Loading...
HomeMy WebLinkAbout20 Beelzebub Road (2)t : Application No. .......4276.....__.. ........ Permit No. ....4016................... TO THE BUILDING INSPECTOR of the TOWN OF SOUTH WINDSOR, CONN. j........... hereby make application for a permit to (erect (make alteration to) a building according to the following detailed statement of the specifications and plans herewith submitted. (Draw a line through word "erect" or words "make alteration to" as the case may require.) All provisions of the Building By-Laws (Sections 2 to 32 inclusive) shall be complied with in the execu- tion of this work whether specified herein or not. South Windsor, Conn., .-&./40...........fig.................. 19. d-0Siphere .`. ........................... ............. ...... Address-e,...P. z...7 R6....... Location? O side of? ..................................................``............................................... `...... .......... Nearest cross street?...s"' ...... Street No. .................................................... Lot No. ....................... . ...... Owner of land is?ttrp V.................Address -.C?.. E' ...,,..... ..... AddressOwnerofbuildingLs? .................................................................................... Architectis? ..............................................................................................................Address ....................................................................................................................... Builderis? ..................................................................................................................Address ...................................................................................................................... Dimensions of building? ....................................Feet front? .................................... Feet rear? ................. ........... Feet deep? .............................. Extreme height to highest point of roof? ....................................................................... No. of stories in height? ......................................... Purposeof building is? ....................................................................................No. of stores? ........................................................................................................ Howmany families? .........................................................................................No. of rooms? .... ................................................................................................... Distance from street line is? .....................................................................from building line is? .................................................... ADDITIONS AND ALTERATIONS Give Brief Descriptio P. t. .... 7. a r............. . ..... .............. Cep........ ".1..... .......... J................................................................................... MapNo. ............................. If of steel frame, what is exterior construction? ....................... ......................................................................................................................................... What kind of columns used? ..................................................................Size of columns used? . ................ Whatlength of columns used? ...............................................................How protected? ............................................................................ ............. ... What kind of beams or girders? ........................................................Size of beams or girders? ........................................................................... Longestspan of beams or girders? ......................................................These rest on? ........................................................................................................ Roofconstruction is? .......................................................................................Roof covering is? ............................................................................................... The floors are of ............................................................ construction and are calculated to carry a safe load of ..................................... lbs. per square foot. See Section 14, Building By-Laws.) BRICK CONSTRUCTION. Ofwhat material will walls be constructed? ....................................................................................................................................................... ................. Compositionof mortar? ................................................................................................................................................................................................................................ Height and Thickness of Walls Height Stories Front Walls Side Walls Rear Walls Partition Walls Basement, 1st Story 2nd " 3rd 4th 5th " 6th " 1 h '/ I.......................................«....................................... ............................................. ............................................. ................................................ .................................................... 8t (! I............................... ................................................... ............................................I ............................................ ............................................... .................................................... 9th " 10fh.................................................................................................................................. ...................................... Material.of Front? ............................... If stone, what kind? .............. .... Thickness of Ashlar? ...................................................................................Thickness of Backing? ....... ........................................................................ Backed up with what? ............................. . . .. . Arches or lintels over openings? . WOOD CONSTRUCTION. Give Size, Longest Span and Distance Between Centres, of Joists, Girders and Columns JOISTS GIRDERS COLUMNS Floors Size Longest Span Centres Bridging Size Longest Span Centres Size Length Centres 1st Floor tea.....66 .............. .................................. a.....o...... I .............. .............................. I... 4 .... ..... Size of outside studs?Distance on centres.? Size of sill? Size of rafters? .......................................... Distance on centres?................................................... Size of plate? ...................................................... Size of ledgers or girts? ...................................:.............................................Size of deck rafters? ...................................................................... ............... Distance on centres? .........................................................................................Size of studs in bearing partitions? .................................................. MISCELLANEOUS Style of roof, flat,.pitch, Mansard, or hipped? ............................. Fireplaces? Material of roof'covermg? ........................................................................Material of Cornice? ....................................................................................... Howis building heated? .............................................................................Lining of flues? .............................................................................. ............. Thickness of shell of flues? ........................................................................Any elevators or lifts? ............................................................ ...................... Whatkind? ...................................................... How many? ......................................................... Any hoistways? .......................................................... How protected? .................. .......................................................... .................Total Value of Building .............................................................................. Whenwill work be commenced? ..................................................................................................................................................................................................... The applicant warrants that the lot for residential purposes, shown on a plot plan accompanying this application, conforms to the zoning regulations of the Town of South Windsor. Town of South Windsor since 1949. Applicant Li. liL l BUILDING APPLICATION 4276 ApplicationNo. ............................................................................ 11orth aide of on the ......................................................................... 3e.. e:. lze. bub. .. .. . ...... Rd. .............................. Street. 20 StreetNo, ......................................................................................... Robert Green Owner ..................................................................................................... Same Applicant ............................. . .............................................................. CLASSIFICATION Demolish greenhouse I...................... Permit issued on above Application. July 9, 62 Date, ..................................................... 19............ 1` TOWN OF SOUTH WINDSOR BUILDING PERMIT Date July 9, 19 62 Fee Paid a$. 2-. 0 0 h, Est. Value $ Permit N? 4 016 on the North side of Beelzebub Rd* Street Street No. 2 0 Owner Robert Green Applicant S ame CERTIFICATE OF OCCUPANCY ISSUED: Date No. Fee Paid $$ CLASSIFICATION Demolish greenhouse BUILDING PERMIT N° 4016 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn. —jely 9 0 19 62 94is 'to to Terftf1j, That Robert Green is hereby granted permission to Demolish greenhouse at estimated value of y$ on tlNor th side of 20 Beelzebub Rd. Street on land owned by Hobert Green Said Work to be as described in Application No. 4276 and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR. 52 Iss duly 9uecj9r Building Inspector. Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECT ICUT: "When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compelled to reason therefor." Application No. .....699................... ............. Permit No. ...6.692.................... TO THE BUILDING INSPECTOR of the TOWN OF SOUTH WINDSOR, CONN. hereby make application for a permit to (erect (make alteration to) a building according to the following detailed statement of the specifications and plans herewith submitted. (Draw a line through word "erect" or words "make alteration to" as the case may require.) All provisions of the Building By-Laws (Sections 2 to 32 inclusive) shall be complied with in the execu- tion of this work whether specified herein or not. 1.1_1SouthWindsor, Conn., ......... f....................... 19.... Sign here . Address .. 1_ .......... .... /.... .. t Location? v ........................... le4................................side of? .......................................................................................................................... Nearestcross street? ........................................................................................Street No. ..................................................... Lot No. ................................... Owner of land is? .. Address Ownerof building is? ..... I........... !............................I.!....................Address .... .................................................................................................................. Architectis? .............................................................................................................Address ..................................................................................................................... Builder is? ..................................................................................................................Address ...................................................................................................................... Dimensions of building? ....................................Feet front? .................................... Feet rear? ............................. Feet deep? ................... Extreme height to highest point of roof? ....................................................................... No. of atone:in height?......................................... Purposeof building is? ....................................................................................No. of stores? ............................................................................ ...................... Howmany families? .................................... ..,r......................................No. of rooms? .... Distance from street line is? .....................................................................from building line is? ....................................................................................... ADDITIONS AND ALTERATIONS Give Brief Description) S t 4 .. '..........i............. t.e..i, .&,,. ............. MapNo. .............................. If of steel frame, what is exterior construction? .... .........-.... ... ..... --.............................--.....................................................................- ..... What kind of columns used? ----_--------------_Size of columns used? ........................................---........ --. - Whatlength of columns used? -------------------'-Hmw Whmtkind of beams or Size of beams or Longestspan of beams or moy -................................................................................................... Roofconstruction is? _---_-_--' is? ......... .................................................................................. The floors are mf ------------------' construction and are calculated tm carry a safe load mf ......--......''.............. lbs. per square foot. See Section 14 BRICK CONSTRUCTION. Ofwhat material will walls be constructed? ......................................................................................................................................................... ............... Compositionmf mortar? ............................................................................................................................................................................................................................... Height and Thickness of Walls Ne*ht stories Front Walls Side W&Hs Rear Wans Partition WaHs ist story 6th do 7th do 8th 'I 9th is Material.of Front? .........................................................................................If stone, what kind? ---------------------____-_-__ Thickness of Ashlar? ............. Thickness of WOOD CONSTRUCTION. Give Size, Longest Span and Distance Between Centres, of Joists, Girders and Columns JOISTS GIEDZBS COLUMNS Floors She Longest Span Centres Bridging Size Longest Span Centres Sim Length Centres 1st Floor Via........... a.....;....... .............. .................................. 4 .... Size of outside studs? .......................................... Distance on centres? ................................................ Size of sill? ............................................... Size of rafters? .......................................... Distance on centres?................................................... Size of plate? ...................................................... Size of ledgers or girts? .................................................................................Size of deck rafters? ..................................................................... ............... Distance on centres? .........................................................................................Size of studs in bearing partitions? .................................................. MISCELLANEOUS Style of roof,fiat,.pitch, Mansard, or hipped? ................I... Fireplaces? Material of roof covering? ........................................................................Material of Cornice? ....................................................................................... Linn of flues? ..................How is building heated? ................................................... g Thickness of shell offlues? ........................................................................Any elevators or lifts? ............................................................ ...................... Whatkind? ...................................................... How many? ........................................................ Any hois ays? ......................................................... p Total Value of Buil ' g ..' ..`i. ............../.How protected? Whenwill work be commenced? ..................................................................................................................................................................................................... The applicant warrants that the lot for residential purposes, shown on a plot plan accompanying this application, conforms to the zoning regulations of the Town of South Windsor. Town of South Windsor since 1949. Applicant OOye BUILDING APPLICATION Application No. 99 onthe .................................................................................. Side o Beelzebub Rd. Street. StreetNo, ............. 20.................................................................... Owner Rob. ert...... J......... Br. e. e. n Applicant ....... Bur. t. on... W.. LOOMIs.......................CLASSIFICATION Install aluminum siding on existing dwelling. To be grounded. I................ Permit issued on above Application. Date, .. 5- 6-. 69.......................... 19............ 4 TOWN OF SOUTH WINDSOR BUILDING PERMIT Date May 6 p 19 69 Fee Paid 18. 00 Est. Value $ 2435. 00 Permit 6692 on the side of Beelzebub Rd. Street Street No. 20 Owner Robert J. Breen Applicant _ Burton W. Loomis CERTIFICATE OF OCCUPANCY ISSUED: Date No. Fee Paid $ CLASSIFICATION Install aluminum siding on existing dwelling. To be grouaded. BUILDING PERMIT N° 6692 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn.my 62 19 69 T4io to to Terftf1j, That Burton W. L0*Mi, is hereby granted permission to Install aluminum s 1_3 ing on existing dwelling. To be gr aunded . at estimated value of y$24 5.00 on the side of Beelzebub Rd, "'>O Street on land owned by Robert J. Green Said W*rk to be as described in Application No. 6992 and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR. 60069Issue 9./ 00000-B din nspector. Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: `When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compelled to reason therefor." x r. F r y,. `. _. w ,• x6 ..,<. . Y.:.. r.. ....,a' 3., k xi,YL Sk, .KI ,". r W rF k a, .t• >;'2x° t x f a'- .:;€'„tvr fiT w° 61, a ji art ,"C iTr +"."?..+ AATO IW ILDR Ris, R 4f the NOTT UK-, iOUa" 'WIND OR, C NN. hereby make action for a permit to (erect (ss is a min tn) a building according to the following detailed statement of the specifications and plans herew subnutted. (Draw a word "erect" or words "make alteration to" as the cast may require.) All p t+Q W, of the Building By-Laws (Sections 2 to 32 inclusive) shall be comphed with"in the execu- tion, of this work whether specified herein ae not. South Windsor, Conn., ............... ..........+......... C• A here .................................. Address.aig.a...... Location? ............................................. .........0 G..e 70-e........... side of? ...............`6.............................................,"""................................,............. Nearest cross str .-. p `T, .... Street No. .............................. Lot No. .............. Owner of land is? ..(. _47oo ;:7......... /..5"/ ......Address .-'" ........... gsr,r .... Ownerof building is? ..........'`........................................ `.:.....................Address ``......................................... .............................................. Architectis? ........................ • Address .............w.... Builder is. II ......... ................ Dimensions of building?/ Feet front. Feet rear? ............................. Feet deep? ..............................g• «` Extreme height to highest point of roof? ....................................................................... No. of stories in height?......................................... Purpose of building is? .....................n.e.cr:_ # .......................No. of stores? ......................................:..... Howmany families? .........................................................................................No. of rooms? .... .................. .. Distance from street line is? .....................................................................from building line is? .................................... ADDITIONS AND ALTERATIONS Give Brief Description) c r'tins........... :w............ .. ......... ................. 2.... ........... 2 .. ..... ....... 1../ .... ........................................................... MapNo. .............................. If of steel frame, what is exterior construction? ................... .. ........ ........................... .. ....................................................................... What kind of columns used?Size of columns used? . ............ ........................................... ............ Whatlength of columns used? ...............................................................How protected? .... ................................................................ ............. ... What kind of beams or girders? ........................................................Size of beams or girders? .............................................................I.....I...... Longestspan of beams or girders? .....................................................These rest on? .. ............................................................................................. Roof construction is? R The floors are of ............................................................ construction and are calculated to carry a safe load of .. . ......... ............. lbs. per square foot. See Section 14, Building By-Laws.) BRICK CONSTRUCTION. Ofwhat material will walls be constructed? ......................................................................................................................................................... ................. Compositionof mortar? ................................................................................................................................................................................................................................ Height and Thickness of Walls Height Stories Front Walls Side WARS Rear Walls Partition Walls Basement, I....................................................................................... I........................... I...................................... ..................................................... ist Story 2nd I............................ .......................... 3rd r...............................................I................................................ 4th is 5th do 11......................................................................................................... 