HomeMy WebLinkAbout203 Bourbon Street (4)PERMIT #
Application For 6328 5937 K'DEPARTMENT DECISION HeatingPermit
Cts N
0
3E APPLICATION IS HEREBY:DEPARTMENT OF LICENSES AND INSPECTIONS
N +'APPROVED DISAPPROVED
TOWN OF SOUTH WINDSOR
C1
1.4
Ca 7/9/84 Thomas P. D' Auria
00 O DATE CHIEF INSPECTOR APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW
O
A
E •C 1. LOCATION OF JOB
O a,
203
cis 9 NO.
r
STREET
O
CD u
LOT NO. FLOOR APT. NO.
O 0O
79
4) O
2. OWNER
S O
O s. ADDRESS
bo
4.FHONE
D
V2 S. APPLICANT
s. ADDRESS43
7.PHONE
w 'O
v S. LICENSE NO.
Q
O 4S. EXPIRATION DATE OF LICENSE
10. ESTIMATED COST s
N
11. IS THIS A CONTRACT COST? YES Oita
b0
12. FEE ENCLOSED : e rm i t #13 8 3 8
ai is. TYPE 0 BUILDING:
bobR[SID[MTU1L COMMERCIALOA
14. TYPE OF JOB: INDUSTRIAL
4 3
TALLATI N ADDIT ONONRI
REPAIR
APPLICATION FOR HEATING PERMIT (Continued it m Reverse Side)
11. LOCATION OF JOB I'd 7 4-3 GZ>/.L ll(
NO. STRE[T FL OR AFT.NO.
12. TYPE OF INSTALLATION: OIL BURNER ELECTRIC VENTILATION SPRINKLER
GAS BURNER STACK INCINERATOR MISCELLANEOUS
IDENTIFY
SIZE LOCATION SIZE SIZE
13. OF TANK OF TANK OF FILL OF VENT
14. B.T.U. EQUIP. AT REGISTER FrRE MAKE AND NO. AT BONNET FIRING RATEN
I'd
AC,
BOILER OR FURNACE MAKE AND N0. B.T.U. OR SQ. FT. NET B.T.U. OR SQ. FT. GROSS FIRING RATE
FLOORS TO BE HE TED NEW OR OLD BUILDING ";Z((-i i I SULATED - YES OR NO
TYPE OF WALL INSULATION ROOF OR CEILING INSULATION
AVG. SYSTEM ATER TEMP. la T.U./SQ. FT./HR. EMISSION
INDOOR-OUTDOOR TEMPERATURE DIFFERENCE d FAHRENHEIT
MAKE OF RADIATION: ASEBO RD, COPPER CONVECT S. OR C.I. RADIATION. OUTPUT P SECTION OR LINEAL OF RADIATION. SO.
FT. OR B.T.U. L
DESCRIPTION OF WORK
15. TO BE DONE:
16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS):
ROOM SIZE WINDOWS AREA - SQUARE FEET B.T.U. S.T.U. F D
AND DOORS VOLUME DISTRIBUTION INSTALLED
TOTAL TOTAL
ROOM NO. GROSS GLASS NET WALL CEILING FLOOR CU. AT 70•F CORRECTED t j RAD. REGISTER
L W N AND E TEMP. TO F TYPE AND SIZE OR LEADER
SIZE < WALL
f'LSO INFILT.)
DIFF. F Sl N SQ. FT. FREE AREA
TOTALS
A. HEAT LOSS FROM BUILDING--- 7 B.T.U./HR.
B. DOMESTIC HOT WATER DEMAND B.T.U./HR.
C. PIPING. OTHER THAN NORMAL B.T.U./HR.
ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR
17. ELECTRICAL WORK BY:-
NAME ADDRESS
SUBCONTRACTORS AND
IS. THEIR TRADES
ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (A T) OF THIS PROPERTY AND WILL
BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE.
APPLICATION TO BE COMPLETELY FILLED IN.
DATE SIGNATURE OF APPLICANT
w
I = B= R CC LCULATION SHEET 1503 (Modern Method)
l
Copyright 1977 by The Hydronics Institute
OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE
COL.A COL.B COL.C COL.D COL.E COL.F COL.G
1 'ROOM 119 h 7 Cj j2-
c
O H L W H L W H L W H L W L W Design Water Temp.
