Loading...
HomeMy WebLinkAbout195 Kent LaneFINAL INSPE TIONS: l3wilding APPLICATION FOR BUILDING PERMITPlumbing HVAC i F Date: 8- 2r—qz— Sprinkler 195 KENT LANE Electric Zoning Estimated Cost 9l S-40 Affidavit i Np,2 018 7 Permit Fee$ Eng. Dept. o Occupancy Fee $T.CxD Fire Dept. COMPLETE RED BOXED AREAS. Total Fees YZB, croHealthDept. TYPE OR PRINT ONLY vD Approved for CO; re SIGN ON REVERSE SIDE. d bAdditionalCost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The and rsigned, he eby applies to do work according to the following specifications: Job Location , t Lot No. Side of Street Zone Applicant Tel. # _413-2/f/ Address ip Gyo/dJ Lic.#STF T CITY STATE Owner Address J''S AMW F49f0VA..o fo C-L Architect Address Size New Area: Ft. Front Overall Ft. Deep Overall 32,Total Area 2G3` #Garages L Size of Lot Dist. from Street Line G t Bathrooms _Rooms 1st 2nd 3rd Purpose of this Permit City Water Well 0 Septic D Sewer Use Group y Construction Type Approved by Date "`q BD1A 11/88 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side ya d lines and req i ed dist s from all other z ne and is located in a zone in which this building and its use is allowed. Signed I hereby apply for a Certificate of Occupancy for the work described in this applicati for ermit. Signed DO NOT WRITE BELOW T INE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# -I I Ito Inspections: HVAC Permit#eg54 1 Inspections: Electrical Permit# 3 } Inspections: Sprinkler Permit# Inspections: Location of job AFFIDAVIT Additional Fee ...$.310 . 0 0 State of Connecticut County of Hartford ss. I. N y.... 1 1.... .... Owner gen for building erected underf. ctor Permit No.2 a 1.8.7 ... ............ ..... issued by the Dep't of Building of the Tbwn of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized under said It di not exceed ost curren acce ted BOCA value of .1361069 . 00. . . . . . . . . . . . . . . . . . . . . . . . . gned' A. ..Subscribed and sworn to before me this ... .... .,R.th. .. ...da f ,.ISO embember• • • ••••• .•f D.19 . ..9 2 Estimate Cost: n 5 9 n n_ n 0 Difference: $ o;;• C J /` Inspection / Approval Date By Appl Code Description Due Whom Code Comment 92-20187-B 91,500 BO1 FOOTING 08/31/92 003 A B02 FOUNDATION 09/03/92 003 A B05 FIREPLACE/CHIMNEY 09/25/92 003 A B03 FRAMING (ROUGH) 09/28/92 003 D NEEDS JOIST HANGERS B03 FRAMING (ROUGH) 10/08/92 003 A REINSPECTTION OK E03 ROUGH 10/08/92 003 A P03 ROUGH 10/08/92 003 A H03 ROUGH 10/08/92 003 A B04 INSULATION 10/09/92 003 A E01 SERVICE 10/09/92 003 A RELEASE ISSUED OK B10 FINAL 11/19/92 005 A APPROVED FOR CO BLDG/VERBAL OK ENG/PLNG 92-8546-H 5,000 92-9126-P 5,000 92-12372-E 4,400 Total Est Value 105,900 Inspection / Approval Date By Appl Code Description Due Whom Code Comment 92-20187-B 91,500 B01 FOOTING 08/31/92 003 A B02 FOUNDATION 09/03/92 003 A B05 FIREPLACE/CHIMNEY 09/25/92 003 A B03 FRAMING (ROUGH) 09/28/92 003 D NEEDS JOIST HANGERS B03 FRAMING (ROUGH) 10/08/92 003 A REINSPECTTION OK E03 ROUGH 10/08/92 003 A P03 ROUGH 10/08/92 003 A H03 ROUGH 10/08/92 003 A B04 INSULATION 