6th do jj 7th so I........................................................................................................ 8th is do9th 10th Material.of Front? ................................................... ........................................If stone, what kind? .............. . ................................................................... Thicknessof Ashlar? ............ .....................................................................Thickness of Backing? . .............................................................................. Backed up with what? .. . . ....... Arches or lintels over openings? a w#„' fts i`"a;`j"„' r..;. r , t sTs t r gu 4 r ''t`'Xht+{ 'd. " .4 Yut';x ;:,..,,.;Y.. e .. .. s• ,f',„y. k. e:. a r ' . ,,,„ 57 r ,, w -n, .` q sY,. CS >. '.s^rb., 2 rz*,%i >.;»5,:`i.t r'' ..¢ nY' ,• „--n , '. s;C MR#x,PSy 4,taL.w lx ii Mom' 7V71, h' tk Ail, Sift a FOX I»»., N.. .....,..NIN...................Y....,N..:..a......... N.........N: IN.INYNNI.iIN. e of WOUJOWUS Style of rao flstt, or N...........»..... Material of roof c+ov ? ......... ......... ... .........................Material of Co 116? ... ..... ........... How is building heated? ..................................................................».........](.in` of$ue:? ...................... Thickness of shell of flues? ........ .......... ...............................................Any elevators or lifts' ................................. ..................... ...................... Whatkind? ...................................................... How many? ......................................................... Any hoistwa , How- Total Valtu of r`.....a When will work be commenced? The applicant warrants that the lot for residential purposes, ;shown on a plot plan accompanying this application, conforms to the zoning regulations of the Town of South Windsor. Town of South Windsor since 1949. 4D Applicant BUILDING APPLICATION 4316 ApplicationNo. ......... ...............................................................on the ......... . 0.... r.. t....... h side of Beelzebub Rd. Street. StreetNo, ....... 2. 0............................ I............................................. Robtrt Green Owner ................................................................................................. r, E. Petrunti Applicant .. 0..*........................ I.....................................................CLASSIFICATION Enlarge back porch to I......................................................... I.............................. ..................... lu f ,- T r, t L_,. . ............... . .... ....................................................Permit issued on above Application. July 30. 9 62 Date, .................... ............................ 19............ TOWN OF SOUTH WINDSOR BUILDING PER ART Date July 30, 1962 Fee Paid Est. Value $. 75 0. 0 0 Permit N? 4056 on the North side of Beelzebub Rd. Street Street No. 20 Owner Robert Green Applicant C. E. Petrunti CERTIFICATE OF OCCUPANCY ISSUED: Date No. Fee Paid $ CLASSIFICATION Enlarge back porch to 101xl5 e i 1 BUILDING PERMIT N° 4056 OFFICE OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn. July 3 0 j. 1962 ig4is t"' to TPrttf1j.9 That C•E. Fetrunti is hereby granted permission to Enlarge bank porch to 101x151 at estimated value of $ 750#00 on the North side of 20 Beelzebub Rd* Street on land owned by Robert Green Said tfork to be as described in Application No. 4316 and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR. Issued {.July 3 0 1962 Building Inspector. Streets and sidewalks, obstructed by excavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costs and damages which it shall sustain, or be compelled to reason therefor." FINAL INSPECTIONS: Building APPLICATION FOR BUILDING PERMITPlumbing HVAC Dater/6-8 Sprinkler 20 BEELZEBUB ROAD Electric Estimated Cost $9MC.o'Zoni g Permit Fee $Affidavit NO. 17989 Occupancy Fee $ 3 stsEng. Dept. Fire Dept. COMPLETE RED BOXED AREAS. Total Fee $91Z acn Health Dept. TYPE OR PRINT ONLY Approved for CO: SIGN ON REVERSE SIDE. TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Location a 4 Lot No. AV _Side of Street AJ Zone Applicant Ama) Lee & w Tel. # eflVP,81Y Address .26 Zip 66 07f"' Lic.# Z4 Owner Address Architect Address_ Size New Area: Ft. Front Overalls Ft. Deep Overall 171 Total Area 228 SF #Garages 0 LavaiunesNo. of Families I No. of Stories Construction fe R• Bath rooms-- _Rooms 1 st___1_2nd — 3rd Size of Lot 4,1 Go $ - t Dist. from Street Lane 0 Dist. from Side Street Line Nl f Purpose of this ermit 70 1eEAf10dE' CR/3i1w.< 404.4t., r ditI ,,sot-,,, sf,«,,T City Water O Well fl0r/`* Septic 11 Sewer Approved by ,5;A Date 7r1 Yp BD1A 11/88 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South WindsorandtonotifytheBuildingInspectorofanyalterationintheplansorspecificationsoftheBuildingforwhichthispermitisasked,and agreethatthisbuildingistobelocatedtheproperdistancefromallstreetlines,side yard lines and required distances from all other zones and is located in a zone in which this building and its use is allowed. Signed I hereby apply for a Certificate of Occupancy for the work described in this application for permit. Signed DO NOT WRITE BELOW THIS LINE— rj* INSPECTION RECORD A\^1 b41 Footing ka4t` at( Foundation v1 d Insulation 10-'0—'17 Plumbing Permit# Inspections: HVAC Permit# Inspections: vk Electrical Permit# Inspections: **9)3 Sprinkler Permit# Inspections: PERMIT # DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Po So Application is hereby: TOWN OF SOUTH WINDSOR APPROVED 1=&." BUILDING INSPECTION DEPT. 8 644- 2511 Ext. 230 Application must be printed or typed. Date Building Inspect 1. LOCATION OF JOB FEE SCHEDULE No . Street 0 - $ 19000 - 10. 00 Floor Apt . No. Over $ 1, 000 - 10. 00 per $ 1, 000 or 2 . OWNER C , t fraction thereof 3. ADDRESS Spo,"-- 4. APPLICANT 5 . ADDRESS S A 6. ESTIMATED COST $ 7 . IS THIS A CONTRACT COST Yes No 8 . FEE ENCLOSED r 9 . TYPE BUILDING:RESIDENTIAL COMMERCIAL 10. TYPE OF JOB :Original Installation Alteration/ Addition/ Repair BD 3A 11/ 88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11 . LOCATION OF JOB Zb gzEZ2,F a!, NO . STREET APT. NO 12 . TYPE OF INSTALLATION ¢p r/ Ov L 54)) 13. SIZE OF MAIN FEEDER 16d 14. NO. OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS 16. NO. OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS 18. NO . OF HEAT CIRCUITS 6 19. NO. OF POWER OUTLETS 20. NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS G 22 . NO. OF POWER CIRCUITS 3 23 . NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS C3 25 . NO. OF MOTORS G 26 . NO. OF PANELS C) 27 . TOTAL WATTAGE 28 . NO. OF POWER FEEDERS 29 . NO. OF SWITCHES Z 30. A/C LOAD A le- 31. SIZE OF POWER FEEDERS 32. NO. OF FIXTURES_ 33 . TOTAL HORSEPOWER 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES ,y otic- 35 . REMARKS AND FURTHER DETAILS : LICENSE NO.SIGNATURE OF PLICANT DATE PHONE NUMBER: L/ ' /L/ FINAL INSP CTION Building APPLICATION FOR BUILDING PERMIT Plumbing HVAC Date: Sprinkler 20 BEELZEBUB ROAD Electric Estimated Cost $ 0 Zoning IV Permit Fee$ 2% Affidavit NO.19361 Occupancy Fee $ Eng. Dept. COMPLETE RED BOXED AREAS. Fire Dept. TYPE OR PRINT ONLY Total Fee $ Z2 Health Dept. SIGN ON REVERSE SIDE. Approved for 1 (Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Location E29b Lot No. Side of Street Zone oC Applicant 2iE'6 ttje Tel. # Address .210 C 1a- 54IA-10. Zip 64,07S1 Lic.