Loading...
HomeMy WebLinkAbout2 Karen WaySictric#1464f 5 APPLICATION FOR BUILDING PERMIT Plumbing# qg6 2 KAREN WAY HVAC # U,fA Date: Sprinkler# NO' 2 2 9 7 7 FINAL PPR Estimated Cost $ 6 S DDO Building COMPLETE RED BOXED AREAS Permit Fee 4 G.5'0 Engines in TYPE OR PRINT ONLY Occupancy Fee $ 3 Affidavit SIGN ON REVERSE SIDE Appr.for CO. ff 1 Total Fee 5^ TO BUILDING DEPARTMENT,TOWN OF SOUTH WINDSOR,CT Additional Cost) $361 Th and rsigned hereby applies to do work according to the following specifications: Job Location 44 kAX6,^1 `1/A Lot No. 3 Side of Street Zone fR Applicant Cr/1/V C..Sjj&CX f Tel. # jg!K¢ —.3,'/3 Address o?.S f"ie .OAV. Zip 496!2U Lic.# Owner e aRo5it,Sytll GKt Address ,j 5"-/ W'0Ilt1 GtR ,OAO CSO, I,,//j.0 S c'>R. Archit ct Address Sq. Ft. N w Area: 1st FI. 3 3 S 2nd FI. 3rd Fl. Total New Area Jj S o Rooms Lavatories — Bathrooms 3 Garages Purpose of this permit: 442 AE A-A/"Of L y Q!GLGi/ly City Water d Well D Septic System Sewer V Use Group Construction Type .5Q Area f / Basem t 3f q 3 Garage U Approved by J Date O_A6 Revised 6/95 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked, and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone in which this budding and its use is allowed.r Signed ZAOO I hereby apply for a Certificate of Occupancy for the work described in this application for the permit i Signed DO NOT WRIT BELOW THIS LINE -- INSPECTION COMMENTS Location of Job: AFFIDAVIT Additional Fee S -3 Co. 0,3 State of Connecticut ss.South Windsor County of Hartford caner I ,L/t/Y ,l.Pigsn//';<<of Agent for the building erected Contractor under Permit No. 7 7 issued by the Building Department of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized under said permit did not exceed the most current accepted BOCA value of S Z/!j-j30-2-3 Signed Subcribed and sworn to before me this /1 7k day of SPA 1 5 A.D. 1957 Estimated Cost S J 00 Difference: $ ¢.3, z Notary Public Inspection / Approval Date By Appl Code Description Due Whom Code Comment 96-22977-B 165,000 B01 FOOTING 05/13/96 JFH A BACK HALF B01 FOOTING 05/14/96 JFF A WE EAST HALF OF FOOTING B02 FOUNDATION 06/13/96 JFF A P02 UNDERGROUND 09/13/96 JFF A B05 FIREPLACE/CHIMNEY 09/17/96 JFF A CELLAR THROAT ONLY NEED ADDITIONAL INSPT 1ST FLOOR E01 SERVICE 09/17/96 JFF A NOTIFIED NU B05 FIREPLACE/CHIMNEY 09/19/96 JFF A FIRST FLOOR B03 FRAMING (ROUGH) 03/21/97 JFH A P03 ROUGH 03/21/97 JFH A E03 ROUGH 03/21/97 JFH A B04 INSULATION 04/15/97 JFF A WALLS ONLY EXPOSED VAPOR BARRIER IN CELLAR NOTIFIED CONTRACTOR B10 FINAL 07/30/97 JFF D GARAGE GFI-S/CHIMNEY FLU/GROUNDWIRE WATER METER/HOUSE NUMBERS B10 FINAL 07/31/97 JFF A APPROVED FOR CO BLDG 96-9804-P 9,000 96-9616-H 10,000 96-14098-E 1,000 Total Est Value 185,000 Dwelling 3,443 140,887.56 Basement 3,443 42,693.20 Garage 810 10,044.00 Smoke Det 7 525.00 BOCA Value 219,389.23 Difference 34,389.23 l/ j1eA- . v SITE COMPLIANCE CHECKLIST J TOWN of SOUTH WINDSOR, CONNECTICUT Bf 2 KAREN WAY LOT_# 3 Reviewed B E inee 'n ) KRASNICKI HENRY Date Reviewed 91121,V71 25-1 ARTHUR DRIVE,SOUTH WINDSOR,CT Reviewed By n s BP #_22977_ Ph # (860) 644-3713 Date Review Approve i Date Submitted 08/12/97 FOR C of O *** As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A J 1. Approved building permit plan 2. Finish grading per approved building permit plan 3. Site work; i.e. trees, shrubs, dumpsters, required parking 4. Utility location; a. sanitary sewer/septic system b. foundation drain C. electrical & telephone d. water e. other 5. Sewer connection charge paid 6. Appropriate certification 7. Bonding 8. Planning & Zoning/ Inland Wetlands Considerations Sewer Permit NO. (2LI"T O Pavement Excavation No. COMMENTS: c on iul-M er nil r) t0000, 7. _ SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 2 KAREN WAY LOT-# 3 Reviewed Engineering) KRASNICKI HENRY Date ReviewedVIM25-1 ARTHUR DRIVE,SOUTH WINDSOR,CT Reviewed By Planning) BP # 22977 Ph # (860)644-3713 Date Revi PPDateSubmitted03/14/96 FORIT In accordance with