10/09/92 003 A E01 SERVICE 10/09/92 003 A RELEASE ISSUED OK 92-8546-H 51000 92-9126-P 51000 92-12372-E 41400 Total Est Value 105,900 Dwelling 2,634 97,932.12 Basement 1,160 11,542.00 Garage 912 10,716 .00 Smoke Det 3 225.00 BOCA Value 136,069 .09 Difference 40)30,169 .09 3 CERTIFICATE OF OCCUPANCY CHECK LIST Applicant Devcon, Inc. certificate of Occupancy Address 609 Farm. Ave. ,, Htfd. 06105 Bldg. Permit No. Z3.,2 1 "7 Lot No. 9 , (19 5 Kent Lane) Date Reviewed f- z 0-3iv Project HEATHER FARMS Reviewed Date Submitted 11-18-92 Approved enie z As required in the Zoning Ificate-of-Occupancy shall beAsrequiredintheZoningr issued until grading plans have been complied with and approved by the Town Enaineer. The minimum requirements shall include: r Ancroved Denied N/A 1 . P_oereved building permit plan. 2 . Finish grading per approved building permit plan. 3 .Site work; i .e . trees, c;ru_^.S. dumosters, required park-inc, 4 . utility location a . Sanitary sewer b. foundation drain c . electrical & t`_e: o.ne G. wa r e . other 5 . Sewer connection charce paid. 6 . Approve iate cent i f icat i cn Jf/;' G-I'r' i3v&'/ ' 7 . Bonding C 8 . Planning & Zoning 06 per PA 2 C 1- 7 Sewer Permit No. Pavement Excavation No. COMMENTS: CERTIFICATE OF OCCUPANCY CHECK LIST Applicant Devcon, Inc. Certificate of Occupancy Address6 army ve, Htfd 06105 Bldg. Permit No. Lot No. 9 (19 5 Kent Lane) Date Reviewed Project HEATHER FARMS Reviewed 717 Date Submitted 11-18-92 Approved enied 07 l I As required in the Zoning Regulations, no Certificate-of Occupancy shall e issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1 . Approved building permit plan. 6z 2 . Finish grading per approved% building permit plan. 3 . Site work; i .e . trees , shrubs , dumpsters, required parking, 4 . Utility location a . Sanitary sewer b. foundation drain c . electrical & telephone d. water e. other 5 . Sewer connection charge paid. 6 . Aoorooriate certification 7 . Bonding i C 8 . Planning & Zoning Sewer Permit No. Tv, S" Pavement Excavation No. COMMENTS: pp BUlLLUNU VZW11T C:ri.l.l lilt A licant Anthony Bianca Sr. Building Petmit No.8-7 Address 609 Farmington Av. , Hftd Date Submitt d p -M. ) Lot No* xala;tLaRReviewed b Pro3 ec ate In accordance with the Su ivisio prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include : Approved Denied N/A nrw 1. Name, address & phone number of owner/ applicant. Q 2. Name, address & phone number of plan preparer. 3. Zoning information - i.e. zone, open space, floodway, etc. 4 . Plot plan at 1" = 40 ' scale. a. Subdivision reference, abutting properties, etc. b. Easements of record. c. Lot description, bearings, distances, building lines, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate. e. Building location with dimensions. Elevations of proposed finish floor, garage floor & center line of road at driveway. f. Elevations Qf crramLity drainage systems, sanitary & fo undation drain t the house and the g. Tentative utility location gas, electric, water, etc. h. Title block with name and address of preparer, date appropriate certification, live seal and signature. 