Loading...
HomeMy WebLinkAbout19 Cardinal Way (3)C SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 19 CARDINAL WAY LOT_#32 Reviewed By Engineering) CLARK REALTY, INC. Date ReviewABUI prove nied 658 ELLINGTON ROAD,SOUTH WINDSOR,CT Reviewed By anning) BP_#_25547_ Ph_##_(203)528-6054 Date Review 9P' pprove / enied Date Submitted 08/31/98 F G PE In accordance with the Zoning and/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include: Approved Denied N/A 1. Name, address & phone number of owner/applicant 2. Name, address & phone number of plan preparer 3. Zoning Information - i.e. zone, open space, floodway, etc. 4. Plot Plan at 1" = 40' scale a. Subdivision reference, abutting properties, etc b. Easements of record l C. Lot description, bearings, building lines, distances, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate e. Building location with dimensions. Elevations of proposed finish floor, garage floor & centerline of road at driveway f. Elevations of gravity drainage systems, sanitary foundation drain at the house and the street g. Tentative utility location (gas, water, electric, septic system, etc.) h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements. (P.E. & L.S.) 5. Sedimentation and erosion control 6. Special Planning & Zoning, Inland/Wetlands considerations (Plans on file w/Town Clerk) COMMENTS: DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby:TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit# APPROVED 1540 SULLIVAN AVENUE 644-2511 ext.230 Date Building Inspector Application must be printed or typed Location ofjob FStreet No. Street Lot No. FEE SCHEDULE Floor Apt.No. 0 - $1,000 - $12.00 Over $1,000 12.00 per$1,000 OWNER or any fraction thereof ADDRESS zaj l 2 OWNERS PHONE# r, 2 L1q O/3g APPLICANTOWSfADDRESSD l S ESTIMATED COST$ 40.0 IS THIS A CONTRACT COST? YES NO FEE ENCLOSED E OF JOB:OR-CO Original Installation Alteration/Addition Repair Revised 11/95 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL BUILDING PERMIT APPLICATION YES / NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY 4ez INSTITUTIONAL FACTORY STORAGE ENGINEER'S NAME PHONE GARAGE MIXED USE ADDRESS CITY STATE ZIP Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF MAIN FEEDERS AND RATING OF WIRE USED C>-26 D NUMBER OF METERS ! NUMBER OF DISCONNECTS AND RATINGS a NUMBER OF PANELS REMOTE DISCONNECT REQUIRED?YES(/NO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES --),0 NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES o)-S NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPERATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. NAME STATE LICENSE NO. TYPE SIGNATURE OF APPLICANT PHONE NO.S2d -9?c:J DATE L INSPECTOR C., DI;TE TIME J LOCATION p5 q ' 9 INSPECTION: CODE: RESULT(D/A) : BUILDING: ELECTRICAL: 6640- PLUMBING: HVAC: OTHER: DEPARTMENT DECISION PERMIT# APPLICATION FOR PLUMBING PERMIT Application is hereby:TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit# APPRO 1540 SULLIVAN AVENUE 3r 1 644-2511 ext.'230 Inspector4DatewildingInspector Application must be printed or typed Location ofjob 6r Street No. Street Lot No. FEE SCHEDULE Floor Apt.No. 0 - $1,000 - $12.00 Over $1,000 12.00 per$1,000 OWNER or any fraction thereof ADDRESS!