HomeMy WebLinkAbout2 Robins Wayeec;-;c# 102 Y APPLICATION FOR BUILDING PERMIT
Plumbing# G 7? 2 Robin s Wood Way
HVAC # fl G f3 Dat : 10A Zoo27389
Spnkler#ri
FINAL APP VALS _
f Z
Estimated Cost $ /0Z
Building COMPLETE RED BOXED AREAS Permit Fee 1, 003
EngineeriEngineeringning TYPE OR PRINT ONLY Occupancy Fee $
Affidavit SIGN ON REVERSE SIDE
Appr.for CO.Total Fee 3 O
TO BUILDWG DEPARTMENT,TOWN OF SOUTH WINDSOR,CT Additional Cost) $
The undersigned h reby applies to do work according to the following specifications:
Job Location Z 12213 i N S W02 D WAY Lot No. Side of Street F:o Qone
Applicant r$14 R 13 A iZ A S 2A Tel.# Y6 o S'Z3 S`i—13
Address 2 V- L V JZ 3E z- S 1 /IA Z/ Gt-7 Zip 0 w Lic.#yt - ssr3
Own r j3A JZ 1'3,A ZA S PA Address S A/4i :'
Architect j: TJN`L' -Fou 1Z N I i R Address Z 21'5-1'® SyU v 1 N Go
Sq.Ft.New Area: 1st FI. 2?71 2nd FI. L714 F 3rd Fl. NJN S Total New Area 33 i 9'
Rooms Lavatories 2 Bathrooms 5 Garages 3 CA Q S
Purpose of this permit: Alew - tiA
City Water lam Well Septic System Sewe
Ins. H.O. S.P. Cert. Area 133/ 17 Basement Garage
Approved by 4(0--Date ( cx) Use Group IV Construction Type
Revi.d 1/97
1 h r by agree to conform to all the requirem nts of the Laws of th State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any afteration in the plans or specifications of the Building for which this
permit is asked,and agree that this building is to be located the proper distance from all street li ,side yard lines,and required
distances from all other zones and is located in which this buikfing and its use is allowed. bubscribed and &M toPublic, in and for County of
RK
Signed ;f c ,/Q v C*C,cy`-r1d State of nnect this.,,.L,,,....day ofIherebyapplyforaCertificateofOccupancyfortheworkdescribedinthisapplicat'wn
Signed l c
ta Notary,
DO NOT WRITE BELOW THIS LINE g' -• .... --
INSPECTION COMMENTS
Location of Job:AFFIDAVIT Additional Fee$ /00/
oa
State of Connecticut
ss.South Windsor
Coun of Hartford
Owner
1 6 L410,1 of 1/ NOOK, f-Agent for the building erected
Contractor
under Permit No. issued by the Building Department of th own of South Windsor being
duly sworn,make oath and say that the actual cost of the completed/work authorized under said permit did not
exceed the most current accepted BOCA value of S o20.3. O?c •
Signed c i
Subscribed and sworn to before me this 1 day of 6 A.D.20_
Estimated Cost S --,103_G 9. CM
R
Difference: $ 7 5
Notary Public
a
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
27389-B 100,000
B01 FOOTING 11/22/00 CJD A W/CONTRACTOR
B02 FOUNDATION 12/19/00 CJD A WATERPROOFING- SPRAYED OK
B05 FIREPLACE/CHIMNEY 05/03/01 CJD A W/MASON
B03 FRAMING (ROUGH) 06/08/01 CJD A W/OWNER
P02 UNDERGROUND 07/09/01 JFF A TEST W/ CONTRACTOR
E01 SERVICE 07/10/01 CJD A W/OWNER
B09 OTHER 07/16/01 CJD A LEFT FIELD CORR. NOTICE ON SIDING ISSUES.
E03 ROUGH 07/23/01 CJD A LEFT TICKET
P03 ROUGH 08/08/01 JFF A WITH CONTRACTOR NOTE 2ND FLOOR SOUTH BATH
NEEDS WINDOW OR MECH VENT
H03 ROUGH 08/20/01 CJD A W/OWNER
B04 INSULATION 08/27/01 GRM A W/HOMEOWNER
B10 FINAL 12/26/01 CJD D W/OWNERLGHT.ACTVN. AT BOT.STAIRS,INSUL.BSMT,
HSE.#'S,ILLUM.STAIRS,HNDRL.TOBSMT.,
B10 FINAL 03/19/02 CJD D SWTCH.BOT.BSMT.STRS. (2) ,SHTRCK.UNDR.STRS.BSMT
TEMP.GLASSFRNCH.DRS. ,CLST.LGHT. ,BND.HDRO.TUB
B10 FINAL 04/03/02 CJD A W/FLORIO
B10 FINAL 04/03/02 CJD A CLOSED OUT.
