Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
202 Kebalo Lane
r Becttyc# APPLICATION FOR BUILDING PERMIT Plumbing#d o2 202 Kebal o Lane WAC # ----II Y915— No 28377 Date: K 30-Nov-01 Sprinkl r# FINAL APPROVALS Estimated Cost $ 7 5,0 0 0.0 0 Building COMPLETE RED BOXED AR AS Permit Fee ng TYPE OR PRINT ONLY Occupancy Fee $ Affidavit 0 SIGN ON REVERSE SID ---Appr.for CO. ija G Total Fee 4 TO BUILDRqG DEPARTMENT,TOWN OF SOUTH WNDSC9 CT Additional Costs $ The undersigned hereby applies to do work according to the following specifications: Job Location 202 Keha_lo Lane(Wheeler Estates SRD)Big 2 Lot No.__A Side of Streetleft Zonw l) Applicant K.E. Emoides LLC Walter Kebalo ManaTeL#86 Address 175 Wheeler Road, South Windsor Zi 074 Lic.# 3065 Owner_K.F. Properties LLC AddreW5 Wheeler Road S h Windsor(FNA 176 Smith Street Architect Gregory Louis Montana Am. Addres35 AI ine Drive Soot Windsor Sq.Ft.N w Area: 1st Fh 350 2nd FI. 0 3rd FL_( Total New Area 1350 Rooms 5 LavatorieD Bathrooms Garages 1 Purpose of this permit: Build condominium unit per plans an J specifications Unit type C Located on the comer of Smith Street and Wheeler Road City Watg(g Well Septic System Sew900 Ins. H.O. S.P. Cert. Area Basem nt Garage Approved by Date f 3 Use Group Construction Type Revised 9/01 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building n se' allowed. Signed I hereby apply for a Certificate of Occupancy for the r d ri in this application for the permit. Signed DO NOT WZTE BELOW THIS LINE INSPECTION COMMENTS Location of Job:AFFIDAVIT Additional Fee$ — 0 State of Connecticut ss.South Windsor Coun of Hartford OwnerW1of Q /1%S LL C Agent for the building erected Contractor under Permit No. 2 8 3 7 7 issued by the Building Department of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorize de said per 't i of exceed the submitted estimated cost Signed Subscribed and sworn to before me this day of A.D.20 Estimated Cost$ 8 9 , 9 4 0 . Difference: $537 . Notary Public Inspection / Approval Date By Appl Code Description Due Whom Code Comment 28377-B 75,000 BO1 FOOTING 12/03/01 CJD A E02 UNDERGROUND 12/07/01 CJD A FOR SERVICE B02 FOUNDATION 12/13/01 JFF A PERIMETER FOOTING DRAINS WITH CONTRACTOR B02 FOUNDATION O1/04/02 CJD A 202 OK P03 ROUGH 03/05/02 CJD A W/C-PLANNER PO4 GAS TEST 03/05/02 CJD A W/C-PLANNER E03 ROUGH 04/15/02 CJD A B03 FRAMING (ROUGH) 05/10/02 CJD A E01 SERVICE 05/28/02 WNB WITH CONTRACTOR B10 FINAL 05/28/02 WNB A WITH CONTRACTOR 11445-H 5,940 10928-P 5,500 17741-E 3,500 Total Est Value 89,940 Dwelling 1,350 65,178.00 Basement 1,350 19,170.00 Garage 319 4,529.80 Smoke Det 7 525.00 BOCA Value 89,402.80 Difference 537.20) DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT PERMIT# Application is hereby: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit# APPROVED 1540 SULLIVAN AVENUE Z. OLD-644 2511 exL 230 Date Building Inspector Apphcahon must W p»in"a i EE SCaiM LL f-- Floor Apt.No- 0 - SI,000 - $13.00 over $1,000 12.00 per$1,000 OWNER KF Properties LLCoranyfractionthereof ADDRESS 175 Wheeler Road South Windsor, CT 06074 OWNERS PHONE# 644-5124 