the Zoning and/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted k for approval. The minimum requirements shall include: AppA v Denied 1. Name, addre phone numb of owner/applicant 2. Name, address & phone number of plan preparer 3. Zoning Information - i.e. zone, open space, floodway, etc. 4. Plot Plan at 1" = 40' scale a. Subdivision reference, abutting properties, etc. b. Easements of record c. Lot description, bearings, building lines, distances, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate e. Building location with dimensions. Elevations of proposed finish floor, garage floor & centerline of road at driveway f. Elevations of gravity drainage systems, sanitary foundation drain at the house and the street off' g. Tentative utility location (gas, water, electric, septic system, etc.)r h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements. (P.E. & L.S.) y( 5. Sedimentation and erosion control kAWZ-aM1 6. Special Planning & Zoning, Inland/Wetlands considerations (Plans on file w/Town Clerk) 11 COMMENTS: c,,.SIXQ-' 'r d UA-4J1 ILL_XA—*o V PERMIT DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby : TOWN OF SOUTH WINDSOR BUILDING INSPECTION DEPT. APPROVED DISAPPROVED 1540 SULLIVAN AVENUE 644-2511 Ext. 230 D t it g Inspector Application must be printed or typed 1 . LOCATION OF JOB z KA,16 `y No . Street FEE SCHEDULE Floor Apt . No. 0 - $19000 - 10.00 el r r Ov r $19 000 -10.00 2 . OWNER l/` per $1 ,000 or fraction thereof 3. ADDRESS c 11`rJ D 5c,P t0A11 V 4, APPLICANT Lv5 . ADDRESS fL' L,0Ule l 6. ESTIMATED COST $ I 0,0 Z 7 . IS THIS A CONTRACT COST V Yee No 8 . FEE ENCLOSED $ /0 d c) 9 . TYPE OF BUILDING: VRESIDENTIAL COMMERCIAL 10. TYPE OF JOB: Original Installation Alteration/Addition/Repair RD 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11 . LOCATION OF JOB C// v L/ r NO . STREET APT. NO , 12 . TYPE OF INSTALLATION 13 . SIZE OF MAIN FEEDER 2 D,n A J 1 - 0A2YO V 14 . NO . OF LIGHT LOOPS4-_LQ_ 15 . NO. OF HEAT LOOPS 16 . NO . OF POWER LOOPSj_jD 17 . NO. OF LIGHT OUTLETS _ 18 . NO . OF HEAT CIRCUITS 19 . NO. OF POWER OUTLETS 1 20 . NO. OF CONVENIENCE OUTLETS '2Z C) 21. NO. OF HEAT CIRCUITS Z 22 . NO ,, OF POWER CIRCUITS-CZ / () 23. NO. OF LIGHT CIRCUIT-5 24. SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS 26 . N0 . OF PANELS C/iC 27 . TOTAL WATTAGE 28 . NO . OF POWER FEEDERS 29 . NO. OF SWITCHES f _ 30 . A/C LOAD AV04 7Zc7!/ 31. SIZE OF POWER FEEDERS 20 -1,1'1Q4 32 . NO . OF FIXTURES- Z 33. TOTAL HORSEPOWER 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES P //L 0 G/Ap C 6- A- 0/ 91 7-s- cTrr-- 35 . REMARKS AND FURTHER DETAILS : log q7-- 94 LICENSE NO .SIGNATURE OF APPLICANT DATE PHONE NUMBER: a PERMIT NO. 9- DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT Application is hereby :TOWN OF SOUTH WINDSOR APPROVED DISAPPROVED BUILDING INSPECTION DEPT. 1540 SULLIVAN AVENUE el 644-2511 Ext. 230 a e Inspector Applications must be printed or typed 1. LOCATION OF JOB: Z— KA 9-,g v.,/ LA,)o 1i LOT 5 FEE SCHEDULE 2. OWNER: a!1 1 3. ADDRESS: 4 Q,`'h 0 - $1 ,000 - 10.00 10.o v ba C Over $1 ,000 - 0 per $1 ,000 or 4. APPLICANT: y r fraction thereof 5. ADDRESS: g d V("6 N r` Q.7 6. EST. COST: $ 7. IS THIS A CONTRACT COST? YES _a0O 8. FEE ENCLOSED: $ a 0 29?7 9. TYPE OF BUILDING: N_RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: ORIGINAL ALTERATION INSTALLATION ADDITION REPAIR BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: L4,'A "j GENERAL PLUM NG 12. KIND OF INSTALLATION: 13. SIZE OF MAIN DRAIN 504 qj) 14. NO. OF TOILETS __STYLE .6 15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS 3 16A. NO. OF SHOWERS 17. NO. OF LAVATORIES 18. NO. OF SINKS 19. DISPOSAL_ 19A. DISWASHER ! 