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
11043-H 15,000
10789-P 5,000
17285-E 6,500
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
27389-B 100,000
B01 FOOTING 11/22/00 CJD A W/CONTRACTOR
B02 FOUNDATION 12/19/00 CJD A WATERPROOFING- SPRAYED OK
B05 FIREPLACE/CHIMNEY 05/03/01 CJD A W/MASON
B03 FRAMING (ROUGH) 06/08/01 CJD A W/OWNER
P02 UNDERGROUND 07/09/01 JFF A TEST W/ CONTRACTOR
E01 SERVICE 07/10/01 CJD A W/OWNER
B09 OTHER 07/16/01 CJD A LEFT FIELD CORR. NOTICE ON SIDING ISSUES.
E03 ROUGH 07/23/01 CJD A LEFT TICKET
P03 ROUGH 08/08/01 JFF A WITH CONTRACTOR NOTE 2ND FLOOR SOUTH BATH
NEEDS WINDOW OR MECH VENT
H03 ROUGH 08/20/01 CJD A W/OWNER
B04 INSULATION 08/27/01 GRM A W/HOMEOWNER
B10 FINAL 12/26/01 CJD D W/OWNERLGHT.ACTVN. AT BOT.STAIRS,INSUL.BSMT,
HSE.#'S,ILLUM.STAIRS,HNDRL.TOBSMT.,
B10 FINAL 03/19/02 CJD D SWTCH.BOT.BSMT.STRS. (2) ,SHTRCK.UNDR.STRS.BSMT
TEMP.GLASSFRNCH.DRS.,CLST.LGHT. ,BND.HDRO.TUB
11043-H 15,000
10789-P 5,000
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
17285-E 6,500
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
27389-B 100,000
B01 FOOTING 11/22/00 CJD A W/CONTRACTOR
B02 FOUNDATION 12/19/00 CJD A WATERPROOFING- SPRAYED OK
B05 FIREPLACE/CHIMNEY 05/03/01 CJD A W/MASON
B03 FRAMING (ROUGH) 06/08/01 CJD A W/OWNER
P02 UNDERGROUND 07/09/01 JFF A TEST W/ CONTRACTOR
E01 SERVICE 07/10/01 CJD A W/OWNER
B09 OTHER 07/16/01 CJD A LEFT FIELD CORR. NOTICE ON SIDING ISSUES.
E03 ROUGH 07/23/01 CJD A LEFT TICKET
P03 ROUGH 08/08/01 JFF A WITH CONTRACTOR NOTE 2ND FLOOR SOUTH BATH
NEEDS WINDOW OR MECH VENT
H03 ROUGH 08/20/01 CJD A W/OWNER
B04 INSULATION 08/27/01 GRM A W/HOMEOWNER
B10 FINAL 12/26/01 CJD D W/OWNERLGHT.ACTVN. AT BOT.STAIRS,INSUL.BSMT,
HSE.#'S,ILLUM.STAIRS,HNDRL.TOBSMT. ,
B10 FINAL 03/19/02 CJD D SWTCH.BOT.BSMT.STRS. (2) ,SHTRCK.UNDR.STRS.BSMT
TEMP.GLASSFRNCH.DRS.,CLST.LGHT. ,BND.HDRO.TUB
11043-H 15,000
10789-P 5,000
17285-E 6,500
Total Est Value 126,500
Dwelling 3,319 160,241.32
Basement 2,114 30,018.80
Garage 867 12,311.40
Smoke Det 7 525.00
BOCA Value 203,096.52 n
Difference 76,596.52
C
l
SITE COMPLIANCE CHECKLIST
pTOWNofSOUTHWINDSOR, CONNECTICUT
2 Robin's Wood Way LOT_# 1 Reviewed
ByPSIEPAI(
E ineering)
BARBARA SUDA Date Reviewed 01. p rove enied
25 ELVREE STREET,MANCHESTER,CT Reviewed By lanning)
BP_##_27389_ Ph # 523-5513 Date Reviewed Crpprove enied
Date Submitted 00/00/00 FOR C of 0 *
As required in the Zoning and/or Subdivison Regulations, no Certificate of
Occupancy shall be issued until grading plans have been complied with and
approved by the Town Engineer. The minimum requirements shall include:
Approved Denied N/A
1. Approved building permit plan
2. Finish ,grading;per approved
building permit plan
1 3. Site work; i.e. trees, shrubs,
dumpsters, required parking
4. Utility location;
a. sanitary sewer/septic system
fb. foundation drain vij;A j
C. electrical & telephone
d. water
e. other
5. Sewer connection charge paid
6. Appropriate certification
1 7. Bonding
8. Planning & Zoning/
Inland Wetlands Considerations
A. Lighting
B. Signage
Freestanding Wall
C. Fee in lieu of Open Space
Sewer Permit No. 130
Pavement Excavation No.
