HomeMy WebLinkAbout2 Castlewood Drive (6)DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT
TOWN OF SOUTH WINDSOR
PERMIT#
Application is hereby:
BUILDING DEPARTMENT It S D
APPROVED 1540 SULLIVAN AVENUE
644-2511 ext. 230
Bldg.Permit#
ate Building Inspector
Application must be printed or typed
FEE SCHEDULE Location of Job:
0-$1,000=$15.00 Street No. Street Lot No.
Over$1,000=
15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
APPLICANT IICV
APPLICANT ADDRESS /0 V&Y-ofe-
APPLICANT PHONE# 7,7P,9—
N S F
OWNER
q OWNER ADDRESS
OWNER PHONE0
C ESTIMATED COST$ 2
IS THIS A CONTRACT COST? `Yes No
f FEE ENCLOSED$ D
f
TYPE OF JOB:
OR-CD V New Installation
Alteration/Addition/Repair
Revised 4/01//2002
APPLICATION FOR HVAC PERMIT (Continued from reverse side)
TYPE OFF STEM: TYPE OF B LDING:
O'HEATING 30kESIDENTIAL
A/C COMMERCIAL
VENTILATION INDUSTRIAL
HEATING
STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.
HYDRONIC ZWARM AIR UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE_L°F INSIDE _°F DIFFERENCE_°F
TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION)
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
Ile"z z//, /"
GROSS HEATING CAPACITY(INPUT—BTUH),p NET RATING(OUTPUT—BTUH)
TYPE OF FUEL
OIL--GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY
GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE F OF INSIDE ;>Q—OF DIFFERENCE /.P OF
TOTAL HEAT GAIN(BTUH)(HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
Oc
TONNAGE_ COOLING CAPACITY(BTUH).:52
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF WORK
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
J-
CONTRACTORS LICENSE NO. E STATE
SIGNATURE OF APPPP.ICAN`T DATE Z
RIGHT-J LOAD AND EQUIPMENT SUMMARY
ik . Entire House
R $ E Heating & Cooling Inc. Job:243-046 2 Castl w d Dr
9-26-02
310 Nutmeg Rd.South,South Windsor,Ct 06074 Phone:860-282-7782 Fax:860-282-7701
Proiect Information
For: Clark Realty
658 Ellington RD, South Windsor, Ct 06074
Phone:282-0628
Notes: 243-046 2 Castlewood Dr
D- • n Information
Weather: Hartford, Brainard Field, CT, US
Winter Design Conditions Summer Design Conditions
Outside db 6 OF Outside db 88 OFInsidedb70OFInsidedb70OFDesignTD64OFDesignTD18OF
Daily range M
Relative Humidity 50 %
Moisture difference 38 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Building heat loss 121571 Btuh Structure 45925 BtuhVentilationair0cfmVentilation0BtuhVentilationairloss0BtuhDesigntemperatureswing3.0 OFDesignheatload121571BtuhUsemfa. data n
Rate/swing multiplier 0.93
Infiltration Total sens. equip. load 42710 Btuh
Method Simplified Latent Cooling Equipment Load SizingConstructionqualityAverage
Fireplaces 1 Internal gains 920 Btuh
Ventilation 0 BtuhHeatingCoolingInfiltration3819BtuhArea(ft2)2782 2782 Total latent equip. load 4739 BtuhVolume(ft$) 22256 22256
Air change s/hour 0.9 0.4 Total equipment load 47449 BtuhEquiv,AVF Wrn)335 149
Heating Equipment Summary Cooling Equipment Summary
Make Heil Make HeilTradeHeilTradeHeil
H9MPD100 Haco48
FW48Efficiency92.0 AFUE Efficiency 10.0 EERHatinginput100000BtuhSensiblecooling336000 BtuhHeatingoutput92000BtuhLatentcooling144000BtuhHeatingtemprise52OFTotalcooling480000BtuhActualheatingfan1600cfmActualcoolingfan1600cfmHeatingairflowfactor0.013 cfm/Btuh Cooling air flow factor 0.035 cfm/Btuh
Space thermostat Load sensible heat ratio 91 %
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
Wi1'f Uht50ft Right-Sulte ResidentialTM 5.0.28 RSR27412 2002-S p-26 09:06:52AMCAMyDocuments\Wrightsott HVAC1243-046 2 Castlewood Dr.rlr Page 1
RIGHT-.J SHORT FORM
Entire Hous
R & E Heating & Cooling Inc. Job:243-046 2 Castlewood Dr
9-26-02
310 Nutmeg Rd.South,South Windsor,Ct 06074 Phone:880-282-7782 Fax:860-282-7701
For: Clark Realty
658 Ellington RD, South Windsor, Ct 06074
Phone: 282-0628
Design Information
Htg Clg Infiltration
Outside db(OF) 6 88 Method SimplifiedInsidedb(OF) 70 70 Construction quality AverageDesignTD(OF)64 18 Fireplaces 1DailyrangeM
Inside humidity(%) 50
Moisture difference(gr/lb) - 38
HEATING EQUIPMENT COOLING EQUIPMENT
Make Heil Make Heil
Trade Heil Trade Heil
H9MPD100 Haco48
Fcp48
Effici ncy 92.0 AFUE Efficiency 10.0 EER
Heating input 100000 Btuh Sensible cooling 336000 BtuhHatingoutput92000BtuhLatentcooling144000BtuhHeatingtemperaturerise52OFTotalcooling480000BtuhActualheatingfan1600cfmActualcoolingfan1600cfmHeatingairflowfactor0.013 cfm/Btuh Cooling air flow factor 0.035 cfm/Btuh
Space thermostat Load sensible heat ratio 91 %
ROOM NAME Area Htg load Clg load Htg AVF Clg AVFft2) Btuh) Btuh) cfm) cfm)
First Floor 1482 67558 27084 889 944SecondFloor13005401318841711656
Entire House d 2782 121571 45925 1600 1600Vntilationair00
Equip. @ 0.93 RSM 42710
Latent cooling 4739
TOTALS 1 2782 121571 47449 1600 1600
Printout certified by ACCA to meet all requirements of Manual J 7th Ed.
wnghtsoft Right-Suite Residential"'5.0.28 RSR27412 2002-Sep-26 09:06:52