Loading...
HomeMy WebLinkAbout184 Griffin Road (2)DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: q (? oBUILDINGDEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 7 7 Da a Building Inspector Application must be printed or typed FEE SCHEDULE I -' c t5 T d A h;A( Location of Job: I g Q-)f iv.( Ind C v cy)r-CD50ru , ! 0-$1,000=$13.00 Street No. Street If Lot No. Over$1,000= 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT S• Tl S C L C G 7'2/G APPLICANT ADDRESS 4 APPLICANT PHONE# OL9" (i l D 00, W N s OWNER r1 yE S ;-/Z v r-! p L L G O fq OWNER ADDRESS r° OWNER PHONE 7 2 S' C ESTIMATED COST$ IS THIS A CONTRACT COST? , Yes G No FEE ENCLOSED$ 3 TYPE OF JOB: S0R.CO 13 New Installation IAlteration/Addition/Repair Revised 8/99 APPLICATION FOR ELECTRICAL PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? YES NO RESIDENTIAL BUSINESS CURRENT USE AND OCCUPANCY ASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCY EDUCATIONAL INSTITUTIONAL ENGINEER'S NAME PHONE FACTORY STORAGE ADDRESS GARAGE MIXED USE CITY STATE ZIP Other please specify) TYPE OF INSTALLATION/WIRING METHOD SIZE OF SERVICE SIZE OF MAIN CONDUCTORS NUMBER OF METERS NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED? YES -XNO NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS / NUMBER OF SWITCHES NUMBER OF OUTLETS 30 NUMBER OF LIGHT FIXTURES Z D NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPARATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK e iTL6 7-5 Al-1 c7 j Ci12.Gu/T;' Gd7P M D THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. Z 3 5 CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE 6 '7 d 6 7 DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: Q BUILDING DEPARTMENT APPROVED 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Dat Building Inspector Application must be printed or typed Location of Job: FEE SCHEDULE C '0 0-$1,000=$13.00 Street No. Street Lot No. Over$1,000=r 4,— ,T—L7,,W 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT 1/ APPLICANT ADDRESS r APPLICANT PHONE#TL N S OWNERWq OWNER ADDRESS V 7 M OWNER PHONE C ESTIMATED COST$ IS THIS A CONTRACT COST? 1'es 0 No FEE ENCLOSED$ 13. C-1 TYPE OF JOB: SOR*CO New Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION? YES NO RESIDENTIAL BUSINESS CURRENT USE AND OCCUPANCY ASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCY EDUCATIONAL INSTITUTIONAL ENGINEER'S NAME PHONE FACTORY STORAGE ADDRESS GARAGE MIXED USE CITY STATE ZIP Other please specify) TYPE OF INSTALLATION N Zry SIZE OF MAIN DRAIN NO.OF TOILETS STYLE VAA NO.URINALS — STYLE NO.OF BATHTUBS NO.OF SHOWERS NO.OF LAVATORIES c NO.OF CONDUCTORS SIZE NO.OF STACKS SIZE 3 AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW YES NO SIZE OF WINDOW IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR EPTIC)ANK 3 t T l SIZE OF WATER MAIN 3 SIZE OF WATER PIPING&RISER WATER HEATER: TYPE l=—- `MANUFACTURER qQ,•O . r T H-- DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. T>) - 2cl c COATRACTORS ICEN E NO. E STATE SIGNATURE OF APPLIC T DATE 4 -2,0 ,— r DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: Oc2/BUILDING DEPARTMENT 1540 SULLIVAN AVENUE Bldg.Permit# tfl 0f 644-2511 ext. 230 7lcl 1 ate Building Inspector Application must be printed or typed Location of Job: FEE SCHEDULE y(,, 6-r 0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT APPLICANT ADDRESS 7-y i D o `7 c C!