COMMENTS:
1 N1( iQ llDl SF.EL lV E'/J.,
A
Tio O-PSau ?d&1d4kAciv
f:
ti 1540 SULLIVAN AVENUE SOUTH WINDSOR, CT 06074
soR.co' TELEPHONE(860) 644-2511
April 4, 2002
CERTIFIED MAIL 7000 1670 0001 8922 0694
Barbara or Florian Suda
25 Elvree Street
Manchester, CT 06040
Dear Barbara or Florian Suda,
We have reviewed your request for a Certificate of Occupancy for 2 Robins's Wood Way. This
request is approved with the condition that you must post a $2,500.00 bond to cover the
completion of the outstanding item that is listed below.
1. Complete Land Grading and Turf Establishment.
I understand you plan to complete this item this spring and summer. I expect it to be done
within six months of the date of this letter. Extensions of the deadline may only be granted by
the Town Engineer, if it is clearly shown that a good faith effort was made to complete this work,
but the work was not completed due to circumstances beyond your control. When this item is
complete, please call the Engineering office for a follow up inspection and release of the bond.
A copy of this letter is enclosed for you to sign and return to our office acknowledging yourreceiptoftheseconditions. Please call the Engineering office at 644-2511 x 244 if you needfurtherassistance.
Sincerely,
J rey B. Doolittle, P.E. J ff F6k6r
Town Engineer Environmental anner
By signing below, I acknowledge, and agree to the amount, conditions, and time frame set bythisletterforthisbond.
Printed Name Signature Date
cc: Marcia Banach, Director of Planning
John Collins, Chief Building Official V/
SITE COMPLIANCE CHECKLIST
TOWN of SOUTH WINDSOR, CONNECTICUT
2 Robin's Wood Way LOT_# 1 Reviewed By -S• RAr En ineerin )
BARBARA SUDA Date Reviewed O 00 prov
25 ELVREE STREET,MANCHESTER,CT Reviewed By14T It lannin )
BP # 27389 Ph_# 523-5513 Date Reviewed u a-o r
Date Submitted 10/16/00 F B1 ILD NG ERMIT &U**,--
VG4-p>-2 a83 V15f Il Is
In accordance wih the Zoning and/or Subdivisi gula ions, prior to the
building of any structure on a lot, a Topographic Plot Plan shall be submitted
for approval. The minimum requirements shall include:
Approved Deni d N/A
1. Name, address & phone number of owner/applicant
2. Name, address & phone number of plan preparer
3. Zoning Information - i.e. zone, open space,
floodway, street address.
4. Plot Plan at 1" Iscale
a. Subdivision reference, abutting properties, etc
b. Easements of record
C. Lot description, bearings,building lines,
distances, area, etc.
LAM,AS f-W 09Wj*XL
d. Contours, existing & proposed, 1 or 2 ft.
interval where appropriate
e. Building location with dimensions.
Elevations of proposed finish floor, garage
floor & centerline of road at driveway
f. Elevations of gravity drainage systems, sanitary
foundation drain at the house and the street
g. Tentative utility location (gas, water,
electric, septic system, etc.)
TV-/cn-c v
h. Title block with name and address of preparer,
date, appropriate certification, live seal and live
signature consistent with the Board of Registration
requirements. (P.E. & L.S.)
000"' 97LQuirID
5. Sedimentation and erosion control
1! 6. Special Planning & Zoning, Inland/Wetlands
considerations (Plans on file w/Town Clerk)
COMMENTS:
r,µow LlfArr of 1CX:>-q(L FLVVP "' 0 P99- MAA?
