HomeMy WebLinkAbout2 Karen WaySictric#1464f 5 APPLICATION FOR BUILDING PERMIT
Plumbing# qg6 2 KAREN WAY
HVAC # U,fA Date:
Sprinkler# NO' 2 2 9 7 7
FINAL PPR Estimated Cost $ 6 S DDO
Building COMPLETE RED BOXED AREAS Permit Fee 4 G.5'0
Engines in TYPE OR PRINT ONLY Occupancy Fee $ 3
Affidavit SIGN ON REVERSE SIDE
Appr.for CO. ff 1 Total Fee 5^
TO BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR,CT Additional Cost) $361
Th and rsigned hereby applies to do work according to the following specifications:
Job Location 44 kAX6,^1 `1/A Lot No. 3 Side of Street Zone fR
Applicant Cr/1/V C..Sjj&CX f Tel. # jg!K¢ —.3,'/3
Address o?.S f"ie .OAV. Zip 496!2U Lic.#
Owner e aRo5it,Sytll GKt Address ,j 5"-/ W'0Ilt1 GtR ,OAO CSO, I,,//j.0 S c'>R.
Archit ct Address
Sq. Ft. N w Area: 1st FI. 3 3 S 2nd FI. 3rd Fl. Total New Area Jj S o
Rooms Lavatories — Bathrooms 3 Garages
Purpose of this permit: 442 AE A-A/"Of L y Q!GLGi/ly
City Water d Well D Septic System Sewer V
Use Group Construction Type .5Q Area f / Basem t 3f q 3 Garage U
Approved by J Date O_A6
Revised 6/95
I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of
South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this
permit is asked, and agree that this building is to be located the proper distance from all street lines,side yard lines and required
distances from all other zones and is located in a zone in which this budding and its use is allowed.r
Signed ZAOO
I hereby apply for a Certificate of Occupancy for the work described in this application for the permit
i
Signed
DO NOT WRIT BELOW THIS LINE --
INSPECTION COMMENTS
Location of Job: AFFIDAVIT Additional Fee S -3 Co. 0,3
State of Connecticut
ss.South Windsor
County of Hartford
caner
I ,L/t/Y ,l.Pigsn//';<<of Agent for the building erected
Contractor
under Permit No. 7 7 issued by the Building Department of the Town of South Windsor being
duly sworn,make oath and say that the actual cost of the completed work authorized under said permit did not
exceed the most current accepted BOCA value of S Z/!j-j30-2-3
Signed
Subcribed and sworn to before me this /1 7k day of SPA 1 5 A.D. 1957
Estimated Cost S J 00
Difference: $ ¢.3, z
Notary Public
Inspection / Approval Date By Appl
Code Description Due Whom Code Comment
96-22977-B 165,000
B01 FOOTING 05/13/96 JFH A BACK HALF
B01 FOOTING 05/14/96 JFF A WE
EAST HALF OF FOOTING
B02 FOUNDATION 06/13/96 JFF A
P02 UNDERGROUND 09/13/96 JFF A
B05 FIREPLACE/CHIMNEY 09/17/96 JFF A CELLAR THROAT ONLY NEED ADDITIONAL INSPT 1ST
FLOOR
E01 SERVICE 09/17/96 JFF A NOTIFIED NU
B05 FIREPLACE/CHIMNEY 09/19/96 JFF A FIRST FLOOR
B03 FRAMING (ROUGH) 03/21/97 JFH A
P03 ROUGH 03/21/97 JFH A
E03 ROUGH 03/21/97 JFH A
B04 INSULATION 04/15/97 JFF A WALLS ONLY EXPOSED VAPOR BARRIER IN CELLAR
NOTIFIED CONTRACTOR
B10 FINAL 07/30/97 JFF D GARAGE GFI-S/CHIMNEY FLU/GROUNDWIRE WATER
METER/HOUSE NUMBERS
B10 FINAL 07/31/97 JFF A APPROVED FOR CO BLDG
96-9804-P 9,000
96-9616-H 10,000
96-14098-E 1,000
Total Est Value 185,000
Dwelling 3,443 140,887.56
Basement 3,443 42,693.20
Garage 810 10,044.00
Smoke Det 7 525.00
BOCA Value 219,389.23
Difference 34,389.23 l/ j1eA- .
v
SITE COMPLIANCE CHECKLIST J
TOWN of SOUTH WINDSOR, CONNECTICUT Bf
2 KAREN WAY LOT_# 3 Reviewed B E inee 'n )
KRASNICKI HENRY Date Reviewed 91121,V71
25-1 ARTHUR DRIVE,SOUTH WINDSOR,CT Reviewed By n
s BP #_22977_ Ph # (860) 644-3713 Date Review Approve i
Date Submitted 08/12/97 FOR C of O ***
As required in the Zoning and/or Subdivison Regulations, no Certificate of
Occupancy shall be issued until grading plans have been complied with and
approved by the Town Engineer. The minimum requirements shall include:
Approved Denied N/A
J 1. Approved building permit plan
2. Finish grading per approved
building permit plan
3. Site work; i.e. trees, shrubs,
dumpsters, required parking
4. Utility location;
a. sanitary sewer/septic system
b. foundation drain
C. electrical & telephone
d. water
e. other
5. Sewer connection charge paid
6. Appropriate certification
7. Bonding
8. Planning & Zoning/
Inland Wetlands Considerations
Sewer Permit NO. (2LI"T O
Pavement Excavation No.
COMMENTS:
c
on iul-M er nil
r)
t0000,
7. _
SITE COMPLIANCE CHECKLIST
TOWN of SOUTH WINDSOR, CONNECTICUT
2 KAREN WAY LOT-# 3 Reviewed Engineering)
KRASNICKI HENRY Date
ReviewedVIM25-1 ARTHUR DRIVE,SOUTH WINDSOR,CT Reviewed By Planning)
BP # 22977 Ph # (860)644-3713 Date Revi PPDateSubmitted03/14/96 FORIT
In accordance with the Zoning and/or Subdivision Regulations, prior to the
building of any structure on a lot, a Topographic Plot Plan shall be submitted k
for approval. The minimum requirements shall include:
AppA v Denied
1. Name, addre phone numb of owner/applicant
2. Name, address & phone number of plan preparer
3. Zoning Information - i.e. zone, open space,
floodway, etc.
