Loading...
HomeMy WebLinkAbout20 Porter GreenFINAL 7 s Buirlding 1 3 J s APPLICATION FOR BUILDING PERMIT Plumbin HVAC Date: Sprinkler 20 PORTER GREEN Electric Estimated Cost $ 9. 1( Zoning d6 22406 Permit Fee$ Affidavit « d NO.Occupancy Fee $ Eng. Dept.COMPLETE RED BOXED AREAS. Fire Dept.TYPE OR PRINT ONLY Total Fee $ Health Dept. SIGN ON REVERSE SIDE. Approved for'TT Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigneo, hereby applies to do work according to the following s e ifications: Job Locatio Lot No. Side of Street Zone Applican Z r-- r Tel. Address ic.# S RE CITY STATE Owners Address Architect 1yZ _ :(:1J2!2 Address Size New Area: Ft. Front Overall Ft. Deep Overall Total Area 1 Garages o2 Lavatories Size of Lot Dist. from S reet Line Bathrooms R oomst 1 st,3- r*d:?_3rd Purpose of this Permit City Water Well 0 Septic 0 Sewer Use Group b Construction Type 05G Af'&4 ly Gr2 03 CcJE"+G tf —1 c3 BD1A 11/88ApprovedbyDate I h r by agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone in which this building and its use is allowed.1 Signed Cq. 04 1 I hereby apply for a Certificate of Occupancy for the work described in this ap li ation for p mit. 01 Signed DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit#b a Inspections: HVAC Permit# qQ '9bH Inspections: Electrical Permit# 10 Inspections: Sprinkler Permit# Inspections: 90. 00 Coruna of ob AFFIDAVIT Additiooat Fee ..................... State ofConnecticut si. County of Hartford Permit A ....2.2..4.0..6.................. issued by the Dep't of Budding of the'lbwn of South Windsor being dWY sworn.malts cash and say that the actual cost of the completed work authorized under said permit cfid not exceed the most c unnt a=pted BCCd 8valueof . . .7.,. .9A Q Q. . . . . . . . . . . . . . .. Signed . ... .. . .. .... Subscribed and sworn to before me this da;k` . . Estimate Cost:3 7 9 . -i n n no Difference: S 8 . 0 9 7 _ n n Alv ary :r i 7 Inspection / Approval Date By Appl Code Description Due Whom Code Comment 95-22406-B 69,000 BO1 FOOTING 08/14/95 JFH A B02 FOUNDATION 08/21/95 JFF A E01 SERVICE 09/07/95 JFF D CAULK FEED E01 SERVICE 09/08/95 JFF A NOTIFIED NU P02 UNDERGROUND 09/11/95 JFH D NOT DONE P02 UNDERGROUND 09/13/95 JFH A B05 FIREPLACE/CHIMNEY 09/19/95 JFF A B03 FRAMING (ROUGH) 09/25/95 JFH D CALCS ON STEEL BEAM STUDS MISSING E03 ROUGH 09/25/95 JFH A P03 ROUGH 09/25/95 JFH A B03 FRAMING (ROUGH) 09/28/95 JFH A E03 ROUGH 09/28/95 JFH A P03 ROUGH 09/28/95 JFH A B04 INSULATION 10/10/95 JFH A PO4 GAS TEST 10/23/95 JFH A AIR TEST B10 FINAL 10/30/95 JFH A APPROVED FOR CO & CLOSEOUT 95-9627-P 3,000 95-9286-H 4,800 95-13605-E 2,500 Total Est Value 79,300 Dwelling 1,450 59,334.00 Basement 923 11,445.20 Garage 493 6,113.20 Smoke Det 6 450.00 BOCA Value 87,396.91 Difference 8,096.91 SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 20 Porter Green LOT_#73 Reviewed By Engineering) CLARK REALTY, INC. Date Reviewed Approved/Denied 658 ELLINGTON ROAD,SOUTH WINDSOR,CT Reviewed By Planning) BP #_22406_ Ph_# (203)528-6054 Date Review 9J pprov Denied Dat Submitted 10/31/95 FOR 4 f 0 *** As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan 2. Finish grading per approved building permit plan 3. Site work; i.e. trees, shrubs, dumpsters, required parking 4. Utility location; a. sanitary sewer/septic system b. foundation drain c. electrical & telephone d. water e. other C 5. Sewer connection charge paid x 6. Appropriate certification 7. Bonding 8. Planning & Zoning/ Inland Wetlands Considerations Sewer Permit No. 6 3 6`1 Pavement Excavation No. COMMENTS: SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR,' O