Loading...
HomeMy WebLinkAbout2063 John Fitch Boulevardf DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WIlVDSOR PERMIT# Application is hereby: 116BUILDINGDEPARTMENT 1540 SULLIVAN AVENUE Bldg.Permit# 4/D4 644-2511 ext. 230 Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: 0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= 15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS APPLICANT PHONE# N OWNEROWSFqOWNER ADDRESS c n. 07 O OWNER PHONE C ESTIMATED COST$1/ 7 A%W IS THIS A CONTRACT COST? j-4es No FEE ENCLOSED$ TYPE OF JOB: oOR-C ewnstallation Alteration/Addition/Repair i Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SWTEM: TYPE OF B13 G: AEMEATING SIDENTIAL A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE 7c OF DIFFERENCE '70 F TOTAL HEAT LOSS(BTUH)(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) C'*,!rT RATING(OUTPUT—BT TYPE OF FUEL OIL—GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY Q-(jAS—INPUT aPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK y' THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CON C ORS LICENSE NO. TATE SIGNATURE OF APPLICANT DATE TR1160 RIGHT-J SHORT FORM 9-16-02 Job # :Htg Clg For: Paul Tellier Outside db 0 90 2o6 Q.0 4.a. John Fitch Blvd. Inside db 70 75 S . Windsor CT Design TD 70 15 Daily Range M Inside Humid. - 50 By: CENTRAL HEATING COMPANY Grains Water - 35 Const . Quality a of Fireplaces 0 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Model Model Type Type Efficiency / HSPF 0 . 0 COP/EER/SEER 0 . 0 Heating Input 0 Btuh Sensible Cooling 0 Btuh Heating Output 0 Btuh Latent Cooling 0 Btuh Heating Temp Rise 0 Deg F Total Cooling 0 Deg F Actual Heating Fan 1805 CFM Actual Cooling Fan 1805 CFM Htg Air Flow Factor 0 . 034 CFM/Btuh Clg Air Flow Factor 0 . 053 CFM/Btuh Space Thermostat Load Sensible Heat Ratio 90 ROOM NAME AREA HTG CLG HTG CLG SQ. FT. BTUH BTUH CFM CFM old part 1225 42460 29897 1443 1599 addition 340 4548 1613 155 86 OTHER ADDITION 520 6114 2243 208 120 Entire House 2085 53121 33753 1805 1805 Ventilation Air 0 0 Latent Cooling 3572 TOTALS 2085 53121 37325 1805 1805