Loading...
HomeMy WebLinkAbout180 Morgan Farms DriveTO THE BUILDING INSPECTOR of the APPLICATION FOR TOWN OF SOUTH WINDSOR, CONN. PL N EXAMINATION I A N D UILDING PERMIT IMPORTANT — Applicant to complete all items in sections: 1, 11, 111, and IV. p 1 ZONINGAT (LOCATION) DISTRICT LOCATION NO.) J STREET) 310)-fIOFBETWEENSO//, k6aq (,1(2- AND BUILDING CROSS S—TWtET) CROSS STREET) LOTSUBDIVISIONLOTBLOCKSIIZEgyp? .CJ1Q 11. TYPE AND COST OF BUILDING - A11 applicants complete Parts A — D A. TYPE OF IMPROVEMENT D. PROPOSED USE — For"Wrecking" most recent use 1 New building Residenti Nonresidentia 2 Addition(/residential, enter number 12 One family 18 Amuse nt, recreationalOfnewhousingunitsadded, if any, in Part D, 13)13 Two or more family — Enter 19 Church, other religious number of units— — — — --3 Alteration (See 2 above) 20 Industrial Transient hotel, motel,21 Parking garage4ElRepair, replacement or dormitory — Enter number 5 Wrecking (/multifamily residential, of units ——————— — i 22 Service station, repair garage enter number of units in building in 15 Garage 23 Hospito, institutional Past D, 13) 6 M ving (relocation)16 Carport 24 Office, ank, professional 17 Other — Specify 25 Public tility7 Foundati n only 26 School, ibrary, other ducational B. OWNERSHIP 27 Stores, i iorcanti Is 8 Private(individual, corporation, 28 Tanks, owers nonprofit institution, etc.) 29 Other — Specify 9 Public(Federal, State, or local government) C.COST Omit cents) WORK DESCRIP ION: 10. Cost of improvement. . . . . . . . . . . . . . . $dose IrA I ry-1 a. El ctrical . . . . . . . . . . . . . . . . . . . . . b. Plumbing . . . . . . . . . . . . . . . . . . . . . c. HVAC . . . . . . . . . . . . . . . . . . . . . . Cl. Sprinkler . . . . . . . . . . . . . . . . . . . . . e. Garages. . . . . . . . . . . . . . . . . . . . . . f. Other 11. TOTAL Fee: CO Fee: Total: ?ZY 111. SELECTED CHARACTERISTICS OF BU DING — For new buildings and additions, complete Part E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPLE TYPE OF CONSTRUCTION G. TYPE OF SEWAGE DISPOSAL J. DIMENSIONS 40 Public or private company 48. Number of stories..... .....%.... 30 Type 1: E::]A B 41 Private (septic tank, etc.) 49• Total square feet of floorarea all floors, based on ext rior 31 Typ 2: A B C dimensions ..................... 32 Typ 3: A B H. TYPEN WATER SUPPLY 42 Public or private company 50. Total land area, sq. ft. ........... A33 pe4 43 Private(well, cistern) K. NUMBER OF OFF-STREET 34 Typ 5: A 2 B PARKING SPACES F. PRINCIPAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL 51. Enclosed ....................... 35,ErGas Will there be central air 52. Outdoors........................ 36 Oil conditioning? L. RESIDENTIAL BUILDINGS ONLY 37 Electricity 44 Yes 45 Yl n 53. Number of b dr oms... ........ 39 Cal 39 Oth r— Specify Will there be an elevat r? 54. Number f Full.......... 46 0 Yes 47 N bathr ms Partial........ IV. IDENTIFICATION — To be completed by all applicants Name Mailing address — Number, street, city, and State ZIP code Tel. No. Owner or Lessee c ry 2. v Contractor 3. t IArchitector o j vn Engineer NJ i The owner of this building and t-he undersigned agree to conform to all applicable laws of this jurisdiction. Signatur f applicant Address Application date I 4:L4Irn 00 NOT WRITE BELOW THIS LINE V. PLAN REVIEW RECORD — For office use Plans Review Required Check Plan Review Date Plans By Date Plans By Notes Fee Started Approved BUILDING PLUMBING MECHANICAL ELECTRICAL OTHER V1. