Loading...
HomeMy WebLinkAbout176 Oak Streett I s DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby: TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT 220 App 1540 SULLIVAN AVENUE Bldg.Permit# cc 644-2511 ext. 230 o3 JXe—, Date Building Inspector r Application must be printed or typed f Location of Job: FEE SCHEDULE 3fSri 0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= 15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANTCC) H A C APPLICANT ADDRESS Sum pz r_ r)e (o APPLICANT PHONE# f 6 U 1(Q c? W H $t OWNER /14 G e n F. I/q OWNER ADDRESS OWNER PHONE ESTIMATED COST$ f3 C i t IS THIS A CONTRACT COST? t/4es No FEE ENCLOSED$ o TYPE OF JOB: OR-Cod k New Installation Alteration/Addition/Repair Revised 4101H2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: HEATING RESIDENTIAL JAI COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH) F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) TYPE OF FUEL OIL—GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE ns COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFMr- PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. S- 1 -)a -)cl47 F CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT 01. DATE Page 1 Resid ntial Heat Loss and Heat Gain Calculation 7/7/2003 In accordanc with ACCA Manual J Report Prepared By: Tin Works Inc. For: Geoffroy House South Windsor, CT Design Conditions: South Windsor Indoor: Outdoor. Summer temperature: 68 Summer temperature: 97 Winter temperature: 76 Winter temperature: 4 Relative humidity: 55 Summer grains of moisture: 86 Daily temperature range: High Building Component Sensible Latent Total Total Gain Gain Heat Gain H at Loss BTUH) BTUH) BTUH) BTUH) Whole House 1,223 sq.fL 19,303 31670 22,973 429904 2tons) Second Floor— - -_ -- -- 19,303 ------ ^ 3,671__ 22,974 42,903 Master Bedroom 240 sq.ft. -_ 4,179 1,015 5,194 71551 Bedroom#2 240 sq.ft. 3,519 555 4,074 7,551 Hall 120 sq.ft. 304 0 304 530 Bedroom#3 192—sq.ft. 2,636 ---------- ----370 3,006 4,939 Bathroom- — _— 96 sq.ft`-- 1,079 139 _ _1,218 2,046 Living Room-downstairs 225 sq.ft. 5,027 1,384 __ 6,411 16,317 Kitchen-Downstairs 110 sq.ft. 2,559 208 2,767 3,969 VYiMb#louse 1,223 sq.tL 19,303 39670 229973 429904 2tons) HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates ongr,actual loads may wary due to weather and lion differences. Page 1 Resid ntial H at Loss and H at Gain Calculation 7/7/2003 In accordance with ACCA Manual J Report Prepared By: Tin Works Inc. For: Geoffroy House South Windsor, CT Total CFM: 800 Room Cooling CFM Heating CFM Both Second Floor 800 800 800 Master Bedroom 173 141 173 Bedroom#2 146 141 146 Hall 13 10 13 Bedroom#3 ------------------- ----- 109 ----------- 92 ----------- 109 Bathroom 45 38 45 Living Room-downstairs_____ 208 304 304 Kitchen-Downstairs 106 74 106 HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only,actual loads may very due to weather and construction differences.