5. Sedimentation and erosion control. 6. Special Planning & Zoning, Inland/Wetlands considerations. (Plans on file w/Town Clerk) BUILDING DEPT. PZC IWA/CC WPCA OTHERS A COMMENTS: PERMIT # DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT la Application is hereby: TOWN OF SOUTH WINDSOR BUILDING INSPECTION DEPT. APPROVED DISAPPROVED 1540 SULLIVAN AVENUE 644-2511 Ext. 230 Date Building Inspector Application must be printed or typed 1. LOCATION OF JOB FEE SCHEDULE No . Street 1 0 - $19000 -10.00 Floor Apt . No. Over $1,000 - 10.00 p e r $1 ,0 0 0 o r 2 . OWNER y-,77,,,,Y fraction thereof 3. ADDRESS p Q /`.xiez lzl) 4. APPLICANT 5 . ADDRESS c7%:, a '?JG-L -Zl.7GD c1 6. ESTIMATED COST $ woe 7 . IS THIS A CONTRACT COST 9 N 8. FEE ENCLOSED $SUN 9. TYPE OF BUILDING: 01/ i/ RESIDENTIAL COMMERCIAL 10. TYP OF JOB: Original Installation Alteration/Addition/Repair BD 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11. LOCATION OF JOB 19,S NO. STREET APT. NO , 12 . TYPE OF INSTALLATION 13 . SIZE OF MAIN F E E D E Rf Q -, 14. NO. OF LIGHT LOOPS g 15 . NO. OF HEAT LOOPS 16 . NO. OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS 18 . NO. OF HEAT CIRCUITS- / 1 19. NO. OF POWER OUTLETS 20 . NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS 22 . NO. OF POWER CIRCUITS 23 . NO. OF LIGHT CIRCUITS_ 24. SIZE OF HEAT CIRCUITS_ZS/ 25 . NO. OF MOTORS 26 . NO. OF PANELS- / 1 27 . TOTAL WATTAGE 28 . NO. OF POWER FEEDERS 29 . NO. OF SWITCHES 30. A/C LOAD 31. SIZE OF POWER FEEDERS 32. NO. OF FIXTURES_ 33. TOTAL HORSEPOWER 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : LICENSE NO.SIGNATURE OF APPLICANT DATE PHONE NUMBER: rs:--'s•''t,;r --- +-^.-.+.-^' "".+"R T"r-;'"r 4"1 r,'P S z''^^-°P4 r'•T..4!!"R9{C-s-..._F...,.--..-. s.n+v.;wv*T' Lot No.No. Building Permit Temporary S rvice immanent Service Pursuant to Permit No.9 2- This Certifies that the Electrical Work for which the above named Permit was granted has been duly inspected and is hereby approved. OwnerElectrician 1 Street Building Inspector PERMIT NO. 0 ii DEPARTMENT DECISION APPL I CAT ION FOR Application is hereby : PLUMBING PERMIT TOWM OF SOUTH WINDSOR APPR VED DISAPPROVED BUILDING INSPECTION DEPT. ld 644-2511 Ext. 230 aL Date Building Inspector Application must be printed or typed. 1. LOCATION OF JOB: q 5 LLrANL D ! FEE SCHEDULE 2. OGINER: t14MVC O 0 - $19000 -10.00 3. ADDRESS:AMID& nop Over $1 ,000 -10.00 14M 660iper $1 ,000 or 4. APPLICANT: V GQA TL,fraction thereof pL'[5. ADDRESS: n jU,JU f—Aw Gmne- f(-7 6. EST. COST: $ 7. IS THIS A CONTRACT COST? ES NO 00 8. FEE ENCLOSED: $ 7 9. TYPE OF BUILDING: RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: ORIGINAL ALTERATION INSTALLATION ADDITION REPAIR BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB:L pi- GENERAL PLUMBING 12. KIND OF INSTALLATION: P13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS `-STYLE- 15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS__ 16A. NO. OF SHOWERS 1 17. NO. OF LAVATORIES 18. NO. OF SINKS