UyjW;? A4P TR.AVV-- 2A-%1AWT -T 4£ r+aoi lEfl Dv-r ,cis-ri oWv ''
4
MA? AA" EAsEM%NT pof.u^^4 rAOS 1e F)(ID
OCTJ 1 .7 2000
LkaL, 9Z9;'!' C -AjE9-s , .PTS A s E P-o PJ ;JS -,o Brt- 3iT. 'OIL i
y
v oU1DE 'DjrYX 5So*JS Mores $Gobs. CVKA. -S ?o ER LJI S • %0000' SOILWI =
DEPE
0 .r 141J)Y JWef- LA ,50-AL M'I~• xo
5wow GGroAJ--o(JTS Evf-94f d -
C l.ASS A-Zr Kcu"1-1 grwafj) D T-of- 9G0-% pc.AAjS gb uw .Qcrc
sf4( '
9
co
U T-au 0
m 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074
R•CU AREA CODE 203/644-2511pSO
Memo to: John Collins
Chief Building Inspector
From: Charles Danna
Assistant Assessor
Date: May 4, 1990
Re: Robin Wood Way - Private drive
Mailing Address rGl
The owners of property served by Robin Wood Way, a private drive,
have requestedthe town address their properties as being a
location on Robin Wood Way rather than the Foster Street address
references now in effect. Unless there is serious objection
to this request, the following shall be in effect for future
use for town purposes:
940 Foster Street shall be 2 Robin Wood Way
950 Foster Street shall be 6 Robin Wood Way
970 Foster Street shall be 10 Robin Wood Way
Charles Danna
Assistant Assessor 0
CC: M. Banach, Planning
W. Lanning, Fire Department
Capt. Guilini, Police Department
T. Cortese, Postmaster, US Postal Service
DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT
TOWN OF SOUTH WINDSOR
PERMIT#
Applica '
BUILDING DEPARTMENT FF S
APPROVED 1540 SULLIVAN AVENUE Bldg.Permit#
644-2511 ext. 230
Date Buil g Inspector
Application must be printed or typed
FEE SCHEDULE Location of Job:
o AWS k%,o-,z,0k M414 Z 0+ I
0-$1,000=$13.00 Street No. Street Lot No.
Over$1,000=
13.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT
APPLICANT ADDRESS
fy1 h - U motto
Y
APPLICANT PHONE#
OWN St OWNER 41
OWNER ADDRESS a f-L j 2e-c
fY\A K .j'l o
O wit s° OWNER PHONE
C ESTIMATED COST$ &SW, 0D -
A IS THIS A CONTRACT COST? Yes No
a
FEE ENCLOSED$
C//.
o a
OR C0 TYPE OF JOB:
eew Installation
Alteration/Addition/Repair Revised 5101
Y
APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A
RESIDENTIAL
BUILDING PERMIT APPLICATION? YES NO
BUSINESS CURRENT USE AND OCCUPANCY
ASSEMBLY
MERCANTILE FUTURE USE AND OCCUPANCY
EDUCATIONAL
INSTITUTIONAL ENGINEER'S NAME PHONE
FACTORY
STORAGE ADDRESS
GARAGE
MIXED USE CITY STATE ZIP
TYPE OF INSTALLATION/WIRING METHOD
SIZE OF SERVICE '26b SIZE OF MAIN CONDUCTORS q
NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS
NUMBER OF PANELS r REMOTE DISCONNECT REQUIRED? YES NO
NUMBER OF LIGHT CIRCUITS _NUMBER OF POWER CIRCUITS cp
NUMBER OF SWITCHES NUMBER OF OUTLETS 5S
NUMBER OF LIGHT FIXTURES , NUMBER OF HEAT CIRCUITS I
NUMBER OF A/C CIRCUITS /
SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED.
DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
I r o (. Z- ) cl:::I-k
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICANT A DATE r f 0
Page 1 of 1
John Collins - CRS Approval Confirmation: Request No. 175676
From: <clpsvc@nu.com>
To: COLLIN@SOUTHWINDSOR.ORG>
Date: 7/17/2001 2:19 PM
Subject: CRS Approval Confirmation: Request No. 175676
CRS Work Request#:175676
House No: 2 k 4f4`c5 oc+
Lot No:
Street Name:
Inspector: JOHN COLLINS
Approval Date: Jul 17,2001
file://CADocuments and Settings\Administrator\Local Settings\Temp\GW}00004.HTM 7/18/2001
t
DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT#
Application is hereby:TOWN OF SOUTH WINDSOR Q BUILDING DEPARTMENT
APPROVED 1540 SULLIVAN AVENUE Bldg.Permit#
644-2511 ext. 230 a 3
ate Building Inspector
Application must be printed or typed
L ation of Job:
FEE SCHEDULE
0 4
0-$1,000=$13.00 Street No. Street
No.
