HomeMy WebLinkAbout1970 John Fitch Boulevard (5)l r i LDEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# plication is hereby: I 3BUILDINGDEPARTMENT APPROVE 1540 SULLIVAN AVENUE Bldg.Permit# Jam. 644-2511 ext. 230 Building Inspector Application must be printed or typed FEE SCHEDULE Loc ' of ob: 0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= 15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. i i APPLICANT 3 APPLICANT ADDRESS I Arm aGt APPLICANT PHONE# OW N 3 Z4 OWNER ll fJ t OWNER ADDRESS e s J OWNER PHONE I C ESTIMATED COST$ V IS THIS A CONTRACT COST? 1'es No f FEE ENCLOSED$ 1 r TYPE OF JOB: SOR 0 New Installation eration/Addition/Repair fi Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SygZW. TYPE OF BUILDING: UITEATING RESIDENTIAL A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRE,SS1 _ _LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC a<A-RM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) r '3 DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL OIL—GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF W09 Ioo*& /YA THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 5;0%KM S tl 74- CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICAN tl DATE Short Form Job: Date:k Entire House By: AUTOMATIC TLC 64 OAKLAND AVE,E.HARTFORD,CT 06108 Phone:568-1200 Project • For: CROMBE RT#5, S Windsor, CT Design Information Htg Clg Infiltration Outside db(OF) 0 95 Method Simplified Inside db(OF) 70 70 Construction quality Average Design TD (OF) 70 25 Fireplaces 0 Daily range M Inside humidity(%) 50 Moisture difference(gr/lb) - 21 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Efficiency 80 AFUE Efficiency 0 EER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Heating temperature rise 0 OF Total cooling 0 Btuh Actual heating fan 1600 cfm Actual cooling fan 1600 cfm Heating air flow factor 0.024 cfm/Btuh Cooling air flow factor 0.040 cfm/Btuh Space thermostat Load sensible heat ratio 94 % ROOM NAME Area Htg load Clg load Htg AVF Clg AVF ft2) Btuh) Btuh) cfm) cfm) NEW KITCHEN 528 21136 11645 507 466 EAI LY ROOM 450 16515 10499 396 420 FIRST FLOOR 1050 29062 17834 697 714 Entire House d 2028 66713 39978 1600 1600 Ventilation air 3066 1095 Equip. @ 1.00 RSM 41073 Latent cooling 2733 TOTALS 2028 69779 43807 1600 1600 Bold/Rallc values have been manually overridden Printout certified by ACCA-rtr0et all requirements of Manual J 8th Ed. wrigljtSoft Right-Suite Residential 7=16M`j8 20 RSR31194 2003-Mar-17 10:02:21 C:\My Documents\Wrightsoft HVAC\CROMBE.rrp Cal Orientation=N Page 1