k 19. DISPOSAL_ 19A. DISWASHER J_ 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACK S----SIZE f 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND lx kv A 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS 32. REMARKS AND FURTHER DETAILS S 1 N WATER HEATER 33. TYPE WQ-I mr p©G 34. MANUFACTURER TANKS SAFETY DEVICES TERfPERATURE 35. CAPACITY 40 39. RELIEF VALVE d 36. TEST PRESSURE J bo LBS. 40. MANUFACTURER_ wo-h 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE S 38. TYPE I w C ss 42. MANUFACTURER JQ LICENSE NO. DATE SIGNATURE OF APPLICANT PHONE NO. SYc, D- FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: 16-7 NO. TOWN OF SOUTH WINDSOR EST.COST:Wlpcp 0 BLDG. PERMIT NO.1540 SULLIVAN AVENUE FEES, SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 0 - $19000 - $10.00 1000 or fraction LOCATION OF BUILDING 9 4ent Lvo-*w Y thereof - $10.00 G-t hti 10 1 t0AJ f OWNER ADDRESS TOWN PHONE NO. RhU 9)AWZ M 0 pt-M 3 DL HVAC CONTRACTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL P\ A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC_4L_ WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: O.IL.-GPMja GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE_ OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION_ TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) HEAT LOSS SHEET MUST ACCOMPANY AP ICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): WQkl AJ CA We i 1wc toiA') T GROSS HEA NG CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE F INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN (BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT): TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: 091N0 lag f, STATE LICENSE - NAME & TYPE #bAT9 = SIGNATURE OF APPLICANT AQ 6— 9— L APPROVED DATE BD 4A 11/88 I - B - R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The Hydronics Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE-F. DATE COL.A COL.B COL.C COL.D COL.E COL.F COL.G 1 ROOM tL O H L W H L W H L W H L W H L W Design Water Temp. ROOM DIMENSIONS, FT.I- V BTUH per Foot of 3 LENGTH EXPOSED WALLS,FT. Q Radiation Selected d WINDOW AND OUTSIDE DOOR AREA IL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION ROOM LIN.FT.OFTable9, Line 3 x HI TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED Gott m of table used f r Line 5) 7 CEILING CONSTRUCTION C Table 9, L x W) B FLOOR CONSTRUCTIONt O Table 9, L x W or Lin Ft) E 9 COLD PARTITION CONSTRUCTION F Table 9, L x H)G 10 _C 1 We11(With Openings) is C 2 W ells I W ith Openings) J H 3 Wells(With Openings) or Ent.Hall f. 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 1? TOTAL BTUH AT DESIGN TEMP. DIFFERENCE K COL.A - -_ -__ COL.B COL.H COL. 1 COL_J - COL.K COL.L TOTAL BTUH TOTAL OF BUILDING RADIATION1ROOM tL AT SELECTED O H L W H I L W H L W H L W H L W DESIGN TEMP.