No.
Over$1,000=
13.00 per$1,000
or any fraction thereof Tenant Designation A
APPLICANT
APPLICANT ADDRESS
J,e4va U
APPLICANT PHONE#
N S OWNER 5!
q OWNER ADDRESS
i
e
s OWNER PHONE
Q Ems' o
C ESTIMATED COST$
U
IS THIS A CONTRACT COST? s 0 No°
FEE ENCLOSED$ lG
SpR.CO
TYPE OF JOB:
NeQInstallation
0 Alteration/Addition/Repair Revised 8/99
APPLICATION FOR PLUMBING PERMIT (Continued from reverse side)
TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A
4 BUILDING PERMIT APPLICATION?A?'VVS NO
M SIDENTIAL
BUSINESS CURRENT USE AND OCCUPANCY
ASSEMBLY
MERCANTILE FUTURE USE AND OCCUPANCY
EDUCATIONAL
INSTITUTIONAL ENGINEER'S NAME PHONE
FACTORY
STORAGE ADDRESS
GARAGE
MIXED USE CITY STATE ZIP
Other please specify)
TYPE OF INSTALLATION RoLt C411C.j"N IU SIZE OF MAIN DRAIN
NO.OF TOILETS_ STYLE URINALS STYLE
NO.OF BATHTUBS NO.OF SHOWERS C;?. NO.OF LAVATORIES
NO.OF CONDUCTORS SIZE NO.OF STACKS 4 SIZE
AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS
NO.OF OTHER FIXTURES KIND
ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW YES NO
SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR
a
0
SIZE OF DUCTS SEWER OR SEPTIC TANK
r
SIZE OF WATER MAIN f ! SIZE OF WATER PIPING&RISER
WATER HEATER: TYPE MANUFACTURER
DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
c2 79 F13 LT-
CONTRACTORS LICENSE NO. STATE
SIGNATURE OF APPLICANT DATE 4!'—
DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
PERMIT#
Application is hereby:TOWN OF SOUTH WINDSOR
BUILDING DEPARTMENT
ROVED 1540 SULLIVAN AVENUE Bldg.Permit#
D
644-2511 ext. 230 7 3 q
D to Building Inspector
1
Application must be printed or typed
FEE SCHEDULE
ocation of Job:
Ah SA
0-$1,000=$13.00 Street No. Street Lot No.
Over$1,000=
13.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
I
APPLICANT vi-ax j ks fn
APPLICANT AD1§RESS lcm
Wn i
APPLICANT PHONE#
n
0* N S OWNER )ne)
q
J b
OWNER ADDRESS
r
T "
L. OWNER PHONE
ESTIMATED COST$
IS THIS A CONTRACT COST? 0 Yes No
CJ FEE ENCLOSED$
TYPE 7BInstallationw
0 Alteration/Addition/Repair Revised 8/99
Ff
if
f
AP LICATION FOR HVAC PERMIT (Continued from reverse side
TYPE OF S M: TYPE OF B DING:
ATING SIDENTIAL
A/C COMMERCIAL
VENTILATION INDUSTRIAL
HEATING
STEAM LOW PRE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
HYDRONIC WARM AIR UNIT RADIANT HEATER
EXISTING RADIATION EADDITIONAL RADIAMN TOTAL RADIATI
DESIGN TEMP. OUTSIDE F INSIDE &ee °F DIFFERENCE F
TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION) I
DE CRIB ALL HEA(IQ E UIPNT NCLUDING ODEL N
A 6 0.