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Date Date Permit or Approval Check Obtained Number By Permit or Approval Check Obtained Number By BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER VII. VALIDATION Building Permit number Building ZPermitissued 19 Building 7PermitFee $ Approved by: JQ- 7-1Z -,EF TITLE r3 9 FARMS DR. Rs x_ Kv"Ctl -TWC. Permit # i 0 9l Electrician -3pwE-5 & VWWAI-E@xj # /D b S Heating Contr. Plumbing 11 k-,4 ,,eG y 0 cAlTE Z js,5 Oil Burner Certificate of Occupancy Sewer Permit 8k 7WA.. i o. by 1-P.7 jt1..L,,/C 7 INSPECTION REPORT Permit LbT .39 -,#/ AN 140VK 1 Footing -- 6 i S ` i 1- /(C• 2 Foundatio T- 3 Framing 4 Wiring cl Dlo 5 Plumbing y 6 Heating 7 -le#+%g v r-2.S. a C.o. _ I o9J Y F^ h i} BUILDING INSPECTION DEPARTMENT SOUTH WINDSOR, CONNECTICUT FEE PAID: $3.00 CERTIFICATE OF OCCUPANCY ZONE: A—2 0 DATED October 24 19 89 This is to certify that Erected under permit No. 17091 conforms substantially to the requirements of the buil ing ordinances and the zoning regulations of the Town of South Windsor and is hereby approved for occupancy as indicated below. Approved for Occupancy— Single family residence Building Official Notice:If this certificate is lost or destroyed, a duplicate shoukrbbtained immediately from the Building Department. Any change or extension of the use herein approved requires a new certificate of occupancy. CERTIFICATE OF OCCUPANCY CHECK LIST Applicant RSK Kellco Certificate of Occupancy c Address Bldg. Permit No. /70 9 Lot No. 39 , 180 Morgan Farms Dr Date Submitted -75-19-89 Project MORGAN FARP-IS Reviewed By Date As required in the Zoning Regulations, no certificate-of=o cupancy shall be issued until grading-plans_have been complied wit and approved by the Town Engineer. The minimum requirement shall include: Approved Denied N/A 1. Approved building permit plan. 2. Finish grading per approv d building permit plan. 3. Site work; i.e. trees, shrubs, dumpsters, required parking 4. Utility location a. sanitary sewer T b. foundation drain c. electrical & telephone d. water e. other 5. Appropriate certification 6. Bonding Sewer Permit No. Pavement Excay. No. COMMENTS: uZ — M O a 0 a _ S69* E H }' c o> W20 o t61. 4 10' SY. z zNcoo 3 M In r NM00 j0 // O// i 1; o 04ook, c M Avl) d o . CIA 1 O. 1i to ti j A a IA? o x Q W- O Q O a J c 6 Q u- mow V Cn Af'. o' 0. 0• W J 4 90 0 2' 2 8" W z — cr Z O W N O W W W Yo W m 6c N o Z LOT - 40 N J t 0 m I N Q CM O 0- 0 W W m YW ate = N M 0- o v; NOTES: Q z W Z x CJ x o J0oz 1) UTILITY LOCATIONS PROVIWAC CONTRACTOR. O _ V! = Q Z O J Y LOT SUMMARY L =' cr. z W a 2) SITE GRADING PROVIDED if- C TRACTOR - H W GARAGE FLOOR ELEV. - 122. 57 Q a a W i 3) CONTRACTOR' S NOTE: MEC# 4NICAL_ FOOTING DRAINS FINISHED FLOOR ELEV. - 124. 52 L Z } z O INSTALLED SUITABLE FOB:- jNSTALLATtON OF SUMP dS 0 F. W PUMP IF FUTURE CONDITIOJ,- FARRANT. z o W ow tv f, 014( 3JQ;/ O LL m t W ( A NfRfSY OfCLARf tNAt t/' i/ S AI AP 7sR.., j/ Ani3tANr/ ALLP CORRECT, tNts, xAP A, i GNoll. F- z U AND Sb. RVEY Wflft PRfPAREO / N ACCORAANCf M' 1tN tNE STAN0A/ f0 OF A 4rq 9 v W Z V C AS Off/ A' E0 / N tNf" RfCONMf& oE0 trA* CAROS r0R CO% z% cOc Z W N N a C L ASSA Z BUR F Q ,, G W y 0 y SbRVE I D MAPJ iX rlVf stAtf OF CONNfCt/ CUt AS PRfI' ARfO AND JJ Ir Z N Q a ADOPTED or tNf CONNECt/ CUt ASSOC/ AtiON OF LAND SlflfVFrORsj, INC., No. 14649 ,. 