N>ECTICUT 20 Porter Green LOT #73 R v y O• • (Engineering) CLARK REALTY, INC. Date Reviewed rov Denied 658 ELLINGTON ROAD,SOUTH WINDSOR,CT Reviewed By Planning) BP_#_22406_ Ph_# (203)528-6054 Date Reviewed 2 Approv Denied Dat Submitted 06/28/95 FOR BU LDING PERMIT ***** In accordanc with the Zoning and/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include: Approved Denied N/A 1. Name, address & phone number of owner/applicant 2. Name, address & phone number of plan preparer 3. Zoning Information - i.e. zone, open space, floodway, etc. 4. Plot.Plan at 1" = 451 scale Yoe,..,a. Subdivision reference, abutting properties, etc. j& b. Easements of record c. Lot description, bearings, building lines, distances, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate e. Building location with dimensions. Elevations of proposed finish floor, garage floor & centerline of road at driveway f. Elevations of gravity drainage systems, sanitary foundation drain at the house and the street g. Tentative utility location (gas, water, electric, sepbem, etc.) 1 h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements. (P.E. & L.S.) 5. Sedimentation and erosion control 6. Special Planning & Zoning, Inland/Wetlands considerations (Plans on file w/Town Clerk) COMMENTS: 1 r Mown S'll r ' ^__!fir! •----- - RCN: n IF I1 t• t i i Fib—iFi?—Fib^9 RFI`'h"1flfJ1 H. I.. nnM T 9 PF 0—Us' F-PI FP 9 4'9r 9 4:0f=, i Raymond A LOOM no, r Coraulting Pro,fps Tonal Engineer 15 Woadduak)t'.mna vnMIW CT 0"3-154 c a3 uas-Tao 11d.T C'.nnatrulotion C,c, PAY c20 6MA47 f R ninoon Bored Snuth Rtndmw,M IM 1dp'6 at 0a0 RE,#20 PORTR$Gr STREET Lot 73 RZf1F='D Rmth Vrmdwe,OT I)aar del: Ai.,I ow•reyuHsi,I mett#e at rcnd ma +iiw,wr tN r 't?w wcs<xl t rxrn uurr Lltr. r t e Pik the P'''mo of rsadWbQj M ke structural capacity to support OW lvadl4s hit AuYtt I caust nlvtim The!'wane preseB*Under cor 3hWd= The bewa c9ndsts of tw pWre of 2 X 10'a with We parr ebMe the oamr.The woad is Don Flat Igo, I The beam 64,rpOrtr a trM xhith in turn aupports a MMWI Roar arcs 0 we.0 as fibs roof over the tloa><area,Thns gmV roof tru are alao,ripported by the bo=is qucstwm.The live aid 4W Iaadws taor dit,Ianr arf v ! to compute. I cakulaled Lhe bet crud dWW It 1111 on thr lx tzu fie' full lltx,r livr. Ituullap and ruuf snow lc*dhW as well w dead The benali arm a k%&Letl 6 226 p*1:And the oloovd a strew is IASO psi The sheer a&nflaeed is 75.6 psi and the allowable etrW 1e"ptl.'Tbwlfte,the b"M has aamidderable r In arength,and there is no room to t4s Sorg aaxreative GGd0L If you havc any q%mdoa j.plow call. dinarca r, I lie nd H.Loom*P3. PI M h I I 4 I PERMIT I DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT { 3 6o 5 Application is hereby : TOWN OF SOUTH WINDSOR BUILDING INSPECTION DEPT. APPROVED DISAPPROVED 1540 SULLIVAN AVENUE S1 ! 644-2511 Ext . 230 D to B ng Inspector Application must be printed or typed 1 . LOCATION OF JOBC.J 73 FEE SCHEDULE No . Street 0 — $19000 — 10.00 Floor Apt. No. Ov r $1,000 — 10.00 2 . OWNERper $1 ,000 or fraction thereof 3. ADDRESS 62V 4. APPLICANT i, _ i 5 . ADDRESS 43 6. ESTIMATED COST 7 . IS THIS A CONTRACT COST y 6 C 8 . FEE ENCLOSED $ 4 4: 9. TYP BUILDING : RESIDENTIAL COMMERCIAL 10. TYP OF JOB : Original Installation Alteration/Addition/Repair 00 3A 11 i88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11 . LOCATION OF JOB 1.6//- 3 A Z o NO. STREET APT. NO , 12 . TYPE OF INSTALLATION f 13 . SIZE OF MAIN FEEDER. 240 r Gzz!:1 14 . NO . OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS ! 