GROSS HEAT G CAPACITY(INPUT-BTUH T RATING(OUTPUT-BTUH)
TYPE OF EL I
OIL-GPM OIL TANK LOCATION :INSIDE OUTSIDE CAPACITY
GAS-INPUT LPG TANK CAPACITY ELECTRIC-KW
AIR CONDITIONING I
DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE 1 OF
TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
TONNAGE C® COOLING CAPACITY(BTUH)
VENTILATION
UKIBEvALLL IR HANDLING E UIPMENT(INCCLUD G KITCMEXHAUST EQUIPMENT)
C
TOTAL SIZE OF SYSTEM(CFM)aqn FRESH AIR INTAKE(CFM)
PLANS MUST ACCOMPANY APPLICATION)
THER DESCRIP ON OF ORK J
t
TH UNDERSI D HEREBY APPLIES FO PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
CONTRACTORS LIC SE N E TATE
C
SIGNATURE OF APPLICA DATE
RIGHT-J SHORT FORM
Entire House
Project Information
For: FLORIAN &BARBARA SUDA
Design Information
Htg Clg Infiltration
Outside db (OF) 6 88 Method Simplified
Inside db (OF) 70 75 Construction quality Average
Design TD (OF)64 13 Fireplaces 0
Daily range M
Inside humidity(%) 50
Moisture difference (gr/lb) - 28
HEATING EQUIPMENT COOLING EQUIPMENT
Make Make
Trade Trade
Efficiency 80.0 AFUE Efficiency 0.0 EER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Heating temperature rise 0 OF Total cooling 0 Btuh
Actual heating fan 2676 cfm Actual cooling fan 2676 cfm
Heating air flow factor 0.020 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh
Space thermostat Load sensible heat ratio 86 %
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
ft2) Btuh) Btuh) cfm) cfm)
1 ST FLOOR n p 1951 85086 42767 1680 2287
ZONE#3 n p 667 22303 7847 440 420
2ND FLOOR n p 855 28125 10479 555 560
Entire House d 3473 135514 50044 2676 2676
Ventilation air 0 0
Equip. @ 0.93 RSM 46541
Latent cooling 8038
TOTALS 3473 135514 54579 2676 2676
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wrightsoft Right-Suite ResidentialTM 5.0.28 RSR27402 2001-Apr-12 11:25:06
A(,CX Projectl.rsr Page 1
Ir
RIGHT-J SHORT FORM
1ST FLOOR
Project Inf•
For: FLORIAN &BARBARA SUDA
Design Information
Htg Clg Infiltration
Outside db(OF) 6 88 Method Simplified
Inside db (OF) 70 75 Construction quality Average
Design TD (OF)64 13 Fireplaces 0
Daily range M
Inside humidity(%) 50
Moisture difference(gr/lb) - 28
HEATING EQUIPMENT COOLING EQUIPMENT
Make n/a Make n/a
Trade n/a Trade n/a
n/a n/a
n/a
Efficiency n/a Efficiency n/a
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Heating temperature rise 0 OF Total cooling 0 Btuh
Actual heating fan 0 cfm Actual cooling fan 0 cfm
Heating air flow factor 0.000 cfm/Btuh Cooling air flow factor 0.000 cfm/Btuh
Space thermostat n/a Load sensible heat ratio 0 %
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
ft2) Btuh) Btuh) cfm) cfm)
FOYER 168 10952 5739 216 307
LIVING ROOM 109 6761 3365 134 180
BATH/ENTRY 60 5154 2363 102 126
DINETTE 126 6979 4409 138 236
KITCHEN 247 7131 5042 141 270
FAMILY ROOM 333 15925 8627 314 461
MASTER BEDROOM 271 10711 4849 212 259
MASTER BATH 196 5917 2480 117 133
WIC 210 6103 1346 121 72
DINING ROOM 231 9452 4547 187 243
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wrightsoft Right-Suite ResidentialTM 5.0.28 RSR27402 2001-Apr-12 11:25:06
CC Projectl.rsr Page 2
1ST•FLOOR n p 1951 85086 42767 1680 2287
Ventilation air 0 0
Equip. @ 0.93 RSM 39774
Latent cooling 5968
TOTALS 1951 85086 45742 1680 2287
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wrightsoft Right-Suite Residential*"'5.0.28 RSR27402 2001-Apr-12 11:25:06
4CCX Projectl.rsr Page 3
RIGHT-J SHORT FORM
2ND FLOOR
Project Information
For: FLORIAN & BARBARA SUDA
Design Information
Htg Clg Infiltration
Outside db(OF) 6 88 Method Simplified
Inside db(OF) 70 75 Construction quality Average
Design TD (OF)64 13 Fireplaces 0
Daily range M
Inside humidity(%) 50
Moisture difference(gr/lb) - 28
HEATING EQUIPMENT COOLING EQUIPMENT
Make n/a Make n/a
Trade n/a Trade n/a
n/a n/a
n/a
Efficiency n/a Efficiency n/a
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Heating temperature rise 0 OF Total cooling 0 Btuh