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS t-SIZE 3 h 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? L 31. SIZE OF WATER MAIN 1 ^ 31A. SIZES OF WATER PIPING & RISERS ,-) d-- a+ 32. REMARKS AND FURTHER DETAILS WATER HEATER 33. TYPE 34. MANUFACTURER TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE LBS. 40. MANUFACTURER 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE 38. TYPE 42. MANUFACTURER LICENSE NO. ATE IGNATURE OF APPLICANT PHONE NO.a %-- DEPARTMENT DECISION RNUT:9 APPLICATION FOR HVAC PERMIT P 61L A Application is hereby: TOWN of SOUTH WINDSOR Bldg Permit#BUILDING DEPARTMENT 7 APPROVE 1540 SULLIVAN AVENUE 644-2511 ext. 230 2 f IIDate Building Inspector Application must be printed or typed Location ofjob Street No. Street' Lot No. FEE SCHEDULE Floor Apt.No. 0 - $1,000 - $12.00 Over $1,000 Street 12.00 per$1,000 OWNER 54.2L e-- or any fraction thereof ADDRESS---..2.5-- Z?X e 15 014P C r -- A6 014 OWNERS PHONE# 644 -37 /3 APPLICANT 7 c 0* ADDRESS 4( ESTIMATED COST $0 C IS THIS A CONTRACT COST? YES NO FEE ENCLOSED $ )ILO hl TYPE OF JOB:OR-C Ll original Installation Alteration/Addition/Repair Revised 11/95 APPLICATION FOR HVAC PERMIT(Continued from reverse side) TYPE OF SYSTEM TYPE OF BUILDING HEATING RESIDENTIAL ,k A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS.HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR_4 UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE_-5- F INSIDE IZ F DIFFERENCE o 8F TOTAL HEAT LOSS(BTUH) 6 c U HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) Gco TYPE OF FUEL OIL-GPM GAS-INPUT ELECTRIC-KW AIAI Z/o sn' OIL TANK SIZE&LOCATION 341000 INSIDE OUTSIDE CAPACITY LPG TANK CAPACITY S J r AIR CONDITIONING DESIGN TEMP. OUTSIDE 9O F INSIDE7J F DIFFERENCE 1-5- F TOTAL HEAT GAIN(BTUH) 5-3-//6,0 HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH),O D VENTILATION DESCRIBE ALL AIR HANDLING E UIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT), ch e TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) 2,00 PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK .?_O 0 0 L, iO;._ ?Ic/ j -4 1,fres i r.S.C,L•e- d-- .Pig,o= I Oy4 C 1/L lr' .M THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN. BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. S ATE LICENSE-NO. NAME&TYPE IGNAOtRE017 APPLICANT PHONE NO. DATE i/ Apr 70 r s / w RESIDENCE MR. & MRS. HENRY KRASNICKI 21 KAREN WAY SOUTH WINDSOR, CT. 06074 PHONE: 860 644 3713 PREPARED BY NORM TWITCHELL & ASSOCIATES 16 STEVENS STREET WINDSOR LOCKS, CT. 06096 PHONE: 860 623 2318 NORM TWITCHELL & ASSOCIATES PROJECT: New Residence 16 STEVENS STREET CLIENT: Mr. & Mrs. Henry Krasni WINDSOR LOCKS, CT 06096 DATE: July 25, 1996 RESIDENTIAL/LIGHT COMMERCIAL HVAC LOADS DESIGNER:Norman P. Twitchell CLIENT INFORMATION: NAME: Mr. & Mrs. Henry Krasnicki ADDRESS: 25-1 Arthur Drive CITY, STATE: South Windsor TOTAL BUILDING LOADS: BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAL DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN 3-D WINDOW DBL PN LOW EMIT WOOD FR 426 10, 303 0 13,810 13 ,810 9-J FRENCH DOOR DBL LOW E WOOD FR 134 31071 0 51476 5,476 12-K WALL R-19 +111EXTRPOLY BRD(R-5.0) 2,139 6 ,446 0 11789 11789 13-K PART R-19 +111EXTRPOLY BRD(R-5.0) 874 11319 0 394 394 11-A DOOR METAL FIBERGLASS CORE 60 21373 0 657 657 16-H CEILING R-38 INSULATION 21473 4, 307 0 2 ,508 21508 18-F ROOF+CEIL R-30 BATTS(2X10 RAFTR) 459 1,076 0 627 627 19-D FLOOR/ENCL CRAWL HARDWD + R-19 871 1,516 0 0 0 19-I FLOOR/ENCL CRAWL CARPET + R-19 203 326 0 0 0 20-D FLOOR/OPEN CRAWL HARDWD + R-19 1, 858 6,473 0 967 967 21-A BASEMT FLOOR 2'OR> BELOW GRADE 454 730 0 0 0 SUBTOTALS FOR STRUCTURE: 9,951 37,940 0 261F228 26 , 228 PEOPLE 26 0 51980 71800 13 ,780 APPLIANCES 0 0 1,200 11400 2,600 DUCTWORK 0 41798 0 31694 3,694 INFILTRATION W.CFM: 136 .3 S.CFM: 90.9 0 10,048 21163 1,500 3 ,663 VENTILATION W.CFM: 136. 3 S.CFM: 136. 3 0 10,048 3 ,245 2,250 5,495 SENSIBLE GAIN TOTAL 42,872 TEMP. SWING MULTIPLIER X 1.00 BUILDING LOAD TOTALS 62 , 832 12 ,588 42 , 872 55,460 LOAD SUMMARY FOR ZONE #1 SUPPLY CFM AT 20 DEG DT: 614 CFM PER SQUARE FOOT: 0.545 SQUARE FT. OF ROOM AREA: 1 ,127 SQUARE FOOT PER TON: 733. 