- 2 ROOM DIMENSIONS, FT f DIFFERENCE U 3 LENGTH EXPOSED WALLS, FT Q A WINDOW AND OUTSIDE DOOR AREA W BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9,Line 3 x H) TOTAL 20% 6 TYPE OF GLASS Bolt m of table used for Line 51 I--- - tFOR CONCRETE FLOOR ON7CEILINGCONSTRUCTIONGROUNDORFILLATTable9, L x WI GRADE LEVEL,USE LINEAR B FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE Table 9,L x W or Lin Ft) 9 COLD PARTITION CONSTRUCTION Table 9,L x H) 10 r 1 Wall(With Openings) O Walls(With Openings) G X 3 Wall&(With Openings)or Ent. Hall 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 1? TOTAL BTUH AT DESIGN TEMP DIFFERENCE This form Is availebie from The Hydronlcs Institute. 35 Russo Piece,Berkeley Heights,N J 07922 FORM 1503 17 e = B= R CALCULATION SHEET 1503 (Modern Method) The Hydr nice Institute,35 Russo Place,Berkeley Heights,N.J.07922 , WNER •^ r 1"'* /'•'.. ADDRESS rF 'Wt ii/c'+OQ I DESIGN TEMPERATURE DIFFERENCE F. DATE COL.A COL.B COL.C - COL.D COL.E CO .F COL.G 1 ROOM i Ai. k ryr a a v O H L W H L •''W H L W H L W H t' yy Desiyn Water Temp. 2 ROOM DIMENSIONS,FT. V r -, , l BTUH per Foot f CG3LENGTHEXPOSEDWALLS,FT. Q J Radlatl n Selected 4 WINDOW AND OUTSIDE DOOR AREA J 4Y `!,N TUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION lVp00 n( Teble 9,Line 3 x HI ROOM LIN.FT.OF j li D v 7 Q GO C O d TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED Bolt m of tab QlusedforLine5) Q G QO G A410 a-{O Q d 7 CEILING CONSTRUCTION C Table 9,L x W) Q G g FLOOR CONSTRUCTIONt D Table 9,L x W r Lin. Ft) E 7tf-aG 9 COLD PARTITION CONSTRUCTION Table 9,L x H) C G a G all 710c1Wall(With Op nings) Q GQ f1 H G 2 Walls(With Openings)D x 3 Wells(With Openings)or Ent Hall J11TOTALBTUHAT70FTEMP. DIFFERENCE* QLTQd Q 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE GO O O OO Z' L COL.A COL.B COL.H COL. I COL.J COL.K COL.L TOTAL BTUH T TAL 1 ROOM l OF BUILDING RADIATI N IC AT SELECTED O H 1-01 WSJ H 4 W H L W H L W H L W DESIGN TEMP.• fiDIFFERENCE2ROOMDIMENSIONS,FT. i 3 LENGTH EXPOSED WALLS,FT. e WINDOW AND OUTSIDE ODOR AREA LLA7C/BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9,Lin 3 x H) 0 TOTAL 2 6 TYPE OF GLASSY IS tt rn f table used f r LIns 5) x I FOR CONCRETE FLOOR Oh7CEILINGCONSTRUCTION i(Table 9,L x WI GROUND OR FILL AT GRADE LEVEL,USE LINEAr FLOOR CONSTRUCTION? FEET OF EXPOSED EDGE Table 9,L x W or Lin.Ft) 9 COLD PARTITION CONSTRUCTION Table 9,L x H) 10 ,c 1 Wall(With Openings) So2 Walls(With Openings)e x 3 Walls(With Openings)or Ent Hall a 11 TOTAL BTUH AT 70F TEMP.DIFFERENCE• Q 12 TOTAL BTUH AT DESIGN TEMP.DIFFERENCE 3 049 FORM 1503 B= RCALCULATION SHEET 1503 (Modern Method) The Hydronks Institute,36 Russo Plan,eaWay Heights,N.J.0797 OWNER ADDRESS pESIpN TEMPERATURE DIFFERENCE F. DATE COL.A COL.B j COL.C COL.D C COL.F COL.6 1 ROOM J V2 O L W H L G WO, H L.o W H L H LQ WO Desl/e Water T mo. 2 ROOM DIMENSIONS,FT. I' O ULU BTUR eer F of f3LENGTHEXPOSEDWALLS, FT. Q Radistlon Select d 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUM BTUH BTUH5WALLCONSTRUCTION tTable9,Line 3 x H) 4 7 // Q v 0 d OF I(/ Q G d TOTALS RADIA ROOM LIN.FT.OF 6 TYPE OF GLASS FROM LINE 12 SELECTEE' 1 3BottomoftableusedforLine5) 1XIO d ' 7 1 CEILING CONSTRUCTION C 2zTable9,LxW) g FLOOR CONSTRUCTIONt D Table 9, L x W or Lin. Ft.) 9 COLD PARTITION CONSTRUCTION Table 9, L x H) F 10 _c t well(with openings) o a0' D ao • zd GSpp D e 2 Wells(With Openings) X W7J 1 U3Wells(With Openings)or Ent.Hall l'- 11 TOTAL BTUH AT 70F TEMP. DIFFERENCE• O QD J 12 1 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE Q Q Q Q QQ U 7 QQ K COL.A COL.B COL.H COL.1 COL.J COL.K COL.L TOTAL STUH TOTAL1ROOMOFBUILDINRADIATION AT SELECTEDONLWOHLWHLWHLWHLWtt>n="TEMP.