HomeMy WebLinkAbout20 Arnold Way (6)c
PERMIT #
Application For 3898
DEPARTMENT DECISION
0 412 o Heating Permit
c APPLICATION IS HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS
a) +' X11 APPROVED C].DISAPPROVED
TOWN OF SOUTH WINDSOR
o 0 5-2-72
00 G) DATE CHIEF INSPECTOR APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW
O w4j >1
C 1. LOCATION OF JOB
0 9RNot d W9 y
NO./ STREET
0 OU
rn LOT NO. FLOOR APT. NO.
O 0N1
a 0
2. OWNERA
0
0 3. ADDRESS
bo
cnSGL/L I!R SPY U
Jr —mos., /C 4.PHONE
W
S. APPLICANT A21.411D AtB'ie/Z
o ts. ADDRESS S 3 rK I A A
cis YMR NC&F—rg TER XY 7.PHON
a; e. LICENSE NO. 6/
0
w e. EXPIRATION DATE OF LICENSE
0v
a c to. ESTIMATED COST S
71
m o
b0
11. IS THIS A CONTRACT COST? YES NO
a? • Permit #6961
12. FEE ENCLOSED S c
ai 13. TYPE OF BUILDING:
rnrn
JLJ RESIDENTIAL COMMERCIALbo
I ce •N 14. TYPE OF JOB: INDUSTRIAL
ORIGINAL ALTERATION
INSTALLATION ADDITION
REPAIR
APPLICATION FOR HEATING PERMIT (Continued it m R verse Side)
11. LOCATION OF JOB Z 470 2 6 IE7 I"( A'Q L 12 LA y
NO. STREET FLOOR APT.NO.
12. TYPE OF INSTALLATION: Cl OIL BURNER ELECTRIC VENTILATION SPRINKLER
GAS BURNER STACK INCINERATOR MISCELLANEOUS
IDENTIFY
SIZE LOCATION SIZE SIZE
13. OF TANK OF TANK OF FILL OF VENT
14. B.T.U. EQUIP. AT REGISTE,FURNACE MAKE AND NO. AT BONNET FIRING RATE
BOILER OR FURNACE MAKE'7iRD NOS.ZfI1T/OD B.T.U. OR SQ. FT. NETZQQ—B.T.U. OR SQ. FT. GROSS FIRING RATE
FLOORS TO BE HEATED NEW OR OLD BUILDING X EL// INSULATED - YES OR NO y S
TYPE OF WALId oo2,/4B/Jl E INSULATION 10119- C ROOF OR CEILINGt /4e A' G INSULATION,_XI,AC;;_A COLS
AVG. SYSTEM WATER TEMP. y G
B.T.U./SQ. FT./HR. EMI ION
INDOOR-OUTDOOR TEMPERATURE DIFFERENCE 7 - d FAHRENHEIT
MAKE OF RADIATION: BASEBOARD. COPPER CONVrFCTORS, OR C.I. RADIAT OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ.
FT. OR B.T.U.-- S20DESCR
t5. O BE
I
OINE:
ON OF WORK` Zez I/ 11-U
725 rn iCGG CSC c., — TXh'L ESQ TE
is. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS):
ROOM SIZE ANION DOORS AREA - SQUARE FEET 81.T.U. S.T.U.F DISTRIBUTION INSTALLEDVOLUMETOTALTOTALLL
ROOM NO.GROSS GLASS NET WALL CEILING FLOOR CU.FT. AT
M
F CORRECTED t j RAO. REGISTER
L W N AND TEMP. TO f TYPE AND SIZ! OR LEADER
WALL to IMPILT.)SIZE G DIFF• F F m a 8Q. FT. FRlIS AREA
TOTALS
A. HEAT LOSS FROM BUILDING B.T.U./HR.
B. DOMESTIC HOT WATER DEMAND B.T.U./HR.
C. PIPING. OTHER THAN NORMAL B.T.U./HR.
ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR
17. ELECTRICAL WORK BY:
NAME ADDRESS
SUBCONTRACTORS AND
is. THEIR TRADES
ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL
BE DONE IN STRICT ACCORDANCE WITH THE
f
BU IjLDDING/ CODE.