/' r "'- GL OWNERS PHONE# APPLICANT At 0* N St4 ADDRESS 6r&a4r 0 4* ESTRvLkTED COST$ 00tr IS THIS A CONTRACT COST? U YES NO FEE ENCLOSED 24 OR-CO TYPE OF JOB: c---Off ' Installationginal Alteration/Addition Repair Revised 10/96 APPLICATION FOR PLUMBING PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION YES / NO RESIDENTIAL BUSINESS CURRENT USE AND OCCUPANCYASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCY GYlic--EDUCATIONAL INSTITUTION FACTORY ENGINEER'S NAME PHONE STORAGE GARAGE ADDRESS MIXED USE CITY STATE ZIP Other please specify) TYPE OF INSTALLATION ii2 SIZE OF MAIN DRAIN NO. OF TOILETS -STYLE NO. OF URINALS STYLE NO. OF BATHTUBS_NO. O SHO RS_/ NO. OF LAVATORIES _ NO. OF CONDUCTORS SIZE NO. OF STACKS SIZE AREA OF ROOF NO. OF CATCH BASINS NO. OF FLOOR DRAINS NO. OF OTHER FIXTURES/KIND /b/7 M1 ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW YES/NO SIZE OF WINDOW Z IF NONE C.F.M. OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANI SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER WATER HEATER TYPE MANUFACTURE TANKS SAFETY DEVICES TEMPERATURE CAPACITY RELIEF VALVE TEST PRESSURE WORKING PRESSURE PRESSURE RELIEF VALVE TYPE MANUFACTURER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN. BUILDING CODES IN THE PERFORMANCE OF SUCH W- NAME STATE LICENSE NO. TYPE NATURE OF APPLICANT PHONE NO. `1 j DATE, 60R OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE:ga4103401TOWNofSOUTHWINDSOREST•COST: WIT M+ 1540 SULLIVAN AVENUE FEE oZ SOUTH WINDSOR. CT 06074 FEES: 644-2511 - Ex t. 230 0 - $1.000 - t 1000 r frac t ion, ; -40"TION OF BUILDING vzz- 1-3 12 G thereof( ajw ADDRESS TOWN PHONE NO. VIVA4 CONTRA -8 ASDJLESOS TOWN PHONE NO. TYPE,OF SYSTEM: KFAT-ING TYPE OF BUILDING: RESIDENTIALA/C COMMERCIAL _—VENTILATION - BUSINESS _ INDUSTRIAL IF WATING: S I LOW FB.ES.SU tB LIIIIT =S. BIGIi PRESSURE LIIKIT LBS. HARM AIR t* 7' —VNWXR (INCLUDING HOOD COAL BURNING STOVE) TYPE OF FUEL: OZL-GSM_, GAS WUT2 ELECTRIC WpOD COAL 011L TAM —;,Z 6 L5 SIDE OUTSIDE CAPACITY E!C' 9TNGt 0 ADD I'TTO TAL RADIATION TOTAL BAD IATION F INSIDES _ F "FIFFERENCE_ F SAL HFAIT.`LO". S OWN) BEAT LOSS SHEET M1JST ACCOMPANY APPLICATION) QEwS " I'NG FT'It1T INCLUDING MAKE 6 MODEL NO.): 2hLXg" f- f 1,7Z - e:6ei GKOS`S 13EA A G `CAFACIT'Y WUT1-8 ) NET RATING OUTPUT-BTUH IF &ZIR CONDITION-NG,; DESIGN OUTSIDE_'F INSIDE_'F DIFFERENCE F TOTAL BEAT LAIN (BTUR) B,BA'T GAIN Sam MUST ACCOMPANY APPLICATION) E.QUE INCLUDING MAKE A MODEL NO.): COOLING CAPACITY BTUH NWT,1 TION: IMSM, 88 ALL AIE"8ANDLING EQUIPMENT (INCLUDING KITCHEN EX HIUSE EQUIPMENT): FRESH AIR INTAKE (CFM evsigntd heiveby appl;Ass for a permit to perform the following work and is to comply local or as and State of