HomeMy WebLinkAbout207 Lisa Driver r To THE BUILDING INSPECTOR 4 the APPLICATION FOR TOWN OF SOLI WINDSM Cam. PLAN EXAMINATION AND BUILDING PERMIT IMPORTANT — Applicant to complete all items in sections: 1, 11, 111, IV, and It O I ZONING A-30AT (LOCATION) DISTRICT LOCATION STREET) OF BETWEEN 1 AND BUI LDING CROSS STREET) CROSS STREET) SUBDIVISION MOUNTAINVIEW ESTATES LOTS—BLOCK LOT E II. TYPE AND COST OF BUILDING — All applicants complete Parts A —'D oA. TYPE OF IMPROVEMENT D. PROPOSED USE — For"Wrecking"most recent use m M 1 New building Reside tial Nonresidential2 Addition(1/residential, enter number 12 FOne family 18 Amusement, recreationalGotnewhousingunitsadded, i/any, is Part D. 13) 13 Two or more family — Enter 19 Church, other religious 3 Alteroti n (See 2 above) number o/units— ——-.p. 20 Industrial 4 Repair, replacement 14 E]Transient hotel,motel, 21 Parking garageordormitory — Enter number 5 Wrecking (1/multi/amity residential, o/units ——————— —-..`. 22 Service station, repair garage enter number o/units in building in 15 Garage 23 Hospital, InstitutionalPartrtD. 13) 6 M (relocation) 16 Carport 24 Office, bank, professional 7 Foundation only 17 Other — Speci/y 25 E] Publicutility 26 School, library, other educati nel B. OWNERSHIP 27 Stores, mercantile 8 FE Private (individual, corporation, 4 28 Tanks, towers n npr fit institution, etc.) 29 Other — Speci/y9 Public(Federal, State, or I cal government) IC. COST Omit cents) Nonresidential — Describe in detail proposed use of buildings,e.g.,f d rr processing plant, machine shop, laundry building of hospital,elementary10. C at f improvement,,,,,,,,,,,,,,,, d I i7o school, secondary school, college, parochial school, parking garage for,department store, rental office building, office building Gt industrial plant.To be installed but not included If use of existing building Is being changed,enter proposed usesintheabovecost a. Electrical...................... b. Plumbing ....................... or.Heating, air conditioning......... d. Other(elevator, etc.)............ 11. TOTAL COST OF'IMPROVEMENT S 111. SELECTED CHARACTERISTICS OF BUILDING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS 30 n Mes my(wall bearing) 40 0 Public or private company 413• Number of stories................ 31 p Wood frame 41 Private (septic tank,etc.) 49• Total square feet of floor ores, 32 CD StfYCtY/a) steel all floors, based on exterior 33 Reinforced concrete H. TYPE OF WATER SUPPLY dimensions ......... •.•.... 34 Other — Speci/y 42 00 Public or privets company 50• Total land Great sq. It. .:......... 43 Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES F. PRINCIPAL TYPE OF HEATING FUEL 1. TYPE OF MECHANICAL 51. Enclosed....................... 35 Gos Will there be central sir 52. oYtdoofs•.••..........•.•...,.,• 36 011 conditioning? L. RESIDENTIAL BUILDINGS ONLY37 El ctricity 44 Yee 45 N 53. Number f bedroam&..............38 C of 39 Other— Speci/y Will there be an (evetorT Full..........54. Number of 46 Y • 47 1!qo bethreems Partial........ / L IV. IDENTIFICATION — To be completed by all applicants Name Mailing eddr ss — Number. street. city. and State ZIP code Tel. No. Owner or Dart Fill Realt Inc. 658 Ellington RoadO e&see South W 2. Same Contractor 3. Architect or Engineer The owner of this building and the undersigned agree to conform to all applicable laws of this jurisdiction. Signature of applicant A44ress Application date DO NOT WRITE BELOW THIS LINE V. PLAN REVIEW RECORD — For office use Plops Review Required Check Plan FRe y view Date Plans B Date Plans By NotesStartedApproved BUILDING PLUMBING MECHANICAL ELECTRICAL OTHER r VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Permit r Appr val Check Ob Date toined Number By Permit or Approval Chec Ob Date ned Number By BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SE ER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER YII. VALIDATION Building 1 5754"Permit number Bui(ding Permit issu d b 19 Building Permit Fe $ J. od A rov 11TLE TOWN OF SOUTH WINDSOR BUILDING PERMIT Date Juen 10 1987 Fee Paid $5.22.00 Est. Value $.87.,000,00 Permit N° 15955 on the side of T nt 469 Li gee Drive Street Street No. - Owner rt ui 1 1 RT?gli-y Applicant same -Qs. ybwtro CERTIFICATE OF OCCUPANCY ISSUED: Date No. 8205 Fee Paid $ 3.00 CLASSIFICATION dwelling BUIIDING PERMIT N° 15955 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn. J11102 1 D 19 87 94is is to Certif3, That is hereby granted permission to build at estimated value of on the side of- At J169 Li Street on land owned by Dirt N311 8salty-- Said irk to be as described in Application No. 1 67A6 and to conform to specifications and plans filed with said Application, and Building By- laws of THE TOWN OF SOUTH WINDSOR. l.u& AJ=e 19 87 T3 U" Building Inspector. Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compelled to reason therefor." wttI$7 c C 06,071.;sq (r:A-e-- Z- tAW Inc_ Permit 059 SS Electrician -?)Gh A RO ZArne-9 7YY L-'- Heating Contr. L W,A(D bi, ?1U.6;11 # - F-5-6 Plumbing " PRL Z E MF Mbyt(2 # '7310 Oil Burner Certificate of Occupancy Taa y Sewer Permit 191V7 ro/o r7 Tet--O`Q10'b(zI INSPECTION REPORT Permit # Job ;t%U.. Mt 1 Footing 2 Foundation 3 Framing 4 Wiring q 5 Plumbing L C o 6 Heating Ehing. 'jaQ$ LA-V P rmit No. = TOWN OF SOUTH WINDSOR SOUTH WINDSOR, CONN. Permit 8205 Certificate of Occupancy THIS IS TO CERTIFY that the I 0 t., at No. £Z A, 2 in the Town of S th Windsor, Connecticut, has been erected and completed in accordance with he Builftg Code and Zoning Regulations of the Town of South Windsor, and is hereby approved f4 occupancy. C Bui lduig nspector Owner, Builder Fee Paid Date 19 CERTIFICATE OF OCCUPANCY CHECK LIST 2- i Certificate of OccupancyApplicant Address Lisp Bldg. Permit No. Lot No. 9 Date Submitted 2 Project ri,o%"Reviewed By Date As required in the Zoning Regulations, no certificate-of-occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall inlcude: Approved Denied N/A 1. Approved building permit plan. 2. Finish grading per approved building permit plan. 3 . Site work; i.e. trees, shrubs, dumpster: required parking 4 . Utility location a. sanitary sewer b. foundation drain c. electrical & telephone d. water e. other 5 . Appropriate certification 6 . Bonding Sewer Permit No. Pavement Excay . No. COMMENTS : RENO E. WYRPlA & AM-CIATES CIM EN LAND SURWYORS GLASTONOM, CONK 3AZ o LISA T)RI E e a 3'36•a 34 w O s 1 342 4- A.+ ZI. 24 u N 'TF• 34v, l Li t O - V 1 tY In CQ O 342 AREA= z0000 s.F oo-oo' N bw oe n 34Z oT UMCS FRO A MAP OW FILE TITLF-0, mow SwVcE suw\ilslow A-30 Zom PLAN RAW SEJGTIO.! 