APPLICATION TO BE COMPLETELY FILLED IN.
l L of
DATE I
ATURR OF APPLICANT
s tom.
B=R CALCULATION SHEET 1503 Copyright 1965 by the Institute of Boiler and Radiator Manufacturers
OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE
COL. A COL. B COL. D COL. E COL. F COL. G ROOM
1 ROOM G L L lJ , TOTALS RADIATION
L W H L W H L W L W H L W FROM LINE 12 SELECTED
O will H
2 ROOM DIMENSIONS, FT. U Q v
3 LENGTH EXPOSED WALLS, FT. Q 0- z
Z
C13
4 WINDOW AND OUTSIDE DOOR AREA IL D
BTUH BTUH B H BTUH BTUH D yO a n
5 WALL CONSTRUCTION
6 TYPE OF GLASS J
F
7 CEILING CONSTRUCTION
r
t
8 FLOOR CONSTRUCTION 1
G
9 COLD PARTITION CONSTRUCTION HU T
10 JO ONE WA LL(WITH GLASS OR EXTERIOR DOOR)I `7
EQ TWOWALLS
F THREEWALLS OR ENTRANCE HALL " o la
11 TOTALBTUHAT70FTEMP.DIFFERENCE• D D
12 TOTALBTUH AT DESIGN TEMP.DIFFERENCE K— —
COL. A COL. B COL. H
r
COL. I COL. J COL. K COL. L L
1 ROOM y C L I,—
7 z o
O W W L W H L W H L W H L W H L W 4+
TOTAL BTUH TOTAL
2 ROOM DIMENSIONS, FT. U Q f 1 Z b 1 ' OF BUILDING RADIATION
3 LENGTH EXPOSED WALLS, FT. Q D AT SELECTED
i LL
Z DESIGN TEMP.
4 WINDOW AND OUTSIDE DOOR AREA DIFFERENCE
UH BTUH BTtTH BTUH BTUH
5 WALL CONSTRUCTION
6 TYPE OF GLASS
L
7 riQT
INCREASE BATHROOM
7 CEILING CONSTRUCTION
2
TOTAL20X
I!
8 FLOOR CONSTRUCTION 1
1 FOR CONCRETE FLOOR ON
i 9 COLD PARTITION CONSTRUCTION GROUND OR FILL AT GRADE
I LEVEL, USE LINEAR FEET
lO p ONE WALL(WITH GLASS OR EXTERIOR DOOR) j
OF EXPOSED EDGE
LL Q TWO WALLS Do
z
I THREEWALLS OR ENTRANCE HALL
11 TOTAL BTUH AT7OFTEMP.DIFFERENCE+ reo
12 TOTAL BTUH AT DESIGN TEMP.DIFFERENCE 2.0 1 0 FORM 1503
This form is available from The Hydronics Institute (Formerly The Institute of Boiler and Radiator Manufacturers) 35 Russo Place, Berkeley Heights, N.J.07922
Copyright 1965, by the Institute of Boiler and Radiator Manufacturers. Form 1503
ESTIMATE
QUANTITY ITEM AMOUNT
Boiler No. Net I=B=R Rating or Net SBI Rating*
Oil or Gas Burner or Stoker, with Controls
Oil Tank, Pipe and Fittings
Combustion Chamber or Stoker Hearth
Pump
Thermostat
Low Limit Control
Reverse Control
Extra Controls
Draft Regulator
Flow Control Valve
Pressure Reducing Valve
Relief Valve
Air Cushion Tank
Domestic Water Heater and Tank
Mixing Valve
Pipe, Valves, Fittings, Hangers
Pipe Covering
Heating Units (Radiators, Baseboards, Convectors)
Radiator Enclosures
Sets — Radiator Brackets
Radiator Valves
Radiator Union Elbows
Radiator Air Valves
Main Air Vents
Floor and Ceiling Plates
Smoke Pipe
Foundation
Electric Wiring
Pounds — Asbestos Cement
Paint
Freight and Cartage
Labor
Incidentals
Total Cost
Overhead
Profit
Bid
Net I=B=R Rating or Net SBI Rating of Boiler should equal or exceed the