4. Plot Plan at 1" = 40' scale
a. Subdivision reference, abutting properties, etc.
b. Easements of record
c. Lot description, bearings, building lines,
distances, area, etc.
d. Contours, existing & proposed, 1 or 2 ft.
interval where appropriate
e. Building location with dimensions.
Elevations of proposed finish floor, garage
floor & centerline of road at driveway
f. Elevations of gravity drainage systems, sanitary
foundation drain at the house and the street
off' g. Tentative utility location (gas, water,
electric, septic system, etc.)r
h. Title block with name and address of preparer,
date, appropriate certification, live seal and live
signature consistent with the Board of Registration
requirements. (P.E. & L.S.)
y(
5. Sedimentation and erosion control kAWZ-aM1
6. Special Planning & Zoning, Inland/Wetlands
considerations (Plans on file w/Town Clerk)
11
COMMENTS: c,,.SIXQ-' 'r d UA-4J1
ILL_XA—*o V
PERMIT
DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT
Application is hereby : TOWN OF SOUTH WINDSOR
BUILDING INSPECTION DEPT.
APPROVED DISAPPROVED 1540 SULLIVAN AVENUE
644-2511 Ext. 230
D t it g Inspector Application must be printed or typed
1 . LOCATION OF JOB
z KA,16 `y
No . Street
FEE SCHEDULE
Floor Apt . No.
0 - $19000 - 10.00
el
r r
Ov r $19 000 -10.00 2 . OWNER l/`
per $1 ,000 or
fraction thereof 3. ADDRESS
c 11`rJ D 5c,P t0A11 V
4, APPLICANT
Lv5 . ADDRESS fL' L,0Ule l
6. ESTIMATED COST $ I 0,0 Z
7 . IS THIS A CONTRACT COST V
Yee No
8 . FEE ENCLOSED $ /0 d c)
9 . TYPE OF BUILDING:
VRESIDENTIAL COMMERCIAL
10. TYPE OF JOB:
Original Installation
Alteration/Addition/Repair
RD 3A 11/88
APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side)
11 . LOCATION OF JOB C// v L/
r
NO . STREET APT. NO ,
12 . TYPE OF INSTALLATION
13 . SIZE OF MAIN FEEDER 2 D,n A J 1 - 0A2YO V
14 . NO . OF LIGHT LOOPS4-_LQ_ 15 . NO. OF HEAT LOOPS
16 . NO . OF POWER LOOPSj_jD 17 . NO. OF LIGHT OUTLETS _
18 . NO . OF HEAT CIRCUITS 19 . NO. OF POWER OUTLETS 1
20 . NO. OF CONVENIENCE OUTLETS '2Z C) 21. NO. OF HEAT CIRCUITS
Z
22 . NO ,, OF POWER CIRCUITS-CZ / () 23. NO. OF LIGHT CIRCUIT-5
24. SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS
26 . N0 . OF PANELS C/iC 27 . TOTAL WATTAGE
28 . NO . OF POWER FEEDERS 29 . NO. OF SWITCHES f _
30 . A/C LOAD AV04 7Zc7!/ 31. SIZE OF POWER FEEDERS 20 -1,1'1Q4
32 . NO . OF FIXTURES- Z 33. TOTAL HORSEPOWER
34 . NAME OF SUBCONTRACTORS AND THEIR TRADES
P //L 0 G/Ap C 6- A- 0/ 91 7-s- cTrr--
35 . REMARKS AND FURTHER DETAILS :
log q7-- 94
LICENSE NO .SIGNATURE OF APPLICANT DATE
PHONE NUMBER:
a
PERMIT NO.
9-
DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT
Application is hereby :TOWN OF SOUTH WINDSOR
APPROVED DISAPPROVED
BUILDING INSPECTION DEPT.
1540 SULLIVAN AVENUE
el
644-2511 Ext. 230
a e Inspector Applications must be printed or typed
1. LOCATION OF JOB:
Z— KA 9-,g v.,/ LA,)o 1i LOT 5
FEE SCHEDULE 2. OWNER: a!1 1
3. ADDRESS: 4 Q,`'h
0 - $1 ,000 - 10.00
10.o
v ba C
Over $1 ,000 - 0
per $1 ,000 or 4. APPLICANT: y r
fraction thereof
5. ADDRESS:
g d V("6 N r` Q.7
6. EST. COST: $
7. IS THIS A CONTRACT COST? YES _a0O
8. FEE ENCLOSED: $ a 0
29?7
9. TYPE OF BUILDING:
N_RESIDENTIAL COMMERCIAL
10. TYPE OF JOB:
ORIGINAL ALTERATION
INSTALLATION ADDITION
REPAIR
BD 2A 11/88
APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side)
11. LOCATION OF JOB: L4,'A "j
GENERAL PLUM NG
12. KIND OF INSTALLATION: 13. SIZE OF MAIN DRAIN 504 qj)
14. NO. OF TOILETS __STYLE .6 15. NO. OF URINALS STYLE
16. NO. OF BATHTUBS 3 16A. NO. OF SHOWERS 17. NO. OF LAVATORIES
18. NO. OF SINKS 19. DISPOSAL_ 19A. DISWASHER !
20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS t-SIZE 3 h
22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS
25. NO. OF OTHER FIXTURES KIND
26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW?
27. SIZE OF WINDOW
28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE?
29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK?
L 31. SIZE OF WATER MAIN 1 ^ 31A. SIZES OF WATER PIPING & RISERS ,-) d-- a+
32. REMARKS AND FURTHER DETAILS
WATER HEATER
33. TYPE 34. MANUFACTURER
TANKS SAFETY DEVICES
TEMPERATURE
35. CAPACITY 39. RELIEF VALVE
36. TEST PRESSURE LBS. 40. MANUFACTURER
37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE
38. TYPE 42. MANUFACTURER
LICENSE NO. ATE IGNATURE OF APPLICANT
PHONE NO.a %--
DEPARTMENT DECISION
RNUT:9
APPLICATION FOR HVAC PERMIT
P
61L A
Application is hereby: TOWN of SOUTH WINDSOR
Bldg Permit#BUILDING DEPARTMENT 7
APPROVE 1540 SULLIVAN AVENUE
644-2511 ext. 230
2
f IIDate Building Inspector Application must be printed or typed
Location ofjob
Street No. Street' Lot No.