525 TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 18.641 MBH TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 1.536 TONS RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096 New Residence July 25, 1996 PAGE 2 BUILDING LOADS (CONTINUED) ************************* LOAD SUMMARY FOR ZONE #2 SUPPLY CFM AT 20 DEG DT: 11048 CFM PER SQUARE FOOT: 0.616 SQUARE FT. OF ROOM AREA: 1,702 SQUARE FOOT PER TON: 642.749 TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 35.135 MBH TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 2.648 TONS LOAD SUMMARY FOR ZONE #3 SUPPLY CFM AT 20 DEG DT: 185 CFM PER SQUARE FOOT: 0. 332 SQUARE FT. OF ROOM AREA: 557 SQUARE FOOT PER TON: 1, 274. 357 TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 9.055 MBH TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 0.437 TONS TOTAL BUILDING LOAD SUMMARY SUPPLY CFM AT 20 DEG DT: 11847 CFM PER SQUARE FOOT: 0. 545 SQUARE FT. OF ROOM AREA: 3 ,386 SQUARE FOOT PER TON: 732.636 TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 62 .832 MBH TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 4.622 TONS CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J. ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY. BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS. RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096 New Residence July 25, 1996 PAGE 3 TOTAL ZONE LOADS FOR ZONE # 1 *********************** BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAL DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN 3-D WINDOW DBL PN LOW EMIT WOOD FR 98 21370 0 41928 4 , 928 9-J FRENCH DOOR DBL LOW E WOOD FR 54 1, 237 0 2,916 21916 12-K WALL R-19 +111EXTRPOLY BRD(R-5.0) 722 2,175 0 603 603 16-H CEILING R-38 INSULATION 11127 11963 0 11143 11143 19-D FLOOR/ENCL CRAWL HARDWD + R-19 117 204 0 0 0 20-D FLOOR/OPEN CRAWL HARDWD + R-19 1,010 3 ,519 0 525 525 SUBTOTALS FOR STRUCTURE: 3 ,128 11,468 0 10, 115 10,115 PEOPLE 6 0 11380 11800 31180 APPLIANCES 0 0 11200 0 1,200 DUCTWORK 0 11392 0 1,229 11229 INFILTRATION W.CFM: 33 .4 S.CFM: 22. 3 0 2,463 530 368 898 VENTILATION W.CFM: 45. 0 S.CFM: 45.0 0 31318 11072 743 1 ,815 SENSIBLE GAIN TOTAL 14,255 TEMP. SWING MULTIPLIER X 1.00 BUILDING LOAD TOTALS 18,641 41182 14, 255 18,437 SUPPLY CFM AT 20 DEG DT: 614 CFM PER SQUARE FOOT: 0.545 SQUARE FT. OF ROOM AREA: 1,127 SQUARE FOOT PER TON: 733 .525 TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 18.641 MBH TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 1.536 TONS CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J. ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY. BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS. RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096 New Residence July 25, 1996 PAGE 4 TOTAL ZONE LOADS FOR ZONE # 2 *********************** BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAL DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN 3-D WINDOW DBL PN LOW EMIT WOOD FR 286 6 ,919 0 71496 71496 9-J FRENCH DOOR DBL LOW E WOOD FR 40 917 0 11240 11240 12-K WALL R-19 +111EXTRPOLY BRD(R-5.0) 941 21836 0 788 788 13-K PART R-19 +111EXTRPOLY BRD(R-5.0) 240 362 0 108 108 11-A DOOR METAL FIBERGLASS CORE 60 21373 0 657 657 16-H CEILING R-38 INSULATION 11243 21165 0 11261 1, 261 18-F ROOF+CEIL R-30 BATTS(2X10 RAFTR) 459 11076 0 627 627 19-D FLOOR/ENCL CRAWL HARDWD + R-19 651 1, 133 0 0 0 19-I FLOOR/ENCL CRAWL CARPET + R-19 203 326 0 0 0 20-D FLOOR/OPEN CRAWL HARDWD + R-19 848 2,954 0 442 442 SUBTOTALS FOR STRUCTURE: 41971 21,061 0 12 ,619 12 ,619 PEOPLE 20 0 4 ,600 61000 10,600 APPLIANCES 0 0 0 11400 11400 DUCTWORK 0 2,732 0 2,095 2,095 INFILTRATION W.CFM: 84.9 S.CFM: 56.6 0 61256 11347 934 2, 281 VENTILATION W.CFM: 69.0 S.CFM: 69.0 0 5,088 1,643 11139 21782 SENSIBLE GAIN TOTAL 24,187 TEMP. SWING MULTIPLIER X 1 . 00 BUILDING LOAD TOTALS 35,135 71590 24,187 31,777 SUPPLY CFM AT 20 DEG DT: 11048 CFM PER SQUARE FOOT: 0.616 SQUARE FT. OF ROOM AREA: 1,702 SQUARE FOOT PER TON: 642.749 TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 35.135 MBH TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 2 .648 TONS CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J. ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY. BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS. RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096 New Residence July 25, 1996 PAGE 5 TOTAL ZONE LOADS FOR ZONE # 3 *********************** BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAL DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN 3-D WINDOW DBL PN LOW EMIT WOOD FR 42 11014 0 11386 11386 9-J FRENCH DOOR DBL LOW E WOOD FR 40 917 0 1, 320 11320 12-K WALL R-19 +111EXTRPOLY BRD(R-5.0) 476 11435 0 398 398 13-K PART R-19 +1"EXTRPOLY BRD(R-5.0) 634 957 0 286 286 16-H CEILING R-38 INSULATION 103 179 0 104 104 19-D FLOOR/ENCL CRAWL HARDWD + R-19 103 179 0 0 0 21-A BASEMT FLOOR 2'OR> BELOW GRADE 454 730 0 0 0 SUBTOTALS FOR STRUCTURE: 11852 51411 0 31494 31494 PEOPLE 0 0 0 0 0 APPLIANCES 0 0 0 0 0 DUCTWORK 0 674 0 370 370 INFILTRATION W.CFM: 18. 0 S.CFM: 12.0 0 1 , 329 286 198 484 VENTILATION W.CFM: 22. 3 S.CFM: 22. 3 0 1,641 530 367 897 SENSIBLE GAIN TOTAL 4,429 TEMP. SWING MULTIPLIER X 1. 00 BUILDING LOAD TOTALS 9,055 816 4,429 5,245 SUPPLY CFM AT 20 DEG DT: 185 CFM PER SQUARE FOOT: 0. 332 SQUARE FT. OF ROOM AREA: 557 SQUARE FOOT PER TON: 1, 274. 357 TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 9.055 MBH TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 0.437 TONS CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J. ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY. BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS. RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096 New Residence July 25, 1996 PAGE 6 MISCELLANEOUS PROJECT DATA ************************* DESIGN CONDITIONS: WINTER SUMMER OUTDOOR DRY BULB TEMPERATURE 5 DEG.F 90 DEG.F INDOOR DRY BULB TEMPERATURE - ZONE 1 72 DEG.F 75 DEG.F INDOOR DRY BULB TEMPERATURE - ZONE 2 72 DEG.F 75 DEG.F INDOOR DRY BULB TEMPERATURE - ZONE 3 72 DEG.F 75 DEG.F DESIGN TEMPERATURE DIFFERENCE - ZONE 1 67 DEG.F 15 DEG.F DESIGN TEMPERATURE DIFFERENCE - ZONE 2 67 DEG.F 15 DEG.F DESIGN TEMPERATURE DIFFERENCE - ZONE 3 67 DEG.F 15 DEG.F INDOOR-OUTDOOR GRAINS DIFFERENCE 35 GRAINS OUTDOOR DAILY TEMPERATURE RANGE MED GENERAL PROJECT DATA: PROJECT DATA FILE NAME: C:\RHVAC\KRASNICK TOTAL GROSS WALL AREA (SF) : 3 ,633 . 00 NON-GLASS DOOR AREA (SF) : 60.00 TOTAL NET GLASS AREA (SF) : 560. 00 TOTAL SKYLIGHT AREA (SF) : 0.00 TOTAL NET WALL AREA (SF) : 31013 . 00 TOTAL NET ROOF AREA (SF) : 21932.00 TOTAL EXPOSED AREA (SF) : 6,565.00 PEOPLE LATENT LOAD MULTIPLIER: 230.00 PEOPLE SENSIBLE LOAD MULTIPLIER: 300. 00 LATITUDE DEGREES: 41.00 TEMPERATURE SWING MULTIPLIER: 1. 00 EXTERNAL SHADING TYPES: NO. OVERHANG OFFSET 1. 0.0 0.0 2 . 0.0 0.0 3 . 0. 0 0.0 4. 0.0 0.0 5. 0.0 0. 0 6. 0 .0 0.0 7. 0.0 0.0 OUTSIDE AIR DATA: WINTER SUMMER INFILTRATION AIR CHANGES PER HOUR: 0. 300 0. 200 CUBIC FEET OF CONDITIONED SPACE: X 27, 267 X 27, 267 81180 5,453 X 0.0167 X 0.0167 TOTAL BUILDING INFILTRATION CFM: 136. 3 90. 9 TOTAL BUILDING VENTILATION CFM: 136.0 136 .0 INFIL. & VENT. SEN. GAIN MULTIPLIER: 16.50 = (1.10 X 15 SUMMER TEMP. DIFF. ) INFIL. & VENT. LAT. GAIN MULTIPLIER: 23 .80 = (0.68 X 35 GRAINS DIFFERENCE) INFIL. & VENT. SEN. LOSS MULTIPLIER: 73.70 = (1.10 X 67 WINTER TEMP. DIFF. ) RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096 New Residence July 25, 1996 PAGE 7 DETAILED ROOM LOADS * *************************** ITEM AREA -U-HTG SEN. CLG LAT. SEN. DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN 1. MASTER BEDROOM 16.0 WID X 22.0 LEN = 352 SF CEIL.HT = 8.0 SE-WALL-12K 8 X 16 74 0. 045 3. 0 223 0. 8 0 62 S -WALL-12K 8 X 6 48 0.045 3 .0 145 0.8 0 40 SW-WALL-12K 8 X 2 16 0.045 3 .0 48 0. 8 0 13 SE-G.DR-9J 2-P 0-0 S-1 0%S 54 0. 342 22.9 11237 54.0 0 2,916 CEIL-16H DARK 22 X 16 352 0.026 1.7 613 1. 0 0 357 FLOOR-20D 22 X 16 352 0.052 3 .5 11226 0.5 0 183 INFIL. W: 11. 9 S: 7. 9 54 16. 