16 . NO . OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS 18 . NO . OF HEAT CIRCUITS / 19 . NO. OF POWER OUTLETS 20 . NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS 22 . NO . OF POWER CIRCUITS 23. NO. OF LIGHT CIRCUITS C 24. SIZE OF HEAT CIRCUITS Zy 25 . N0. OF MOTORS 26 . NO . OF PANELS 27 . TOTAL WATTAGE / KU) 28 . NO . OF POWER FEEDERS / 29 . NO. OF SWITCHES 30 . A/C LOAD 31. SIZE OF POWER FEEDERS 32 . NO . OF FIXTURES aS 33. TOTAL HORSEPOWER 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : A-73 LICENSE NO.SIGNATURE OF APPLICANT DATE PHONE NUMBER: '' 1 INSPECTOR ' DATE TIME i LOCATION L-A Po f` u ` f 1 INSPECTION: CODE: RESULT(D/A) : BUILDING: ELECTRICAL O r f PLUMBING: HVAC: OTHER: IvyuldwW llahu lip, PERMIT NO. DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT Application is hereby :TOWN OF SOUTH WINDSOR BUILDING INSPECTION DEPT.APPROV DISAPPROVED 1540 SULLIVAN AVENUE c/ Z ' 644-2511 Ext. 230 ate Building Inspector Applications must be printed or typed 1. LOCATION OF JOB: F E E SCHEDULE 2. OWNER: J4( CGv(.7 ,e(,{6-7-/0,y 0 - $1 ,0 0 0 - 10.0 0 3. ADDRESS: (oZ k: LL I,c__7 G 0- A> AO-0 Over $19000 - 10.00 t5o• WitiDSD P-- 0- per $19000 or 4. APPLICANT: 4 Y--1<-D fraction thereof 5. ADDRESS: 3 S-D C#4,0e L cSo- oj",u aSo i2 C? 6. EST. COST: $ -- 7. IS THIS A CONTRACT COST? l/YES NO 00 8. FEE ENCLOSED: $ 0,ht-0 9. TYPE OF BUILDING: RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: RIGINAL ALTERATION INSTALLATION ADDITION REPAIR BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB:TES, GENERAL PLUMBING 12. KIND OF INSTALLATION: cam 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS _STYLE 15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS_ 16A. NO. OF SHOWERS 17. NO. OF LAVATORIES 3 18. NO. OF SINKS_ 19. DISPOSAL I 19A. DISWASHER / 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS_ _SIZE 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERSC r 32. REMARKS AND FURTHER DETAILS ,d`f e q'4 s WATER HEATER 33. TYPE 34. MANUFACTURER fI4 j/ TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY 42 a (',Q ,39. RELIEF VALVE T, r, f R/0 36. TEST PRESSURE LBS. 40. MANUFACTURER I,yA-TLs 37. WORKING PRESSURE f LBS. 41. PRESSURE RELIEF VALVE 0D 38. TYPE 407 uJ,q-7,c 42. MANUFACTURER Gy,q TTS LICENSE NO. DATE SIGNA APPLICANT PHONE NO. 2 (P y(o FOR OF#tCE USE ONLY APP=IFON FOR HVAC PERMIT DATE: 9/14/95 SOUTH WINDSOR EST.COST: BLDC, PERMIT N0.1540 SULLIVAN AVENUE FEE SOUTH WMSOR, CT 06074 FEES: 644--2511 - Ext. 230 0 $19000 - $10.00 1000 or fraction LOCATION OF BUILDING Lot 73, 20 Porter Green thereof - $10.00 Clark Realty, Inc. , 058 Ellington Road, South Windsor, Cr 06074 648-9038 OWNER ADDRESS TOWN PHONE NO. R & E Heating & Cooling, Inc., 310 Nutmeg Road South, South Windsor, CT 06074 282-7782 HVAC CONTRACTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING X TYPE OF BUILDING: RESIDENTIAL X A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR X UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT 75,000 ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE_ CAPACITY_ LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE 0 OF INSIDE _M_°F DIFFERENCE,_OF TOTAL HEAT LOSS (BTUH) 21,740 HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.):Heil NUGM075 High Efficiency Furnace GROSS HEATING CAPACITY (INPUT-BTUH) 75,000 NET RATING (OUTPUT-BTUH) 67.500 IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN (BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT) : TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: Installation of warm air heating A f I P-.'rm-rnl 'inSR74 9/14/95 STATE LICENSE - NAME S TYPE #DATE S A RE OF L ANT 30- qktA APPROVED OATE I - B - A CALCULATION SHEET 1503 (Modern Method)Copyright 1977 by The Hydi ntcs Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL A COL.9 COL.C COL.O COL.E COL.F COL.G 1 ROOM O H L W H L W M L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT.F- U STUN per P of of 3 LENGTH EXPOSED WALLS,FT. Radiation Selected 1 WINDOW AND OUTSIDE DOOR AREA LL BTUH STUN BTUH BTUH STUN 5 WALL CONSTRUCTION ROOM LIN. FT.OF Table 9,Line 3 x H)TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED IB ttom f table used f r Line 5) 7 CEILING CONSTRUCTION C Table 9, L x W) 9 FLOOR CONSTRUCTIONt O_ Table 9, L x W r Lin. F t) E 9 COLD PARTITION CONSTRUCTION Ir Table 9, L x H G 10 C 1 Wall IWlth Openings)C; H e 2 X2Walls(With Openings)a 3 Wells l W ilh Openings)or Ent.Hall J t 11 TOTAL BTUH AT 7OF TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K C L.A _ COL.B COL.H COL. I COL_J COL.K COL.L. TOTAL BTUH TOTAL OF BUILDING RADIATION1ROOM IE AT SELECTED O H L W H L W H L W H L W H L W DESIGN TEMP.• 2 ROOM DIMENSIONS,F T DIFFERENCE 3 LENGTH EXPOSED WALLS. FT sT 1 WINDOW AND OUTSIDE DOOR AREA LL STUN BTUH BTUH STUN BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9, LIns 3 x HI TOTAL 20% 6 TYPE OF GLASS III ttom f tab)•uNd for Line 51 7 CEILING CONSTRUCTION t CONCRETE FLOOR ON GROUND Table 9, L x WI GROUND OR FILL AT GRADE LEVEL,USE LINEAR g FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE Table 9. L x W or Lin Ft l 9 COLD PARTITION CONSTRUCTION ITable 9, L x HI 10 c 1 Well(With Openings)O 0 2 Wells(With Openings? G X 3 WNI•(With Openings) or Ent Hall ie-J - 11 TOTAL BTUH AT 7OF TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE FORM 1503 This form Is available from The Hirdronlcs Institute 35 Russo Place,Berkeley Heights,N J 01922 DETAILED REPORT FOR ENTIRE HOUSE Prepared For : Prepared By : Clark Realty RP 658 Ellington Rd R&E Heating & Cooling So Windsor Ct 06074 Job Name : 195--073 EXPOSURE GLASS NORTH NE/NW EAST SOUTH SE/SW WEST HORZ . TOTAL AREA 15 ; 0 ; 84 , 48 : 0 ; 60 : 0 ; 207 COOLING 201 ; 0 ; 3 ,648 : 1 ,028 , 0 ; 2 ,605 : 0 ; 7 ,483 HEATING ; 602 , 011 • 33370 ; 1 ,926 ; 0 ; 23407 : 0 ; 8 ,305 w_-_________-____________________ BELOW WALLS NORTH NE/NW EAST SOUTH SE/SW WEST GRADE TOTAL AREA 332 , 0 ; 316 , 416 , 0 ; 303 , 0 ; 1 ,367 COOLING ; 229 : 0 ; 218 : 287 : 0 ; 209 : 0 ; 945 HEATING ; 940 ; 0 ; 895 : 1 ,178 : 0 ; 858 : 0 ; 3 ,870 DOORS NORTH NE/NW EAST SOUTH SE/SW WEST TOTAL AREA 21 ; 0 ; 0 ; 0 ; 0 ; 21 :42 COOLING i 66 : oil 01, 0i 0 : 66 :i 132 , HEATING ; 271 : 0 ; 0 ; 0 ; 0 ; 271 ;543 M,--_-_--...-_..._..._.....-_...-__.......-....._......-_...-__.,.._..._....w.__-w_...._..._....._..--_...__...-_..._..r..........._......._...._......,.._ -- FLOOR AREA COOLING HEATING w__________--_____ 1176 0 ; 0 CEILING AREA COOLING HEATING 1176 129 ; 1 ,093 MISCELLANEOUS COOLING LOADS People Sensible Load 2 ,025 Latent Load 4 ,976 Lights & Appl . Load 4 ,437 Latent Safety Btuh 249 Ventilation Load 0 Duct Heat Gain 1 ,050 Infiltration Load 386 Sensible Safety Btuh 777 TOTAL SENSIBLE LOAD 17 ,364 TOTAL LATENT LOAD 5 ,225 Air Changes/Hour 0 .00 Temp . Swing Mult . 