HomeMy WebLinkAbout1970 John Fitch Boulevard (5)l
r i
LDEPARTMENT
DECISION APPLICATION FOR HVAC PERMIT
TOWN OF SOUTH WINDSOR
PERMIT#
plication is hereby: I 3BUILDINGDEPARTMENT
APPROVE 1540 SULLIVAN AVENUE Bldg.Permit#
Jam.
644-2511 ext. 230
Building Inspector
Application must be printed or typed
FEE SCHEDULE Loc ' of ob:
0-$1,000=$15.00 Street No. Street Lot No.
Over$1,000=
15.00 per$1,000
or any fraction thereof Tenant Designation Apt.No.
i
i
APPLICANT
3
APPLICANT ADDRESS I
Arm aGt
APPLICANT PHONE#
OW N 3 Z4
OWNER ll fJ t
OWNER ADDRESS
e s
J OWNER PHONE I
C ESTIMATED COST$ V
IS THIS A CONTRACT COST? 1'es No
f FEE ENCLOSED$
1 r TYPE OF JOB:
SOR 0
New Installation
eration/Addition/Repair fi
Revised 4/01//2002
APPLICATION FOR HVAC PERMIT (Continued from reverse side)
TYPE OF SygZW. TYPE OF BUILDING:
UITEATING RESIDENTIAL
A/C COMMERCIAL
VENTILATION INDUSTRIAL
HEATING
STEAM LOW PRE,SS1 _ _LIMIT LBS. HIGH PRESSURE LIMIT LBS.
HYDRONIC a<A-RM AIR UNIT RADIANT HEATER
EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION
DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY
APPLICATION) r '3
DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH)
TYPE OF FUEL
OIL—GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY
GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW
AIR CONDITIONING
DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF
TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION)
DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.)
TONNAGE COOLING CAPACITY(BTUH)
VENTILATION
DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT)
TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM)
PLANS MUST ACCOMPANY APPLICATION)
FURTHER DESCRIPTION OF W09 Ioo*& /YA
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO
COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE
PERFORMANCE OF SUCH WORK.
5;0%KM S tl 74-
CONTRACTORS LICENSE NO. TYPE STATE
SIGNATURE OF APPLICAN tl DATE
Short Form Job:
Date:k Entire House By:
AUTOMATIC TLC
64 OAKLAND AVE,E.HARTFORD,CT 06108 Phone:568-1200
Project •
For: CROMBE
RT#5, S Windsor, CT
Design Information
Htg Clg Infiltration
Outside db(OF) 0 95 Method Simplified
Inside db(OF) 70 70 Construction quality Average
Design TD (OF) 70 25 Fireplaces 0
Daily range M
Inside humidity(%) 50
Moisture difference(gr/lb) - 21
HEATING EQUIPMENT COOLING EQUIPMENT
Make Make
Trade Trade
Efficiency 80 AFUE Efficiency 0 EER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Heating temperature rise 0 OF Total cooling 0 Btuh
Actual heating fan 1600 cfm Actual cooling fan 1600 cfm
Heating air flow factor 0.024 cfm/Btuh Cooling air flow factor 0.040 cfm/Btuh
Space thermostat Load sensible heat ratio 94 %
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
ft2) Btuh) Btuh) cfm) cfm)
NEW KITCHEN 528 21136 11645 507 466
EAI LY ROOM 450 16515 10499 396 420
FIRST FLOOR 1050 29062 17834 697 714
Entire House d 2028 66713 39978 1600 1600
Ventilation air 3066 1095
Equip. @ 1.00 RSM 41073
Latent cooling 2733
TOTALS 2028 69779 43807 1600 1600
Bold/Rallc values have been manually overridden
Printout certified by ACCA-rtr0et all requirements of Manual J 8th Ed.
wrigljtSoft Right-Suite Residential 7=16M`j8
20 RSR31194 2003-Mar-17 10:02:21