2 875 2 .4 188 131 DUCTWORK 0.100 437 0.100 0 430 PEOPLE 2 230 300 460 600 ROOM TOTALS 4,804 648 41732 2. WALK-IN-CLOSET 5.5 WID X 7. 2 LEN =40 SF CEIL.HT = 8.0 S -WALL-12K 8 X 7.2 58 0 .045 3 .0 175 0.8 0 49 SE-WALL-12K 8 X 1. 3 10 0.045 3.0 30 0. 8 0 8 CEIL-16H DARK 7. 2 X 5.5 40 0.026 1 .7 70 1.0 0 41 FLOOR-20D 7. 2 X 5.5 40 0. 052 3.5 139 0.5 0 21 INFIL. W: 0.0 S: 0.0 0 16. 2 0 2.4 0 0 DUCTWORK 0.100 41 0. 100 0 12 ROOM TOTALS 455 0 131 3. MASTER BATH 12 .7 WID X 13 .7 LEN = 174 SF CEIL.HT = 8. 0 SE-WALL-12K 8 X 13 .7 98 0 .045 3 .0 295 0 .8 0 82 SE-WALL-12K 8 X 12.7 90 0. 045 3.0 271 0. 8 0 75 SE-GLAS-3D 2-P 0-0 S-1 0%S 12 0.361 24.2 290 54.0 0 648 SE-GLAS-3D 2-P 0-0 S-1 0%S 12 0. 361 24.2 290 54. 0 0 648 CEIL-16H DARK 13 .7 X 12.7 174 0.026 1.7 303 1.0 0 176 FLOOR-20D 13 .7 X 12.7 174 0. 052 3.5 606 0.5 0 90 INFIL. W: 5. 3 S: 3 .5 24 16 . 2 389 2.4 84 58 DUCTWORK 0.100 244 0.100 0 178 APPLIANCES 11200 0 ROOM TOTALS 2,688 1,284 1,955 RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096 New Residence July 25, 1996 PAGE 8 DETAILED ROOM LOADS ***************************** ITEM AREA -U-HTG SEN. CLG LAT. SEN. DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN 4. BATH #1 5.0 WID X 13 .7 LEN =69 SF CEIL.HT = 8 .0 E -WALL-12K 8 X 5 32 0. 045 3. 0 96 0. 8 0 27 E -GLAS-3D 2-P 0-0 S-1 0%S 8 0. 361 24.2 193 63 .0 0 504 CEIL-16H DARK 13 .7 X 5 69 0. 026 1.7 120 1.0 0 70 FLOOR-19D 13 .7 X 5 69 0.052 1 .7 120 0.0 0 0 INFIL. W: 1. 8 S: 1. 2 8 16. 2 130 2.4 28 19 DUCTWORK 0 .100 66 0.100 0 62 ROOM TOTALS 725 28 682 5. BEDROOM #1 12 .0 WID X 13 .0 LEN = 156 SF CEIL.HT = 8.0 E -WALL-12K 8 X 12 76 0. 045 3 . 0 229 0.8 0 64 NW-WALL-12K 8 X 13 84 0.045 3 .0 253 0.8 0 70 E -GLAS-3D 2-P 0-0 S-1 0%S 20 0.361 24.2 484 63. 0 0 11260 NW-GLAS-3D 2-P 0-0 S-1 100%S 20 0. 361 24. 2 484 44.0 0 880 CEIL-16H DARK 13 X 12 156 0. 026 1.7 272 1. 0 0 158 FLOOR-20D 13 X 12 156 0.052 3 .5 544 0.5 0 81 INFIL. W: 8.8 S: 5. 9 40 16.2 648 2.4 140 97 DUCTWORK 0 .100 291 0 .100 0 321 PEOPLE 2 230 300 460 600 ROOM TOTALS 31205 600 3,531 6. BEDROOM #2 12.5 WID X 13 .2 LEN = 165 SF CEIL.HT = 8. 0 NW-WALL-12K 8 X 13 . 2 86 0.045 3 .0 259 0.8 0 72 W -WALL-12K 8 X 2 16 0. 045 3.0 48 0. 8 0 13 NW-GLAS-3D 2-P 0-0 S-1 100%S 20 0. 361 24. 2 484 44.0 0 880 CEIL-16H DARK 13.2 X 12 .5 165 0.026 1.7 287 1.0 0 167 FLOOR-20D 13 .2 X 12 .5 165 0.052 3 .5 575 0.5 0 86 INFIL. W: 4.4 S: 2 .9 20 16. 2 324 2 .4 70 48 DUCTWORK 0.100 198 0.100 0 187 PEOPLE 2 230 300 460 600 ROOM TOTALS 2,175 530 2,053 RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096 New Residence July 25, 1996 PAGE 9 DETAILED ROOM LOADS ***************************** ITEM AREA -U-HTG SEN. CLG LAT. SEN. DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN 7. BATHROOM #2 5.0 WID X 9.6 LEN =48 SF CEIL.HT = 8 .0 N -WALL-12K 8 X 5 34 0. 045 3 . 0 103 0. 8 0 28 N -GLAS-3D 2-P 0-0 S-1 0%S 6 0. 361 24.2 145 18.0 0 108 CEIL-16H DARK 9.6 X 5 48 0. 026 1.7 84 1.0 0 49 FLOOR-19D 9.6 X 5 48 0.052 1.7 84 0.0 0 0 INFIL. W: 1. 3 S: 0. 9 6 16. 2 97 2. 4 21 15 DUCTWORK 0 .100 51 0.100 0 20 ROOM TOTALS 564 21 220 8. BEDROOM HALL 4.9 WID X 25.0 LEN = 123 SF CEIL.HT = 8.0 CEIL-16H DARK 25 X 4. 9 123 0. 026 1.7 214 1. 0 0 125 FLOOR-20D 25 X 4.9 123 0.052 3 .5 429 0.5 0 64 INFIL. W: 0. 0 S: 0.0 0 16. 2 0 2 .4 0 0 DUCTWORK 0.100 64 0 .100 0 19 ROOM TOTALS 707 0 208 9. LIVING ROOM 14.9 WID X 17.0 LEN = 253 SF CEIL.HT = 8.0 E -WALL-12K 8 X 3 . 9 31 0.045 3 . 0 93 0. 8 0 26 N -WALL-12K 8 X 15 81 0 .045 3 .0 244 0.8 0 68 N -GLAS-3D 2-P 0-0 S-1 0%S 30 0. 361 24. 2 726 18. 0 0 540 N -GLAS-3D 2-P 0-0 S-1 0%S 9 0.361 24.2 218 18.0 0 162 CEIL-16H DARK 17 X 14. 9 253 0.026 1.7 441 1.0 110 257 FLOOR-20D 17 X 14.9 253 0.052 3 .5 881 0.5 0 132 INFIL. W: 8.6 S: 5.7 39 16.2 632 2.4 136 94 DUCTWORK 0.100 324 0.100 0 308 PEOPLE 6 230 300 11380 11800 ROOM TOTALS 3 ,559 1,516 3, 387 RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096 New Residence July 25, 1996 PAGE 10 DETAILED ROOM LOADS ********** ****************** ITEM AREA -U-HTG SEN. CLG LAT. SEN. DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN 10. FRONT FOYER 10. 