0 Ind Q W 0) ON St 1# 14 AND EFFECt/ VE Aif& AR1' 1, 1tI1, SRO' U M W m m svRVfr0R S/ i6NATflRf OAT£ L/ CNS£ Nf/ MI£ R i Z 3 ~ O Q j 0 sUa iirirrrt J uJ II 1989 South Windsor BUILDING DEPARTMIENT TH WINDSOR e true to be dnc inn clerk C 1 lOCT" v 1// A P rO WN OFENG SO.rN D Dq SNEERING pEPgR.?.,NDSORt'E: MENT G.s BUILDING PERMIT CHECK LIST Applicant RSK Kellco Building Permit No. 7 0 Address_j Morgan arms rive Date Submitted 7- -gg Lot No. RevisedReviewed by Project Morgan Farms Date la In accordance with the Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include : Approved Denied N/A 1. Name, address & phone number of owner/ applicant. 2. Name, address & phone number of plan preparer. 3. Zoning information - i.e. zone, open space, fl oodway, etc. v 4 . Plot plan at 1" = 40' scale. a. Subdivision reference, abutting properties , etc. b. Easements of record. c. Lot description, bearings, distances, 7- building lines, area, etc. d. Contours, existing & prop sed, 1 or 2 f t. interval where appropriat . e. Building location with dimensions. Elevations of proposed finish floor, garage floor & center line, of road at driveway. y f. Elevations of gravity drainage systems, sanitary & foundation drain at the house and the street. e/ g. Tentative utility location gas, electric, water, etc. h. Title block with name and address of preparer, date appropriate certification, live seal and signature. 5. Sedimentation and erosion control. 6. Special Planning & Zoning, Inland/Wetlands considerations. (Plans on file w Town Clerk) BUILDING DEPT. PZC IWA/CC WPCA OTHERS COMMENTS: BUILDING PERMIT CHECK LIST Applicant RSK Kellco Building Permit No. 70 y Address Morgan Farms Drive Date Submitted 7-8 gg Lot No. 39 Reviewed by Project Morgan Farms Date In accordance with the Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include : Approved Denied N/A y 1. Name, address & phone number of owner/ applicant. number of an preparer.2. Name, address & phone p p p 3. Zoning information - i.e, zone, open space, fl oodway, etc. 4 . Plot plan at 1" = 40' scalp. a. Subdivision reference, abutting properties, etc. t b. Easements of record. c. Lot description, bearings, distances, building lines, area, etc. d. Contours, existing & prop sed, 1 or 2 ft. interval where appropriate . e. Building location with di ensions. Elevations of proposed finish floor, garage floor & center line of road at driveway. f. Elevations of gravity drainage systems, sanitary & foundation drain at the house and the street. g. Tentative utility locatior gas, electric, water, etc. h. Title block with name and address of preparer, date appropriate certification, live seal and signature. 5. Sedimentation and erosion contro . 6. Special Planning & Zoning, Inland/Wetlands considerations. (Plans on file w Town Clerk) BUILDING DEPT. PZC IWA/CC v WPCA OTHERS COMMENTS: PERMIT # DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT b Application is hereby: TOWN OF SOUTH WINDSORAPPROVEDBUILDINGINSPECTIONDEPT. 