• x G 2 ROOM DIMENSIONS,FT. F' DIMERENCE V 3 LENGTH EXPOSED WALLS,FT. Q JLof 4 WINDOW AND OUTSIDE DOOR AREA U.U f BTUH BTUH BTUH BTUH BTUH5WALLCONSTRUCTION( Table 9,Line 3 x H) INCRSEASE BATHROOMO U d TOTAL 209E B TYPE OF LASS B ttom of table used for LIns 5) 7 I CEILING CONSTRUCTION tFOR CONCRETE FLOOR ON Tabl 9,L x W) Q QROtMD OR FILL ATddGRADELEVEL.USE LINEARBFLOORCNSTRUCTIONtFEETOFEXPOSEDEDGE Tebl 9,L x W or Lin.Ft.) 9 COLD PARTITION CONSTRUCTION Table 9,L x H) 10 c '/Well(With Openings) o 2 Wells(With Openings)x Z O d• 3 Wells(With Openings)p ngs) r Ent Hall f. 11 TOTAL BTUM AT 70F TEMP.DIFFERENCE' f? 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE DD FORM 150? c FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: NO. 110 TOWN OF SOUTH WINDSOR EST.COST:90. BLDG. PERMIT NO.1540 SULLIVAN AVENUE FEE SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 0 - $19000 - $1$.00 Q 14*14 1000 or fraction LOCATION OF BUILDING /5 j4W thereof - $10.00 c ro Ervr G uru WJAV$04 . 0608 OWNER ADDRESS TOWN PHONE NO. vo_ ro"40110 9-X&Y- bm_ 4"40 Or 735 HVAC CONTRACTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL A/C COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR_ UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE b LOCATION: INSIDE_ OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION_ ADDITIONAL RADIATION_ TOTAL RADIATION_ DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS (BTUH) HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE°F INSIDEJ°F DIFFERENCE /b OF TOTAL HEAT GAIN (BTUH) 2-7 4640 HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): X doh} 711 r. Al9- vx-- GinoVS G Fes. TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN F.XHAUSE EQUIPMENT) : TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: 1W6r,4Lf,#q Jf Al 4 *y CdrVtr;T6 1:4t& tC, &9 C4A/dtVDAIAOt VA_30 3 i8 S I s o STATE LICENSE - NAME & TYPE #DATt SIGNATORE OF APPLICANT J a- t0 6 a f APPROVED DATE I - 8 - R CALCULATION SHEET 1503 (Modern Method)Copyright 1971 by The Hydronics Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL A COL.@ COL.C COL.D COL.E COL.F COL.G 1 ROOM E O H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, F T.1- U @TUN pv F Olaf3LENGTHEXPOSEDWALLS.FT. Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA LL STUN STUN STUN BTUH @TUN 5 WALL CONSTRUCTION Table 9, Line 3 x H)ROOM LIN.FT.OF TOTALS RADIATION6TYPEOFGLASSFROMLINE12SELECTED 1B ttom of table used f r Line 51 7 CEILING CONSTRUCTION Table 9. L x W)C 9 FLOOR CONSTRUCTIONt 0— Table 9, L x W or Lin. F t) E 9 COLD PARTITION CONSTRUCTION liable 9. L x HI F 10 c 1 Wall I W Ith Openings)O G 0 Hc; 2 Walls(With Openings) D XJ 13WellsIWIhOpenings)or Ent.Hell 11 TOTAL UTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K L COL.A _COL.B COL.H _- COL.1 COL_J _ COL.K COL.L TOTAL BTUH TOTAL1ROOMOF@UILDINRADIATIONQATSELECTEDOHLWHLWHLIWHLWHLWDESIGNTEMP.