3 MOL*4TI*MrzW tool.""pm i AS:moves SCALE i" DAM:&25-85Mw No.180*8'5-1L bkwr-s of a 514tErs wv. PREPARED FOR fUm. 5 a -1-1-8-1 v, ,1o , D 4 RT HILL REALTY INC CERTIFIED ciiWUNTIAL.L`1 cJVRECT SOUTH WINDSOR, OONN, 5CALIE. I"-40' prATE: 4-3O-a? AP' PROVED Y E' _ _ r'. NT CAS.. BUILDING PERMIT CHECK LIST Applicant Building Permit No. Address ?io-7 G/S/ Date Submitted d Reviewed byLotNo. Project Date In acc ordance with the Subdivision Regulations , prior to the building of any structure on a -lot, a Topographic Plot Plan shall be submitted o r approval. The minimum requirements shall include : Approved Denied N/A 4 t/. 1. Name , address & phone number of owner/ applicant. j. 2 ,- 3/r 2. Name, address & phone number of plan re arer. 3. Zoning information - i.e. zone, en space., fl oodway, etc. 4 . Plot plan at 1" = 40 ' scale. a. Subdivision reference, abutting properties , etc. b. Easements of record. c. Lot description, bearings , distances , building lines , area, etc. r/ do Contours , existing & proposed, 1 or 2 ft; interval where appropriate. e. Building location with dimensions . Elevations of proposed finish floor, garage f1bor & center line of road at driveway. V- Z f. Elevations of gravity drainage systems , sanitary & foundation drain at the house and the street. g. Tentative utility location gas , electric water, etc. v h. Title block with name and address of preparer, date appropriate certification live seal and signature. 5 . Sedimentation and erosion control. 6 . Special Planning & Zoning, Inland/Wetlands considerations . (Plans on file w/Town Clerk) , BUILDING DEPT.57/iz P ZC 7-hi 7V IWA/CC WPCA 2`' OTHERS COMMENT S: Permit # 9788 ELECTRICAL APPLICATION Application No. 1 1 2 9 4 on the side of Loott O_ StMt Street No. 207 Lisa Drive Owner JMJ Construction Co. Electrician Richard Barrett FILED IN OFFICE OF The Building Inspector 7/16 19 87 INS P1=10N. r$No Electrical Work shall be started until a Per- mit is granted by the Building Inspector. in New Buildings no wiring shall be started until the plumbing and heating pipes, and the ere stops (if of wood) are installed. without a special permit from the office of the Building Inspector. Electrical Permit No. 7 Master License No. QA7 .... TOWN OF SOUTH WINDSOR Building Per No. .......... ........ ....................... BUILDING DEPARTMENT Date Filed ....... 1................................... Date Final Approval ...................._.......................... APPLICATION FOR ELECTRICAL WORK Electrical Inspector JOBLOCATION: JOB OWNER: .. ...................................................................................................... Side of . Between and ......... ...... .... Name of Building Owner a .. C-t`,t Address . . If work is for Lessee--Give name . .. . Address .......... .. ....... ....._......................................................... Building now occupied as (unless new) No. of family units now .... "' ............ Building to be occupied as ....... .. .. is5.`u-.e Number of family units to be ....... , ................. Is this work included ' a Building Per it?Permit Fee a... .l If no Building Per ) Permittee \V. Business Address .. ..1 ..C C.....1,,;, Telephone Kam..( ..... COSTOF INSTALLATION: ... 6............................... ... ............................ ......................................................................................................................... TO BE FILLED OUT BY PERMITTEE TO BE WIRED EXISTING APPLIANCES Number of light outlets to be installed . . . - Number of convenience outlets to be installed - Number of present Appliance Circuits ................................................ Number of switches to be installed Do these include Range Water Heater Number of appliances to be installed as listed below) Dryer Air Conditioner Oil Burner TYPE RATING NO. Dish Washer Gas Burner Range Well Pump Elec. Heaters Range Top . . . . . . Oven . . . . . . . .REMARKS: Water Heater Clothes Washer . . . . U) O rlt Q S Qt Clothes Dryer . . . . . 9 jIYFC Dish Washer . . . . . . l Air Conditioning Motor . Oil Burner Motor . . . . Gas Burner . . . . . . Circulator Motor . . . . Attic or Large Fan , , , Well Pump . . . . . . Electric Heat . . . . . Other . . . . . . . Number of new Lighting Circuits . . . . ..... . Number of new Appliance Circuits . . . .......... Number of Heating Circuits . . . . . . ....... ..-................. Number of Motor Circuits . . . . . . . Size of present service Size of service to be .................... Permit # 7390 PLUMBING APPLICATION 7058 on the ..... sick a Lot # 69 4;l Street N _j Drive Owner Dart Hill Realty Inc. ply _Carl Zettlemoyer Filed in Office of The Bui ift Lrpecoor 7/16 1987 No pawn shall constro cy add to or aber ay portion of the drainage system of any bog mcept to repair leaks) until a Permit is scanned by the Building Inspector. APPLICATION FOR PLUMBING PERMIT (Continued fr m Reverse Side) TOWN OF SOUTH WINDSOR, CONN. 11. LOCATION OF JOB Lot #69 Lisa Drive A94 NO. STREET FLOOR APTAO. GENERAL PLUMBING 12. KIND OF INSTALLATION Residential 13. SIZE OF MAIN DRAIN 4" 14. NO. OF TOILETS 2 STYLE tank 15. NO. OF URINALS 0 STYLE 16. NO.OF BATHTUBS 1 17.NO.OF LAVATORIES 2 18. NO.OF SINKS 1 19. NO. OF WASHTUBS_ 0 20. NO.OF CONDUCTORS SIZE 21. NO. OF STACKS 1 SIZE 3" 22. AREA OF ROOF 23.NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES One KIND 4' one piece shower stall 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? yes 27. SIZE OF WINDOW ? 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? electric vent fan 29. SIZE OF DUCTS 3" 30. ARE SEWAGE AND WATER FACILITIES AVAILABLE? yes SIGNATURE ADDRESS 52 Connecticut Avenues LICENSE NO. 203068 ESTIMATED COST 4r7c'0, 0 0 TELEPHONE 528-4413 OWNER Dart Hill Realty Inc. ADDRESS 658 Ellington Road, South windsor WATER HEATER 31. TYPE gas fired 32. MANUFACTURER A. O. Smith TANK SAFETY DEVICES 33. CAPACITY 40 gallons 37. TEMPERATURE RELIEF VALVE 210 34. TEST PRESSURE 150 38. MANUFACTURER_Watts 35. WORKING PRESSURE 80 39. PRESSURE RELIEF VALVE 150 36. TYPE glass lined 40. MANUFACTURER Watts ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE OWNER OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. 4!Z 2 CD962 ATE IG TU OF A&9CICANT PERMIT # Application For 3' DEPARTMENT DECISION Heating Permit AitEAPPLICATIONISHERESY: DEPARTNUff OF LICENSES AND INSPEMONS DISAPPROVEDOAPPROVED TOWN OF SOUTH WIN DSOR A kk DATE CNitI MISrECTON AP LICATIOtts MUST •E PRNITED ON TT10ED. NA IN wall NUM/EN ONE 11ELOW 14*9 r' E t. LOCATION OF JOR Lisa Drive Mo.tiTNEET 69 A LOT NO. FLOOR N s. OWNER Dart Hill Realty inc. ADDRESS 658 Ellington Road South Windsor s. 282-0628 rIIONE B. APPLICANT South Windsor Plurnbing ADDRESS 52 Connecticut Avenue South Windsor E528-4413s.PHON 307190 D. LICENSE NO. CL B EXPIRATION DATE OF LICENSE 10/1/87w 5r t0. ESTIMATED COST f Iq S 0 THIS A CONTRACT COST? YES 0 NO a t!. FEE ENCLOSED f so. TYPE OF NINLOINO: COMMERCIAL 0 414. TYPE F JOB: INDUSTRIAL x ORIGMAL ON MISTAAL ATION ADDITION eErA!!! APPLICATION FOR HEATING PERMIT illy Rerene ) 11. LOCATION OF J B Lot #69 Lisa Drive N STREET LOOK AST.NO. IL TYPE OF INSTALLATION: OIL BURNER ELECTRIC VENTILATION SPRINKLER WGAS BURNER STACK INCINERATOR MISCELLANEOUS f /_%/I - T to SIZE LOCATION SIZE SIZE 13. OF TANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER T_FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. 