644 -2311 Ext. 230 Date Bui ding Inspe Applications must be printed or tvppd- 1. LOCATION OF JOB FEE SCHEDULE No. Street Floor Apt. No. S 0 - $19000 - 10.00 Over $1,000 - 10.00 2. OWNER a 67 C per $1,000 or 3. ADDRESS U!fraction thereof QAft op 43 I 4. APPLICANT_ Y ,,se 5. ADDRESS`_-- Z- ACTUAL COST $ FEE $ 6. ESTIMATED COST S Q d ESTIMATED COST $_ FEE $ 7. IS THIS A CONTPLACT COST? Of YES CI NO FILE COMP. BY BALANCE $ 8. FEE ENCLOSED $ r -769/ 9. TYPE OF BUILDING: M Rr.SIDENTTA , Q COv.%1ERCIAL 1.0. IYPE OF JOB: ORIG IXAT, ALTEP,A'f I0.%4 IVSTALLATTO)ti Q ADDITION REPAIR APPLICATION FOR ELECTRlCA4 Pf,.fQA T(Continued trom itevarse Side) 11. LOCATION OF JOB NO. STREET FLOOR APT. N0. 12. TYPE OF INSTALLATION Xe l) &(;J'!. 13. SIZE OF MAIN FEEDER _ /7t 3 14. NO. OF LIGHT LOOPS 15. NO. OF HEAT LOOPS 16. NO. OF PGigER LOOPS 17. NO. OF LIGHT OUTLETS_ _ 18. NO. OF HEAT CIRCUITS 19. NO. OF POWER 20. NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS_ 22. NO. OF POWER CIRCUITS_ 23. NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS 25. NO. OF MOTORS 26. NO. OF PANELS 27. TOTAL WATTAGE 28. NO. OF POWZR PAM?lS 29. NO. OF SWITCHES 30. A/C LOAD 31. SIZE OF POWER FEEDERS_ 32. NO. OF FIXTURES 33. TOTAL HORSEPOWER 34. NAMES OF SUBCONTRACTORS AND THEIR TRADES 35. REMARKS AND FURTHER DETAILS: LICENSE;NO. ATURE OF APPLICANT PHONE NUMBER: PERMIT No DEPARTMENT DECISION APPLICATION IS HEREBY: A P P L I C A T I O N F O R PROVED DISAPPROVED PLUMBING PERMIT TOWN OF SOUTH WINDSOR 9tq-- A01 BUILDING INSPECTION DEPT. DATE PL701 INSPECTOR 644 -2511 Ext. 230 IApplication must be printed or typed. 1. LOCATION OF JOB: FEE SCHEDULE OWNER: 0 - $1,000 - $10.00 3. ADDRESS: C Over S1,000 - $10.00 S per $1,000 or n r+Fraction Thereof 4. APPLICANT: coo,4y 5. ADDRESS: 6. EST. COST: 7. IS THIS A CONTRACT COST? veY ES NO pA K8. FEE ENCLOSED: $ 9. TYPE OF -BUILDING: a--'IESIDENTIAL COrDIERCIAL 10. TYPE OF JOB: ORIGINAL ALTERATION INSTALLATION ADDITION REPAIR APPLI,Ai iuN rUct uunc. t LL)W A.U. 11. LOCATION OF JOB: Z-cd-'n GENERAL PLUMBING 12. KIND OF INSTALLATION: 13. SIZE OF MAIN DRAIN 14. N0. OF TOILETS kSTYLE 15. NO. OF URINALS f STYLE 16. NO OF BATHTUBS L 17. NO. OF LAVATORIES 3 18. NO. OF SINKS_/ 19. DISPOSAL_ 16A. NO. OF SHOWERS__ 19A.DISHWASHER 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS SIZE 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS-- 25. NO.OF OTHER FIXTURES KIND 26. ARE TOILET COMPAFUMENTS VENTILATED TO OUTER AIR Y A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? b ^ 29. SIZE OF DUCTS J 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN J 31A. SIZES OF WATER PIPING & RISERS f T 32. REMARKS AND FURTHER DETAILS WATER HEATER 33. TYPE Qwo 34. MANUFACTIRRR lqo TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY gal 39. RELIEF VALVE 9[6( 36. TEST PRESSURE LBS. 40. MANUFACTURER cj p-e,- 37. WORKING PRESSURE l S`LBS. 41. PRESSURE RELIEF VALVE D(L G 38. TYPE Cj-a 42. MANUFACTURER4 ct- LI ENSE 0. DATE SIGNfURE OF APPLICANT PHONE NO. USE ONLY APPLICATION FOR HVAC PERMIT DATE gE NO. - TOWN OF SOUTH WINDSOR EST.COST: BLDG. PIWIT NO* G?9 1540 SULLIVAN AVENUE FEE SOUTH WINDSOR, CT 06074 FEES 644-2511 - Ext. 230 0 - $19000 - $10.00 10 0 or fraction LOCATION OF BUILDING thereof - $10.00t OWNER ADDRESS TOWN PHONE NO. jol,gad" Coat, x J?