# STREET CITY STATE Owner S ` ddress Architect / o'' Address Size New Area: Ft. Front Overall t. Deep Overall y Total Area Garages Lavatories No. of Families No. of Stories Construction Bathrooms Rooms 1st 2nd 3rd Size of Lot Dist. from Street Line Dist. from Side Street Line Purpose of this Permit City Water Well Septic Sewer Approved by L Date BD1A 11/88 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor _ and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone in which this building and its use is allowed. Signed L I hereby apply for a Certificate of Occupancy for the work described in this application for permit. r Signed f" DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# Inspections: HVAC Permit# Inspections: Electrical Permit# Inspections: d CAA A .... Sprinkler Permit# Inspect) ns: t,411 y BUILDING INSPECTION DEPARTMENT SOUTH WINDSOR, CONNECTICUT FEE PAID: $3.00 CERTIFICATE OF OCCUPANCY ZONE: DATED 8/5 19 91 This is to certify that 20 Beelzebub Road Erected under permit No. 19361 conforms substantially to the requirements of the building ordinances and the zoning regulations of the Town of South Windsor and is hereby approved for occupancy as indicated below. Approved for Occupanoy— Above Ground pool USE GROUP: U CONSTR. TYPE: 2C Building Official Notice:If this certificate is lost or destroyed,a duplicate should be obtained immediately from the Building Department. Any change or extension of the use herein approved requires a new certificate of occupancy. 3 4'+7' w' f r k 9 o 1 M z e GIET J U L 2 3 1991 South Windsor BUILDING DEPARTMENT irICATION OF ZONING CO t• Proposed building(s), use(s) and/or structl-C, roe^ s shown on this plan appear(s) to b b ru d conformance with current S.,Jjth egulations. Variances and special exceptions PIS may apply. 11 e,-o x.3 p 061INIed that this pfat1IL+ Q'` vos a1 ch® P+an and Y 1 I:rc se j °wif JinR or1 Si 1.4cttec at ment officerZoningEnforce Z YS `P) gttkar w4th amendn-w;ats state, in v with plan :end i _• t c' Maly ,v a!dlrig and o do Jed by, f this: aap'ic tiori a.;,, final issu?n(7i r.,r,it, 14red nos. p!an is, -, dreved c* Lt. Ise r.un iCfr.,Ind ')r':Lnaric-s 1ri_.fl<+tln, !JUl,!i:I" ndrtional!-.Approves spector i 93 l PERMIT # DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby: TOWN OF SOUTH WINDSOR APPROVED DISAPPROVED BUILDING INSPECTION DEPT. 644- 2511 Ext. 230 LS aj Application must be printed or typed. Date Bu ' ding Inspector 1. LOCATION OF JOB as & C zf. b0. , b R6 FEE SCHEDULE No. Street 0 - $ 19000 - 10. 00 Floor Apt . No. Over $ 1, 000 - 10. 00 per $ 1 , 000 or 2 . OWNER r( Qh P Lkrle- - 6y fraction thereof 3. ADDRESS aosezfz6hub R6/ 20 4 . APPLICANT 5 . ADDRESS Qi 6 . ESTIMATED COST $ 7 . IS THIS A CONTRACT COST Yes No ' 8 . FEE ENCLOSED $ 9 . TYPE OF BUILDING: 3 / PRESIDENTIAL COMMERCIAL 10 . TYPE OF JOB :Original Installation alteration/ Addition/ Repair BD 3A 11/ 88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11 . LOCATION OF JOB NO . STREET APT. NO , 12 . TYPE OF INSTALLATION 13 . SIZE OF MAIN FEEDER 14 . NO.' OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS 16. NO. OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS 18 . NO. OF HEAT CIRCUITS 19. NO. OF POWER OUTLETS 20. NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS 22 . NO. OF POWER CIRCUITS 23 . NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS 26 . NO. OF PANELS 27 . TOTAL WATTAGE 28 . NO. OF POWER FEEDERS 29 . NO. OF SWITCHES 30. A/C LOAD 31. SIZE OF POWER FEEDERS 32 . NO. OF FIXTURES 33. TOTAL HORSEPOWER 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : R 71 LICENSE NO.SIGNATU E OF APPL ANT DATE PHONE NUMBER: FINAL INSPEC I S: liuildin9 APPLICATION FOR BUILDING PERMIT Plumbin HVAC _ 20 BEELZEBUB ROAD Date: Sprinkler pEstimated Cost $Electric larce S Permit Fee $Zoning 3AffidaitNO. 2 0 8 9 9 Occupancy Fee $ e 645 Eng. Dept. I3FireDept. COMPLETE RED BOXED AREAS.Total Fee $ TYPE OR PRINT ONLY Health Dept. SIGN ON REVERSE SIDE. Approved for CO: s Additional Cost) $ TO BUILDING DEPAF6WNT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Locationr0_ G v Lot No. Side of Street Zone ApplicantTel. # A 9' tic.#Address STREET UlTY STATE Owner Address Architect 4 Address Size New Area: Ft. Front Overall Ft. Deep Overall o2 L/-) Total Area Garages Lavatories Size of Lot Dist.,from Street Line Bathrooms— Rooms lst-1-2nd 03rd 0 Purpose of this Permit z9.5? DecK S' k 20 ' City Water 13 Well Ek'Septic 0 Sewer Use Group Construction Type 55 Approved by < < Date j BD1A 11/88 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agreethatthisbuildingistobelocatedtheproperdistancefromallstreetlines,side yard lines an required distances from,all other zones and is located in a zone in which this building and its use is allowed. Signed I hereby apply for a Certificate of Occupancy for the work described in this ap ation for perm' . Signed DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# 1 Inspections: HVAC Permit# Inspections: Electrical Permit# Inspections: Sprinkler Permit# Inspections: Inspection / Approval Date By App1 Code Description Due Whom Code Comment B20FRAMB ( ROU6H) 0 03 FRAMING 10/ 08/ 93 JFH A E03 ROUGH 10/ 08/ 93 JFH A P03 ROUGH 10/ 08/ 93 JFH A ATION 06/ 29/ 95 JFH A B110 FINAL JFH A APPROVED FOR CO/ CLOSEOUT 93- 9299- P 11650 95- 9167- H 950 93- 12787- E 900 PERMIT 0 DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby : TOWN OF SOUTH WINDSOR BUILDING INSPECTION DEPT. APPROVED DISAPPROVED 1540 SULLIVAN AVENUE G3 644- 2511 Ext. 230 ate g Ina ector Application must be printed or typed 1 . LOCATION OF JOB 2o iqe- elrebtb V, FEE $ CIIEDULE No . Street 0 - $ 19000 - 10. 00 Floor Apt . No. Over $ 1 , 000 - 10. 00 per $ 1 , 000 or 2 . OWNER gr) a. SV.& emlp fraction thereof 3. ADDRESS 0 P. eI z e, t 4. APPLICANT NiG1gae.. I ir h clCt h 1 c; ` r1Ccti) nf clGt J 5. ADDRESS 4cc Chi eefl Xcad,, 6. ESTIMATED COST $ 0 - 001 7, IS THIS A CONTRACT COST Yes No 8. FEE ENCLOSED 9. TY PE OF BUILDING: COMMERCIAL 10. TYPE OF JOB :Original Installation V Alteration/ Addition/ Repair RD 3A 11 i8e APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11. LOCATION OF JOB 17 ctl NO. STREET APT. NO , 12 . TYPE OF INSTALLATION 13 . SIZE OF MAIN FEEDER 14 . NO. OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS 16 . NO. OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS 18 . NO . OF HEAT CIRCUITS 19. NO. OF POWER OUTLETS_ 20 . NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS 22 . NO. OF POWER CIRCUITS 23. NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS_ 26 . NO . OF PANELS 27 . TOTAL WATTAGE 28 . NO . OF POWER FEEDERS 29 . NO. OF SWITCHES 30. A/C LOAD 31. SIZE OF POWER FEEDERS_ 32. NO. OF FIXTURES 33. TOTAL HORSEPOWER_ 34. NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : Cl v 6i-t4 A' C fi?r01C,w! ro 946 LICENSE NO.SIGNATURE OF APPLICANT DATE PHONE NUMBER: I L PERMIT a^ 10. DEPARTMENT DECISION APPLICATION FOR PLUMBING PERriIT Application is hereby : TOWN OF SOUTH WINDSOR BUILDING INSPECTION DEPT. APPROVED DISAPPROVED 1540 SULLIVAN AVENUE tolclns 644- 2511 Ext. 230 Date Bu Inspector Applications must be printed or typed 1. LOCATION OF JOB: 20 O& e lz, dv FEE SCHEDULE 2. OWNER: 0 - 1 0 0 0 - 10. 00 3. ADDRESS: . 20 Zelel- z- i4e,- 1- 4 Over $ 1 , 000 - 10. 00 per $ 1 , 000 or 4. APPLICANT: G, 4// Lac) te c fraction thereof S. ADDRESS: IY.. I Ir r 6. EST. COST: $ l, D 7. IS THIS A CONTRACT COST? YES ENO 8. FEE ENCLOSED: $ ICJ 9. TYPE OF BUILDING: t: ZI' 4 RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: ORIGINAL ALTERATION INSTALLATION _ ADDITION REPAIR BD 2A 11/ 88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: Cl GENERAL PLUMBING 12. KIND OF INSTALLATION:L K 34zg 64* 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS el STYLE2&,ff . 