL.E COL.F COL.G 1 ROOM O H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT.U BTUH per Foot of 3 LENGTH EXPOSED WALLS, FT. Q Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION ROOM LIN.FT.OF Table 9, Line 3 x H)TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED Bottom f table used f r Line 5) 7 CEILING CONSTRUCTION C Table 9.L x W) g FLOOR CONSTRUCTIONt D- Table 9, L x W or Lin. F t) E 9 COLD PARTITION CONSTRUCTION F Table 9, L x H) G 10 _c 1 Wall(With Openings)G H Z Walls(With Openings) D X 3 Wells(With Openings) or Ent.Hall J 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K COL.A - --_ _-- COL.B COL.H COL.1 COL_J COL.K COL.L TOTAL BTUH TOTAL OF BUILDING RADIATION1ROOM AT SELECTED O H L W H L W H L W H L W H L W DESIGN TEMP.- 2 ROOM DIMENSIONS, FT f 1 DIFFERENCE U 3 LENGTH EXPOSED WALLS, FT Q 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9, LIns 3 x H) TOTAL 20% 6 TYPE OF GLASS Bottom f table used for Line 5) 7 CEILING CONSTRUCTION tFOR CONCRETE FLOOR ON GROUND OR FILL ATTable9, L x W)GRADE LEVEL,USE LINEAR B FLOOR CONSTRUCTIONI FEET OF EXPOSED EDGE Table 9, L x W or Lin Ft) 9 COLD PARTITION CONSTRUCTION Table 9, L x H) 10 r_ 1 Wall(With Openings) 0 c Z 2 Walls(With Openings) o J 3 Walls(With Openings) r Ent Hall fe. 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE This form Is available from The Hydronics Institute.36 Russo Place,Berkeley Heights,N J 07922 FORM 1503