Loading...
HomeMy WebLinkAbout20 Pheasant WayFINAL INSPEC E.ilding y,s/s APPLICATION FOR BUILDING PERMIT Plumbing HVAC Date: J A N U A R Y 4 , 1 9 9 3r Sprinkler 20 PHEASANT WAY Electric i-` Estimated Cost $ 75 , 000. 00 Zonin Permit Fee$ 7 5 0. 0 0 Affidavit q NO. 2 n 3 R 1 Occupancy Fee $ 3 . 00 Eng. Dept. l5 COMPLETE RED BOXED AREAS. Fire Dept. TYPE OR PRINT ONLY Total Fee $ 7 5 3 . 0 0 Health Dept. SIGN ON REVERSE SIDE. Approved for CO: Additional Cost) $ yl TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Location 20 FHEASANT WAY SO.WINDSOR CT Lot No. 52 Side of Street R Zone A. 30 Applicant DART HILL REALTY INC SO.WINDSOR CT Tel. # 644-81 37 Address 658 ELLINGTON RD SO .WINDSOR CT Zip 06074 Lic.# 500356 STREET CITY STATE Owner J .M.J . CONST. CO . INC Address SAME Address SAMEDAVEGOSSELYNAArchitectd Size New Area: Ft. Front Overall 7 4 Ft. Deep Overall 24 Total Area 2Jt404 #Garages 2 689317 Lavatories Size of Lot Dist. from Street Line 5 8 Bathrooms Rooms 1st 4 2nd 4 3rd Purpose of this Permit CONSTRUCTION OF A SINGLE FAMILY DWELLING City Water M Well C7 Septic 0 Sewer U Use Group Construction Type Approved by Date BD,A , /a8 I hereby agree to conform to all the requirements of the Laws of the Stat of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree r that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone in which this building and its use is allowed. Signed DART HILL REALTY INC BY : I hereby apply for a Certificate of Occupancy for the work described in this application for permit. Signed DART HILL REALTY INC BY: u`. DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# Inspections: HVAC Permit#D b " Inspections: Electrical Permit# Inspections: Sprinkler Permit# Inspections: Location of job AFFIDAVIT Additional Fee ....4.. 0 . 0 0 State of Connecticut C WAS7- 1..vcZS0 W, County of Hartford F ,V.O.-., .................... ........of bsAtl/.il.p 9 l. i. Owner I1114iC1.11a..• for building erected under Contractor Permit No. .. .2 0.3.81.... . . ... ....... issued by the Dept of Building of the Tbwn of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized under said permit did not exceed the most current accepted BOCA value of . .$123 , 46.5 . 0 0... . . . . . . . . . , Signed Subscribed and sworn to before me this ..... . . ... .. .. ...day of CR.. .. . .. ..... . ........ A.D.19 .. Estimate Cost:$ 81 , 8 0 0 . 0 0 66541 00Difference: $ ary V Inspection / Approval Date By Appl Code Description Due Whom Code Comment 93-20381-B 75,000 B01 FOOTING 01/08/93 JFH A B02 FOUNDATION 01/21/93 JFH A E01 SERVICE 03/03/93 JFH A RELEASE ISSUED B03 FRAMING (ROUGH) 03/10/93 JFH A B03 FRAMING (ROUGH) 03/22/93 JFH A E03 ROUGH 03/22/93 JFH A P03 ROUGH 03/22/93 JFH A WATER TEST B04 INSULATION 03/22/93 JFH A P02 UNDERGROUND 03/30/93 JFH A WATER TEST B10 FINAL 04/15/93 JFH A 93-12496-E 3,000 93-9193-P 1,900 93-8641-H 1,900 Total Est Value 81,800 Dwelling 2.404 89,380.72 Basement 1,248 12,417.60 Garage 616 7,238.00 Smoke Det 3 225.00 BOCA Value 123,465.29 Difference 41,665.29 4;L0 CERTIFICATE OF OCCUPANCY CHECK LIST Applicant Dart Hill Realty Certificate of Occupancy D Address on Rd. , S.Wo Bldg. Permit No. Ord ! Lot No. P easant Way) Date Reviewed Project PARTRIDGE MEADOW Reviewed By Date Submitted - 3-93 Ag vved As required in the Zoning Regulations, no Certificate-of-occupancy shall be issued until grading plans have been complied with and approved by the .Town Engineer. The minimum requirements shall include: Approved Denied N/A 1 . Approved building permit plan. 2 . Finish grading per approved building permit plan. 3 . Site work; i .e. trees, shrubs , dumpsters, required parking, 4 . Utility location a. Sanitary sewer b. foundation drain c. electrical & telephone d. water e. other 5 . Sewer connection charge paid. 6 . Appropriate certification 7 . Bonding 8 . Planning & Zoning Sewer Permit No. Pavement Excavation No. COMMENTS: Z 1 0 S' #13T°' 11 4- 7 BUILDING PEP11IT CHECK LIST Applicant Dart Hill REalty, Inc. Building Permit No. 3 F5 Address 658 Ellington Rd. , S. W. Date Submitted 6 93 (ec 'd check late; Lot No. 52 #20 Pheasant Way Reviewed by c Project partrirj MedSuk:liui ic: Date /_ 7 -9 41025 In accordance with the Subd vision Regulations, pri r to the bui ing of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include : Approved Denied N/A 1. Name, address & phone number of owner/ applicant. r 2. Name, address & phone number of plan preparer. 