Loading...
HomeMy WebLinkAbout18 French LaneSectric# 70 APPLICATION FOR BUILDING PERMIT Plumbing# 0 18 French Lane WAC # C ` (0((27361 at Sprinkler# NO• fmi 1 ma sf Building?/ ( COMPLETE RED BOXED AREAS Permit Fee O cs oEngineerTYPEORPRINTONLYOccupancyFeeEgtOAffidavitSIGNONREVERSESIDEAppr.for CO.Total Fee TO BIALDM DEPARTMENT,TOWN OF SOUTH WNDSOR,CT Additional Cost) $ The undersigned hereby applies to do work according to the following specifications: Job location Lot No. Side of Street_Zone - " Applicant Tel# 4 2 19 2,93 Addr ss 4 Zip Lic# Own r Address Architect Address Sq.Ft.N w Area: 1st FI. 2nd FL 3rd FL Total New Area Rooms 2L lavatories Bathrooms Garages Purpose of this permit: City Water W-II Septic Syst m Sew Ins. H.O. S.P. Cert. Area 1& Basement Approved by Date Use Group Q A Revaed 1/97 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this building and its use is allowed Slgne I hereby apply for a Certificate of Occupancy for the work described in this application for the permit. Signe DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Location of Job:AFFIDAVIT Additional Fee$ 481 . 00 State of Connecticut ss.South Windsor County of Hartford Owner of 1 ,/ C 1 gT b, ,rr Agent for the building erected 2 7 3 61 Contractor under Permit No. issued by the Building Department of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed work autho ' ed under sai permit did not exceed the most current accepted BOCA value of$ 171 , 9 3 8 . 0 0 Sign Subscribed and sworn to before me this day of A.D.20&T Estimated Cost S 135j600 . Difference: $ 36 , 338 . Notary Public Inspection / Approval Date By Appl Code Description Due Whom Code Comment 27361-B 120,000 BO1 FOOTING 10/27/00 CJD A W/NADEAU B02 FOUNDATION 11/03/00 CJD A WATERPRF. AND FTG.DRAINS P02 UNDERGROUND 11/29/00 JFF A WITH CONTRACTOR E01 SERVICE 12/07/00 CJD A B05 FIREPLACE/CHIMNEY 12/12/00 JFF A WITH CONTRACTOR B03 FRAMING (ROUGH) 02/13/01 CJD A W/ROGER RECVD. SPECS OK P03 ROUGH 02/13/01 CJD A W/TIM DWV AND H2O E03 ROUGH 03/15/01 CJD A W/CURRENT THING B04 INSULATION 04/02/01 CJD A W/ROGER PO4 GAS TEST 05/11/01 CJD A LEFT TICKET E03 ROUGH 05/17/01 CJD D MOVE WIRE BACK TO 5/4 FROM FACE OF FRMG. Q CEILING LICHT B10 FINAL 07/18/01 JFF A WITH ROGER B10 FINAL 07/18/01 JFF A CLOSED OUT 10767-P 3,000 11041-H 3,000 11015-H 5,700 17058-E 3,900 co 0 z z Inspection / Approval Date By Appl Code Description Due Whom Code Comment 27361-B 120,000 BO1 FOOTING 10/27/00 CJD A W/NADEAU B02 FOUNDATION 11/03/00 CJD A WATERPRF. AND FTG.DRAINS P02 UNDERGROUND 11/29/00 JFF A WITH CONTRACTOR E01 SERVICE 12/07/00 CJD A B05 FIREPLACE/CHIMNEY 12/12/00 JFF A WITH CONTRACTOR B03 FRAMING (ROUGH) 02/13/01 CJD A W/ROGER RECVD. SPECS OK P03 ROUGH 02/13/01 CJD A W/TIM DWV AND H2O E03 ROUGH 03/15/01 CJD A W/CURRENT THING B04 INSULATION 04/02/01 CJD A W/ROGER PO4 GAS TEST 05/11/01 CJD A LEFT TICKET E03 ROUGH 05/17/01 CJD D MOVE WIRE BACK TO 5/4 FROM FACE OF FRMG. CEILING LICHT 10767-P 3,000 11041-H 3,000 11015-H 5,700 17058-E 