3 WID X 12.0 LEN = 124 SF CEIL.HT = 11.4 N -WALL-12K 11.4 X 10.4 48 0.045 3 .0 145 0.8 0 40 N -DOOR-11A 6.8 X 3 20 0.590 39.5 791 11. 0 0 219 N -DOOR-11A 6.8 X 3 20 0.590 39.5 791 11.0 0 219 N -GLAS-3D 2-P 0-0 S-1 0%S 8 0. 361 24.2 193 18. 0 0 144 N -GLAS-3D 2-P 0-0 S-1 0%S 8 0 . 361 24. 2 193 18.0 0 144 N -GLAS-3D 2-P 0-0 S-1 0%S 15 0. 361 24. 2 363 18.0 0 270 CEIL-16H DARK 12 X 10.3 124 0.026 1.7 216 1.0 0 126 FLOOR-19D 12 X 10. 3 124 0.052 1.7 216 0. 0 0 0 INFIL. W: 15.6 S: 10.4 71 16 .2 11151 2.4 248 172 DUCTWORK 0.100 406 0.100 0 133 ROOM TOTALS 4,465 248 1,467 11. POWDER ROOM-FRONT 4. 0 WID X 6.9 LEN =28 SF CEIL.HT = 0. 0 CEIL-16H DARK 6.9 X 4 28 0 .026 1.7 49 1.0 0 28 FLOOR-19D 6.9 X 4 28 0. 052 1.7 49 0. 0 0 0 INFIL. W: 0.0 S: 0.0 0 16.2 0 2.4 0 0 DUCTWORK 0. 100 10 0.100 0 3 ROOM TOTALS 108 0 31 12. STUDY 11.9 WID X 11.4 LEN = 136 SF CEIL.HT = 8.0 S -WALL-12K 8 X 9 52 0 .045 3 .0 157 0 .8 0 44 E -WALL-12K 8 X 2 16 0. 045 3 .0 48 0. 8 0 13 S -GLAS-3D 2-P 0-0 S-1 0%S 20 0 . 361 24.2 484 31.0 0 620 CEIL-16H DARK 11.4 X 11.9 136 0. 026 1.7 237 1. 0 0 138 FLOOR-20D 11.4 X 11.9 136 0.052 3 .5 474 0.5 0 71 INFIL. W: 4.4 S: 2. 9 20 16. 2 324 2 .4 70 48 DUCTWORK 0.100 172 0.100 0 153 PEOPLE 2 230 300 460 600 ROOM TOTALS 11896 530 1,687 RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096 New Residence July 25, 1996 PAGE 11 DETAILED ROOM LOADS ***************************** ITEM AREA -U-HTG SEN. CLG LAT. SEN. DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN 13 . FAMILY ROOM 11.0 WID X 41.7 LEN = 459 SF CEIL.HT = 8.0 S -WALL-12K 11. 3 X 50 393 0. 045 3 . 0 11185 0. 8 0 329 E -WALL-12K 11.3 X 2 23 0 .045 3.0 69 0.8 0 19 W -WALL-12K 11. 3 X 2 23 0. 045 3 . 0 69 0. 8 0 19 S -GLAS-3D 2-P 0-0 S-1 0%S 20 0.361 24.2 484 31.0 0 620 S -GLAS-3D 2-P 0-0 S-1 O%S 20 0. 361 24.2 484 31. 0 0 620 S -GLAS-3D 2-P 0-0 S-1 0%S 20 0. 361 24. 2 484 31.0 0 620 S -GLAS-3D 2-P 0-0 S-1 0%S 20 0. 361 24. 2 484 31. 0 0 620 S -GLAS-3D 2-P 0-0 S-1 0%S 20 0.361 24.2 484 31.0 0 620 S -GLAS-3D 2-P 0-0 S-1 0%S 20 0. 361 24. 2 484 31.0 0 620 S -G.DR-9J 2-P 0-0 S-1 O%S 40 0.342 22.9 917 31.0 0 1, 240 S -GLAS-3D 2-P 0-0 S-1 0%S 12 0. 361 24. 2 290 31. 0 0 372 ROOF-18F DARK 41.7 X 11 459 0.035 2 .3 11076 1.4 0 627 FLOOR-20D 41.7 X 11 459 0. 052 3 .5 11599 0.5 0 239 INFIL. W: 37.8 S: 25.2 172 16 . 2 21787 2.4 600 416 DUCTWORK 0.100 11090 0.100 0 878 PEOPLE 6 230 300 11380 11800 ROOM TOTALS 11,986 11980 91659 14. POWDER ROOM - REAR 6.0 WID X 5.5 LEN =33 SF CEIL.HT = 8.0 SW-WALL-12K 8 X 5. 5 38 0. 045 3. 0 115 0.8 0 32 SW-GLAS-3D 2-P 0-0 S-1 O%S 6 0. 361 24.2 145 54.0 0 324 CEIL-16H DARK 5.5 X 6 33 0.026 1.7 57 1.0 0 33 FLOOR-19D 5.5 X 6 33 0.052 1.7 57 0.0 0 0 INFIL. W: 1. 3 S: 0. 9 6 16. 2 97 2.4 21 15 DUCTWORK 0.100 47 0 .100 0 40 ROOM TOTALS 518 21 444 RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096 New Residence July 25, 1996 PAGE 12 DETAILED ROOM LOADS ***************************** ITEM AREA -U-HTG SEN. CLG LAT. SEN. DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN 15. KITCHEN 16. 2 WID X 21.0 LEN = 340 SF CEIL.HT = 8.0 S -WALL-12K 8 X 6.2 38 0.045 3 .0 115 0.8 0 32 SW-WALL-12K 8 X 10 80 0. 045 3. 0 241 0. 8 0 67 NW-PART-13K 8 X 11 88 0.045 1.5 133 0.5 0 40 S -GLAS-3D 2-P 0-0 S-1 0%S 12 0. 361 24. 2 290 31. 0 0 372 CEIL-16H DARK 21 X 16. 2 340 0.026 1.7 592 1.0 0 345 FLOOR-19D 21 X 16.2 340 0. 052 1.7 592 0.0 0 0 INFIL. W: 2.6 S: 1.8 12 16 .2 194 2.4 42 29 DUCTWORK 0.100 216 0.100 0 229 APPLIANCES 0 11400 ROOM TOTALS 21373 42 21514 16 . MUDROOM 7.0 WID X 18.0 LEN = 126 SF CEIL.HT = 8.0 NW-PART-13K 8 X 7 56 0.045 1. 5 84 0. 5 0 25 W -PART-13K 8 X 12 96 0.045 1.5 145 0.5 0 43 W -WALL-12K 8 X 5 20 0. 045 3 . 0 60 0. 8 0 17 W -DOOR-11A 6.7 X 3 20 0.590 39.5 791 11.0 0 219 CEIL-16H DARK 18 X 7 126 0.026 1.7 219 1.0 0 128 FLOOR-19D 18 X 7 126 0.052 1.7 219 0.0 0 0 INFIL. W: 4.4 S: 2 . 9 20 16.2 324 2.4 70 48 DUCTWORK 0.100 184 0.100 0 48 ROOM TOTALS 21026 70 528 17. LAUNDRY 8.6 WID X 12.0 LEN = 103 SF CEIL.HT = 8.0 S -WALL-12K 8 X 8.5 68 0. 