Conn. Building Codes in the performance of such work. I'sma PESCRIPT"N,0 WORK: stl U SWE.'LICENSE - NAMES 'TYPE DATE 7IpUTURE OF APPLICANT7 APPROVED' DATE n aA 11/88 Y , LCULATION SHEET 1503 (Modwn Method) Ceoyrlght 1971"The Hydeo•Iss In.tltwlo ADDRESS , DESIGN TEMICRATVA[01FFILI%ENCt 4?4r. 1 A A COL.0 COL.C COL.O COL.19 COL.' COL.G 127 Catlin Water Tern2CHLWHLWNLWHLWHLW 2 ENS IDNS.FT. U O O7VAI STUN per feet e1 Radlatlew Safetlada xPOSEO WALLS-FT. Olt HD OUTSIDE DOOR AREA a 9 STUN STUN STUN STUN STUN STRUCTI N 3u Root* LIN.FT. OF6e7aH{ O / tf/ Q d TOTALS RADIATION L ASf IROM LINE 12 S[L[CTEO i't ataplarwdforLineS1 a iNsTAUCTION c So i W1 D J /d- L O o 0 9sTRucT1oN1 Ern Zyf9'WorLin•Ftl TITIp4 CONSTRUCTION F G Eyo With Ovem"O'l 0 with Oo.n,ny.l a z 7 7 1 101111%Ooen:n J Q 1 or Ent.Nall f DIJHATTOFTEtA. DIFFERENCE- Q D K 3 2DJHATDESIGNTEMP.DIFFERENCE L o o 1 F COL.A - COL.S COL.H COL.1 COL.J: COL.K COL.L 1 TOTALA—TOTALUTUM F BUILDING RADIATION AT SELECTED 2 _OL K EMP!O H L W N L W N L `. W H L W N L W DESIGN TpIFFER[NCt31ENSIONS.FT 6' a y. ; uOSEOwALLS.fT. N0 OUTSIDE DOOR AREA 1 S w •{ STUN TUN STUN :_ TUN STUN IT04 :TRUCTIOW Q - / 1 - INCREASE BATHROOMST 'Ltrw 2 H) v U tii O O V V QO 157 4 C7 S TOTAL 20K- rss, ASS 7 CEO fN 1e used f r Line 51 IFOR CONCRETE FLOOR ONITINSTRUCTIONN. GROUND OR FILL ATI7OvOe.?D oO S O GRAOE LEVEL.USE LINEARIaISTRUCTIONIFEETOFEXPOSEDEDGE av arLw ft CONSTRUCTIONs eninOrl O 7— goo 0 sA{W-th Ooen.nie! a x Ih ODM.ntsl or Ent Hall AT TOF TEMP.OIFFE1tENCE• 4 0 7m 4T DESIGN TEMP.DIFFERENCE 3 Za. r1ietUaNid, nice Institute.35 Russ*Pl . AAA lso ete Sartiley Nsyht>L N.1 0)it12 DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby:TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permit# APPROVE 1540 SULLIVAN AVENUE v 64 644-2511 ext.230 Date Building Inspector Application must be printed or typed Location ofjob 12 z Street No. Street Lot No. FEE SCHEDULE 2 Floor Apt.No. 0 - $1,000 - $12.00 Over $1,000 12.00 per$1,000 OWNER or any fraction thereof ADDRESS J!"' OWNERS PHONE# --;2 e2 1p APPLICANT F ir/ C ADDRESS 3/O ZlUr`i l •' . B TY ESTIMATED COST $ 0 C IS THIS A CONTRACT COST? YES NO FEE ENCLOSED $ 2. OR-Co TYPE OF JOB: Original Installation Alteration/Addition/Repair Revised 11/95 I APPLICATION FOR HVAC PERMIT(Continued from reverse side) TYPE OF SYSTEM TYPE OF BUILDING HEATING RESIDENTIAL y A/C COMMERCIAL VENTILATION INDUSTRIAL HE G LOW PRESSURE LIMIT LBS.HIGH PRESSURE LIMIT LBS. HYDRO WARM AIR UNIT RADIANT BEA EXISTING RADI ADDITIONAL RADIATION TOTAL RADI N DESIGN TE SIDE F INSIDE F DIFFERE F TO HEAT LOSS(BTUH) HEAT LOSS SHE ST ACCOMPANY ICATION) DESCRIBE ALL HEATING EQUIP INC G MAKE&MODEL NO.) GROSS HEATING CAPA INPUT—BTUH) NET RATING (OU BTUH) TYPE OF FUEL OIL—GPM GAS—INPUT ELECTRIC—KW OIL TANK SIZE&LOCATION INSIDE OUTSIDE CAPACITY LPG TANK CAPACITY AIR CONDITIONING DESIGN TEMP. OUTSIDE Fr JF INSIDE_ZQ F DIFFERENCEZZ_F TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMP APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE&MODEL NO.) wo Te eGdf 4,4fNA)PLE c% TONNAGE 7 COOLING CAPACITY(BTUH) VENT ATION D ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUS MENT) TOTAL SIZE OF M(CFM) FRESH AIR INT PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN. BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. STATE LICENSE—NO. NAME&TYPE S NATURE O PL PHONE NO. -2 eF2— 7 T f 2 DATE %— 7— 7'' Chin J DETAILED REPORT FOR ENTIRE HOUSE Prepared For : Prepared BY: Clark Realty RP 658 Ellington Road R&E Heating & Cooling So Windsor Ct 06074 Job Name: 243-032 EXPOSURE GLASS NORTH NE/NW EAST SOUTH SE/SW WEST HORZ . TOTAL w-_____________-__-_-_--_____-__..___--_--______w__________---__________-_-_ AREA 158 , 0 ; 49 : 200 ; 0 ; 116 : 0 ; 523 COOLING ; 2 ,121 ; 0 ; 2 ,128 : 4 ,285 , 0 ; 5 ,037 : 0 ; 13 ,570 HEATING ; 6 ,339 : 0 ; 1 ,966 ; 8 ,024 , 0 ; 4 ,654 : 0 ; 20 ,983 BELOW WALLS NORTH -NE/NW EAST SOUTH SE/SW WEST GRADE TOTAL y AREA 824 , 0 ; 525 : 873 : 0 ; 567 : 0 ; 2 ,789 COOLING ; 569 : 0 ; 363 : 603 , 0 ; 392 : 0 ; 1 ,927 HEATING ; 2 ,333 ; 0 ; 1 ,486 , 2 ,471 , 0 ; 1 ,605 ; 0 ; 7 ,896 , DOORS NORTH NE/NW EAST SOUTH SE/SW WEST TOTAL w-_______--_______________________w________-__________-_ AREA 21 : 0 ; 42 , 21 ; 0 ; 0 ; 84 COOLING ; 56 , 0 ; 112 , 56 , 0 ; 0 ;223 HEATING ; 228 , 0 ; 457 , 228 ; 0 ; 01,i 914 , FLOOR AREA COOLING HEATING 3020 268 ; 3 ,078 CEILING AREA COOLING HEATING 3020 857 ; 3 ,920 MISCELLANEOUS COOLING LOADS People Sensible Load 4 ,275 Latent Load 10 ,553 Lights & Appl . Load 8 ,021 Latent Safety Btuh 528 Ventilation Load 3 ,960 Duct Heat Gain 1 ,020 Infiltration Load 1 ,055 Sensible Safety Btuh 1 ,708 TOTAL SENSIBLE LOAD 36 ,885 TOTAL LATENT LOAD 11 ,081 Air Changes/Hour 0 .42 Temp . Swing Mult . 1 .00 Total Cooling Load 47 ,966 BTUH Or 4 .00 Tons = MISCELLANEOUS HEATING LOADS Infiltration Load 14 ,353 Ventilation Load 26 ,928 Duct Heat Loss 3 ,078 Safety Btuh 3 ,904 Load 85 052 BTUH ***Total Heating SUMMARY REPORT Prepared For : Prepared By: Clark Realty RP 658 Ellington Road R&E Heating & Cooling So Windsor Ct 06074 Job Name: 243-032 DESIGN CONDITIONS OUTDOOR INDOOR SUMMER WINTER SUMMER WINTER Dry Bulb 88 0 78 68 Wet Bulb 75 65 Daily Range 20 Daily Swing 3 .0 Latitude 41 Elevation 1100 Safety Factor ( 4 ) 5 Latent Factor ( % ) 30 Room Heating Heating Cooling Cooling Name BTUH CFM BTUH CFM Living Room 3 ,693 69 2 ,816 122 Family Room 4 ,245 80 2 ,829 123 Dining Room 2 ,615 49 2 ,237 97 Kitchen 11 ,317 213 3 ,138 136 Mud/L 'dr y 2 ,245 42 1 ,580 69 Bedroom 1 14 ,701 277 4 ,725 205 Bedroom 2 2 ,053 39 1 ,250 54 Bedroom 3 2 ,004 38 1 ,048 45 Bathroom 7 ,410 139 1 ,766 77 music/off ice 8 ,197 154 4 ,418 192 In-Law side 21 ,031 396 8 ,162 354 foyer 5 ,542 104 2 ,916 126 85 ,052 1 ,600 36 ,885 1 ,600 HEATING DELTA T 48 .3 COOLING DELTA T 21 .0 NOTE : *** Calculated Airflow is based upon load requirements . Verify that airflow calculated is compatible with selected equipment requirements . ***