FEE SCHEDULE
Floor Apt.No.
0 - $1,000 - $12.00
Over $1,000
Street
12.00 per$1,000 OWNER 54.2L e--
or any fraction thereof
ADDRESS---..2.5-- Z?X
e 15 014P C r -- A6 014
OWNERS PHONE# 644 -37 /3
APPLICANT 7
c 0*
ADDRESS
4(
ESTIMATED COST $0 C
IS THIS A CONTRACT COST?
YES NO
FEE ENCLOSED $ )ILO hl
TYPE OF JOB:OR-C Ll original Installation
Alteration/Addition/Repair
Revised 11/95
APPLICATION FOR HVAC PERMIT(Continued from reverse side)
TYPE OF SYSTEM TYPE OF BUILDING
HEATING RESIDENTIAL ,k
A/C COMMERCIAL
VENTILATION INDUSTRIAL
HEATING
STEAM LOW PRESSURE LIMIT LBS.HIGH PRESSURE LIMIT LBS.
HYDRONIC WARM AIR_4 UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE_-5- F INSIDE IZ F DIFFERENCE o 8F
TOTAL HEAT LOSS(BTUH) 6 c U
HEAT LOSS SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE&MODEL NO.)
GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH)
Gco
TYPE OF FUEL
OIL-GPM GAS-INPUT ELECTRIC-KW AIAI Z/o sn'
OIL TANK SIZE&LOCATION 341000
INSIDE OUTSIDE CAPACITY LPG TANK CAPACITY
S J
r
AIR CONDITIONING
DESIGN TEMP. OUTSIDE 9O F INSIDE7J F DIFFERENCE 1-5- F
TOTAL HEAT GAIN(BTUH) 5-3-//6,0
HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE&MODEL NO.)
TONNAGE COOLING CAPACITY(BTUH),O D
VENTILATION
DESCRIBE ALL AIR HANDLING E UIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT),
ch e
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) 2,00
PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK .?_O 0 0 L, iO;._ ?Ic/ j -4 1,fres
i r.S.C,L•e- d-- .Pig,o= I Oy4 C 1/L lr' .M
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN. BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
S ATE LICENSE-NO. NAME&TYPE IGNAOtRE017 APPLICANT
PHONE NO. DATE i/
Apr
70
r
s /
w
RESIDENCE
MR. & MRS. HENRY KRASNICKI
21 KAREN WAY
SOUTH WINDSOR, CT. 06074
PHONE: 860 644 3713
PREPARED BY
NORM TWITCHELL & ASSOCIATES
16 STEVENS STREET
WINDSOR LOCKS, CT. 06096
PHONE: 860 623 2318
NORM TWITCHELL & ASSOCIATES PROJECT: New Residence
16 STEVENS STREET CLIENT: Mr. & Mrs. Henry Krasni
WINDSOR LOCKS, CT 06096 DATE: July 25, 1996
RESIDENTIAL/LIGHT COMMERCIAL HVAC LOADS DESIGNER:Norman P. Twitchell
CLIENT INFORMATION:
NAME: Mr. & Mrs. Henry Krasnicki
ADDRESS: 25-1 Arthur Drive
CITY, STATE: South Windsor
TOTAL BUILDING LOADS:
BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAL
DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN
3-D WINDOW DBL PN LOW EMIT WOOD FR 426 10, 303 0 13,810 13 ,810
9-J FRENCH DOOR DBL LOW E WOOD FR 134 31071 0 51476 5,476
12-K WALL R-19 +111EXTRPOLY BRD(R-5.0) 2,139 6 ,446 0 11789 11789
13-K PART R-19 +111EXTRPOLY BRD(R-5.0) 874 11319 0 394 394
11-A DOOR METAL FIBERGLASS CORE 60 21373 0 657 657
16-H CEILING R-38 INSULATION 21473 4, 307 0 2 ,508 21508
18-F ROOF+CEIL R-30 BATTS(2X10 RAFTR) 459 1,076 0 627 627
19-D FLOOR/ENCL CRAWL HARDWD + R-19 871 1,516 0 0 0
19-I FLOOR/ENCL CRAWL CARPET + R-19 203 326 0 0 0
20-D FLOOR/OPEN CRAWL HARDWD + R-19 1, 858 6,473 0 967 967
21-A BASEMT FLOOR 2'OR> BELOW GRADE 454 730 0 0 0
SUBTOTALS FOR STRUCTURE: 9,951 37,940 0 261F228 26 , 228
PEOPLE 26 0 51980 71800 13 ,780
APPLIANCES 0 0 1,200 11400 2,600
DUCTWORK 0 41798 0 31694 3,694
INFILTRATION W.CFM: 136 .3 S.CFM: 90.9 0 10,048 21163 1,500 3 ,663
VENTILATION W.CFM: 136. 3 S.CFM: 136. 3 0 10,048 3 ,245 2,250 5,495
SENSIBLE GAIN TOTAL 42,872
TEMP. SWING MULTIPLIER X 1.00
BUILDING LOAD TOTALS 62 , 832 12 ,588 42 , 872 55,460
LOAD SUMMARY FOR ZONE #1
SUPPLY CFM AT 20 DEG DT: 614 CFM PER SQUARE FOOT: 0.545
SQUARE FT. OF ROOM AREA: 1 ,127 SQUARE FOOT PER TON: 733. 525
TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 18.641 MBH
TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 1.536 TONS
RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096
New Residence July 25, 1996 PAGE 2
BUILDING LOADS (CONTINUED) *************************
LOAD SUMMARY FOR ZONE #2
SUPPLY CFM AT 20 DEG DT: 11048 CFM PER SQUARE FOOT: 0.616
SQUARE FT. OF ROOM AREA: 1,702 SQUARE FOOT PER TON: 642.749
TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 35.135 MBH
TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 2.648 TONS
LOAD SUMMARY FOR ZONE #3
SUPPLY CFM AT 20 DEG DT: 185 CFM PER SQUARE FOOT: 0. 332
SQUARE FT. OF ROOM AREA: 557 SQUARE FOOT PER TON: 1, 274. 357
TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 9.055 MBH
TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 0.437 TONS
TOTAL BUILDING LOAD SUMMARY
SUPPLY CFM AT 20 DEG DT: 11847 CFM PER SQUARE FOOT: 0. 545
SQUARE FT. OF ROOM AREA: 3 ,386 SQUARE FOOT PER TON: 732.636
TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 62 .832 MBH
TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 4.622 TONS
CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J.
ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY.
BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS.
RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096
New Residence July 25, 1996 PAGE 3
TOTAL ZONE LOADS FOR ZONE # 1 ***********************
BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAL
DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN
3-D WINDOW DBL PN LOW EMIT WOOD FR 98 21370 0 41928 4 , 928
9-J FRENCH DOOR DBL LOW E WOOD FR 54 1, 237 0 2,916 21916
12-K WALL R-19 +111EXTRPOLY BRD(R-5.0) 722 2,175 0 603 603
16-H CEILING R-38 INSULATION 11127 11963 0 11143 11143
19-D FLOOR/ENCL CRAWL HARDWD + R-19 117 204 0 0 0
20-D FLOOR/OPEN CRAWL HARDWD + R-19 1,010 3 ,519 0 525 525
SUBTOTALS FOR STRUCTURE: 3 ,128 11,468 0 10, 115 10,115
PEOPLE 6 0 11380 11800 31180
APPLIANCES 0 0 11200 0 1,200
DUCTWORK 0 11392 0 1,229 11229
INFILTRATION W.CFM: 33 .4 S.CFM: 22. 3 0 2,463 530 368 898
VENTILATION W.CFM: 45. 0 S.CFM: 45.0 0 31318 11072 743 1 ,815
SENSIBLE GAIN TOTAL 14,255
TEMP. SWING MULTIPLIER X 1.00
BUILDING LOAD TOTALS 18,641 41182 14, 255 18,437
SUPPLY CFM AT 20 DEG DT: 614 CFM PER SQUARE FOOT: 0.545
SQUARE FT. OF ROOM AREA: 1,127 SQUARE FOOT PER TON: 733 .525
TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 18.641 MBH
TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 1.536 TONS
CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J.
ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY.
BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS.
RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096
New Residence July 25, 1996 PAGE 4
TOTAL ZONE LOADS FOR ZONE # 2 ***********************
BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAL
DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN
3-D WINDOW DBL PN LOW EMIT WOOD FR 286 6 ,919 0 71496 71496
9-J FRENCH DOOR DBL LOW E WOOD FR 40 917 0 11240 11240
12-K WALL R-19 +111EXTRPOLY BRD(R-5.0) 941 21836 0 788 788
13-K PART R-19 +111EXTRPOLY BRD(R-5.0) 240 362 0 108 108
11-A DOOR METAL FIBERGLASS CORE 60 21373 0 657 657
16-H CEILING R-38 INSULATION 11243 21165 0 11261 1, 261
18-F ROOF+CEIL R-30 BATTS(2X10 RAFTR) 459 11076 0 627 627
19-D FLOOR/ENCL CRAWL HARDWD + R-19 651 1, 133 0 0 0
19-I FLOOR/ENCL CRAWL CARPET + R-19 203 326 0 0 0
20-D FLOOR/OPEN CRAWL HARDWD + R-19 848 2,954 0 442 442
SUBTOTALS FOR STRUCTURE: 41971 21,061 0 12 ,619 12 ,619
PEOPLE 20 0 4 ,600 61000 10,600
APPLIANCES 0 0 0 11400 11400
DUCTWORK 0 2,732 0 2,095 2,095
INFILTRATION W.CFM: 84.9 S.CFM: 56.6 0 61256 11347 934 2, 281
VENTILATION W.CFM: 69.0 S.CFM: 69.0 0 5,088 1,643 11139 21782
SENSIBLE GAIN TOTAL 24,187
TEMP. SWING MULTIPLIER X 1 . 00
BUILDING LOAD TOTALS 35,135 71590 24,187 31,777
SUPPLY CFM AT 20 DEG DT: 11048 CFM PER SQUARE FOOT: 0.616
SQUARE FT. OF ROOM AREA: 1,702 SQUARE FOOT PER TON: 642.749
TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 35.135 MBH
TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 2 .648 TONS
CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J.
ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY.
BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS.
RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096
New Residence July 25, 1996 PAGE 5
TOTAL ZONE LOADS FOR ZONE # 3 ***********************
BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAL
DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN
3-D WINDOW DBL PN LOW EMIT WOOD FR 42 11014 0 11386 11386
9-J FRENCH DOOR DBL LOW E WOOD FR 40 917 0 1, 320 11320
12-K WALL R-19 +111EXTRPOLY BRD(R-5.0) 476 11435 0 398 398
13-K PART R-19 +1"EXTRPOLY BRD(R-5.0) 634 957 0 286 286
16-H CEILING R-38 INSULATION 103 179 0 104 104
19-D FLOOR/ENCL CRAWL HARDWD + R-19 103 179 0 0 0
21-A BASEMT FLOOR 2'OR> BELOW GRADE 454 730 0 0 0
SUBTOTALS FOR STRUCTURE: 11852 51411 0 31494 31494
PEOPLE 0 0 0 0 0
APPLIANCES 0 0 0 0 0
DUCTWORK 0 674 0 370 370
INFILTRATION W.CFM: 18. 0 S.CFM: 12.0 0 1 , 329 286 198 484
VENTILATION W.CFM: 22. 3 S.CFM: 22. 3 0 1,641 530 367 897
SENSIBLE GAIN TOTAL 4,429
TEMP. SWING MULTIPLIER X 1. 00
BUILDING LOAD TOTALS 9,055 816 4,429 5,245
SUPPLY CFM AT 20 DEG DT: 185 CFM PER SQUARE FOOT: 0. 332
SQUARE FT. OF ROOM AREA: 557 SQUARE FOOT PER TON: 1, 274. 357
TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 9.055 MBH
TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 0.437 TONS
CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J.
ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY.
BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS.
RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096
New Residence July 25, 1996 PAGE 6
MISCELLANEOUS PROJECT DATA *************************
DESIGN CONDITIONS: WINTER SUMMER
OUTDOOR DRY BULB TEMPERATURE 5 DEG.F 90 DEG.F
INDOOR DRY BULB TEMPERATURE - ZONE 1 72 DEG.F 75 DEG.F
INDOOR DRY BULB TEMPERATURE - ZONE 2 72 DEG.F 75 DEG.F
INDOOR DRY BULB TEMPERATURE - ZONE 3 72 DEG.F 75 DEG.F
DESIGN TEMPERATURE DIFFERENCE - ZONE 1 67 DEG.F 15 DEG.F
DESIGN TEMPERATURE DIFFERENCE - ZONE 2 67 DEG.F 15 DEG.F
DESIGN TEMPERATURE DIFFERENCE - ZONE 3 67 DEG.F 15 DEG.F
INDOOR-OUTDOOR GRAINS DIFFERENCE 35 GRAINS
OUTDOOR DAILY TEMPERATURE RANGE MED
GENERAL PROJECT DATA:
PROJECT DATA FILE NAME: C:\RHVAC\KRASNICK
TOTAL GROSS WALL AREA (SF) : 3 ,633 . 00
NON-GLASS DOOR AREA (SF) : 60.00
TOTAL NET GLASS AREA (SF) : 560. 00
TOTAL SKYLIGHT AREA (SF) : 0.00
TOTAL NET WALL AREA (SF) : 31013 . 00
TOTAL NET ROOF AREA (SF) : 21932.00
TOTAL EXPOSED AREA (SF) : 6,565.00
PEOPLE LATENT LOAD MULTIPLIER: 230.00
PEOPLE SENSIBLE LOAD MULTIPLIER: 300. 00
LATITUDE DEGREES: 41.00
TEMPERATURE SWING MULTIPLIER: 1. 00
EXTERNAL SHADING TYPES:
NO. OVERHANG OFFSET
1. 0.0 0.0
2 . 0.0 0.0
3 . 0. 0 0.0
4. 0.0 0.0
5. 0.0 0. 0
6. 0 .0 0.0
7. 0.0 0.0
OUTSIDE AIR DATA: WINTER SUMMER
INFILTRATION AIR CHANGES PER HOUR: 0. 300 0. 200
CUBIC FEET OF CONDITIONED SPACE: X 27, 267 X 27, 267
81180 5,453
X 0.0167 X 0.0167
TOTAL BUILDING INFILTRATION CFM: 136. 3 90. 9
TOTAL BUILDING VENTILATION CFM: 136.0 136 .0
INFIL. & VENT. SEN. GAIN MULTIPLIER: 16.50 = (1.10 X 15 SUMMER TEMP. DIFF. )
INFIL. & VENT. LAT. GAIN MULTIPLIER: 23 .80 = (0.68 X 35 GRAINS DIFFERENCE)
INFIL. & VENT. SEN. LOSS MULTIPLIER: 73.70 = (1.10 X 67 WINTER TEMP. DIFF. )
RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096
New Residence July 25, 1996 PAGE 7
DETAILED ROOM LOADS * ***************************
ITEM AREA -U-HTG SEN. CLG LAT. SEN.
DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN
1. MASTER BEDROOM 16.0 WID X 22.0 LEN = 352 SF CEIL.HT = 8.0
SE-WALL-12K 8 X 16 74 0. 045 3. 0 223 0. 8 0 62
S -WALL-12K 8 X 6 48 0.045 3 .0 145 0.8 0 40
SW-WALL-12K 8 X 2 16 0.045 3 .0 48 0. 8 0 13
SE-G.DR-9J 2-P 0-0 S-1 0%S 54 0. 342 22.9 11237 54.0 0 2,916
CEIL-16H DARK 22 X 16 352 0.026 1.7 613 1. 0 0 357
FLOOR-20D 22 X 16 352 0.052 3 .5 11226 0.5 0 183
INFIL. W: 11. 9 S: 7. 9 54 16. 2 875 2 .4 188 131
DUCTWORK 0.100 437 0.100 0 430
PEOPLE 2 230 300 460 600
ROOM TOTALS 4,804 648 41732
2. WALK-IN-CLOSET 5.5 WID X 7. 2 LEN =40 SF CEIL.HT = 8.0
S -WALL-12K 8 X 7.2 58 0 .045 3 .0 175 0.8 0 49
SE-WALL-12K 8 X 1. 3 10 0.045 3.0 30 0. 8 0 8
CEIL-16H DARK 7. 2 X 5.5 40 0.026 1 .7 70 1.0 0 41
FLOOR-20D 7. 2 X 5.5 40 0. 052 3.5 139 0.5 0 21
INFIL. W: 0.0 S: 0.0 0 16. 2 0 2.4 0 0
DUCTWORK 0.100 41 0. 100 0 12
ROOM TOTALS 455 0 131
3. MASTER BATH 12 .7 WID X 13 .7 LEN = 174 SF CEIL.HT = 8. 0
SE-WALL-12K 8 X 13 .7 98 0 .045 3 .0 295 0 .8 0 82
SE-WALL-12K 8 X 12.7 90 0. 045 3.0 271 0. 8 0 75
SE-GLAS-3D 2-P 0-0 S-1 0%S 12 0.361 24.2 290 54.0 0 648
SE-GLAS-3D 2-P 0-0 S-1 0%S 12 0. 361 24.2 290 54. 0 0 648
CEIL-16H DARK 13 .7 X 12.7 174 0.026 1.7 303 1.0 0 176
FLOOR-20D 13 .7 X 12.7 174 0. 052 3.5 606 0.5 0 90
INFIL. W: 5. 3 S: 3 .5 24 16 . 2 389 2.4 84 58
DUCTWORK 0.100 244 0.100 0 178
APPLIANCES 11200 0
ROOM TOTALS 2,688 1,284 1,955
RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096
New Residence July 25, 1996 PAGE 8
DETAILED ROOM LOADS *****************************
ITEM AREA -U-HTG SEN. CLG LAT. SEN.
DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN
4. BATH #1 5.0 WID X 13 .7 LEN =69 SF CEIL.HT = 8 .0
E -WALL-12K 8 X 5 32 0. 045 3. 0 96 0. 8 0 27
E -GLAS-3D 2-P 0-0 S-1 0%S 8 0. 361 24.2 193 63 .0 0 504
CEIL-16H DARK 13 .7 X 5 69 0. 026 1.7 120 1.0 0 70
FLOOR-19D 13 .7 X 5 69 0.052 1 .7 120 0.0 0 0
INFIL. W: 1. 8 S: 1. 2 8 16. 2 130 2.4 28 19
DUCTWORK 0 .100 66 0.100 0 62
ROOM TOTALS 725 28 682
5. BEDROOM #1 12 .0 WID X 13 .0 LEN = 156 SF CEIL.HT = 8.0
E -WALL-12K 8 X 12 76 0. 045 3 . 0 229 0.8 0 64
NW-WALL-12K 8 X 13 84 0.045 3 .0 253 0.8 0 70
E -GLAS-3D 2-P 0-0 S-1 0%S 20 0.361 24.2 484 63. 0 0 11260
NW-GLAS-3D 2-P 0-0 S-1 100%S 20 0. 361 24. 2 484 44.0 0 880
CEIL-16H DARK 13 X 12 156 0. 026 1.7 272 1. 0 0 158
FLOOR-20D 13 X 12 156 0.052 3 .5 544 0.5 0 81
INFIL. W: 8.8 S: 5. 9 40 16.2 648 2.4 140 97
DUCTWORK 0 .100 291 0 .100 0 321
PEOPLE 2 230 300 460 600
ROOM TOTALS 31205 600 3,531
6. BEDROOM #2 12.5 WID X 13 .2 LEN = 165 SF CEIL.HT = 8. 0
NW-WALL-12K 8 X 13 . 2 86 0.045 3 .0 259 0.8 0 72
W -WALL-12K 8 X 2 16 0. 045 3.0 48 0. 8 0 13
NW-GLAS-3D 2-P 0-0 S-1 100%S 20 0. 361 24. 2 484 44.0 0 880
CEIL-16H DARK 13.2 X 12 .5 165 0.026 1.7 287 1.0 0 167
FLOOR-20D 13 .2 X 12 .5 165 0.052 3 .5 575 0.5 0 86
INFIL. W: 4.4 S: 2 .9 20 16. 2 324 2 .4 70 48
DUCTWORK 0.100 198 0.100 0 187
PEOPLE 2 230 300 460 600
ROOM TOTALS 2,175 530 2,053
RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096
New Residence July 25, 1996 PAGE 9
DETAILED ROOM LOADS *****************************
ITEM AREA -U-HTG SEN. CLG LAT. SEN.
DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN
7. BATHROOM #2 5.0 WID X 9.6 LEN =48 SF CEIL.HT = 8 .0
N -WALL-12K 8 X 5 34 0. 045 3 . 0 103 0. 8 0 28
N -GLAS-3D 2-P 0-0 S-1 0%S 6 0. 361 24.2 145 18.0 0 108
CEIL-16H DARK 9.6 X 5 48 0. 026 1.7 84 1.0 0 49
FLOOR-19D 9.6 X 5 48 0.052 1.7 84 0.0 0 0
INFIL. W: 1. 3 S: 0. 9 6 16. 2 97 2. 4 21 15
DUCTWORK 0 .100 51 0.100 0 20
ROOM TOTALS 564 21 220
8. BEDROOM HALL 4.9 WID X 25.0 LEN = 123 SF CEIL.HT = 8.0
CEIL-16H DARK 25 X 4. 9 123 0. 026 1.7 214 1. 0 0 125
FLOOR-20D 25 X 4.9 123 0.052 3 .5 429 0.5 0 64
INFIL. W: 0. 0 S: 0.0 0 16. 2 0 2 .4 0 0
DUCTWORK 0.100 64 0 .100 0 19
ROOM TOTALS 707 0 208
9. LIVING ROOM 14.9 WID X 17.0 LEN = 253 SF CEIL.HT = 8.0
E -WALL-12K 8 X 3 . 9 31 0.045 3 . 0 93 0. 8 0 26
N -WALL-12K 8 X 15 81 0 .045 3 .0 244 0.8 0 68
N -GLAS-3D 2-P 0-0 S-1 0%S 30 0. 361 24. 2 726 18. 0 0 540
N -GLAS-3D 2-P 0-0 S-1 0%S 9 0.361 24.2 218 18.0 0 162
CEIL-16H DARK 17 X 14. 9 253 0.026 1.7 441 1.0 110 257
FLOOR-20D 17 X 14.9 253 0.052 3 .5 881 0.5 0 132
INFIL. W: 8.6 S: 5.7 39 16.2 632 2.4 136 94
DUCTWORK 0.100 324 0.100 0 308
PEOPLE 6 230 300 11380 11800
ROOM TOTALS 3 ,559 1,516 3, 387
RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096
New Residence July 25, 1996 PAGE 10
DETAILED ROOM LOADS ********** ******************
ITEM AREA -U-HTG SEN. CLG LAT. SEN.
DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN
10. FRONT FOYER 10. 3 WID X 12.0 LEN = 124 SF CEIL.HT = 11.4
N -WALL-12K 11.4 X 10.4 48 0.045 3 .0 145 0.8 0 40
N -DOOR-11A 6.8 X 3 20 0.590 39.5 791 11. 0 0 219
N -DOOR-11A 6.8 X 3 20 0.590 39.5 791 11.0 0 219
N -GLAS-3D 2-P 0-0 S-1 0%S 8 0. 361 24.2 193 18. 0 0 144
N -GLAS-3D 2-P 0-0 S-1 0%S 8 0 . 361 24. 2 193 18.0 0 144
N -GLAS-3D 2-P 0-0 S-1 0%S 15 0. 361 24. 2 363 18.0 0 270
CEIL-16H DARK 12 X 10.3 124 0.026 1.7 216 1.0 0 126
FLOOR-19D 12 X 10. 3 124 0.052 1.7 216 0. 0 0 0
INFIL. W: 15.6 S: 10.4 71 16 .2 11151 2.4 248 172
DUCTWORK 0.100 406 0.100 0 133
ROOM TOTALS 4,465 248 1,467
11. POWDER ROOM-FRONT 4. 0 WID X 6.9 LEN =28 SF CEIL.HT = 0. 0
CEIL-16H DARK 6.9 X 4 28 0 .026 1.7 49 1.0 0 28
FLOOR-19D 6.9 X 4 28 0. 052 1.7 49 0. 0 0 0
INFIL. W: 0.0 S: 0.0 0 16.2 0 2.4 0 0
DUCTWORK 0. 100 10 0.100 0 3
ROOM TOTALS 108 0 31
12. STUDY 11.9 WID X 11.4 LEN = 136 SF CEIL.HT = 8.0
S -WALL-12K 8 X 9 52 0 .045 3 .0 157 0 .8 0 44
E -WALL-12K 8 X 2 16 0. 045 3 .0 48 0. 8 0 13
S -GLAS-3D 2-P 0-0 S-1 0%S 20 0 . 361 24.2 484 31.0 0 620
CEIL-16H DARK 11.4 X 11.9 136 0. 026 1.7 237 1. 0 0 138
FLOOR-20D 11.4 X 11.9 136 0.052 3 .5 474 0.5 0 71
INFIL. W: 4.4 S: 2. 9 20 16. 2 324 2 .4 70 48
DUCTWORK 0.100 172 0.100 0 153
PEOPLE 2 230 300 460 600
ROOM TOTALS 11896 530 1,687
RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096
New Residence July 25, 1996 PAGE 11
DETAILED ROOM LOADS *****************************
ITEM AREA -U-HTG SEN. CLG LAT. SEN.
DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN
13 . FAMILY ROOM 11.0 WID X 41.7 LEN = 459 SF CEIL.HT = 8.0
S -WALL-12K 11. 3 X 50 393 0. 045 3 . 0 11185 0. 8 0 329
E -WALL-12K 11.3 X 2 23 0 .045 3.0 69 0.8 0 19
W -WALL-12K 11. 3 X 2 23 0. 045 3 . 0 69 0. 8 0 19
S -GLAS-3D 2-P 0-0 S-1 0%S 20 0.361 24.2 484 31.0 0 620
S -GLAS-3D 2-P 0-0 S-1 O%S 20 0. 361 24.2 484 31. 0 0 620
S -GLAS-3D 2-P 0-0 S-1 0%S 20 0. 361 24. 2 484 31.0 0 620
S -GLAS-3D 2-P 0-0 S-1 0%S 20 0. 361 24. 2 484 31. 0 0 620
S -GLAS-3D 2-P 0-0 S-1 0%S 20 0.361 24.2 484 31.0 0 620
S -GLAS-3D 2-P 0-0 S-1 0%S 20 0. 361 24. 2 484 31.0 0 620
S -G.DR-9J 2-P 0-0 S-1 O%S 40 0.342 22.9 917 31.0 0 1, 240
S -GLAS-3D 2-P 0-0 S-1 0%S 12 0. 361 24. 2 290 31. 0 0 372
ROOF-18F DARK 41.7 X 11 459 0.035 2 .3 11076 1.4 0 627
FLOOR-20D 41.7 X 11 459 0. 052 3 .5 11599 0.5 0 239
INFIL. W: 37.8 S: 25.2 172 16 . 2 21787 2.4 600 416
DUCTWORK 0.100 11090 0.100 0 878
PEOPLE 6 230 300 11380 11800
ROOM TOTALS 11,986 11980 91659
14. POWDER ROOM - REAR 6.0 WID X 5.5 LEN =33 SF CEIL.HT = 8.0
SW-WALL-12K 8 X 5. 5 38 0. 045 3. 0 115 0.8 0 32
SW-GLAS-3D 2-P 0-0 S-1 O%S 6 0. 361 24.2 145 54.0 0 324
CEIL-16H DARK 5.5 X 6 33 0.026 1.7 57 1.0 0 33
FLOOR-19D 5.5 X 6 33 0.052 1.7 57 0.0 0 0
INFIL. W: 1. 3 S: 0. 9 6 16. 2 97 2.4 21 15
DUCTWORK 0.100 47 0 .100 0 40
ROOM TOTALS 518 21 444
RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096
New Residence July 25, 1996 PAGE 12
DETAILED ROOM LOADS *****************************
ITEM AREA -U-HTG SEN. CLG LAT. SEN.
DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN
15. KITCHEN 16. 2 WID X 21.0 LEN = 340 SF CEIL.HT = 8.0
S -WALL-12K 8 X 6.2 38 0.045 3 .0 115 0.8 0 32
SW-WALL-12K 8 X 10 80 0. 045 3. 0 241 0. 8 0 67
NW-PART-13K 8 X 11 88 0.045 1.5 133 0.5 0 40
S -GLAS-3D 2-P 0-0 S-1 0%S 12 0. 361 24. 2 290 31. 0 0 372
CEIL-16H DARK 21 X 16. 2 340 0.026 1.7 592 1.0 0 345
FLOOR-19D 21 X 16.2 340 0. 052 1.7 592 0.0 0 0
INFIL. W: 2.6 S: 1.8 12 16 .2 194 2.4 42 29
DUCTWORK 0.100 216 0.100 0 229
APPLIANCES 0 11400
ROOM TOTALS 21373 42 21514
16 . MUDROOM 7.0 WID X 18.0 LEN = 126 SF CEIL.HT = 8.0
NW-PART-13K 8 X 7 56 0.045 1. 5 84 0. 5 0 25
W -PART-13K 8 X 12 96 0.045 1.5 145 0.5 0 43
W -WALL-12K 8 X 5 20 0. 045 3 . 0 60 0. 8 0 17
W -DOOR-11A 6.7 X 3 20 0.590 39.5 791 11.0 0 219
CEIL-16H DARK 18 X 7 126 0.026 1.7 219 1.0 0 128
FLOOR-19D 18 X 7 126 0.052 1.7 219 0.0 0 0
INFIL. W: 4.4 S: 2 . 9 20 16.2 324 2.4 70 48
DUCTWORK 0.100 184 0.100 0 48
ROOM TOTALS 21026 70 528
17. LAUNDRY 8.6 WID X 12.0 LEN = 103 SF CEIL.HT = 8.0
S -WALL-12K 8 X 8.5 68 0. 045 3.0 205 0. 8 0 57
N -PART-13K 8 X 8.5 68 0.045 1.5 103 0.5 0 31
W -PART-13K 8 X 12 96 0. 045 1.5 145 0.5 0 43
CEIL-16H DARK 12 X 8.6 103 0.026 1.7 179 1.0 0 104
FLOOR-19D 12 X 8.6 103 0.052 1 .7 179 0.0 0 0
INFIL. W: 0.0 S: 0.0 0 16.2 0 2.4 0 0
DUCTWORK 0.100 81 0.100 0 24
ROOM TOTALS 892 0 259
RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096
New Residence July 25, 1996 PAGE 13
DETAILED ROOM LOADS *****************************
ITEM AREA -U-HTG SEN. CLG LAT. SEN.
DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN
18 . LOWER REC. ROOM 18.9 WID X 24.0 LEN = 454 SF CEIL.HT = 8 .0
E -PART-13K 12 X 14 86 0.045 1.5 130 0.5 0 39
W -PART-13K 12 X 14 168 0.045 1.5 253 0 .5 0 76
N -PART-13K 12 X 18 216 0.045 1.5 326 0.5 0 97
S -WALL-12K 12 X 34 408 0 .045 3 .0 11230 0.8 0 341
E -GLAS-3D 2-P 0-0 S-4 0%S 7 0. 361 24.2 169 33. 0 0 231
E -GLAS-3D 2-P 0-0 S-4 0%S 7 0. 361 24.2 169 33 .0 0 231
E -GLAS-3D 2-P 0-0 S-4 0%S 7 0. 361 24. 2 169 33 . 0 0 231
E -GLAS-3D 2-P 0-0 S-4 0%S 7 0.361 24.2 169 33 .0 0 231
E -GLAS-3D 2-P 0-0 S-4 0%S 7 0. 361 24. 2 169 33 . 0 0 231
E -GLAS-3D 2-P 0-0 S-4 0%S 7 0.361 24.2 169 33 .0 0 231
E -G.DR-9J 2-P 0-0 S-4 0%S 40 0. 342 22. 9 917 33 . 0 0 11320
FLOOR-21A 24 X 18 .9 454 0.024 1.6 730 0.0 0 0
INFIL. W: 18.0 S: 12. 0 82 16. 2 11329 2 .4 286 198
DUCTWORK 0 .100 593 0.100 0 346
ROOM TOTALS 61522 286 31803
19. DINING ROOM 14.5 WID X 14.0 LEN = 203 SF CEIL.HT = 8 .0
N -WALL-12K 8 X 14.5 70 0.045 3.0 211 0.8 0 59
E -WALL-12K 8 X 3 .5 28 0.045 3 .0 84 0.8 0 23
N -GLAS-3D 2-P 0-0 S-1 0%S 35 0. 361 24.2 847 18. 0 0 630
N -GLAS-3D 2-P 0-0 S-1 0%S 11 0.361 24. 2 266 18.0 0 198
CEIL-16H DARK 14 X 14.5 203 0. 026 1.7 354 1.0 0 206
FLOOR-19I 14 X 14.5 203 0.048 1.6 326 0.0 0 0
INFIL. W: 10.1 S: 6.7 46 16. 2 745 2 .4 160 111
DUCTWORK 0.100 283 0.100 0 303
PEOPLE 6 230 300 11380 11800
ROOM TOTALS 3,116 11540 3, 330
RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096
New Residence July 25, 1996 PAGE 14
ZONE # 1 ROOM LOAD SUMMARY *************************
RM ROOM AREA ------ HEATING ------ ------ COOLING ------
NO. DESCRIPTION SF) BTUH % TOT CFM BTUH % TOT CFM
1. MASTER BEDROOM 352 4,804 31.4 62 41732 35.0 215
2. WALK-IN-CLOSET 40 455 3 . 0 6 131 1.0 6
3 . MASTER BATH 174 21688 17.5 35 11955 14.5 89
4. BATH #1 69 725 4.7 9 682 5. 0 31
5. BEDROOM #1 156 31205 20 .9 42 31531 26.1 161
6. BEDROOM #2 165 21175 14.2 28 21053 15. 2 93
7. BATHROOM #2 48 564 3.7 7 220 1.6 10
8. BEDROOM HALL 123 707 4.6 9 208 1.5 9
ZONE SUBTOTAL 1,126 15, 323 100.0 199 13 ,512 100.0 614
VENTILATION 3 ,318 743
LATENT GAIN 4,182
ZONE TOTALS 18,641 18 ,437 1. 536 TONS
RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096
New Residence July 25, 1996 PAGE 15
ZONE # 2 ROOM LOAD SUMMARY *************************
RM ROOM AREA ------ HEATING ------ ------ COOLING ------
NO. DESCRIPTION SF) BTUH % TOT CFM BTUH % TOT CFM
9. LIVING ROOM 253 31559 11. 8 46 31387 14.7 154
10 . FRONT FOYER 124 41465 14.9 58 11467 6.4 67
11. POWDER ROOM-FRONT 28 108 0.4 1 31 0.1 1
12. STUDY 136 11896 6. 3 25 1,687 7. 3 77
13 . FAMILY ROOM 459 11,986 39. 9 156 91659 41. 9 439
14. POWDER ROOM - REAR 33 518 1.7 7 444 1.9 20
15. KITCHEN 340 21373 7. 9 31 21514 10. 9 114
16. MUDROOM 126 21026 6.7 26 528 2. 3 24
19. DINING ROOM 203 31116 10.4 40 31330 14.4 151
ZONE SUBTOTAL 11701 30,047 100. 0 390 23 , 047 100.0 1, 048
VENTILATION 51088 11139
LATENT GAIN 71590
ZONE TOTALS 35,135 31,776 2.648 TONS
RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096
New Residence July 25, 1996 PAGE 16
ZONE # 3 ROOM LOAD SUMMARY *************************
RM ROOM AREA ------ HEATING ------ ------ COOLING ------
NO. DESCRIPTION SF) BTUH % TOT CFM BTUH % TOT CFM
17. LAUNDRY 103 892 12.0 12 259 6 .4 12
18. LOWER REC. ROOM 454 61522 88.0 85 31803 93 .6 173
ZONE SUBTOTAL 557 71414 100. 0 96 41062 100. 0 185
VENTILATION 1,641 367
LATENT GAIN 816
ZONE TOTALS 9,055 5,245 0.437 TONS