045 3.0 205 0. 8 0 57 N -PART-13K 8 X 8.5 68 0.045 1.5 103 0.5 0 31 W -PART-13K 8 X 12 96 0. 045 1.5 145 0.5 0 43 CEIL-16H DARK 12 X 8.6 103 0.026 1.7 179 1.0 0 104 FLOOR-19D 12 X 8.6 103 0.052 1 .7 179 0.0 0 0 INFIL. W: 0.0 S: 0.0 0 16.2 0 2.4 0 0 DUCTWORK 0.100 81 0.100 0 24 ROOM TOTALS 892 0 259 RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096 New Residence July 25, 1996 PAGE 13 DETAILED ROOM LOADS ***************************** ITEM AREA -U-HTG SEN. CLG LAT. SEN. DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN 18 . LOWER REC. ROOM 18.9 WID X 24.0 LEN = 454 SF CEIL.HT = 8 .0 E -PART-13K 12 X 14 86 0.045 1.5 130 0.5 0 39 W -PART-13K 12 X 14 168 0.045 1.5 253 0 .5 0 76 N -PART-13K 12 X 18 216 0.045 1.5 326 0.5 0 97 S -WALL-12K 12 X 34 408 0 .045 3 .0 11230 0.8 0 341 E -GLAS-3D 2-P 0-0 S-4 0%S 7 0. 361 24.2 169 33. 0 0 231 E -GLAS-3D 2-P 0-0 S-4 0%S 7 0. 361 24.2 169 33 .0 0 231 E -GLAS-3D 2-P 0-0 S-4 0%S 7 0. 361 24. 2 169 33 . 0 0 231 E -GLAS-3D 2-P 0-0 S-4 0%S 7 0.361 24.2 169 33 .0 0 231 E -GLAS-3D 2-P 0-0 S-4 0%S 7 0. 361 24. 2 169 33 . 0 0 231 E -GLAS-3D 2-P 0-0 S-4 0%S 7 0.361 24.2 169 33 .0 0 231 E -G.DR-9J 2-P 0-0 S-4 0%S 40 0. 342 22. 9 917 33 . 0 0 11320 FLOOR-21A 24 X 18 .9 454 0.024 1.6 730 0.0 0 0 INFIL. W: 18.0 S: 12. 0 82 16. 2 11329 2 .4 286 198 DUCTWORK 0 .100 593 0.100 0 346 ROOM TOTALS 61522 286 31803 19. DINING ROOM 14.5 WID X 14.0 LEN = 203 SF CEIL.HT = 8 .0 N -WALL-12K 8 X 14.5 70 0.045 3.0 211 0.8 0 59 E -WALL-12K 8 X 3 .5 28 0.045 3 .0 84 0.8 0 23 N -GLAS-3D 2-P 0-0 S-1 0%S 35 0. 361 24.2 847 18. 0 0 630 N -GLAS-3D 2-P 0-0 S-1 0%S 11 0.361 24. 2 266 18.0 0 198 CEIL-16H DARK 14 X 14.5 203 0. 026 1.7 354 1.0 0 206 FLOOR-19I 14 X 14.5 203 0.048 1.6 326 0.0 0 0 INFIL. W: 10.1 S: 6.7 46 16. 2 745 2 .4 160 111 DUCTWORK 0.100 283 0.100 0 303 PEOPLE 6 230 300 11380 11800 ROOM TOTALS 3,116 11540 3, 330 RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096 New Residence July 25, 1996 PAGE 14 ZONE # 1 ROOM LOAD SUMMARY ************************* RM ROOM AREA ------ HEATING ------ ------ COOLING ------ NO. DESCRIPTION SF) BTUH % TOT CFM BTUH % TOT CFM 1. MASTER BEDROOM 352 4,804 31.4 62 41732 35.0 215 2. WALK-IN-CLOSET 40 455 3 . 0 6 131 1.0 6 3 . MASTER BATH 174 21688 17.5 35 11955 14.5 89 4. BATH #1 69 725 4.7 9 682 5. 0 31 5. BEDROOM #1 156 31205 20 .9 42 31531 26.1 161 6. BEDROOM #2 165 21175 14.2 28 21053 15. 2 93 7. BATHROOM #2 48 564 3.7 7 220 1.6 10 8. BEDROOM HALL 123 707 4.6 9 208 1.5 9 ZONE SUBTOTAL 1,126 15, 323 100.0 199 13 ,512 100.0 614 VENTILATION 3 ,318 743 LATENT GAIN 4,182 ZONE TOTALS 18,641 18 ,437 1. 536 TONS RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096 New Residence July 25, 1996 PAGE 15 ZONE # 2 ROOM LOAD SUMMARY ************************* RM ROOM AREA ------ HEATING ------ ------ COOLING ------ NO. DESCRIPTION SF) BTUH % TOT CFM BTUH % TOT CFM 9. LIVING ROOM 253 31559 11. 8 46 31387 14.7 154 10 . FRONT FOYER 124 41465 14.9 58 11467 6.4 67 11. POWDER ROOM-FRONT 28 108 0.4 1 31 0.1 1 12. STUDY 136 11896 6. 3 25 1,687 7. 3 77 13 . FAMILY ROOM 459 11,986 39. 9 156 91659 41. 9 439 14. POWDER ROOM - REAR 33 518 1.7 7 444 1.9 20 15. KITCHEN 340 21373 7. 9 31 21514 10. 9 114 16. MUDROOM 126 21026 6.7 26 528 2. 3 24 19. DINING ROOM 203 31116 10.4 40 31330 14.4 151 ZONE SUBTOTAL 11701 30,047 100. 0 390 23 , 047 100.0 1, 048 VENTILATION 51088 11139 LATENT GAIN 71590 ZONE TOTALS 35,135 31,776 2.648 TONS RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* NORM TWITCHELL & ASSOCIATES WINDSOR LOCKS, CT 06096 New Residence July 25, 1996 PAGE 16 ZONE # 3 ROOM LOAD SUMMARY ************************* RM ROOM AREA ------ HEATING ------ ------ COOLING ------ NO. DESCRIPTION SF) BTUH % TOT CFM BTUH % TOT CFM 17. LAUNDRY 103 892 12.0 12 259 6 .4 12 18. LOWER REC. ROOM 454 61522 88.0 85 31803 93 .6 173 ZONE SUBTOTAL 557 71414 100. 0 96 41062 100. 0 185 VENTILATION 1,641 367 LATENT GAIN 816 ZONE TOTALS 9,055 5,245 0.437 TONS