3,900 Total Est Value 135,600 Dwelling 2,916 140,784.48 Basement 1,437 20,405.40 Garage 720 10,224.00 Smoke Det 7 525.00 r BOCA Value 171,938.88 Difference 36,338.88 1 ` 0 i 7P M SITE COMPLIANCE CHECKLIST 110,1149 114 TOWN of SOUTH WINDSOR, CONNECTICUT V 18 FRENCH LANE LOT_##43 Reviewed By 17 En ineering)CLARK REALTY, INC. Date Reviewed /6 pprove /Denied 658 ELLINGTON ROAD,SOUTH WINDSOR,CT Reviewed By 1 0 la ing)BP_#_27361_ Ph_#_(860)528-6054 Date Reviewed 7hrtw Mpprov enied Date Submitted 00/00/00 FOR O *** As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A V 1. Approved building permit plan V 2. Finish grading per approved building permit plan 3. Site work; i.e. trees, shrubs, dumpsters, required parking V 4. Utility location; a. sanitary sewe m i/ b. foundation drain C. electrical & telephone d. water e. other 5. Sewer connection charge paid 6. Appropriate certification 7. Bonding 8. Planning & Zoning/ Inland Wetlands Considerations A. Lighting B. Signage Freestanding Wall C. Fee in lieu of Open Space Sewer Permit No. ` 2 o 2- Pavement Excavation No. COMMENTS: S C SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 18 FRENCH LANE LOT_##43 Reviewed B 7r--g#JA jEn ineering) CLARK REALTY, INC. Date Reviewed oo Approve enied 658 ELLINGTON ROAD,SOUTH WINDSOR,CT Reviewed By anning) BP_##_27361_ Ph_##_(860)528-6054 Date Reviewed a9 ltJA pprovE Denied Date Submitted 09/29/00 FOR BUILDING PER In accordance with the Zoning and/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include: Apprgved Denied N/A 1. Name, address & phone number of owner/applicant V/ 2. Name, address & phone number of plan preparer 1600/_ 3. Zoning Information - i.e. zone, open space, floodway, street address. 4. Plot Plan at 1" = 40' scale a. Subdivision reference, abutr1or rt,'e, tc b. Easements of record c. Lot description, bearings, distances, area, etc. 2 9 2OW d. Contours, existing & propos ftintervalwhereappropriateUTHWINDSOR ENG.DEFT. e. Building location with dimensi"is. Elevations of proposed finish floor, arage floor & centerline of road at driveway' u----" f. Elevations of gravity drainage systems, sanitary foundation drain at the house and the street g. Tentative utility location (gas, water, electric, septic system, etc.) h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements. (P.E. & L.S.) 5. Sedimentation and erosion control 6. Special Planning & Zoning, Inland WetlandsPg9, considerations (Plans on file w/Town Clerk) COMMENTS: SCANNED PERMITDom, NT DECISION APPLICATION FOR ELECTRICAL PERMIT' A" 5 tion is hereby:TOWN of,SOUTH WINDSOR BUILDING DEPARTMENT Bldg Perini # 0 P6E 1540,SUI.LIVAN AVENUE f b44-2511 ext.230 DateNO Building Inspector Appucation must be printed or typed M Location ofjob U Street No. Street Lot No. SCHEDULE Floor =Apt.No. 0 ,000 - $12.00 r $1,000 I per$1,000 OWNER es,0sz"c!