\M rma C HVAC CONSUCTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING 41 TYPE OF BUILDING: RESIDENTIAL A/C COMMERCIA VENTILATION BUSINESS INDUSTRIA IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC_,e WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE-_0°F INSIDE_';°F DIFFERENCE-4M OF TOTAL HEAT LOSS (BTUH)_j!j"6 HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.) : Own C4%kLLdWvLA110 G GROSS HEATING CA ACITY (INPUT-BTUH) 10000 NET RA NG (OUTPUT-BTUH)Q IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE OF INSIDE F DIFFERENCE OF TOTAL HEAT GAIN (BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.) : TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN E HAUSE EQUIPMENT) : TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: I'Mik #3 or/6-7P &m4te S-7 07 STATE LICENSE - AME & TYPE #DATE GNv RE UCAAICANT APPROVED DATE 8D 4A 11/88 I = B= R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The Hydronics Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL.A COL.B COL.C COL.D COL.E COL.F COL.G 11 ROOM Q O H L W H L W H L W H L W H L W Design Water Temp. 2 ROOM DIMENSIONS, FT O BTUH per Foot f 3 LENGTH EXPOSED WALLS, FT. Q Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION Table 9, Line 3 x H) ROOM LIN.FT.OF TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED Bottom of table used for Line 5) 7 CEILING CONSTRUCTION C Table 9, L x W) B FLOOR CONSTRUCTIONt D Table 9, L x W or Lin Ft) E 9 COLD PARTITION CONSTRUCTION F Table 9, L x H)G 10 c 1 Wall(With Openings)C H c 2 Walls(With Openings) e X 1 3 Walls(With Openings) or Ent Hall 11 TOTAL NTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K COL A COL.B COL.H COL. 1 COL J COL. K COL.L TOTAL BTUH TOTAL OF BUILDING RADIATION1ROOMATSELECTED O H L W H L W H L W H L W H L W DESIGN TEMP.° 2 ROOM DIMENSIONS, FT DIFFERENCE 3 LENGTH EXPOSED WALLS, FT Q 4 WINDOW AND OUTSIDE DOOR AREA J LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9, Line 3 x H)TOTAL 20% 6 TYPE OF GLASS ---- Bottom of table used for Line 5) 7 CEILING CONSTRUCTION tFOR CONCRETE FLOOR ON I GROUND OR FILL AT Table 9. L x W)GRADE LEVEL,USE LINEAR B FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE Table 9, L x W r Lin Ft) 9 COLD PARTITION CONSTRUCTION Table 9, L x H) 10 C 1 Wall(With Openings) G 0 e; e 2 Walls(With Openings) X J 3 Wells(With Openings) or Ent Hall 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE This form is available from The Hydronlcs Institute,35 Russo Place,Berkeley Heights,N J 07922 FORM 1503 I = B= R CALCULATION SHEET 1503 (Modern Method)Copyright 1977 by The HydronlCs Institute OWNER AO RESS aCSIGN TEMPERATURE DIFFERENCE MF. DATE COL.A C L.8 COL.C COL O COL.E COL.F COL_G 1 ROOM K D C L.-1 111 Y L 00 O H L W H W H W H L W N L W Deslsn Water Temp. 2 ROOM DIMENSIONS, FT.131 BTUH per Foot o1zeLENGTHEXPOSEDWALLS, FT, t G Radiation Selected v 41 WINDOW AND OUTSIDE DOOR AREA 5 WALL CONSTRUCTION I O ROOM LIN. FT.OFTable9,Line 3 x H) 07 U v TOTALS RADIATION6) TYPE OF GLASS FROM LINE 12 SELECTED bottom f table used for Line 5) 71 CEILING CONSTRUCTION I C OV Table 9,L x W)r ca 8 FLOOR CONSTRUCTIONt O L O0 I Table 9,L x W r Lin. Ft.) E 91 COLD PARTITION CONSTRUCTION F l Table 9,L x H) G `10 C 1 Wall(With Openings) 0 32WellstWithOpenings)X 7 V J V 1 I 7ia V3Walls(With Openings) or Ent Mall d J y d11ITOTALSTUNAT70FTEMP. DIFFERENCE' O I J bT ODy5 K /6O T1T<2 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE QV 0 V O lJ L //0 0 COL_A COI..a COL H COL_1 COL.J COL.K COL.L TOTAL BTUH TOTALiROOM tL D OF BULL ING AT SELECTEDIOHWHL-17 W H I L W H L W H I L W DESIGN TEMP.