600'-('1G1? B.T.U. OR SO. FT. NEef_ 'v B.T.U. OR SQ. FT. GROSS FIRING RATE FLOORS TO BE HEATED NEW 9R OLD BUILDING L'LLO INSULATED - YES OR NO TYPE OF WALL Ll10:a .l.i c . INSULATION ` '-L,_ROOF OR CEILING ' INSULATION AVG. SYSTEM WATER TEMP._&I` B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMP RATURE DIFFERENCES FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COP ER CONVECTORS. OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U. DESCRIPTION OF WORK AICi1S. TO BE DON T ZV xy t loor HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS): CON SIZE AMO DOOws AREA — SQUARE FEET !•T•U. ILT•L CI. DISTRIBUTION INSTALLED TOTAL TOTAL j a ROOM wo• 3 *wOY *LAY NKT MALL CIDLIN* PUXM CU. AT. 7M F TV t AMC/1!t wAO. Ow LtAOtwLANAND ALL t IINIILT.) TEMP. TO • r, j so FT12tOIII. orM•x Rwtt AwtA TOTALS A. HEAT LOSS FROM BUILDING B.T.U./HR. S. DOMESTIC HOT WATER DEMAND f ti fl©• B.T.U./HR. C. PIPING. OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY-- •'{, 51'ez i 4_ ( Je MANE AOOREii SUBCONTRACTORS AND 1s. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE(OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. oe PPLICATION TO BE COMPLETELY FILLED IN. 7 I = B= R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The Hydronics Institute i ANER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE ` b COL.A COL.8 COL.C COL.D COL.E COL.F COL.G 1 ROOM cJ//Y&- 011VI Vir R ok`/TtHE/V L R U 04-^/ P'0 O H L W H L W H L W H L W H I L W Design Water Temp. 2 ROOM DIMENSIONS,FT. p 61 I/a Z 1 3 F. ev, 6 Ad' 3.BTUHUr74JRadiation Selected r J4 Foot f 3 LENGTH EXPOSED WALLS,FT.Q pZ 4 WINDOW AND OUTSIDE DOOR AREA LL 3 3 BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION Table 9, Line 3 x H) Q ROOM LIN.FT.OF3000d0/ 4#047 TOTALS RADIATION 6 TYPE OF GLASS X1 // FROM LINE 12 SELECTED mBtto of table used for Line 5) 30 O 1,300 ovw0 O p / 7 CEILING CONSTRUCTION C G V /pZ E70 Table 9, L x W) OG D 1.3Io G ., 8 FLOOR CONSTRUCTIONt LA/1-1 y Table 9, L x W or Lin. Ft.) OS 94 V V a0 0 TJ0VE -Q 9 COLD PARTITION CONSTRUCTION p 000 G /' f 7 3 d E Table 9, L x H) 0 I- 10 _C 1 Wall(With Openings) Z H e3aQ0 2 Walls(With Openings)X 0/' oZ O(J 3 v TO I 3 Walls(With Openings)or Ent.Hall H doZ7 11 TOTAL BTUH AT 70F TEMP.DIFFERENCE 460600 fG O 3b''OCJ 00 DO J 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE X. 4170 fJ 300 1 /SQ0 1 lqlo COL.A COL.B COL.H COL.I i w ", TOTAL BTUH TOTAL 1 ROOM Y Q ftTf Fjcpu- Q A;W/'7A F BUILDING RADIATION AT SELECTED O H L W H L W H L W H L W H L W DESIGN TEMP.° 2 ROOM DIMENSIONS,FT. U Q 116. F DIFFERENCE y3LENGTHEXPOSEDWALLS,FT.Q 4 WINDOW AND OUTSIDE DOOR AREA LL p'L 02 BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9,Line 3 x H) 07 30G 300 00 0 G 4/6 O TOTAL 20% 6 TYPE OF GLASS( B ttom of table used for Line 5) X 300 ae 0 4 pO O e Q o Opt 0 O t7CEILINGCONSTRUCTION FOR CONCRETE FLOOR ON GROUNOR FILL AT Table 9,L x W) G O?0 0 700 71 0 O O GRADEDLEVEL,USE LINEAR g FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE Table 9, L x W r Lin.Ft.) Q s 40O O 9 COLD PARTITION CONSTRUCTION Table 9,L x H) 10 :a 1 Wall(With Openings) 03k4:%z c a 2 Walls(With Openings) 2 X p 0 0 G O 