3. Zoning information - i.e. zone, open space, floodway, etc. 4 . Plot plan at 1" = 40 ' scale. a. Subdivision reference, abutting properties, etc. b. Easements of record. c. Lot description, bearings, distances, building lines, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate. e. Building location with dimensions. Elevations of proposed finish floor, garage floor & center line of road at driveway. f. Elevations of gravity drainage systems, sanitary & foundation drain at the house and the street. g. Tentative utility location gas, electric, water, etc. h. Title block with name and address of preparer, date appropriate certification, live seal and signature. 5. Sedimentation and erosion control. 6. Special Planning & Zoning, Inland/Wetlands considerations. (Plans on file w/Town Clerk) BUILDING DEPT. PZC IWA/CC WPCA OTHERS COMMENTS• Xy PERMIT # DEPAR TMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby: TOWN OF SOUTH WINDSOR BUILDING INSPECTION DEPT. APPROVED DISAPPROVED 1540 SULLIVAN AVENUE 644-2511 Ext. 230 Date B ding Inspector Application must be printed or typed 1. LOCATION OF JOB rao No . Street FEE SCHEDULE 0 - $1 Floor Apt. No. 000 -10.00s Over $19000 -10.00 2 . OWNER per $1 ,000 or fraction thereof 3. ADDRESS cosg w,,) )d SO Q— C T- O(D O 4, APPLICANT ( LL) ELf:--C =C 5. ADDRESS QC) (- (qS 6. ESTIMATED COST $ 23OOO 7 . IS THIS A CONTRACT COST Yee N 8. FEE ENCLOSED $ 9. TYP OF BUILDING: RESIDENTIAL COMMERCIAL i 10. TYPE OF JOB: L;--`Original Installation Alteration/Addition/Repair BD 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11. LOCATION OF JOB S rA L I NO. STREET APT. NO, 12 . TYPE OF INSTALLATION 13 . SIZE OF MAIN FEEDER 14 . NO. OF LIGHT LOOPS Co 15 . NO. OF HEAT LOOPS j 16. NO. OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS ati 18 . NO. OF HEAT CIRCUITS 19. NO. OF POWER OUTLETS 20. NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS 22 . NO. OF POWER CIRCUITS c,23. NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS (`j 25 . NO. OF MOTORS 26 . NO. OF PANELS 27 . TOTAL WATTAGE_ 28 . NO. OF POWER FEEDERS 3 29 . NO. OF SWITCHES 30. A/C LOAD 31. SIZE OF POWER FEEDERS " zk, 32. NO. OF FIXTURES 33. TOTAL HORSEPOWER 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : LICENSE NO. SIGNATURE OF APPLICANT DATE PHONE NUMBER: S 2o Lot No. Building Permit- Temporary Service Permanent Service- Pursuant to Permit No. -, This Certifies that the Electrical Work for which the above named Permit was granted has been duly inspected and is hereby approved. ElectricianOwner Street ` e. uIIding Inspector PERMIT NO. q q4D DEPARTMENT DECISION APPLI CAT ION FOR Application is hereby : PLUMBING PERMIT TOWi i OF SOUTH WINDSOR APPROVED DISAPPROVED BUILDING INSPECTION DEPT. 644-2511 Ext. 230 D t e B n g inspector Application must be printed or typed. 1. LOCAT N OF JOB: FEE SCHEDULE 2. OWNER: 0 - $1 ,0 0 0 -10 .0 0 3. ADDRES : i Over $1 ,000 -10 .00 per $1 ,000 or fraction thereof 4. APPLICANT: 5. ADDRESS: I L/y 6. EST. COST: $ 7. IS THIS A CONTRACT COST?YES _ 0' 8. FEE ENCLOSED: $ 9. TYPE OF BUILDING: Z::/RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: t,-tRIGINAL ALTERATION INSTALLATION ADDITION REPAID. BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: 6J T-I- eao GENERAL PLUMBING 12. KIND OF INSTALLATION: 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS 3_STYtAez'-15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS_ 16A. NO. OF SHOWERS 17. NO. OF LAVATORIES 18. NO. OF SINKS { 19. DISPOSAL 6-- 19A. DISWASHER 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS SIZE -5' 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND ff& / 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? cj-49? 