1 .00 Total Cooling Load 22 ,589 BTUH Or 1 .88 Tons * * MISCELLANEOUS HEATING LOADS Infiltration Load 5 ,254 Ventilation Load 0 Duct Heat Loss 1 ,722 Safety Btuh 953 Total Heating Load 21 ,740 BTUH *** SUMMARY REPORT Prepared For : Prepared By : Clark Realty RP 658 Ellington Rd R&E Heating & Cooling So Windsor Ct 06074 Job Name: 195--073 DESIGN CONDITIONS OUTDOOR INDOOR SUMMER WINTER SUMMER WINTER Dry Bulb 88 0 78 68 Wet Bulb 75 65 Daily Range 20 Daily Swing 3 .0 Latitude 41 Elevation 1100 Safety Factor ( % ) 5 Latent Factor ( % ) 30 Room Heating Heating Cooling Cooling Name BTUH CFM BTUH CFM Living Room 7 ,883 435 6 ,243 431 Kitchen 2 ,089 115 2 ,719 188 Bedroom 1 5 ,402 298 3 ,600 249 Bedroom 2 3 ,392 187 2 ,253 156 Bedroom 3 2 ,739 151 1 ,825 126 Bathroom 236 13 724 50 21 ,740 1 ,200 17 ,364 1 ,200 HEATING DELTA T 16 .5 COOLING DELTA T 13 .2 NOTE : *** Calculated Airflow is based upon load requirements . Verify that airflow calculated is compatible with selected equipment requirements . *** SUP — 1 9 - 95 TUE T : 42 ,YM ,Y CONSTRUCTION P . 02 Raymond H. Loomis, PE Consulting Professional Engineer 18 Woodduck Fauns Windsor,Cr 06095-1542 203)688-1180 J14J Construction Co.Inc. FAX(203)683-8479 658 Ellington Road South Windsor,CT 06074 14 Sep'95 0505 RE:#20 PORTER GREEN STREET South Windsor,CT Dow JVJ; At your request,I made observations and measurements ofthe wood beam over the garage door for the purpose of rendering an opinion regarding its structural cape ty to support the loedings in the final construction.The house is presently under construcdon. The beam consists of two pairs of 2 X 10's with one pair above the other.The wood is Douglas Fir No. 2.The beam supports a girder truss which in turn supports a smell floor area as well as the roof aver the floor area Three garage roof trusses are also supported by the beam in question. The live and dead loading conditions are relatively complex to compute. I calculated the bending and shear stresses on the beam for full floor live loadings and roof snow loadings as well as dead loadings. The bending stress calculated is 926 psi and the allowable stress is 1,450 psi. The shear stress calculated is 75.6 psi and the allowable stress is 95 psL Therefore,the beam has a considerable reserve in strength,and there is no reason to take any corrective action. If you have any questions,please call. Sincerely, RR and K.Loomist PR RHIAh I OST - 2 - 95 MON T : 54 -TM .T CONSTRUCT I ON P . 03 jujaST HARTFORD WE ING INC. 55 CORNEAU WAY, SOUTH WINDSOR,CT 06074 203)289-2323 FAX(203)289-2908 September 28, 1995 JMi Construction 658 Ellington Rd. South Windsor, CT 06074 Re: qaisl ld Lot 73 e) '&SKO, 44--w ence Nelson Y To Whom It May Concern. This letter is to certify that 1:h&rq Oesigwh a W12x26 steel beam sppning 2 F-0 for the above referenced residewe•lo carry the required building code loads. Very truly yours, Robert D. Elles,P.E.. gi)s"' G RDE/md L•' I !VI South Viirid-S r BUILDING DEPARTMENT wwti.. EASTHARTFORD WELDATGSPRIMARYMISSIONISANDSHALLCONTINUETOBANEWENGLANDSLARGESTANDMOSTDIVERSIFIED FABRICATORS OFSTRUCTZIRAL STEELANDMISCEUANEOUSMETALS.WE MLLCON77NUETO BEA LEADERINTHE INDUSTRYBY PROVIDING UNSURPASSED QUAU7'Y THROUGH COORDINATION,DEDICA770NAND TRAIMNG. FOR OFFICE USE QNLY APPLICATION FOR HVAC PERMIT DATE: S" Ifo-q6 NO. Li tj W TOWN OF SOUTH WINDSOR ESTOPST: BLDC. PERMIT NO. 1540 SULLIVAN AVENUE FEE3Y'.3 0 SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 0 - $19000 - $10.00 1000 or fraction LOCATION OF BUILDING ao Pog-re-1Z 12feJV thereof - $10.00 GAUAIAJ 20 90 ltrm G-A-Mm Uj&4Wd&*t OWNER ADDRESS TOWN PHONE NO. 140 womwS/ Al P Ct 6,AJ 230 HVAC CONTRACMR I ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE b LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) I HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE F DIFFERENCE OF TOTAL HEAT GAIN (BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLI G EQUIPMENT (INCLUDING MAKE & MODEL NO.): LLOWWd< 2'IL-My NNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT) : TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: S qll` 0OF