total heat loss of the house plus proper allowance for domestic hot water
1
B=R CALCULATION SHEET 1503 Copyright 1965 by the Institute of Boiler and Radiator Manufacturers
OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE
COL. A COL. B COL. C COL. D COL. E COL. F COL. G ROOM
1 ROOM Ir
J^` TOTALS RADIATION
w —1OwwHLWHC' W H L W H L W H L W FROM LINE 12 SELECTED
2 ROOM DIMENSIONS, FT. O m Z
3 LENGTH EXPOSED WALLS, FT. Q 0 C b1'b Z_
Z
4 WINDOW AND OUTSIDE DOOR AREA 4'
BTUH BTUH BTUH BTUH BTUH D Ir
5 WALL CONSTRUCTION
E
6 TYPE OF GLASS
7 CEILING CONSTRUCTION
F
8 FLOOR CONSTRUCTION t G
9 COLD PARTITION CONSTRUCTION H
10 JO ONEWALL(WITH GLASS OR EXTERIOR DOOR)
1 Q TWO WALLS
THREEWALLS OR ENTRANCE HALL " J
11 TOTAL BTUHAT70FTEMP.DIFFERENCE* O0
12 TOTAL BTUH AT DESIGN TEMP.DIFFERENCE K
COL. A COL. B COL. H COL. I COL. J COL. K COL. L L
1 ROOM x 7 ydOWWHLWHLWHLWHLWHLW
2 ROOM DIMENSIONS, Fr.
t- O m TOTAL BTUH TOTAL
U ¢ 2 OF BUILDING RADIATION
3 LENGTH EXPOSED WALLS, FT. d Z AT SELECTED
4 WINDOW AND OUTSIDE DOOR AREA
IL DESIGN TEMP.
DIFFERENCE
BTUH BTUH BTUH BTUH BTUH
k 5 WALL CONSTRUCTION
Ili} 6 TYPE OF GLASS
7 CEILING CONSTRUCTION INCREASE BATHROOM
TOTAL 20%
8 FLOOR CONSTRUCTION t
f t FOR CONCRETE FLOOR ON
9 COLD PARTITION CONSTRUCTION GROUNDORFILLAT GRADE
LEVEL, USE LINEAR FEET
10 J ZO ONEWALL(WITH GLASS OR EXTERIOR DOOR) OF EXPOSED EDGE
FL~¢ TWO WALLS
z
THREEWALLS OR ENTRANCE HALL
11 TOTALBTUHAT70FTEMP.DIFFERENCE*
12 TOTAL BTUH AT DESIGN TEMP.DIFFERENCE
This form is available from The Hydronics Institute (Formerly The Institute of Boiler and Radiator Manufacturers) 35 Russo Place, Berkeley Heights, N.J.07922 FORM 1503
Copyright 1965, by the Institute of Boiler and Radiator Manufacturers.Form 1503
E S T I MATE
QUANTITY ITEM AMOUNT
Boiler No. Net 1=6=11 Rating or Net SBI Rating*
Oil or Gas Burner or Stoker, with Controls
Oil Tank, Pipe and Fittings
Combustion Chamber or Stoker Hearth
Pump
Thermostat
Low Limit Control
Reverse Control
Extra Controls
Draft Regulator
Flow Control Valve
Pressure Reducing Valve
Relief Valve
Air Cushion Tank
Domestic Water Heater and Tank
Mixing Valve
Pipe, Valves, Fittings, Hangers
Pipe Covering
Heating Units (Radiators, Baseboards, Convectors)
Radiator Enclosures
Sets — Radiator Brackets
Radiator Valves
Radiator Union Elbows
Radiator Air Valves
Main Air Vents
Floor and Ceiling Plates
Smoke Pipe
Foundation
Electric Wiring
Pounds — Asbestos Cement
Paint
Freight and Cartage
Labor
Incidentals
Total Cost
Overhead
Profit
Bid
Net I=B=R Rating or Net Sill Rating of Boiler should equal or exceed the
total heat loss of the house plus proper allowance for domestic hot wafer