/o y ref? on thereof ADDRESS w4 ost., CT. Q OTjI OWNERS PHONE# APPLICANTS W N $ ADDRESS a`/ A 4 VVV 09 ESTIMATED COST$D J C f •. IS THIS A CONTRACT COST? I _ YES NO FEE ENCLOSED $ J OR-CO TYPE OF JOB: Y Original Installation Alteration/Addition/Repair Revised 11/95 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING RESIDENTIAL IS THIS APPLICATION ASSOCIATED WITH AIS PERMIT APPLICATION YES / NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY INSTITUTIONAL FACTORY STORAGE ENGINEER'S NAME PHONE GARAGE MIXED USE ADDRESS CITY STATE ZIP Other please specify) TYPE OF INSTALLATION/WIRING METHOD o4 r)z SIZE OF MAIN FEEDERS AND RATING OF WIRE USED NUMBER OF METERS r NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS REMOTE DISCONNECT REQUIRED?YES/NO NUMBER OF LIGHT CIRCUITS G NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES,NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES ,3 I NUMBER OF HEAT CIRCUITS PA-V' NUMBER OF A/C CIRCUITS W tit SEPERATE BEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK r y/G THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BU DING C E IN THE PERFORMANCE OF SUCH WORK. Ile 00 NAME STATE LICENSE NO. TYPE SIGN O ICANT PHONE NO. 0 D TE ` o n o ins-CRS Approvalon irma ion: eques o. age ij From: clpsvc@nu.com> To: COLLIN@SOUTHWINDSOR.ORG> Date:12/11/00 12:18PM Subject: CRS Approval Confirmation: Request No. 162492 Your approval of the following CRS Request has been successfully processed. CRS Work Request M 162492 House No: 18 rreA,h Lot No: 43 Street Name: Inspector:JOHN COLLINS Approval Date: Dec 11, 2000 IZ5UANNED] DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT PERMIT# Application is hereby:TOWN OF SOUTH WINDSOR G 7 t'I L1,4 BUILDING DEPARTMENT AP 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 7 Date Building Inspector Application must be printed or typed x,d FEE SCHEDULE S Location of Job: L e 0-$151000=$13.00 Street-No.o. Street Lot No. Over$1,000= 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT Q 1 n C APPLICANT ADDRESS I_ ,slog APPLICANT PHONE# OWN S OWNER OWNER ADDRESS 3 r`# OWNER PHONE 2, C ESTIMATED COST$00 IS THIS A CONTRACT COST? Yes 0 No FEE ENCLOSED$ U a TYPE OF JOB: SpR.CO 0,iQew Installation 0 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR PLUMBING PERMIT (Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL BUILDING PERMIT APPLICATION? /YES 0 BUSINESS CURRENT USE AND OCCUPANCY ASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCY EDUCATIONAL INSTITUTIONAL ENGINEER'S NAME PHONE FACTORY STORAGE ADDRESS GARAGE MIXED USE CITY STATE ZIP Other please specify) TYPE OF INSTALLATIONZ 2 SIZE OF MAIN DRAIN A NO.OF TOILETS_ STYLE ) • )o NO.URINALS STYLE NO.OF BATHTUBS NO.OF SHOWERS NO.OF LAVATORIES NO.OF CONDUCTORS SIZE NO.OF STACKS SIZE r AREA OF ROOF NO.OF CATCH BASINS NO.OF FLOOR DRAINS NO.OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW d11YES NO SIZE OF WINDOW Z X 2—. IF NONE C.F.M.OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER WATER HEATER: TYPE 0, MANUFACTURER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 2-0 z: ! R e- \ CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT Application is