ry t1 ke 1 • # a Ib-A yiw5R 3 3 S- STATE LICENSE - NAME S TYPE #DATE SIGNATURE OF APPLICANT el APPROVED DATE' I - 8 - R CALCULATION SHEET 1503 (Modern Method)Copyright 1971 by The Hydronics Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL A COL.6 COL.C COL.D COL.E COL.F COL.G 1 ROOM fix O H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT.U STUN per f of f 3 LENGTH EXPOSED WALLS,FT. t Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA IL STUN BTUH STUN STUN BTUH S WALL CONSTRUCTION ROOM LIN. FT.OF Table 9.Line 3 x H)TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED Bottom f table used i r Line 5) 7 CEILING CONSTRUCTION C Table 9,L x W) B FLOOR CONSTRUCTIONt D— ITable 9,L x W or Lin. F t) E 9 COLD PARTITION CONSTRUCTION F Table 9,L x H)G 10 C 1 Wall(With Openingii)O; H 2 Wells(With Openings) D X 3 Wells(Wrlh Openings)or Ent.Hall J 1 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K COL.A _ COLS COL.H COL.1 COL_J COL. K COL.L TOTAL BTUH TOTAL 1 ROOM OF BUILDING RADIATION AT SELECTED O H L W H L W H L W H L W H L W DESIGN TEMP.* 2 ROOM DIMENSIONS. FT DIFFERENCE 3 LENGTH EXPOSED WALLS, FT. WINDOW AND OUTSIDE DOOR AREA U. STUH STUN BTUH STUN BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9.Line 3 x H) TOTAL 20% 6 TYPE OF GLASS Ieott m f table used for Line 51 7 CEILING CONSTRUCTION fF CONCRETE FLOOR ON Table 9. L Wt GROUND OR FILL AT GRADE LEVEL,USE LINEAR B FLOOR CONSTRUCTION1 FEET OF EXPOSED EDGE I T able 9.L x W or Lin Ft 1 9 COLD PARTITION CONSTRUCTION ITable 9,L x H) 10 c 1 Wall(With Openings)C 2 Wells(With Openings)e X 3 Wells(With Openings) or Ent Hall J 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE FORM 1503 This form Is available from The Hydronlcs Institute 35 Russo Place,Berkeley Heights.N J 01922 HEATING&AIR CONDITIONING, INC.17 JANAZZO MECHANICAL CONTRACTORS&ENGINEERS SI-302913 PI-201007 P.O. BOX 469 • 148 NORTON ST. • MILLDALE,CONNECTICUT 06467-0469 • TELEPHONE(203)621-7381 Date: S l s'Caw Municipality p , (// n Z flb Re: Application for Permit Janazzo Job # Gco U /70 U Gentlemen: In accordance with Public Act 91-95, this letter authorizes the below named agent to sign the above referenced permit application for Kevin Janazzo. Mechanical Contractor: Janazzo Heating & Air Conditioning, Inc. Job Name: G A Cr 4 //V Job Location: 20 P6 iP7- 6*2 jGee?:r/V Job Description: 4 br —O A 1600 &6nm 1014c2 Starting Date: Authorized Agent: 7 Thank you for your cooperation, JANAZZO HEATING & AIR CONDITIONING, INC. 4 Kevin Janazzo CEO S 1 Connecticut License #302913 r . villtusCh r• i'i, I.r.s are true le a01-itions to be tc,! t,un am, I ,It -nn;iR. r lvr o, :stall be t, t1w _ _rt f; "ndency hi I(D11r,ttn s,- !C- 4 a ;,uilding r•rr t fyi/ i ntcl 7 prc,ved atc Lennox Objective Guide to Installation Comparison JANAZZO HEATING AND A/C INC. P.O. BOX 469 MILLDALE, CT. 06467 203) 621-7381 I " 04/17/96 LOGIC 1000 RESIDENTIAL LOADS ANALYSIS PAGE 1 GAGAIN RESIDENCE 20 PORTER GREEN SOUTH WINDSOR, CT. PREPARED FOR: STEVE CORMIER PREPARED BY: JEREMY CAROTHERS FILE TITLE: GAGIN DESIGN TEMPERATURES (DEGREES F) WINTER INSIDE 70 WINTER OUTSIDE -10 SUMMER INSIDE 75 SUMMER OUTSIDE 95 C DAILY TEMPERATURE RANGE INDICATOR M DESIGN GRAINS RELATIVE HUMIDITY 34 DEGREES NORTH LATITUDE 41 SUMMER AIR CHANGES PER HOUR 0 .5 WINTER AIR CHANGES PER HOUR 0 . 