15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS_ Z 16A. NO. OF SHOWERS 17. NO. OF LAVATORIES 18. NO. OF SINKS 19. DISPOSAL 19A. DISWASHER 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS SIZE 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 3 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS c 32. REMARKS AND FURTHER DETAILS 1/ WATER HEATER 33. TYPE 34. MANUFACTURER TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE LBS. 40. MANUFACTURER 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE 38. TYPE 42. MANUFACTURER s LICENSE NO. ATE SIGNATURE OF APPLICANT PHONE NO. t FOR OFFICE USE PNLY APPLICATION FOR HVAC PERMIT , DATE: 2/24/95 NO. TOWN OF SOUTH WINDSOR EST.COST: 950.00 BLDG. PERMIT NO. 1540 SULLIVAN AVENUE FEE 10.00 SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 0 - $19000 - $10.00 1000 or fraction LOCATION OF BUILDING 20 Beelzebub Road thereof — $10.00 Brian Sweeney 20 Beelzebub Road South Windsor 644-8944 OWNER ADDRESS TOWN PHONE NO. Gen Mechanical , Inc. 23 Newsome Road Somers 763-4271 HVAC CONTRACTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM HEATING X TYPE OF BUILDING: RESIDENTIAL X A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING t 4;``" ST - LOW PRESSURE LIMITS. HIGH PRESSURE LIMIT_ LBS. HYDR6RIC X WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM X GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION INSIDE X OUTSIDE CAPACITY 275 LPG TANK = CAPACITY EXISTING RADIATION_ ADDITIONAL RADIATION 22' TOTAL RADIATION DESIGN TEMP. OUTSIDE 4 °F INSIDE 70 OF DIFFERENCE 66 OF TOTAL HEAT, LOSS (BTUH)--TT,740 BTO/Hr HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): Weil-McLain- Series 68 GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) 999000 IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN (BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN ECHAUSE EQUIPMENT): I TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: Baseboard heat for bedroom and bathroom tied into existing heating loop (bedrooms) Heating & Cooling S-1 300914 2/24/95 STATE LICENSE — NAME b TYPE # DATE GNATURE OF APPLICANT lqf APPROVED VATE c BD 4A 11/88 I - B- R CALCULATION SHEET 1503 ( Modern Method) Copytlght 1971 by The Hydronics Institute OWNER ADDRESS OESION TEMPERATURE DIFFERENCE F. DATE COL. A COL. 0 COL. C COL. D COL. E COL. F COL. G 1 ROOM Q O H L W H L W H L W H L W H L W Design Waist Temp. 2 ROOM DIMENSIONS, FT. oTUH oW Foot of 3 LENGTH EXPOSED WALLS, FT. Radiation Selected WINDOW AND OUTSIDE DOOR AREA LL P4 STUN TUH STUH BTUH BTUH 5 WALL CONSTRUCTION ROOM LIN. FT. OF Table 9, Line 3 x H) TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED Bottom of table used for Line 51 7 CEILING CONSTRUCTION C Table 9. L x W) g Cl— FLOOR CONSTRUCTIONt Table 9, L x W or Lin. F t.) E 9 COLD PARTITION CONSTRUCTION F Table 9, L x H) G 10 c 1 Wail( With Opening*) O; H 2 Wells I W ith Opening*) D X 3 Walls lWilh Openings) or Ent. Hall 1 J 11 TOTAL HTUH AT 70F TEMP. DIFFERENCE' K 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE L COL. A COL. B COL. H COL. I COL. J COL. K COL. L TOTAL BTUH TOTAL Of BUILDING RADIATION ROOM AT SELECTED O H L W M L W H L W H L W H L W DESIGN TEMP.* r32" ROOM DIMENSIONS. FT I OIfFERENCE U LENGTH EXPOSED WALLS, FT. d WINDOW AND OUTSIDE DOOR AREA LL STUN TUN BTUH BTUH BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9, LIna 3 x HI TOTAL 20% 6 TYPE OF GLASS 19ottom of table used for Line 5) fFOR CONCRETE FLOOR ON 7 CEILING CONSTRUCTION GROUND OR FILL AT Table 9, L x W) GRADE LEVEL, USE LINEAR FEET OF EXPOSED EDGE g FLOOR CONSTRUCTIONt Table 9. L x W or Lin Ft.) 9 COLD PARTITION CONSTRUCTION ITable 9, L x H) 10 c 1 Well( With Openings) 2 Walls( With Openings) p X J 3 Wells( With Opening%) or Ent. Hall 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE FORM 1503 This form Is available from The Hydtonlcs Institute. 36 Russo Place, Berkeley Heights, N J 01922 RIGHT-J LOAD AND EQUIPMENT SUMMARY 242E-95 For: BRIAN SWEENEY 20 BEELZEBUB ROAD SOUTH WINSOR CT 06074 By: GEN MECHANICAL, INC. 23 NEWSONE ROAD SOMERS CT 06071 ADDITION TO EXISTING HOUSE Job Wthr#: Windsor_Locks,_Bradley CT Zone : WINTER DESIGN CONDITIONS SUMMER DESIGN CONDITIONS Outside db: 4 Deg F Outside db: 88 Deg F Inside db: 70 Deg F Inside db: 75 Deg F Design TD: 66 Deg F Design TD:13 Deg F Daily Range M Rel. Hum. : 50 Grains Water 29 gr HEATING SUMMARY SENSIBLE COOLING EQUIP LOAD SIZING Bldg. Heat Loss 13140 Btuh Structure 0 Btuh Ventilation Air 0 CFM Ventilation 0 Btuh Vent Air Loss 0 Btuh Design Temp. Swing 3.0 Deg F Design Heat Load 13140 Btuh Use Mfg. Data n Rate/Swing Mult. 0.95 Total Sens Equip Load 0 Btuh INFILTRATION LATENT COOLING EQUIP LOAD SIZING Const Qual a Fireplaces 0 Internal Gains 460 Btuh Ventilation 0 Btuh HEATING COOLING Infiltration 0 Btuh Area (sq.ft. ) 436 0 Tot Latent Equip Load 460 Btuh Volume (cu.ft. ) 3884 0 Air Changes/Hour 1.2 0.5 Total Equip Load 460 Btuh Equivalent CFM 78 0 HEATING EQUIPMENT SUMMARY COOLING EQUIPMENT SUMMARY Make WEIL-Mclain Make Model 68 Model Type Type Efficiency / HSPF 84. 1 COP/EER/SEER 0.0 Heating Input 0 Btuh Sensible Cooling 0 Btuh Heating Output 99000 Btuh Latent Cooling 0 Btuh Low Output Basebrd 590 Btuh/Ft Total Cooling 0 Btuh Total Low Basebrd 22 Feet Actual Cooling Fan 0 CFM High Output Basebrd 0 Btuh/Ft Clg Air Flow Factor 0.000 CFM/Btuh Total High Basebrd 0 Feet Space Thermostat Load Sens Heat Ratio 0 MANUAL J: 7th Ed. RIGHT-J: V1.74 SIN 3953 RIGHT-J CALCULATION PROCEDURES A,B,C,D Job #: 2-26-95 Procedure A - Winter Infiltration HTM Calculation* 1. Winter Infiltration CFM 1.2 AC/HR x 3884 Cu.Ft. x 0.0167 78 CFM 2. Winter Infiltration Btuh 1.1 x 78 CFM x 66 Winter TD = 5651 Btuh 3. Winter Infiltration HTM 5651 Btuh / 65 Total Window = 86.4 HTM Door Area Procedure B - Summer Infiltration HTM Calculation* 1. Summer Infiltration CFM 0.5 AC/HR x 0 Cu.Ft. x 0.0167 0 CFM 2. Summer Infiltration Btuh 1. 1 x 0 CFM x 13 Summer TD =0 Btuh 3. Summer Infiltration HTM 0 Btuh / 0 Total Window = 0. 0 HTM Door Area Procedure C - Latent Infiltration Gain 0. 68 x 29 gr.diff. x 0 CFM = 0 Btuh Procedure D - Equipment Sizing Loads 1. Sensible Sizing Load Sensible Ventilation Load 1. 1 x 0 Vent.CFM x 13 Summer TD = 0 Btuh Sensible Load for Structure (Line 19) 0 Btuh Sum of Ventilation and Structure Loads 0 Btuh Rating and Temperature Swing Multiplie x 0.95 RSM Equipment Sizing Load - Sensible 0 Btuh 2. Latent Sizing Load Latent Ventilation Load 0. 68 x 0 Vent.CFM x 29 gr.diff. = 0 Btuh Internal Loads = 230 x 2 No. People + 460 Btuh Infiltration Load From Procedure C 0 Btuh Equipment Sizing Load - Latent 460 Btuh Construction Quality is: a No. of Fireplaces is: 0 MANUAL J: 7th Ed. RIGHT-J: V1.74 S/N 3953 Printout certified by ACCA to meet all requirements ofManual Form J Job #: Zone: 2-26-95 MANUAL J: 7th Ed. ---- RIGHT-J: V1.74 ---- SIN 3953 --- Page 1 ---- 1 Name of Room Entire House BEDROOM 2 Running Ft. Exposed Wall 62.0 Ft. 57.0 Ft. 3 Room Dimensions, Ft.18.0 x 22.0 Ft. 4 Ceiings,Ft I Condit. Option 8.5 9.0 heat only TYPE OF CST HTM Area Btuh Area Btuh EXPOSURE NO. Htg IClg Length Htg I Clg Length Htg I Clg 5 Gross a 12C 5.9 1.5 553 **** **** 513 **** **** Exposed b 0.0 0.0 0 **** **** 0 **** **** Walls and c 0.0 0.0 0 **** **** 0 **** **** Partitions d 0.0 0.0 0 **** **** 0 **** **** e 0.0 0.0 0 **** **** 0 **** **** f 0.0 0.0 0 **** **** 0 **** **** 6 Windows a 3A 36.4 ** 32 1165 **** 21 777 **** Glass b 8M 36.4 ** 33 1212 **** 33 1212 **** Doors Htg. c 0.0 ** 0 0 **** 0 0 **** d 0.0 ** 0 0 **** 0 0 **** e 0.0 ** 0 0 **** 0 0 **** f 0.0 ** 0 0 **** 0 0 **** 7 Windows North 0.0 11 **** 0 11 **** Glass NE&NW 0.0 0 **** 0 0 **** 0 Doors Clg. E&W 0.0 55 **** 0 44 **** 0 SE&SW 0.0 0 **** 0 0 **** 0 South 0.0 0 **** 0 0 **** 0 Horz 0.0 0 **** 0 0 **** 0 8 Othr doors lal 1 0.0 0.0 0 0 0 0 0 0 b 0.0 0.0 0------------0 0 0 0 0 9 Net a 12C 5.9 1.5 488 2897 0 458---2722------0 Exposed b 0.0 0.0 0 0 0 0 0 0 Walls and c 0.0 0.0 0 0 0 0 0 0 Partitions d 0.0 0.0 0 0 0 0 0 0 e 0.0 0.0 0 0 0 0 0 0 f 0.0 0.0 0 0 0 0 0 0 10 Ceilings ja 16D 3.5 2.0 436 1525 0 396 1385 0 b 0.0 0.0 0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 0 0 11 Floors IaJ19IJ 1.6 0.0 436 691 0 396 627 0 b 0. 0 0.0 0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 0 0 121 Infiltration a 186.41 0.0 ----651 56511 0 ----551 47291 0 13 Subtot Btuh Loss=6+8. .+11+12 **** 13140 **** **** 1 11453 **** 14 Duct Btuh Loss 0$ 0 **** 0% 0 **** 15 Total Btuh Loss = 13+14 1 13140 **** **** 11453 **** 16 Int. Gains: People @ 300 2 **** 0 2 **** 0 Appl. @ 1200 0 **** 0 0 **** 017SubtotRSHGain=7+8. .