hereby:TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT w f P:P1k:0fVE!D 1540 SULLIVAN AVENUE i4 xj 644-2511 ext. 230 Date Building Inspector x tionAppfta muSt be Z ; ' s `4Ws x Location fJwFEESCHEDULE t "ter, 0-$1,000=$13.00 Street No. Over$1,000 q n 13.00 per$1 000 or any fraction thereof Tenant Designation APPLICANT rN 11174s APPLICANT ADDRESS q k APPLICANT PHONE# Ira-& ?S1 000 OWNERVINS ty .a OWNER ADDRESS t h: ,, ;fir z, .r; '' .. ill OWNER PHONE UAOVol ESTIMATED COST$ Vol IS THIS A CONTRACT C l?13 No I ArQFEEENCLOSED$ TYPE OF JOB: S( 0C 1 Original Installation 0 Alteratiollition/Repair APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE CQ SYSTEM: TYPE OF UILDING: HEATING RESIDENTIAL A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT-BTUH).. NET RATING(OUTPUT-BTUH) 1 -- TYPE OF FUEL OIL-GPM GAS-INPUT ELECTRIC-KW OIL TANK SIZE&LOCATION INSIDE OUTSIDE CAPACITY LPG TANK CAPACITY AIR CONDITIONING DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE J' \ 1 • B• A CALCULATION SHEET 1503 (Modem Mtthod)ce.,..tra 1 77 TR0"Veronica I,ratwlo rlf~EA AOORt>it a OtSIONTUM CAATUAt OIF CR[NCE--—F. CATSCL.A COL.• C L.C C L-D C L.t C L. C L.4 I ROOM L W M L W N L MI N L W N L W w watwl Tamp.ROOM OIMtNS/ONE.PT.' 0 L a 8'O3LENGTHtXOt+O WALLS.FT.BTU"ow wt•ttDIZA79tiRwlww•snwstw4w1NOOWA1r000TSIOEDOORAREAr O f WALL CONSTRUCTION STUN STUN STUN TUN STUN Table 9.Lmo3 a MI Q l000 900 600 U FAOYTo ALs ALeft FT. AOIAT r o• TYPE i GLASS Lures fs stLJiCTtO1Nt"0 wI tMM trtaf fw+Line 91 ery SQ goo oo7CEILINGCONSTRUCTION Q' pQITMMf.L WO O jfO Uo 0 O C r / S iLOOACONSTAUCTI N/ 0 iyaCOLOPAIKITMOCONSTRUCTION x Z- o0 ZOU f Tt MtofifsEflENCt• O 3O 7O 7O OO DSO f2 TOTALSTeI *r-o iSeGlw TtfMn:DIFFERENCE 4000 low COL-A COL-11 COL.N COL.I COL./ COL.K COL.L 430 W40 77 _Z7g f ROOM Ea11L BTWIDING RAO TAA. ONtATSELtCTEOONLN !f L W N L W N L w to L W OSSINM TtM.•2 ROOMDIME1fS1pNS.FT. 1 y o .o ofa<EwE«CE . a Lt TMt wALLS.FT. oswtNOOr"ANOOUTSIOE OOOR AREA TYK alrum STUN 8TUN BTU"f WIN"CONiTRYCT1p1 f 1IrC1lE BATHROOMITaeMOO:L v O OT1fEOi N Mwlw fws LinkW tiOR CONCRETE FLOOR ONiTMItCQROUNOORFILLAT iLOORCONSTRUCTIO/rt OS v Gil LEVEL.USE LINEAR L x Wwr Lift St.1 FEET Of Ex OSEO EDGE ARTtT10N CONSTRUCTION anNumb x .owIMMEOMwM«/N EAL MMI J I I TUlf AT 70P TtM.OIiFEREpill 31TUNATOESIGaTtMi.OIFFEAENCE Y 1 a+MM from TR 14V*r*AIes Inuplutd-36 RwG60 POS906 B0tRN0y M01eAtL N.J.07922 AM 1503 F ">+ DEPARTMENT DECISION APPLICATION FOR HVAC P Application is hereby:TOWN OF SOUTH WINDSOR BUILDING DEPAR'h APPROVED 540AVENUELIVAN 6"-251 230O/ Date Building Inspector APPlicatiolt Mutt be FEE SCHEDULE L of r.y xL iL3 _ 0-$1,000=$13.00 Street No. r . Over$1,000 13.00 per$1,000 or any fraction thereof Tenant Designation APPLICANT APPLICANT ADDRESS APPLICANT PHONE# N S OWNEROWWit OWNER ADDRESS pt, Er OWNER PHONE ESTIMATED COST$- IS THIS A COST?CONTRACT I r E 00, fii/ 1 Q ms "FEE ENCLOSED$ O TYPE OF JOB: rT,>.