2 ROOM DIMENSIONS, FT. U y S— S—1 o 1 r/
H
BTUH per F t of 1
3 LENGTH EXPOSED WALLS, FT. Q Q Q42 Radiation Selected 1
4 WINDOW AND OUTSIDE DOOR AREA LL l
BTUH BTUH BTUH BTUH BTUH
5 WALL CONSTRUCTION
r ROOM LIN.FT.OFTable9, Line 3 x H) 13 y ere TOTALS RADIATION
6 TYPE OF GLASS FROM LINE 12 SELECTED
B ttom of table used for Line 5) 197 7 0V
7 CEILING CONSTRUCTION C
Table 9. L x W) Gov V V 1-00
B FLOOR CONSTRUCTIONt D
Table 9, L x W or Lin. Ft.)E
9 COLD PARTITION CONSTRUCTION F
Table 9, L x H)
G
10 _e 1 Wall(With Openings) C
3 H 17
2 Walls(With Openings)2x d SyCrzj
3 Walls(With Openings) or Ent. Hall
J 1
11 TOTAL BTUH AT 70F TEMP. DIFFERENCE* 6M 116 3 I'J 0 1141
12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE 3 / K
t /v 3
COL.A COL.B COL.H COL. I COL.J COL.K COL.L TOTAL BTUH TOTAL
1 ROOM L%u_DPI_ g Z T( OF BUILDING RADIATION
cc AT SELECTED
O H L W H L W H L I W H L W H L W DESIGN TEMP.°
2 ROOM DIMENSIONS, FT. U DIFFERENCEJL*
3 LENGTH EXPOSED WALLS, FT. Q
41 WINDOW AND OUTSIDE DOOR AREA u.
BTUH BTUH BTUH BTUH BTUH
5 WALL CONSTRUCTION INCREASE BATHROOM
Table 9, Line 3 x H) v 3 / e"D 1 9 Q Q 4:7v y o-# TOTAL 20%
6 TYPE OF GLASS
Ov Q 7 A// B ttom of table used for Line 5) v /
tFOR CONCRETE FLOOR ON7CEILINGCONSTRUCTIONGROUNDORFILLATTable9,L x W) GRADE LEVEL,USE LINEAR
S FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE
Table 9,L x W or Lin. Ft.)
9 COLD PARTITION CONSTRUCTION
Table 9, L x H)
10 _c 1 Wall(With Op nings) C f
ll G C//
4 2 Walls(With Openings)X T-C/
3 Walls(With Openings)or Ent. Hall
J
TAL BTUH AT 70F TEMP. DIFFERENCE*
L BTUH AT DESIGN TEMP DIFFERENCE
Al FORM 1503
e
1
I
B = R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The Hydro/nics institute
OWNER l ADDRESS (d 7- L -"3
DESIGN TEMPERATURE DIFFERENCE F. DATE
COL.A COL.B COL.C COL.D COL.E COL.F COL.G
1 -ROOM a: ,Jj/ -3
Design Water Temp.O H L W H L W H L W H L W H L W
2 ROOM DIMENSIONS, FT. U BTUH per Foot f
3 LENGTH EXPOSED WALLS, FT. Q Radiatf n Selected
41 WINDOW AND OUTSIDE DOOR AREA uC.
BTUH BTUH BTUH BTUH BTUH
5 WALL CONSTRUCTION ROOM LIN. FT.OF
Table 9, Line 3 x H) TOTALS RADIATION
6 TYPE OF GLASS
FROM LINE 12 SELECTED
Bottom of table used for Line 5) 3
7 CEILING CONSTRUCTION C
Table 9, L x W)G Ll D
g FLOOR CONSTRUCTIONt
Table 9, L x W or Lin. Ft.)E
9 COLD PARTITION CONSTRUCTION F
Table 9, L x H)G
10 C 1 Wall(With Openings) 7 H
2 Walls(With Openings)D X IJ
3 Walls(With Openings)or Ent.Hall
J
11 TOTAL BTUH AT 70F TEMP. DIFFERENCE'
12 TOTAL BTUH AT &ESIGN TEMP. DIFFERENCE jO K
L
COL.A COL.B COL.H COL. I COL.J COL. K COL.L TOTAL BTUH TOTAL
OF BUILDING RADIATION
1 ROOM Q AT SELECTED
O H L W H L W H L W H L W H L W DESIGN TEMP.'
2 ROOM DIMENSIONS,FT. F'
DIFFERENCE
U
31 LENGTH EXPOSED WALLS, FT. Q
4 WINDOW AND OUTSIDE DOOR AREA u
BTUH BTUH BTUH BTUH BTUH
5 WALL CONSTRUCTION INCREASE BATHROOM
Table 9, Line 3 x H) TOTAL 20%
6 TYPE OF GLASS
Bottom of table used for Line 5)
tFOR CONCRETE FLOOR ON
7 CEILING CONSTRUCTION GROUND OR FILL AT
Table 9,L x W) GRADE LEVEL,USE LINEAR
g FLOOR CONSTRUCTIONt
FEET OF EXPOSED EDGE
Table 9, L x W or Lin. Ft.)
9 COLD PARTITION CONSTRUCTION
Table 9,L x H)
10 1 Wall(With Openings)
o m3
0 2 Walls(With Openings) X
3 Walls(With Openings)or Ent.Hall F.
AL BTUH AT 70F TEMP. DIFFERENCE'
BTUH-AT DESIGN TEMP. DIFFERENCE
FORM 1503
able from The Hydronics Institute,35 Russo Place,Berkeley Heights,N.J. 07922