+12+16 **** **** 0 **** **** 018DuctBtuhGain0% **** 0 0% **** 0 19 Total RSH Gain = 17+18 0 **** **** 0 20 CFM Air Required 0 0 **** 0 0 21 Baseboard required: Low 22 **** **** 19 **** **** High 0 **** **** 0 **** **** Printout certified by ACCA to meet all requirements of Manual Form J -- Job #: Zone: 2-26-95 MANUAL J: 7th Ed. ---- RIGHT-J: V1.74 ---- SIN 3953 --- Page 2 ---- 1 Name of Room BATHROOM 2 Running Ft. Exposed Wall 5.0 Ft. Ft. 3 Room Dimensions, Ft. 5.0 x 8.0 Ft. x Ft. 4 Ceiings,Ft I Condit. Option 8.0 heat only TYPE OF CSTJ HTM Area Btuh Area Btuh EXPOSURE I NO. Htg jClg Length Htg Clg Length Htg Clg 5 Gross a 12C 5.9 1.5 40 **** **** Exposed b 0.0 0.0 0 **** **** Walls and c 0.0 0.0 0 **** **** Partitions d 0.0 0.0 0 **** **** e 0.0 0.0 0 **** **** f 0.0 0.0 0 **** **** 6 Windows a 3A 36.4 ** 11 388 **** Glass b 8M 36.4 ** 0 0 **** Doors Htg. c 0.0 ** 0 0 **** d 0.0 ** 0 0 **** e 0.0 ** 0 0 **** f 0.0 ** 0 0 **** 7 Windows North 0.0 0 **** 0 Glass NE&NW 0.0 0 **** 0 Doors Clg. E&W 0.0 11 **** 0 SE&SW 0.0 0 **** 0 South 0.0 0 **** 0 Horz 0.0 0 **** 0 8 Othr doors jal 0.0 0.0 0 0 0 b 0.0 0.0 0 0 0 9 Net a 12C 5.9 1.5 29 174 0 Exposed b 0.0 0.0 0 0 0 Walls and c 0.0 0.0 0 0 0 Partitions d 0.0 0.0 0 0 0 e 0.0 0.0 0 0 0 f 0.0 0.0 0 0 0 10 Ceilings ja 16D 3.5 2.0 40 140 0 b 0.0 0.0 0 0 0 c 0.0 0.0 0 0 0 11 Floors IaJ19IJ 1.6 0.0 40 63 0 b 0.0 0.0 0 0 0 c 0.0 0.0 0 0 0 121 Infiltration a 186.41 0.0 111 9221 0 I 13 Subtot Btuh Loss=6+8. .+11+12 ****1688 **** **** 14 Duct Btuh Loss 0$ 0 **** 15 Total Btuh Loss = 13+14 1688 **** **** 16 Int. Gains: People @ 300 0 **** 0 Appl. @ 1200 0 **** 0 17 Subtot RSH Gain=7+8. .+12+16 **** **** 0 **** **** 18 Duct Btuh Gain 0% **** 0 19 Total RSH Gain = 17+18 0 **** **** 20 CFM Air Required 0 0 **** 21 Baseboard required: Low 3 **** **** High 0 **** **** Printout certified by ACCA to meet all requirements of Manual Form J -- o MANUAL J: 7th Ed. RIGHT-J: V1.74 SIN 3953 RIGHT-J WINDOW DATA Job #: 2-26-95 W S D W G L S S 0 N A S 0 O W C W S N K I A L O T H V G N H V V H H N H D Y R L A W R A H L G C R R G T A A W L Z E M D G Z L O X Y T M R R BEDROOM a n n a c n n n n 2 90 1.0 0.0 0.0 1.0 21.0 10.7 0.0 a n w a c n n n n 2 90 1.0 0.0 0.0 1.0 70.0 10.7 0.0 b n e a c n n n n 2 90 1.0 0.0 0.0 1.0 70.0 33.3 0.0 BATHROOM a n w a c n n n n 2 90 1.0 0.0 0.0 1.0 70.0 10.7 0.0 RIGHT-J LOAD AND EQUIPMENT SUMMARY 4-06-95 For: BRIAN SWEENY 20 BEELZEBUB ROAD SOUTH WINDSOR CT 06074 By: GEN MECHANICAL, INC. 23 NEWSOME ROAD SOMERS CT 06071 EXISTING HOUSE LOAD Job #: Wthr : Windsor_Locks,_Bradley CT Zone : WINTER DESIGN CONDITIONS SUMMER DESIGN CONDITIONS Outside db: 4 Deg F Outside db: 88 Deg F Inside db: 70 Deg F Inside db: 75 Deg F Design TD: 66 Deg F Design TD:13 Deg F Daily Range M Rel. Hum. : 50 Grains Water 29 gr HEATING SUMMARY SENSIBLE COOLING EQUIP LOAD SIZING Bldg. Heat Loss 57205 Btuh Structure 0 Btuh Ventilation Air 0 CFM Ventilation 0 Btuh Vent Air Loss 0 Btuh Design Temp. Swing 3 .0 Deg F Design Heat Load 57205 Btuh Use Mfg. Data n Rate/Swing Mult. 0.95 Total Sens Equip Load 0 Btuh INFILTRATION LATENT COOLING EQUIP LOAD SIZING Const Qual a Fireplaces 0 Internal Gains 0 Btuh Ventilation 0 Btuh HEATING COOLING Infiltration 0 Btuh Area (sq.ft. ) , 1132 0 Tot Latent Equip Load 0 Btuh Volume (cu. ft. ) 9056 0 Air Changes/Hour 1.0 0.5 Total Equip Load 0 Btuh Equivalent CFM 151 0 HEATING EQUIPMENT SUMMARY COOLING EQUIPMENT SUMMARY Make WEIL-McLAIN Make Model 68 Model Type Type Efficiency / HSPF 84. 1 COP/EER/SEER 0.0 Heating Input 0 Btuh Sensible Cooling 0 Btuh Heating Output 99000 Btuh Latent Cooling 0 Btuh Low Output Basebrd 590 Btuh/Ft Total Cooling 0 Btuh Total Low Basebrd 97 Feet Actual Cooling Fan 0 CFM High Output Basebrd 0 Btuh/Ft Clg Air Flow Factor 0. 000 CFM/Btuh Total High Basebrd 0 Feet Space Thermostat Load Sens Heat Ratio 0 MANUAL J: 7th Ed. RIGHT-J: V1.74 SIN 3953 RIGHT-J CALCULATION PROCEDURES A,B,C,D Job #: 4-06-95 Procedure A - Winter Infiltration HTM Calculation* 1. Winter Infiltration CFM 1. 0 AC/HR x 9056 Cu.Ft. x 0. 0167 151 CFM 2 . Winter Infiltration Btuh 1. 1 x 151 CFM x 66 Winter TD =10980 Btuh 3 . Winter Infiltration HTM 10980 Btuh /215 Total Window = 51. 1 HTM Door Area Procedure B - Summer Infiltration HTM Calculation* 1. Summer Infiltration CFM 0.5 AC/HR x 0 Cu.Ft. x 0.0167 0 CFM 2 . Summer Infiltration Btuh 1. 1 x 0 CFM x 13 Summer TD =0 Btuh 3 . Summer Infiltration HTM 0 Btuh / 0 Total Window = 0. 0 HTM Door Area Procedure C - Latent Infiltration Gain 0. 68 x 29 gr.diff. x 0 CFM = 0 Btuh I Procedure D - Equipment Sizing Loads 1. Sensible Sizing Load Sensible Ventilation Load 1. 1 x 0 Vent.CFM x 13 Summer TD = 0 Btuh Sensible Load for Structure (Line 19) 0 BtuhSumofVentilationandStructureLoads0Btuh Rating and Temperature Swing Multiplie x 0.95 RSM Equipment Sizing Load - Sensible 0 Btuh 2. Latent Sizing Load Latent Ventilation Load 0. 68 x 0 Vent.CFM x 29 gr.diff. = 0 Btuh Internal Loads = 230 x 0 No. People + 0 BtuhInfiltrationLoadFromProcedureC0BtuhEquipmentSizingLoad - Latent 0 Btuh Construction Quality is: a No. of Fireplaces is: 0MANUALJ: 7th Ed. RIGHT-J: V1.74 SIN 3953PrintoutcertifiedbyACCAtomeetallrequirementsofManualForm J Job #: Zone: 4-06-95 MANUAL J: 7th Ed. ---- RIGHT-J: V1.74 ---- SIN 3953 --- Page 1 ---- 1 Name of Room Entire House FAMILY ROOM 2 Running Ft. Exposed Wall 166.0 Ft. 58.0 Ft. 3 Room Dimensions, Ft.14.0 x 22 . 0 Ft. 4 Ceiings,Ft I Condit. Option 8.0 8. 0 heat only TYPE OF CST HTM Area Btuh Area Btuh EXPOSURE NO. Htg IClg Length Htg I Clg Length Htg I Clg 5 Gross a 12A 17.9 4.5 1328 **** **** 464 **** **** Exposed b 0.0 0.0 0 **** **** 0 **** **** Walls and c 0.0 0.0 0 **** **** 0 **** **** Partitions d 0.0 0.0 0 **** **** 0 **** **** e 0.0 0.0 0 **** **** 0 **** **** f 0.0 0.0 0 **** **** 0 **** **** 6 Windows a lA 65.3 ** 145 9474 **** 29 1911 **** Glass b 0.0 ** 0 0 **** 0 0 **** Doors Htg. c 0.0 ** 0 0 **** 0 0 **** d 0. 0 ** 0 0 **** 0 0 **** e 0.0 ** 0 0 **** 0 0 **** f 0.0 ** 0 0 **** 0 0 **** 7 Windows North 0.0 16 **** 0 0 **** 0 Glass NE&NW 0.0 0 **** 0 0 **** 0 Doors Clg. E&W 0.0 64 **** 0 29 **** 0 SE&SW 0.0 0 **** 0 0 **** 0 South 0.0 65 **** 0 0 **** 0 Horz 0.0 0 **** 0 0 **** 0 8 Othr doors jaj10D 30.4 7.6 70 2125 0 23 708 0 b 0.0 0.0 0 0 0 0 0 0 9 Net a 12A 17.9 4.5 1113 19907 0 411 7359 0 Exposed b 0.0 0.0 0 0 0 0 0 0 Walls and c 0. 0 0.0 0 0 0 0 0 0 Partitions d 0.0 0.0 0 0 0 0 0 0 e 0.0 0.0 0 0 0 0 0 0 f 0.0 0.0 0 0 0 0 0 0 10 Ceilings ja 16C 5.8 2.4 1132 6575 0 308 1789 0 b 0.0 0.0 0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 0 0 11 Floors la 19F 7.2 0.0 1132 8144 0 3'08 2216 0 b 0.0 0.0 0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 0 0 121 Infiltration a 151. 11 0.0 2151 109801 0 531 26851 0 13 Subtot Btuh Loss=6+8. .+11+12 **** 57205 **** **** 1 16668 **** 14 Duct Btuh Loss 0$ 0 **** 0% 0 **** 15 Total Btuh Loss = 13+14 1 57205 **** **** 16668 **** 16 Int. Gains: People @ 300 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 17 Subtot RSH Gain=7+8. .+12+16 **** **** 0 **** **** 0 18 Duct Btuh Gain 0% **** 0 0% **** 0 19 Total RSH Gain = 17+18 0 **** **** 0 20 CFM Air Required 0 0 **** 0 0 21 Baseboard required: Low 97 **** **** 28 **** **** High 0 **** **** 0 **** **** Printout certified by ACCA to meet all requirements of Manual Form J -- Job #: zone: 4-06-95 MANUAL J: 7th Ed. ---- RIGHT-J: V1.74 ---- SIN 3953 --- Page 2 ---- 1 Name of Room LIVING ROOM HALL/ENTRY 2 Running Ft. Exposed Wall 28.0 Ft. 8 . 0 Ft. 3 Room Dimensions, Ft. 16.0 x 12 .0 Ft. 8 . 0 x 10.0 Ft. 4 Ceiings,Ft Condit. Option 8.0 heat only 8_0- heat only TYPE OF CST HTM Area Btuh Area Btuh EXPOSURE NO. Htg Clg ( Length Htg I Clg Length Htg ( Clg 5 Gross a 12A 17.9 4 .5 224 **** **** 64 **** **** Exposed b 0. 0 0.0 0 **** **** 0 **** **** Walls and c 0. 0 0.0 0 **** **** 0 **** **** Partitions d 0. 0 0.0 0 **** **** 0 **** **** e 0.0 0. 0 0 **** **** 0 **** **** f 0. 0 0.0 0 **** **** 0 **** **** 6 Windows a lA 65. 