# , 9<ginal Installation 0 Alteration/Addition/Repair v APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF BUILDING: HEATING ERESIDENTIAL a-xiC COMMERCIAL VENTILATION INDUSTRIAL H ING LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) G HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL OIL—GPM GAS—INPUT ELECTRIC—KW OIL TANK SIZE&LOCATION INSIDE OUTSIDE CAPACITY LPG TANK CAPACITY AIR CONDITIONING DESIGN TEMP.OUTSIDE Y OF INSIDE 7cJ OF DIFFERENCE / OF TOTAL HEAT GAIN(BTUHQ /./b (HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING E UIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) 4 Dv VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE ORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. r s 7` CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE ' DETAILED REPORT FOR ENTIRE HOUSE Prepared For : Prepared By: Darthill Realty RP 658 Ellington Rd R&E Heating & Cooling So Windsor Ct 06074 Job Name: 243--043 EXPOSURE GLASS NORTH NE/NW EAST SOUTH SE/SW WEST HORZ . TOTAL AREA 20 : 0 : 150 20 : 0 113 : 01, 303 COOLING ; 268 : 0 ; 6 ,513 : 428 : 0 ; 4 ,907 : 0 ; 12 ,117 HEATING ; 802 : 0 ; 6 ,018 : 802 : 0 ; 4 ,534 , 0 ; 12 ,156 w_ BELOW WALLS NORTH NE/NW EAST SOUTH SE/SW WEST GRADE TOTAL AREA i 343 : 0 : 618 : 364i 0 : 631 Oi 1 ,956 COOLING ; 237 , 0 ; 427 : 252 : 0 ; 436 ; 0 ; 1 ,352 HEATING ; 9711 0 : 1 ,750 ; 1 ,030 ; 0 : 1 ,786 ; 0 : 5 ,5371 DOORS NORTH NE/NW EAST SOUTH SE/SW WEST TOTAL AREA 21 ; 0 ; 0 ; 0 ; 0 ; 42 , 63 COOLING i 66 : 0 : 0i 01, 0i 132i 199 HEATING 271 ; 0 ; 0 ; 0 ; 0 ; 543 ;814 FLOOR AREA COOLING HEATING 2226 i 0 ; 0 CEILING AREA COOLING HEATING 2226 1 ,073 1 ,972 MISCELLANEOUS COOLING LOADS People Sensible Load 4 ,275 Latent Load 8 ,399 Lights & Appl . Load 4 ,096 Latent Safety Btuh 420 Ventilation Load 2 ,200 Duct Heat Gain 1 ,956 Infiltration Load 728 Sensible Safety Btuh 1 ,302 TOTAL SENSIBLE LOAD 29 ,297 TOTAL LATENT LOAD 8 ,819 Air Changes/Hour 0 .00 Temp . Swing Mult . 1 .00 Total Cooling Load 38 ,116 BTUH Or 3 . 18 Tons MISCELLANEOUS HEATING LOADS Infiltration Load 9 ,907 Ventilation Load 14 ,960 Duct Heat Loss 5 ,381 Safety Btuh Total Heating Load 52 ,995 BTUH **=JSCA7NED] SUMMARY REPORT Prepared For : Prepared By: Darthill Realty RP 658 Ellington Rd R&E Heating & Cooling So Windsor Ct 06074 Job Name: 243-043 DESIGN CONDITIONS OUTDOOR INDOOR SUMMER WINTER SUMMER WINTER Dry Bulb 88 0 78 68 Wet Bulb 75 65 Daily Range 20 Daily Swing 3 .0 Latitude 41 Elevation 1100 Safety Factor ( o ) 5 Latent. Factor ( p ) 30 Room Heating Heating Cooling Cooling Name BTUH CF=M BTUH CFM Living Room 6 ,508 196 4 ,997 273 Foyer 1 ,557 47 1 , 148 63 Dining Room 2 ,586 78 2 ,719 148 Kitchen 5 ,571 168 4 ,790 262 Bedroom 1 18 ,011 544 7 ,086 387 Bedroom 2 2 ,472 75 1 ,618 88 Bedroom 3 3 ,777 114 2 ,460 134 Bedroom 4 2 ,896 87 2 ,300 126 Bathroom 9 ,432 285 2 ,082 114 92 J 49 3 92 49 52 ,995 1 ,600 29 ,297 1 ,600 HEATING DELTA T 30 .1 COOLING DELTA T 16 .6 NOTE : =k** Calculated Airflow is based upon load requirements . Verify that airflow calculated is compatible with selected equipment requirements . k* k SCANNE D