03Walls(With Openings)or Ent.Hall H le"d 0 11 TOTAL BTUH AT 70F TEMP.DIFFERENCE' 0?8'O0 0 a2 a ce d p O 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE 340Q 0 O 1 376-F O' /,SO O FORM 1503 This form is available from The Hydr nics Institute,35 Russo Place,Berkeley Heights,N.J.07922 B= R CALCULATION SHEET 1503 (Modern Method) zIll Copyright 1977 by The Hydronics Institute OINER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE / 6 COL.A COL.B I COL.C COL.D COL.E COL.F COL.G tT1ROOM C f 2 Design Water Temp. o O O H L W H L W H L W H L W H L W 2 ROOM DIMENSIONS,FT. f BTUH per Foot fUQ 3 LENGTH EXPOSED WALLS,FT.Q aroe Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA LL 10 BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION ROOM LIN.FT.OF Table 9,Line 3 x H) 1,07 6 ! 6 O TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED Bottom f table used for Line 5) xi /l0IJ n O7CEILINGCONSTRUCTIONCt/ Table 9,L x W) G v I D g FLOOR CONSTRUCTIONt Table 9,L x W r Lin.Ft.) Qs E 9 COLD PARTITION CONSTRUCTION F Tabl 9,L x H)G 10 _C 1 Wall(With Openings) m3 H c- 2 Walls(With Openings) Dx 0?0100 1e3Walls(With Openings)or Ent.Hall F. ovt7 J 11 TOTAL BTUH AT 70F TEMP.DIFFERENCE' 1.6-00 Q K 12 TOTAL BTUH AT DESIGN TEMP.DIFFERENCE L I COL.A COL.B COL.H COL.I COL.J COL.K COL.L TOTAL BTUH TOTAL OF BUILDING RADIATION 1 ROOM AT SELECTED O H L W H L W H L W H L W H L W DESIGN TEMP.° DIFFERENCE 2 ROOM DIMENSIONS,FT. 1 U 3 LENGTH EXPOSED WALLS,FT.Q 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9,Line 3 x H) TOTAL 20% 6 TYPE OF GLASS Bottom of table used for Line 5) tFOR CONCRETE 7 CEILING CONSTRUCTION GROUND OR ILL AT ON Table 9,L x W) GRADE LEVEL,USE LINEAR g FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE Table 9,L x W or Lin.Ft.) 9 COLD PARTITION CONSTRUCTION Table 9,L x H) 10 c 1 Wan(With Openings)C3 2 Walls(With Openings) 1 x 3 Wells(With Openings)or Ent.Hall J 11 TOTAL BTUH AT 70F TEMP.DIFFERENCE- 12 1 TOTAL BTUH AT DESIGN TEMP.DIFFERENCE X1 FORM 1503 This f rm is available from The Hydr nics Institute,35 Russo Place,Berkeley Heights,N.J.07922 lo APPLICATION FOR BUILDING PERMIT Electric# 207 LISA DRIVE Plumbing#Date: HVAC # 1 6• 22404 SS Sprinkler# FINAL AP R VAL Estimated Cost $60 Building / 5 COMPLETE RED BOXED AREAS Permit Fee d Engineering TYPE OR PRINT ONLY Occupancy Fee $ Affidavit SIGN ON REVERSE SIDE Appr.for CO. Total Fee 1 TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR,CT Additional Cost) $ Th undersigned hereby applies to do work according to the following specifications: Job Location Lot No. Side of Street Zone Applicant Tel.#jz—D?1 2: Address ao_? L4 501 Zip p Lic. # Owner Pdun,,_y ' Address r2O? Q Ski- NFL Architect Address Sq. Ft. New Area: 1st FI. 2nd FI. 3rd FI. Total New Area Rooms Lavatories Bathrooms Garages Purpose of this permit:61.e A L011-/Lt City Water 0 Well 0 Septic System Sewer C Use Group ^•/1,4 Construction Type Area Basement Garage Approved by Date 6IPA Revised 6/95 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone in which this building and its use is allowed. Signeds, --:::> 1 hereby apply for a Certificate of Occupancy for the work described in this application for the permit Signed DO NOT WRITE BELOW THIS LINE -- INSPECTION COMMENTS Inspection / Approval Date By Appl Code Description Due Whom Code Comment 95-22404-B 2,500 BO1 FOOTING 07/06/95 JFH A BO1 FOOTING 07/06/95 JFH A B10 FINAL 09/12/95 JFF A APPROVED FOR CLOSEOUT