3 ** 30 1960 **** 0 0 **** Glass b 0.0 ** 0 0 **** 0 0 **** Doors Htg. c 0.0 ** 0 0 **** 0 0 **** d 0. 0 ** 0 0 **** 0 0 **** e 0.0 ** 0 0 **** 0 0 **** f 0. 0 ** 0 0 **** 0 0 **** 7 Windows North 0. 0 0 **** 0 0 **** 0 Glass NE&NW 0.0 0 **** 0 0 **** 0 Doors Clg. E&W 0. 0 0 **** 0 0 **** 0 SE&SW 0.0 0 **** 0 0 **** 0 South 0.0 30 **** 0 0 **** 0 Horz 0.0 0 **** 0 0 **** 0 8 Othr doors 1a110D 30.4 7. 6 0 0 0 23 708 0 b 0.0 0.0 0 0 0 0 0 0 9 Net a 12A 17.9 4 .5 194 3470 0 41 727 0 Exposed b 0. 0 0.0 0 0 0 0 0 0 Walls and c 0.0 0.0 0 0 0 0 0 0 Partitions d 0.0 0.0 0 0 0 0 0 0 e 0. 0 0.0 0 0 0 0 0 0 f 0.0 0.0 0 0 0 0 0 0 10 Ceilings a 16C 5.8 2.4 192 1115 0 80 465 0 b 0. 0 0.0 0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 0 0 11 Floors a 19F 7.2 0.0 192 1381 0 80 576 0 b 0. 0 0.0 0 0 0 0 0 0 c 0. 0 0.0 0 0 0 0 0 0 12I Infiltration a 151. 11 0. 0 301 15321 0 231 11921 0 13 Subtot Btuh Loss=6+8. .+11+12 9459 3668 14 Duct Btuh Loss 0$ 0 **** 0% 0 **** 15 Total Btuh Loss = 13+14 1 9459 **** ****3668 **** 16 Int. Gains: People @ 300 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 17 Subtot RSH Gain=7+8. .+12+16 **** **** 0 **** **** 0 18 Duct Btuh Gain 0% **** 0 0% **** 0 19 Total RSH Gain = 17+18 0 **** **** 0 20 CFM Air Required 0 0 **** 0 0 21 Baseboard required: Low 16 **** **** 6 **** **** High 0 **** **** 0 **** **** Printout certified by ACCA to meet all requirements of Manual Form J -- Job #: Zone: 4-06-95 MANUAL J: 7th Ed. ---- RIGHT-J: V1.74 ---- SIN 3953 --- Page 3 ---- 1 Name of Room BEDROOM #1 BEDROOM #2 2 Running Ft. Exposed Wall 11.0 Ft. 23.0 Ft. 3 Room Dimensions, Ft. 12.0 x 11.0 Ft. 12.0 x 11.0 Ft. 4 Ceiings,Ft I Condit. Option 8.0 1 heat only 8. 0 heat only TYPE OF CST HTM Area Btuh Area Btuh EXPOSURE NO. Htg IClg Length Htg ( Clg Length Htg ( Clg 5 Gross a 12A 17.9 4.5 88 **** **** 184 **** **** Exposed b 0.0 0.0 0 **** **** 0 **** **** Walls and c 0.0 0.0 0 **** **** 0 **** **** Partitions d 0.0 0.0 0 **** **** 0 **** **** e 0.0 0.0 0 **** **** 0 **** **** f 0.0 0.0 0 **** **** 0 **** **** 6 Windows a lA 65.3 ** 18 1143 **** 35 2287 **** Glass b 0.0 ** 0 0 **** 0 0 **** Doors Htg. c 0.0 ** 0 0 **** 0 0 **** d 0. 0 ** 0 0 **** 0 0 **** e 0.0 ** 0 0 **** 0 0 **** f 0.0 ** 0 0 **** 0 0 **** 7 Windows North 0.0 0 **** 0 0 **** 0 Glass NE&NW 0.0 0 **** 0 0 **** 0 Doors Clg. E&W 0.0 0 **** 0 18 **** 0 SE&SW 0.0 0 **** 0 0 **** 0 South 0.0 18 **** 0 18 **** 0 Horz 0.0 0 **** 0 0 **** 0 8 Othr doors jaj10D 30.4 7.6 0 0 0 0 0 0 b 0.0 0.0 0 0 0 0 0 0 9 Net a 12A 17.9 4.5 71 1261 0 149 2665 0 Exposed b 0. 0 0.0 0 0 0 0 0 0 Walls and c 0.0 0.0 0 0 0 0 0 0 Partitions d 0.0 0.0 0 0 0 0 0 0 e 0. 0 0.0 0 0 0 0 0 0 f 0.0 0.0 0 0 0 0 0 0 10 Ceilings JaI16CI 5.8 2.4 132 767 0 132 767 0 b 0.0 0.0 0 0 0 0 0 0 c 0. 0 0.0 0 0 0 0 0 0 11 Floors 1a119F1 7.2 0.0 132 950 0 132 950 0 b 0.0 0.0 0 0 0 0 0 0 c 0. 0 0.0 0 0 0 0 0 0 121 Infiltration a 151. 11 0.0 181 8941 0 351 17871 0 13 Subtot Btuh Loss=6+8. .+11+12 ****5014 **** ****8456 **** 14 Duct Btuh Loss 0$ 0 **** 0% 0 **** 15 Total Btuh Loss = 13+14 1 5014 **** ****8456 **** 16 Int. Gains: People @ 300 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 17 Subtot RSH Gain=7+8. .+12+16 **** **** 0 **** **** 0 18 Duct Btuh Gain 0% **** 0 0% **** 0 19 Total RSH Gain = 17+18 0 **** **** 0 20 CFM Air Required 0 0 **** 0 0 21 Baseboard required: Low 8 **** **** 14 **** **** High 0 **** **** 0 **** **** Printout certified by ACCA to meet all requirements of Manual Form J -- Job #: Zone: 4-06-95 MANUAL J: 7th Ed. ---- RIGHT-J: V1.74 ---- SIN 3953 --- Page 4 ---- 1 Name of Room SPARE ROOM KITCHEN 2 Running Ft. Exposed Wall 12 . 0 Ft. 26. 0 Ft. 3 Room Dimensions, Ft. 12.0 x 10.0 Ft. 14. 0 x 12 . 0 Ft. 4 Ceiings,Ft Condit. Option 8. 0 heat only 8. 0 heat only TYPE OF CST HTM Area Btuh Area Btuh EXPOSURE NO. Htg IClg Length Htg I Clg Length Htg I Clg 5 Gross a 12A 17.9 4 .5 96 **** **** 208 **** **** Exposed b 0. 0 0. 0 0 **** **** 0 **** **** Walls and c 0.0 0. 0 0 **** **** 0 **** **** Partitions d 0. 0 0. 0 0 **** **** 0 **** **** e 0. 0 0. 0 0 **** **** 0 **** **** f 0. 0 0. 0 0 **** **** 0 **** **** 6 Windows a lA 65. 3 ** 18 1143 **** 16 1029 **** Glass b 0.0 ** 0 0 **** 0 0 **** Doors Htg. c 0. 0 ** 0 0 **** 0 0 **** d 0. 0 ** 0 0 **** 0 0 **** e 0. 0 ** 0 0 **** 0 0 **** f 0.0 ** 0 0 **** 0 0 **** 7 Windows North 0.0 0 **** 0 16 **** 0 Glass NE&NW 0.0 0 **** 0 0 **** 0 Doors Clg. E&W 0. 0 18 **** 0 0 **** 0 SE&SW 0.0 0 **** 0 0 **** 0 South 0.0 0 **** 0 0 **** 0 Horz 0. 0 0 **** 0 0 **** 0 8 Othr doors 1a110D 30.4 7.6 0 0 0 23 708 0 b 0. 0 0.0 0 0 0 0 0 0 9 Net a 12A 17.9 4. 5 79 1404 0 169 3021 0 Exposed b 0. 0 0.0 0 0 0 0 0 0 Walls and c 0. 0 0. 0 0 0 0 0 0 0 Partitions d 0.0 0.0 0 0 0 0 0 0 e 0. 0 0. 0 0 0 0 0 0 0 f 0. 0 0.0 0 0 0 0 0 0 10 Ceilings a 16C 5.8 2 .4 120 697 0 168 976 0 b 0. 0 0.0 0 0 0 0 0 0 c 0. 0 0.0 0 0 0 0 0 0 11 Floors a 19F 7.2 0.0 120 863 0 168 1209 0 b 0. 0 0. 0 0 0 0 0 0 0 c 0.0 0. 0 0 0 0 0 0 0 121 Infiltration a 151. 11 0. 0 181 8941 0 391 19961 0 13 Subtot Btuh Loss=6+8. .+11+12 ****5001 **** ****8939 **** 14 Duct Btuh Loss 0 0 0% 0 **** 15 Total Btuh Loss = 13+14 1 5001 **** ****8939 **** 16 Int. Gains: People @ 300 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 17 Subtot RSH Gain=7+8. .+12+16 **** **** 0 **** **** 0 18 Duct Btuh Gain 0% **** 0 0% **** 0 19 Total RSH Gain = 17+18 0 **** **** 0 20 CFM Air Required 0 0 **** 0 0 21 Baseboard required: Low 8 **** **** 15 **** **** High 0 **** **** 0 **** **** Printout certified by ACCA to meet all requirements of Manual Form J -- MANUAL J: 7th Ed. RIGHT-J: V1.74 SIN 3953 RIGHT-J WINDOW DATA 4-06-95 Job #: W S D W G L S S O N A S O V H H N H N K I A L O T H V G N H V D Y R L A W R A H L G C R Y T M R R W L Z E M D G Z L O X FAMILY ROOM a n w a c n n n n 1 90 1.0 0.0 0.0 1. 0 85.0 29.3 0.0 LIVING ROOM a n s a c n n n n 1 90 1.0 0.0 0.0 1.0 44.0 30.0 0.0 HALL/ENTRY BEDROOM #1 a n s a c n n n n 1 90 1.0 0.0 0.0 1.0 44.0 17.5 0.0 BEDROOM #2 a n s a c n n n n 1 90 1.0 0.0 0.0 1.0 44.0 17.5 0.0 a n w a c n n n n 1 90 1.0 0.0 0.0 1.0 85.0 17.5 0.0 SPARE ROOM a n w a c n n n n 1 90 1.0 0.0 0.0 1.0 85.0 17.5 0.0 KITCHEN a n n a c n n n n 1 90 1.0 0.0 0.0 1.0 27.0 15.8 0.0 tOW N Sf 1 r Y T-0 ap Sov 'C'/ • j U 1540 SULLIVAN AVENUE • SOUTH WINDSOR. CONN. 06074 r NOR-CO AREA CODE 203/644-2511 February 10, 1995 Mr. Brian Sweeney 20 Beelzebub Road South Windsor, Ct. 06074 Dear Mr. Sweeney: Re: Building Permit #20899 Our records show that there has been no communication from you regarding your building project approved under Building Permit 20899. A Building Permit expires after six months of inactivity. Please indicate the current status regarding this project within a week of receiving this letter. and arrange for the required inspections. One month from the mailing of this letter, if action is not taken on your part a Caveat will be placed in the land records stating there are Building Code Violations on your property. The Inspectors are available for this purpose between 8:00 - 9:00 a.m. and 1:00 - 2:00 p.m. Your cooperation in this matter is greatly appreciated. Very truly yours, n F. Hogan Building Official 1 9 r PZ6 7- PZ l) evzsr- tl I a' t N r J 1[b i rd EP 1 1993 jouth Windsor BUILDING DEPARTMENT TO THE BUILDING DEPT. TOWN OF SOUTH WINDS01- This certified that this plan and specifications are true coples of the proposed building or alterations to be Mlrected.At together with am(,,;.,'n-len's sts ted c' zo and filed wi it p'an HI.' I a re o mnin. Building and •'a.e a shall be issued b, ttui:. c;pendency aofth's a, ullding permi Signed This p po on that orders and complied with. Condltionalt, App 1 r :i:ed with nJ13u11dilIdigInspector y Clerk No.Date zoom 400 roposed buHding;s), use(s) and!or str t:..,:s w x ZVI s shown on this plan app:,ar(s) to he ri OECy= onfo.rmance with current 5!.jth Wind: ; S'x 20, gulations. Variances and special exceptio: nay apply. mate L Z i g Enaforceme i .0flner