* 2 ROOM DIMENSIONS,FT. I' C DIFFERENCE V LENGTH EXPOSED WALLS, FT. t 4- G 4 WINDOW AND OUTSIDE DOOR AREA 12/ STUN STUN BTUH STUN STUN5WALLCONSTRUCTION Table 9,Line 3 x H) INCREASE BATHROOM V j( ) DD TOTAL 20% 6 TYPE OF GLASS vvvvvv B ttom of table used for Line 51 3 -OD O 7 D O7CEILINGCONSTRUCTION j' J i LL3 D tG CONCRETE FLOOR ON Tab1 9.L x WIGROUND RGRAOEO OR LEEL!USE LINEAR LL AT S FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGETable9,L x W or Lin.FL) 9 COLD PARTITION CONSTRUCTION Tattle 9,L x H) 1 Ec_'-0 1 w.lr(win,op.•+ingal A(Z p d 0 02Walls(with Openings) X Old Q Walls(With Openin e Jes1orEntHell 11 TOTAL STUN AT 70F TEMP. DIFFERENCE 0 y 12 TOTAL STUN AT DESIGN TEMP. DIFFERENCE a y6-OO c O lJ O i Phis f rm Is available from The Hydronics Institute,35 Runo Piece,Berkeley Heights,N.J.07922 Cam./ FORM 1503 1 B= R CALCULATION SHEET 1503 (Modern Method) 11 Copyright 1977 by Th Hydr n(cs Institute OWNER Yi ADDRESS T O'Jti ^DESIGN TEMPERATURE OIFFERENCE.f. DATE COL A COL.d COL_C COL.D COL.E COL.F COL.G 1 ROOM Ir O H L I W H L W H L W H L W H L W Design Water T mp. l 2 ROOM DIMENSIONS, FT. V STUN per Foot of 3 LENGTH EXPOSED WALLS, FT. Radiation Selected 6 d 41 WINDOW AND OUTSIDE DOOR AREA STUN 19TUM BTUH STUN STUN 71 WALL CONSTRUCTION I ROOM LIN. FT,OFTable9,Line 3 x H)7, TOTALS RADIATION 6 TYPE OF GLASS O FROM LINE 12 SELECTEDI (Bottom f table used for Line 5) 7 CEILING CONSTRUCTION CI (Table 9.Lx W) rQ I DO 8 FLOOR CONSTRUCTIONt D 6 Table 9,L x W r Lin. FL) E 9 COLD PARTITION CONSTRUCTION F Table 9,L x H) 10 _c 1 Wall(With Openings) C 01 c N 2 Walls IWith Op nings)x 3 Wells(With Openings) or Ent Hall J 1 J11TOTALBTUHAT70FTEMP. DIFFERENCE' y30 0 F t7/Z/0 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE OCR I LS-0 0 C> T- K L COL.A COL.B COL.H COL.1 COL.J COL. K COL.L TOTAL STUN TOTAL 1 ROOM OF BUILDING RADIATION I Q AT SELECTED O H L W H L W H L W H L W H L W DESIGN TEMP.* E' 2 ROOM DIMENSIONS,FT.DIFFERENCE 3 LENGTH EXPOSED WALLS, FT. 4 WINDOW AND OUTSIDE DOOR AREA U. STUN STUN STUN STUN STUN 5 WALL CONSTRUCTION O` INCREASE BATHROOM Table 9,Line 3 x H)I TOTAL 20% 6 TYPE OF GLASS Bottom of table used for Line 5) 7 CEILING CONSTRUCTION tFOR CONCRETE FLOOR ON GROUND OR FILL ATTable9,L xW) 0 GRADE LEVEL.USE LINEAR B FLOOR CONSTRUCTION' FEET OF EXPOSED EDGE Table 9,L x W r Lin. Ft_) 9 COLD PARTITION CONSTRUCTION Table 9,L x H) 10 'Wall(With Openings)c r (Zo 2 Walls(With Openings)eaX Olcc 3 Walls(With Openings) r Ent.Hall 11 TOTAL STUN AT 7OF TEMP. DIFFERENCE• 12 TOTAL STUN AT DESIGN TEMP. DIFFERENCE this form Is evellabl from The Hydronics Institute,35 Russo Place,Berkeley Heights,N.J.07922 FORM 1503 c ' Y u 4 Cj 1540 SULLIVAN AVENUE SOUTH WINDSOR, CONN. 06074 aSOR•c r AREA CODE 203/644-2511 July 12 , 1988 Mr. Richard S. Kelley RSK-KELLCO, INC. 1744 Ellington Road South Windsor, Connecticut 06074 Re : 180 & 189 Morgan Farms Dr. Footing Drains Dear Mr. Kelley: Please be advised that building permits for the aboie mentioned address will be issued with the condition that sump pumps be pro - vided and put into full working condition prior to the issuance of a certificate of occupancy. Yours t uly, John R. Collins Chief Building Official JRC/chm