* 2 ROOM DIMENSIONS. FT DIFFERENCE U 3 LENGTH EXPOSED WALLS, FT 4 WINDOW AND OUTSIDE DOOR AREA LL 5 WALL CONSTRUCTION @TUN BTUH STUN BTUH STUN INCREASE BATHROOMTable9, Llne 3 x HI TOTAL 20% 6 TYPE OF GLASS Bottom I table used tot Line 5) 7 CEILING CONSTRUCTION IFOR CONCRETE FLOOR ON Table 9. L x W) GROUND OR FILL AT GRADE LEVEL,USE LINEARgFLOORCONSTRUCTIONtFEETOFEXPOSEDEDGE ITable9. L x W or Lin Ft) 9 COLD PARTITION CONSTRUCTION ITabla 9. L x H) 10 c 1 Wall(With Openings)G 0 2 Wells(With Openings!X 3 Wells(With Openings) or Ent Hall r 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE This form Is avaiIeble I m The NydrOnlcs Institute 36 Russo Pieta,Berkeley Heights,N J 07922 FORM 1503 01-01-80 60601903. 15 DETAILED REPORT FOR ENTIRE HOUSE Preoared For: Prepared By: Robert Giglio D. J. Svmolon 195 Kent Lane Kasden Fuel Company South Windsor , CT 06074 Job Name: Giglio EXPOSURE GLASS NORTH SOUTH EAST WEST NE/NW SE/SW HORZ. TOTAL AREA 13511 1351' 3011 4511 0 | 01. 0 3451' COOLING | 391591, 492391. 1 ,692| 2,538| 01, 0 | 01' 11 °628| HEATING | 79563 7,5631' 146811 21521 | 011 0 | 01. 19,3291. BELOW WALLS NORTH SOUTH EAST WEST NE/NW SE/SW GRADE TOTAL AREA 660| 639 | 5141 499 . 011 0 : 01. 2131211 COOLING | 1 ,060 | 1 ,0261' 8251' 801 | 01 0| 01, 3,712 | HEATING | 393671 31260 | 2,622 | 2,546 | 0 | 0 | 011 11 ,7961, DOORS NORTH SOUTH EAST WEST NE/NW SE/SW TOTAL AREA 2111 421, 01, 01, 01, 01,631' COOLING 292 ( 585 | 0 | 0 | of, 0 |877 | HEATING | 9291 1 ,8581 01. 0| 0 | 01,2.788| FLOOR AREA COOLING HEATING 2544 0 | 6,203 CEILING AREA COOLING HEATING 2544 3,742 ( 6,378 MISCELLANEOUS COOLING LOADS Peop1e Sensible Load 0 Latent Load 5,855 Lights & Appl . Load 0 Latent Safety Btuh 0 Ventilation Load 0 Duct Heat Gain 0 Infiltration Load 11726 Sensible Safety Btuh 0 TOTAL SENSIBLE LOAD 21 ,685 TOTAL LATENT LOAD 5,855 Summer ACH 0. 23 Temp. Swing Mult. 1 . 00 Total Cooling Load 27,540 BTUH Or 2. 30 Tons *** MISCELLANEOUS HEATING LOADS Infiltration Load 124948 Ventilation Load 0 Duct Heat Loss 0 Safety Btuh 0 Winter ACH 0. 50 Total Heating Load 59,442 BTUH *** 01-01-80 60601903. 15 SUMMARY REPORT Prepared For: Prepared By: Robert Giglio D. J. Symolon 195 Kent Lane Kasden Fuel Company South Windsor , CT 06074 Job Name: Giglio DESIGN CONDITIONS for South Windsor OUTDOOR INDOOR SUMMER WINTER SUMMER WINTER Dry Bulb 95 5 75 70 Wet Bulb 75 62 Daily Range 21 Daily Swing 3. 0 Latitude 41 Elevation 700 Safety Factor (%) 0 Latent Factor (%) 27 Sensible Room Heating Heating Cooling Cooling Name BTUH CFM BTUH CFM First Floor 33,089 463 101688 540 Second Floor 26,353 369 10,997 555 59°442 831 21 ,685 1 ,095 HEATING DELTA T 65. 0 COOLING DELTA T 18. 0 NOTE: *** Calculated Airflow is based upon load requirements. Verify that airflow calculated is compatible with selected equipment requirements. ***