7 CFM CHART FOR A 1, 000 CFM BLOWER HEATING --> <------- COOLING ------> TOTAL HEATING SENS TOTAL COOLING ROOM AREA LOSS AIR GAIN GAIN AIR NO# ROOM NAME SQ FT BTUH CFM BTUH BTUH CFM 1--tr R 1 BATH/REAR ENTRY 40 4111 85 1493 1737 56 2 KITCHEN 144 4404 91 2671 2978 95 3 DINING ROOM 162 8446 174 4073 4456 143 4 LIVING ROOM 298 14017 28,9 6313 7148 229 5 MASTER BEDROOM 180 4600 95- 3878 4535 2 145 7 6 MASTER BATH 40 1415 29 824 868 28 7 HALL 1 88 2250 46 817 915 7" 29 8 BEDROOM 2 149 4269 88 3411 3838 (%k,/123 9 HALL 2 39 117 2 64 64 v 2 10 BATHROOM 40 881 18 1456 1456 47 11 BEDROOM 1 120 4035 83 2792 3219 103 ZONE 1 TOTALS 1299 48544 1000 27793 31213 1000 NO WARRANTY, EITHER EXPRESSED OR IMPLIED IS GIVEN WITH RESPECT TO THE ACCURACY OR SUFFICIENCY OF THE INFORMATION PROVIDED, AND THE USER MUST ASSUME ALL RISKS AND RESPONSIBILITIES IN CONNECTION AO WITH ITS USE THEREOF. 1 00 kI I c7ov 0 S off; 1 W 1,iE L his eertilu d th,it t,iis plan and specifications are tru` pies of the proposed building or alterations to be rected at PO - t,gether with amendments stated in application and sled with plan and I agree to comply with all zoning, im1ding and state I,iws and such orders as shall he sued by the Building Department during pendency i this application and final issuance of a uilding ermit. igned TIl_r/ r 61 its plan is approved subject to the condition that rders and ordinances regulating building shall be n plied .:th 00ditionally Approved These filed with Building Inspector ClorJl Jat• Mo. a STATE OF CONNECTICUT 12/04/1995 f PARTM[-N7- 01" CONSUMER PROTECTION o00010 2 4 r Z '•'= "`"i 165 CAPITOL AVE HARTFORD Cr 06106-I630 EATING, PIPING & COOLING WORK BOARD Be it known that KEVIN M • JANAZZO 24 KINGSWOOD DR SOUTHINGTON, CT 06489 Is hereby certified by the Department of Consumer Protection as a licensed I I UNLIMITED CONTRACTOR — Sl License Number : 00302913 Effective Date: 10/01/95 Mark A. Shiffrin Expiration Date: 8/31/96 Commissioner X.. f.lti A{.•att\ij}:lly- - ___c ...A1Lf —i i^!'ILM. \ 1 ectrtc O r?41 fL R )" ` APPLICATION FOR BUILDING PERMIT20PORTERGREEN Plumbing# lc t , g f WAC # Date: Sprinkler# No. 24110 INAL A w Estimated Cost l o Buildingw ! COMPLETE RED BOXED AREAS Permit Fee Z f- 6 inneeri TYPE OR PRNT ONLY Occupancy Fee $ s Affidavit SIGN ON REVERSE SIDE Appr.for CO.lot flC Total Fee Z' TO BULDW ARTMM,TOWN OF SOUTH WNDSOR,CT Additional Co3t) The undersigned hereby applies to do work according to the following specifications: Job Location Z O Po<4e(" 6",e i,-N Lot No. Side of Street Zone Applicant RV5.5 Tel# Address 2 c) loa r.e r (Orp e Zip Lic.# Owner Rysse I 1 6-C. reA;I Address z c) f -le r 6 f-49 Architect Address Sq.Ft.New Area: 1st Fl. 2nd Fl. 3rd Fl. Total New Area Rooms Lavatories Bathrooms Garages Purpose of this permit: City Water Well Septic System Sewer Ins. H.O. S.P. Cert. Area 9 Basement Garage Approved by Dat f7 Use Croup 4— Construction Type ' ReYW 1/97 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this buikfing and its use is allowed. Signed A I hereby apply for a Certificate of Occupancy for the work described in this application for the permit. Signed G( / DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Inspection / Approval Date By Appl Code Description Due Whom Code Comment 97-24110-B 1,500 B03 FRAMING (ROUGH) 05/30/97 JFH A E03 ROUGH 05/30/97 JFH A P03 ROUGH 05/30/97 JFH A B10 FINAL 05/21/98 JFF D NO ACCESS LEFT OOR TAG B10 FINAL 10/16/98 JFF A APPROVED FOR CO & CLOSEOUT 97-14329-E 250 97-9912-P 75 PERMIT# DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT X-)5,?DEPARTMENT is hereby: TOWN of SOUTH WINDSOR DECISION hereby. BUILDING DEPARTMENT Bld Penmt# IV 1540 SULLIVAN AVENUEAPPROVED 644-2511 ext.230 Date 91n or Application must be printed or typed Locati n ofjob Street No. Street Lot No. FEE SCHEDULE Floor Apt. No. 0 $1,000 - $12.00 Over $1,000 12.00 per$1,000 OWNER or any fraction thereof