Actual heating fan 0 cfm Actual cooling fan 0 cfm
Heating air flow factor 0.000 cfm/Btuh Cooling air flow factor 0.000 cfm/Btuh
Space thermostat n/a Load sensible heat ratio 0 %
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
ft2) Btuh) Btuh) cfm) cfm)
BEDROOM#4 175 5862 2392 116 128
BEDROOM#3 271 11696 4699 231 251
BEDROOM#2 169 6257 2541 124 136
BATH#1 25 440 87 9 5
BATH#2 72 1284 253 25 14
UPPER FOYER 144 2586 509 51 27
2ND FLOOR n p 855 28125 10479 555 560
Ventilation air 0 0
Equip. @ 0.93 RSM 9746
Latent cooling 1330
TOTALS 855 28125 11076 555 560
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wnghtSoft Right-Suite Residential TM 5.0.28 RSR27402 2001-Apr-12 11:25:06
CCX Projectl.rsr Page 5
RIGHT-J SHORT FORM
ZONE #3
Project Information
For: FLORIAN &BARBARA SUDA
Design • . •
Htg Clg Infiltration
Outside db (OF) 6 88 Method Simplified
Inside db(OF) 70 75 Construction quality Average
Design TD (°F)64 13 Fireplaces 0
Daily range M
Inside humidity(%) 50
Moisture difference(gr/lb) - 28
HEATING EQUIPMENT COOLING EQUIPMENT
Make n/a Make n/a
Trade n/a Trade n/a
n/a n/a
n/a
Efficiency n/a Efficiency n/a
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Heating temperature rise 0 OF Total cooling 0 Btuh
Actual heating fan 0 cfm Actual cooling fan 0 cfm
Heating air flow factor 0.000 cfm/Btuh Cooling air flow factor 0.000 cfm/Btuh
Space thermostat n/a Load sensible heat ratio 0 %
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
ft2) Btuh) Btuh) cfm) cfm)
UNFINISHED STORE 667 22303 7847 440 420
ZONE#3 n p 667 22303 7847 440 420
Ventilation air 0 0
Equip. @ 0.93 RSM 7298
Latent cooling 739
TOTALS 667 22303 8037 440 420
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wrightsoft Right-Suite Residentiai rm 5.0.28 RSR27402 2001-Apr-12 11:25:06
4CCK Projectl.rsr Page 4
RIGHT-J BUILDING ANALYSIS REPORT
Entire House
Project Information
For: FLORIAN &BARBARA SUDA
Design Information
Htg Clg Infiltration
Outside db)F) 6 88 Method Simplified
Inside db (° 70 75 Construction quality Average
Design TD (OF)64 13 Fireplaces 0
Daily range M
Inside humidity(%) 50
Moisture difference(gr/lb) - 28
Heating
Wall Duds
Component Btuh/ft2 Btuh %of load
Walls 5.8 17628 13.0 Windows--
f
Windows 35.3 18866 13.9 Infiltration
Doors 0.0 0 0.0
Ceilings 5.6 19561 14.4
Floors 10.0 34676 25.6 Ceilings
Infiltration 50.7 27107 20.0 Floors
Ducts 17676 13.0
Total
Cooling
Component Btuh/ft2 Btuh %of load Wall Internal Gains
Walls 1.5 4572 9.1
Windows 35.2 18832 37.6 Duds
Doors 0.0 0 0.0
Ceilings 3.1 10666 21.3
Floors 0.0 0 0.0 Windows Infiltration
Infiltration 5.9 3146 6.3
Ducts 6528 13.0
Internal gains 6300 12.6 mailings
Total 50044 100.0
Cooling at 86%SHR=4.5 ton Cooling air flow=588 cfm/ton
Cooling at 70 %SHR=5.5 ton Cooling at 400 cfm/ton =6.7 ton
Overall U-Value=0.186 Btuh/ft2-°F
Data entries checked.
wrightsoft Right-Suite ResidentialTM 5.0.28 RSR27402 2001-Apr-12 11:25:05
CCK Projectl.rsr Page 1
RIGHT-J BUILDING ANALYSIS REPORT
1ST FLOOR
Project Inf•
For: FLORIAN &BARBARA SUDA
Design Information
Htg Clg Infiltration
Outside db F) 6 88 Method Simplified
Inside db(° ) 70 75 Construction quality Average
Design TD (°F)64 13 Fireplaces 0
Daily range M
Inside humidity(%) 50
Moisture difference(gr/lb) - 28
Heating
Wall Ducts
Component Btuh/ft2 Btuh %of load
Walls 5.8 10353 12.2 Windows
Windows 35.3 13612 16.0 Infiltration
Doors 0.0 0 0.0
Ceilings 5.6 10988 12.9
Floors 10.0 19478 22.9 ceilings
Infiltration 50.7 19557 23.0
Ducts 11098 13.0
Total 1 1 85086 100.0
Cooling
Component Btuh/ft2 Btuh %of load Walls Internal Gains
Walls 1.5 2685 6.3
Windows 35.2 13587 31.8
Doors 0.0 0 0.0 Dui
Ceilings 3.1 5991 14.0
Floors 0.0 0 0.0 Windows
Infiltration 5.9 2270 5.3 Infiltrat1on
Ducts 4445 10.4
Internal gains 5100 11.9 Ceilings
Total 1 340791 79.7
Cooling at 88 %SHR=3.8 ton Cooling air flow=600 cfm/ton
Cooling at 70% SHR=4.7 ton Cooling at 400 cfm/ton = 5.7 ton
Overall U-Value= 0.190 Btuh/ft2-°F
Data entries checked.