/i -co r- C l APPLICANT PHONE# OWNER Gr L.L. C_ O e V t_ 1< OWNER ADDRESS x. O * OWNER PHONE C ESTIMATED COST$ IS THISTHIS A CONTRACT COST? 0-Yes 0 No FEE ENCLOSED$ 7 p r ' SpR.CO TYPE OF JOB: New Installation 13 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: 1"EATING 4 RESIDENTIAL A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC 4 WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE® OF INSIDEf o OF DIFFERENCE o OF TOTAL HEAT LOSS(BTUH)-2LA7 V OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCL•UDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) a 6`v NET RATING(OUTPUT—BTUH) TYPE OF FUEL OIL—GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY aGAS—INPUT 9G<o LPG TANK CAPACITY B/ orl e5 ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK A.-r tp VC C •-t. • T. THE UNDERSIGNED HEREBY APPLfES PdR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO TYP STATE SIGNATURE OF APPLICANT DATE 1 0 l ADVANCE HEATING JOB NAME: NAME TOWN DESIGN CONDITIONS TOTAL BLDG. HEAT LOSS/GAIN PHONE STREET CT. BLDG : Griffin Rd. Heating: 80 deg f.t/d BLDG Heat Loss BTU 20,278 Estimator: NOTES: Cabin Cooling: 20 deg f.t/d BLDG A/C Gain BTU 22,314 Stephen Smith Room 1 Room 2 Room 3 Room 4 Room 5 Room 6 Room 7 Room 8 Room 9 Room 10 Room 11 Room 12 AREA NAME; Great Lav Kitchen Outside Wall Length; 86.0 12.0 12.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Outside Wall Height; 10.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 Sq/Ft S or W Glass ; 62.0 0.0 12.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Sq/Ft N or E Glass ; 48.0 12.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 No of Doors 0.0 1.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Floor Width 28.0 8.0 22.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Floor Length 30.0 12.0 12.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Roof Width 28.0 8.0 22.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Roof Length 30.0 12.0 12.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Area Cubic Feet 8,400 768 2,112 0 0 0 0 0 0 0 0 0 Gross Wall sq/ft 860 96 96 0 0 0 0 0 0 0 0 0 Net Wall sq/ft 750 63 84 0 0 0 0 0 0 0 0 0 Wall Heating BTU 2,400 202 269 0 0 0 0 0 0 0 0 0 Wall Cooling BTU 1,200 101 134 0 0 0 0 0 0 0 0 0 S/W Glass sq/ft 62 0 12 0 0 0 0 0 0 0 0 0 S/W Glass Heating BTU 3,075 0 595 0 0 0 0 0 0 0 0 0 S/W Glass Cooling BTU 769 0 149 0 0 0 0 0 0 0 0 0 S/W Glass Solar BTU 4,960 0 960 0 0 0, 0 0 0 0 0 0 N/E Glass sq/ft 48 12 0 0 0 0 0 0 0 0 0 0 N/E Glass Heating BTU 2,381 595 0 0 0 0 0 0 0 0 0 0 N/E Glass Cooling BTU 595 149 0 0 0 0 0 0 0 0 0 0 N/E Glass Solar BTU 1,920 480 0 0 0 0 0 0 0 0 0 0 Doors sq/ft 0 21 0 0 0 0 0 0 0 0 0 0 Door Heating BTU 0 538 0 0 0 0 0 0 0 0 0 0 Door Cooling BTU 0 168 0 0 0 0 0 0 0 0 0 0 Floor sq/ft 840 96 264 0 0 0 0 0 0 0 0 0 Floor Heating BTU 1,882 215 591 0 0 0 0 0 0 0 0 0 Floor Cooling BTU 2 0 1 0 0 0 0 0 0 0 0 0 Roof sq/ft 840 96 264 0 0 0 0 0 0 0 0 0 Roof Heating BTU 2,016 230 634 0 0 0 0 0 0 0 0 0 Roof Cooling BTU 840 96 264 0 0 0 0 0 0 0 0 0 Lights Cooling BTU 717 82 225 0 0 0 0 0 0 0 0 0 Appliance Cooling BTU 1,176 134 370 0 0 0 0 0 0 0 0 0 People Cooling BTU 630 72 198 0 0 0 0 0 0 0 0 0 Latent Cooling BTU 560 64 176 0 0 0 0 0 0 0 0 0 Ventilation Heat BTU 2,116 320 376 0 0 0 0 0 0 0 0 0 Ventilation Cool BTU 2,406 242 446 0 0 0 0 0 0 0 0 0 Duct Heat Loss BTU 1,387 210 246 0 0 0 0 0 0 0 0 0 Duct Cool Loss BTU 1,577 159 292 0 0 0 0 0 0 0 0 0 Area Heating BTU 15,256 2,310 2,711 0 0 0 0 0 0 0 0 0 Area Cooling BTU 17,352 1,747 3,215 0 0 0 0 0 0 0 0 0 Area Air Heating CFM 201 30 36 0 0 0 0 0 0 0 0 0 Area Air Cooling CFM 578 58 107 0 0 0 0 0 0 0 0 0 TTL Building. Square feet-> 1,200 Heating Air Changes/Hour -> 1.42 TTL Building. Cubic feet-> 11,280 Cooling Air Changes/Hour -> 3.96 TTL Building Heating CFM -> 267 Heating CFM per SQ/FT ->0.22 TTL Building Cooling CFM -> 744 Cooling CFM per SQ/FT ->0.62