27. SIZE OF WINDOW 6Y;7 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS 6-- 32. REMARKS AND FURTHER DETAILS WATER HEATER 33. TYPE 34. MANUFACTURER TANKS SAFETY DEVICES TE11PERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE LBS. 40. MANUFACTURER 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE 38. TYPE 42. MANUFACTURER r,e) 2 C:g(9 A, dL46 LICENSE NO. DATE SONATURE OF APPLICANT PHONE NO. FOR OFFICE USE ONLY APPLICATION FOR RVAC PERMIT DATE: 4r 9-3 NO. LJ TOWN OF SOUTH WINDSOR EST.COST v o BLDG. PERMIT NO. 1540 SULLIVAN AVENUE FEE SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 0 - $12000 - $10.00 1000 or fraction LOCATION OF BUILDING s cp s- thereof - $10.00 J1 w. OTY ADDRESS TOWN PHONE NO. Z4 d , Jam,'w , 3 5> HVAC CONT CTOR DRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING 6/ TYPE OF BUILDING: RESIDENTIAL y A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT e ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION C> ADDITIONAL RADIATION TOTAL RADIATION 22,e-, DESIGN TEMP. OUTSID -/d °F INSIDE 7 OF DIFFERENCE ZQ'F TOTAL HEAT LOSS (BTUH) !V37aa HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): I, !2zr,4it-, 114:? t2 2 2 gfy GROSS HEATING APACITI (INPUT-BTUHV SET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN -TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN (BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT): TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and Stat of Conn. Build in Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: STATE LICENSE - NAME & TYPE #DATE StGNATURE OF APPLICANT D DATE BD 4A 11/88 I = B - R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The Hydronics Institute OWNER 1/ ADDRESS DESIGN TEMPERATURE DIFFERENCE-Z-nF. DATE COL.A COL.B COL.C COL.D COL.E COL.F COL.G 1 ROOM Q O H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT.r pep /U oZS/ S' BTUH per Is* t of 3 LENGTH EXPOSED WALLS,FT. 4 3 30 30 Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA BTUH STUN STUN BTUH STUN 5 WALL CONSTRUCTION n ROOM LIN.FT.OF Ci' 4 Table 9,Line 3 x H) Cri / Q O D 0 o O TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED r Bottom of table used for Lino 5) G Q J D t^i c 0 0 O 7 CEILING CONSTRUCTION C 00 Table 9, L x W)o Q L Q Zo Q Q Q p g FLOOR CONSTRUCTIONt D ly dD Table 9, L x W or Lin. F t) E Dy 9 COLD PARTITION CONSTRUCTION F 7 0 Table 9,L x H) 067 ev 10 _0 1 Well(With Openings)C; 11 H 2O 2 w.11s(with Openings) d x p/ p 30 Ti 3 Wells lWith Openings) or Ent.Hall J l 11 TOTAL BTUH AT 7OF TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE D 5` 004f:' KIV L 22COL.A _ -_ —_ COL.B COL.H COL.1 COL.J COL.K COL.L TOTAL BTUH TOTAL BUILDING1ROOMOF RADIATION Ix 41` Q AT SELECTED O H L W H L W H L W H L W H L W DESIGN TEMP.' 2 ROOM DIMENSIONS, FT f DIFFERENCE 3 LENGTH EXPOSED WALLS, FT. QLF 4 WINDOW AND OUTSIDE DOOR AREA LL 3 r 3?j BTUH STUN BTUH BTUH BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9,Line 3 x H) O7 . Q Q20 O— (/o D i TOTAL 20% 6 TYPE OF GLASS Bottom of table used for Line 5) 1-__ 0 0 - /O - OV 0 - 7 CEILING CONSTRUCTION tFOR CONCRETE FLOOR ON n JTable9, L x W)GROUN OR FILL ATcoOadGRADEDLEVEL,USE LINEAR B FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE Table 9.LxW rLin Ft) 9 COLD PARTITION CONSTRUCTION Table 9, L x H) 10 C 1 Well(With Openings)O o l i L 0---- —a - - 00---- - ------ — 2 Walls(With Openings)o°x 3 Walls(With Openings) or Ent. Hall J 11 TOTAL BTUH AT 70F TEMP DIFFERENCE'C 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE Q C This form is eveilebie from The Hydronlcs Institute,36 Russo Piece,Berkeley Heights,N J 07922 FORM 1503