wrightSoft Right-Suite ResidentialTM 5.0.28 RSR27402 2001-Apr-12 11:25:05
m Projectl.rsr Page 2
RIGHT-J BUILDING ANALYSIS REPORT
2ND FLOOR
Project Inf•
For: FLORIAN & BARBARA SUDA
Design Information
Htg Clg Infiltration
Outside db 6 88 Method Simplified
Inside db(0 OF)) 70 75 Construction quality Average
Design TD (OF)64 13 Fireplaces 0
Daily range M
Inside humidity(%) 50
Moisture difference(gr/lb) - 28
Heating
Wall Ducts
Component Btuh/ft2 Btuh %of load
Walls 5.8 3969 14.1 Windows___ Infiltration
Windows 35.3 2927 10.4
Doors 0.0 0 0.0
Ceilings 5.6 4817 17.1
Floors 10.0 8539 30.4 Ceilings
Infiltration 50.7 4205 15.0 Floors
Ducts 3668 13.0
Total 1 28125 100.0
Cooling
Component Btuh/ft2 Btuh %of load Walls Internal Gains
Walls 1.5 1029 9.8 Ducts
Windows 35.2 2922 27.9
Doors 0.0 0 0.0
Ceilings 3.1 2626 25.1 WirKIO InfiltrationS
Floors 0.0 0 0.0
Infiltration 5.9 488 4.7
Ducts 1195 11.4
Internal gains 900 8.6 Ceilings
Total 9160 87.4
Cooling at 89% SHR=0.9 ton Cooling air flow=607 cfm/ton
Cooling at 70% SHR= 1.2 ton Cooling at 400 cfm/ton = 1.4 ton
Overall U-Value=0.181 Btuh/ft2-°F
WARNING:window to floor area ratio=9.7%-less than 10%.
wrightsoft Right-Suite Residential""5.0.28 RSR27402 2001-Apr-12 11:25:05
ZC Projectl.rsr Page 3
r
RIGHT-J BUILDING ANALYSIS REPORT
ZONE #3
Project I •
For: FLORIAN & BARBARA SUDA
Design Information
Htg Clg Infiltration
Outside db r)F) 6 88 Method Simplified
Inside db(° 70 75 Construction quality Average
Design TD ( F)64 13 Fireplaces 0
Daily range M
Inside humidity(%) 50
Moisture difference(gr/lb) - 28
HeatingMORI
Wall Ducts
Component Btuh/ft2 Btuh %of load
Walls 5.8 3306 14.8 Windows- Infiltration
Windows 35.3 2327 10.4
Doors 0.0 0 0.0
Ceilings 5.6 3757 16.8
Floors 10.0 6659 29.9 Ceilings
Infiltration 50.7 3344 15.0 Floors
Ducts 2909 13.0
Total 22303 100.0
Cooling
Component Btuh/ft2 Btuh %of load Wall Internal Gains
Walls 1.5 858 10.9
Djcft
Windows 35.2 2323 29.6 InfiltrationDoors0.0 0 0.0
Ceilings 3.1 2048 26.1
Floors 0.0 0 0.0 Windom
Infiltration 5.9 388 4.9
Ducts 888 11.3 Ceilings
Internal gains 300 3.8
Total 6805 86.7
Cooling at 91 %SHR=0.7 ton Cooling air flow=627 cfm/ton
Cooling at 70% SHR=0.9 ton Cooling at 400 cfm/ton = 1.0 ton
Overall U-Value=0.180 Btuh/ft2-°F
WARNING:window to floor area ratio=9.9%-less than 10%.
wrightsoft Right-Suite ResidentialTM 5.0.28 RSR27402 2001-Apr-12 11:25:05
AC0, Projecti sr Page 4