Loading...
HomeMy WebLinkAbout203 Kebalo Lane (4)DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT y(/ APPROVED 1540 SULLIVAN AVENUE Bldg.Permit#644-2511 ext. 230 3 7 Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: 2D r,4AA-LD U K tT 2s:3 J0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= WVAEe s 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT_ a oe:n rCect= I APPLICANT ADDRESS L 7F--A- 75C j p APPLICANT PHONE# OW N S F OWNER 1 LI—C OWNER ADDRESS E. OWNER PHONE (Q L47S - W 4 L40 C a ESTIMATED COST$ 7190U IS THIS A CONTRACT COST? /*PYes 0 No Q 46) FEE ENCLOSED$1 SpR. TYPE OF JOB:CO ew Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: OATING RESIDENTIAL COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW P SSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC ARM AIR UNIT RADIANT HEATER EXISTING RADIATIO ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) D_11 rA-t' un c:C R nos ry i IV Icci q nj cn I A ice m in GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT-BTUH) TYPE OF FUEL OIL-GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) cQfatrai -n [c, mp- TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE w. RIGHT-J SHORT FORM Entire House Fahrenh it Mechanical Services Job: 09-17-2001 7 Moody Road,Enfi Id,CT Phone:1-860-763-5775 Fax:1-860-763-5844 Project For: Wheeler Sr. Res. "D"Unit Kebalo Lane, South Windsor, CT Design Information Htg Clg Infiltration Outside db (OF)5 97 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F)75 22 Fireplaces 0 Daily range M Inside humidity(%) 50 Moisture difference(gr/lb) - 37 HEATING EQUIPMENT COOLING EQUIPMENT Make RHEEM AIR CON Make RHEEM MANUFAC Trade Rheem Trade Rheem RAKA Series RGRA-04(E,N)MAES RAKA-030JA RCBA-3765 Efficiency 93.5 AFUE Efficiency 10.0 SEER Heating input 45000 Btuh Sensible cooling 19740 Btuh Heating output 42000 Btuh Latent cooling 8460 Btuh Heating temperature rise 38 OF Total cooling 28200 Btuh Actual heating fan 1004 cfm Actual cooling fan 1004 cfm Heating air flow factor 0.031 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh Space thermostat Load sensible heat ratio 86 % ROOM NAME Area Htg load Clg load Htg AVF Clg AVF ft2) Btuh) Btuh) cfm) cfm) Foyer 85 3955 934 121 50 Bath 72 140 1200 4 64 Living Room 324 9061 7088 277 379 Master Bedroom 195 4878 2751 149 147 Master Bath 110 2221 695 68 37 Master W. I. C. 36 399 136 12 7 Dining Room 127 3041 514 93 27 Kitchen 114 3988 2954 122 158 Bedroom/Loft 216 4687 2280 143 122 Bath (Optional) 82 509 229 16 12 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. t wnghtSOft Right-Suite Residential-5.0.28 RSR25708 2001-Sep-17 20:14:29 ACC, C:1Fahmeawheeler Sr.Res.D-Unit.rsr Page 1 Entire House p 1361 32879 18780- 1-004— - ----------1004- Ventilation air 0 0 Equip. @ 1.02 RSM 19156 Latent cooling 3144 TOTALS 1361 32879 22300 1004 1004 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. winghtsoft Right-Suite ResidentialTM 5.0.28 RSR25708 2001-Sep-1720:1429 CCA C:Tahmeo-wheeler Sr.Res.D-Unit.rsr Page 2