Loading...
HomeMy WebLinkAbout189 Avery Street (2)4 DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby:TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit#644-2511 ext. 230 Date Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: C' 0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= 15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS L , nd:::-: APPLICANT PHONE# OW N S4. OWNER OWNER ADDRESS jpq UJ r a--5 0-ca 0 7 u i 0 OWNER PHONE ESTIMATED COST$ IS THIS A CONTRACT COST? Yes No CJ FEE ENCLOSED$ TYPE OF JOB:dS R,Cps 4New Installation Alteration/Addition/Repair Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: EATING RESIDENTIAL C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEAT G EQUIPMENT(INCLUDING MAX9&MODEL NO.) r,-) (')D j(),-f ,Q n GROSS HEATING CAPACITY(INPUT BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL QIL--GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) PESCRIAE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE -5 COOLING CAPACITY(BTUH) 5 600 VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) I FURTHER DESCRIPTION OF WORK 0! C C uC 6.t Orly n THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE DATESIGNATUREOFAPPLICANT D C H aPH 6/26/2003 laicL7V itioningItesadAM111AllAAIAAAANIaLIAALwir^w w..wr r woo In accordance with ACCA Manual J P.O.BOX 200,WINDSOR,CONNECTICUT06095 TELEPHONE(860)527-3744 Registered To: Aiello Plumbing Heating and Air Conditioning For: Jim & Kim Sharp 189 Avery St. South Windsor, Ct 06074 Design Conditions: Windsor Locks,Bradley Field Indoor: Outdoor: Summer temperature: 72 Summer temperature: 95 Winter temperature: 70 Winter temperature: 4 Relative humidity: 50 Summer grains of moisture: 93 Daily temperature rangeMedium Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss BTUH) BTUH) BTUH) BTUH) Whole House 1,173 sq.ft. 20,493 39315 23,808 50,121 2tons) First Floor 13,064 2,603 15,667 35,676 Bathroom 54 sq.ft. 1,232 108 1,340 2,642 porch 56 sq.ft. 1,458 403 1,861 5,228 Kitchen 100 sq.ft. 3,104 992 4,096 2,512 Dining Room 90 sq.ft. 1,937 280 2,217 5,418 Hall 30 sq.ft. 395 151 546 2,144 Family Room 392 sq.ft. 4,938 669 5,607 17,732 Second Floor 7,429 712 8,141 14,444 Bathroom 42 sq.ft. 773 58 831 1,431 Bedroom 120 sq.ft. 1,880 216 2,096 4,036 Hall 42 sq.ft. 967 86 1,053 1,712 master bed room 247 sq.ft. 3,809 352 4,161 7,265 Whole House 1,173 sq.ft. 209493 31315 23,808 509121 2tons) HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only,actual loads may vary due to weather and construction differences.