648-4446 APPLICANT Kebalo Electric Co. Inc. Walter Kebalo OWN 5 4 ADDRESS 175 Wheeleir ]toad South Windsor CT 06074 tip -_ p N. ESTIIVIATID COSTS 3,500 IS THIS A CONTRACT COST? YES NO s,: FEE ENCLOSED S - , 1 ` -'• err uAReTYPEOFJOB: X Original Installation Alteration/Addition/Repair Revised 11/95 AP 'h ,C ' yoR yLlzCTRICAL PERMIT( d in ode TYPE QF BUII.DIN . ,WITH AISTHISAPPLICATIONASSOCIATED X RESIDENTIAL BUILDING PERMIT APPLICATION YES'/"NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY INSTITUTION- FACTORYIE STORAGE WDIEER'S NAME GARAGE D USE ` • , RESS Tl Ion STATE Other plow,l . . V"A WIRING METHOD Type NMB TYPE OF INST,''L1 SIZE OF 9RATING OF WIRE USED #3 copper_ " OF METERS NUMBER OF DISCONNECTS x, F c ALUM ,; ]PANELS 1 REMOTE DISCONNECT REf Gw CIRCUITS 5 NUMBER OF POWER N of wrrcHES 2 4 NUMBER OF w r,.' NUMBER OF LIGHT FD(TURES 26 0 NUMBER OF A/C T CRCUrI'a.r..r...—. r ' Y 4 ' LOSS AND.VC CALCULATIONS MUST 4 d 47 ,k IDISCR ON OF WORK rox 1400 sq. ft• off" o unit App qw ,Fy A 0 amp underground service rh I DINMR PEt y 1, T To#=IE nFF POW OR a OF SUCH WORK. T'^f'_'--=f.w ' p k J yy }';-"rig` r •i s t ye, Yf"t' m 7'M: F SI 644"5 z Z4 DATE i r ,r'^lot + .«+, r,i,: ` r yr r i •ly, 7R7 A t r ire r rY /eta.•t r D 4 n5s}.'!4'a,";` .s .b+ 4k.f i _ s "- '' 1 h Y• r "i; +y" ,y y. vr ; rwt il t 4` i r'rw 1`F A J t;i"'v'il'd , i•yh,.s',,,. . t- e r +'i ., Shirley Wilhelm- CRS Approval Confirmation: Request No. 201285 Page 1 From: clpsvc@nu.com> To: WILHEL@SOUTHWINDSOR.ORG> Date: 5/29/02 12:36PM Subject: CRS Approval Confirmation: Request No. 201285 Your approval of the following CRS Request has been successfully processed. CRS Work Request#: 201285 House No: 202 Lot No: Street Name: KEBALO LN Town Name:SOUTH WINDSOR, CT Inspector:JOHN COLLINS Approval Date: May 29, 2002 DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Applicatio ereby: TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT APPRO 1540 SULLIVAN AVENUE Bldg.Permit# r© 644-2511 ext. 230 c>2S:3 Date Buil Inspector Application must be printed or typed Location ofJob: Fo EE SCHEDULE i aL 1,000=$13.00 Street No. Street Lot No. Over$1,000= 13.00 per$1,000 ny fraction thereof Tenant Designation Apt.No. APPLICANT Oi APPLICANT ADDRESS APPLICANT PHONE# W N S OWNER 4N OWNER ADDRESS OWNER PHONE C MID ESTIMATED COST$ IS THIS A CONTRACT COST? es CI No G FEE ENCLOSED$ TYPE OF J B: SORB CO New Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? YES NO rSIDENTIALBUSINESS CURRENT USE AND OCCUPANCY ASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCY EDUCATIONAL INSTITUTIONAL ENGINEER'S NAME PHONE FACTORY STORAGE ADDRESS GARAGE MIXED USE CITY STATE ZIP TYPE OF INSTALLATION SIZE OF MAIN DRAIN NO.OF TOILETS STYLE Z2- NO.URINALS STYLE NO.OF BATHTUBS NO.OF SHOWERS NO.OF LAVATORIES 2 NO.OF CONDUCTORS SIZE NO.OF STACKS SIZE AREA OF ROOF NO.OF CATCH BASINSKc NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES ( KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW YES NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER L&- WATER HEATER: TYPE MANUFACTURER DESCRIPTION OF WORK tOm-iO/W bO I THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. eq,9,4 dtl CON RACTORS LICENSE TYPE STATE SIGNATURE OF APPLICAN DATE f DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby:TOWN OF SOUTH WINDSOR yyBUILDINGDEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 R3 77 Date Building Inspector Application must be printed or typed Location of Job: FEE SCHEDULE k6 RA C l LA&XCE QLIG- 2- UN t 1— 202i-C 0-$1,000=$13.00 Street No. Street Lot No. Over$1,000=A) 5 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT ;CA ofP n-10i ce_ Ini cc 1 np, APPLICANT ADDRESS T APPLICANT PHONE# p — OVI N SF OWNER OWNER ADDRESS 7` w/)cc L ndnor , CT OWNER PHONE D 4 u tQ C ESTIMATED COST$ 9(7 l V IS THIS A CONTRACT COSP.Yes 13 No GCJ FEE ENCLOSED$ TYPE OF JOB: SOR.CO 4New Installation 13 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: HEATING RESIDENTIAL A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC ARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) r GROSS HEATING CAPACITY(INPUT-BTUH) NET RATING(OUTPUT BTUH) TYPE OF FUEL OIL-GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) rcn c 4 nlr cw A 1 c, UN A IS M( TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. a)-: o 5;), cc:),-r c7l CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE I RIGHT-J-S- :-RTFO-RNf_-=---- Entire House - Fahr nh it Mechanical S rvice Job: 09-17-2001 7 Moody Road,Enfleld,CT Phone:1-86a763-5775 Fax:1-860-763-5844 Project • For: Wheeler Sr. Fees. "C"Unit Kebalo Lane, South Windsor, CT Design Information Htg CIg Infiltration Outside db (OF)5 97 Method Simplified Inside db(OF) 70 75 Construction quality Average Design TD (OF)75 22 Fireplaces 0 Daily range M Inside humidity(%) 50 Moisture difference(gr/lb) - 37 HEATING EQUIPMENT COOLING EQUIPMENT Make RHEEM AIR CON Make RHEEM MANUFAC Trade Rheem Trade Rheem RAKA Series RGRA-04(E,N)MAES RAKA-024JA RC BA-2457 Efficiency 93.5 AFUE Efficiency 10.0 SEER Heating input 45000 Btuh Sensible cooling 15960 Btuh Heating output 42000 Stuh Latent cooling 6840 Btuh Heating temperature rise 51 OF Total cooling 22800 Btuh Actual heating fan 751 cfm Actual cooling fan 751 cfm Heating air flow factor 0.024 cfm/Btuh Cooling air flow factor. 0.048 cfm/Btuh Space thermostat Load sensible heat ratio 85 % ROOM NAME Area Htg load Clg load Htg AVF Clg AVF ft2) Btuh) Btuh) cfm) cfm) Foyer 20 2917 725 71 35 Living Room 256 5146 2754 124 132 Bath 48 370 127 9 6 Spare Bedroom 162 3173 2051 77 98 Bedroom W. I. C. 25 111 38 3 2 Master Bath 74 1260 746 30 36 Master Bedroom 270 6773 3242 164 155 Dining Room 147 3737 1097 90 53 Brfst/Kitchen 206 5450 2656 132 127 Stairway/Lndry 86 2130 2267 52 108 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wrightSoft Right-Suite Residentlal*"5.0.28 RSR25708 2001-Sep-17 17:25:53 ACCN C:1Fahmec-Wheeler Sr.Res.C-Und.rsr Page 1 EntireHouse- - -- -p - ---- --1293 - 3106715703751751 Ventilationair' 00 Equip. @1.02RSM16017 Latentcooling2784 TOTALS12933106718801751751 PrintoutcertifiedbyACCAtomeetallrequirementsofManualJ7thEd. AjwrightsoftRight-SuiteResiderttiai-0.28RSR257082001-Sp-1717:25:53 ACCAC:1FahmeawheelerSr.Res.C-Unr.rsrPage2