ADDRESS C-eTOWNERSPHONE62 APPLICANT -OD Ww;--e/1 4;a" ADDRESS 27 e) Pei r 4e C ESTMATED COST$ IS THIS A CONTRACT COST? YES NO FEE ENCLOSED $ TYPE OF JOB:OR-Co Original Installation Alteration/Addition Repair Revised 11/95 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL BUILDING PERMIT APPLICATION YES / NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY INSTITUTIONAL FACTORY STORAGE ENGINEER'S NAME PHONE GARAGE MIXED USE ADDRESS CITY STATE ZIP Other please specify) TYPE OF INSTALLATION/WIRING METHOD G4 SIZE OF MAIN FEEDERS AND RATING OF WIRE USED NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED?YES/NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPERATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK On A1C THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN. BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. NAME STATE LIC SE NO. TYPE SIGNATURE OF APPLACANT PHONE NO. DATE `r 1 I 57 DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT P I Application is hereby: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit# APPROVED 1540 SULLIVAN AVENUEqk,157- eC 644-2511 ext. 230 Date B ' ding Inspector Application must be printed or typed Location ofjob Street No. Street Lot No. FEE SCHEDULE Floor Apt. No. 0 - $1,000 - $12.00 Over $1,000 12.00 per$1,000 OWNER Usse11 G or any fraction thereof G{J ADDRESS OWNERS PHONE# APPLICANT OWF ADDRESS Pln ESTIMATED COST$ C IS THIS A CONTRACT COST? l YES NO 0 r..• v:: FEE ENCLOSED $ f TYPE OF JOB:SOR.Ca Original Installation Alteration/Addition/Repair Revised 10/96 APPLICATION FOR PLUMBING PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION YES / NO RESIDENTIAL BUSINESS CURRENT USE AND OCCUPANCYASSEMBLY MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY INSTITUTION FACTORY ENGINEER'S NAME PHONE STORAGE GARAGE ADDRESS MIXED USE CITY STATE ZIP Other please specify) TYPE OF INSTALLATION SIZE OF MAIN DRAIN NO.OF TOILETS STYLE NO.OF URINALS STYLE NO. OF BATHTUBS NO.OF SHOWERS NO.OF LAVATORIES NO.OF CONDUCTORS SIZE NO.OF STACKS SIZE AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO. OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW YES/NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER WATER HEATER TYPE MANUFACTURE TANKS SAFETY DEVICES TEMPERATURE CAPACITY RELIEF VALVE TEST PRESSURE WORKING PRESSURE PRESSURE RELIEF VALVE TYPE MANUFACTURER DESCRIPTION OF WORK e G i ; THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. NAME STATE LIC SE NO. TYPE SIGNATURE OF A ANT PHONE NO. '!:DATE S DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT APPROVE 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date Building Inspector Application must be printed or typed FFEE SCHEDULE Location ofJob: 20 Peg;( C<.., 1,000=$13.00 Street No. Street Lot No. Over$1,000= 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT v5 0 APPLICANT ADDRESS 2.0 i9h C e( (P APPLICANT PHONE# 0 6 y y SS Sri O W H S't,q OWNER Su,.•t OWNER ADDRESS k OWNER PHONE C ESTIMATED COST$ 160,00 W IS THIS A CONTRACT COST? 0 Yes ®'No l CJ FEE ENCLOSED$ TYPE OF JOB: OR-CO 0 New Installation 12(Alteration/Addition/Repair Pcwe• S Revised 8/99 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? YES NO RESIDENTIAL BUSINESS CURRENT USE AND OCCUPANCY ASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCY EDUCATIONAL INSTITUTIONAL ENGINEER'S NAME PHONE FACTORY STORAGE ADDRESS GARAGE MIXED USE CITY STATE ZIP Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? YES NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK f r W THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT le4Aj4 4e DATE 2 v'!d'