Loading...
HomeMy WebLinkAbout17 Green Lane (3)r 7Appl'RTMENT DECISION APPLICATION FOR 1 VAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# hereby: yBUILDINGDEPARTMENT APPROVE 1540 SULLIVAN AVENUE Bldg.Permit# 644-2511 ext. 230 Date Bui g Inspector Application must be printed or typed Location of Job: FEE SCHEDULE q r 0-$1,000=$15.00 Street No. Street Lot No. Over$1,000= 15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT de&K tLevJ(W6 0 Cool(A)4 APPLICANT ADDRESS /Y 2 141leI N S C'?71 Q&d,6) r APPLICANT PHONE# Y i3 S IS7 ff6-67 OWN S OWNER Oczr K d P,81oK 1 /q OWNER ADDRESS e(Z 41-6 AI dty tNss y/C OWNER PHONE WA ZS`Op1so I O Y I • ESTIMATED COST$ YQ0- OQ IS THIS A CONTRACT COST? Yes No FEE ENCLOSED$ 4- TYPE OF JOB: OR-Co 1--New Installation Alteration/Addition/Repair f Revised 4/01//2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: HEATING k RESIDENTIAL A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC q WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE 70 OF INSIDE 22_°F DIFFERENCE 014 OF TOTAL HEAT LOSS(BTUH) 7rfNo?7 °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DE CRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) id e-gtcjClxc GROSS HEATING CAPACITY(INPUT—BTUH) / _ 0 NET RATING(OUTPUT—BTUH) $3,6a9 TYPE OF FUEL 1 _Q OIL--GPM OIL TANK LOCATION A INSIDE OUTSIDE CAPACITY 1 J GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING r DESIGN TEMP.OUTSIDE OF INSIDE 7-S OF DIFFERENCE 3 OF TOTAL HEAT GAIN(BTUH) HEAT(HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) F`n mn jas-eer- 4 AJ TONNAGE 4/Ton1 COOLING CAPACITY(BTUH)lff-(Cv VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 90,598 5-1- NTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE_ /Oh, RIGHT-J LOAD AND EQUIPMENT SUMMARY Entire House DESLOK HTG/COOL Job: 4-S"-bL 141 ALLEN S+.EAST LONGMEADOW,MA Phone:413-525-0809 Project • For. tJ_ Notes: Desi•Ln Information Weather: Hartford, Brainard Field, CT, US Winter Design Conditions Summer Design Conditions Outside db 6 OF Outside db 88 OFInsidedb70 °F Inside db 75 TDesignTD64IFDesignTD13 'OF Daily range M Relative humidity 50 % Moisture difference 28 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Building heat loss 74077 Btuh Structure 44757 BtuhVentilationair0cfmVentilation0BtuhVentilationairloss0otuhDesigntemperatureswing3.0 °FDesignheatload74077BtuhUsemfg. data n Rate/swing multiplier 0.93 Infiltration Total Sens. equip. bad 41624 Btuh MetConstruction quality Avelraggee Latent Cooling Equipment Load SWng Fireplaces 0 Internal gains 2990 Btuh Ventilation 0 BtuhHeafFnaCoglinInfiltration4028BtuhArea(fe)r 740 1aq Total latent equip. load 7018 BtuhVoris(f?) 32136 Air channggees/t ur 0.7 0.4 Total equipment load 48642 StuhEquiv.AVF(cfm)376 215 Heating Equipment Summary Cooling Equipment Summary Make MakeTradeTrade Efficiency 80.0 AFUE Efficiency 10.0 EERHeatinginput0BtuhSensiblecooling 0 BtuhHeatingoutput0BtuhLatentcooling0BtuhHeatingtemprise0 °F Total cooling h8tuActualnestingfan2393cfmActualcoolingfan239 0 Btu 3 cfmHeatingairflowfactor0.032 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh Space thermostat Load sensible heat ratio 86 % Printout certified by ACCA to meet all requirements of Manual J 7th Ed. vvrKgtitsoft RVH-Suite ResidenlW-5.0.38 RSRRUD26387 ProjW1 rsr RIGHT-J SHORT FORM Entire House DEBLOK HTG/COOL Job: 141 ALLEN ST.EAST LONWEADOW,MA Ph&*:413-525-MM Project • For: r F- Design Information Htg CIg InfiltrationOutsidedb(OF) 6 88 Method SimplifiedInsidedb(OF) 70 75 Construction quality AverageDesignTD(OF) 64 13 Fireplaces Daily range M Inside humidity(°k) 50 Moisture difference(gr/lb) - 28 HEATING EQUIPMENT COOLING EQUIPMENTMakeMakeTradeTrade Efficiency 80.0 AFUE Efficiency 0.0 EERHeatinginput105,000 Btuh Sensible cooling 0 BtuhReefingoutput93,000 Btuh Latent cooling 0 BtuhHeatir9temperaturerise0OFTotalcooling0BtuhActualheatingfan2393cfmActualcoolingfan2393cfmHeatingairflowfactor0.032 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh Space thermostat Load sensible heat ratio 86 ROOM NAME Area Htg load CIg load Htg AVF CIg qyFft) Btuh) Btuh) cfm) Cfm) MUDROOM 144 3243 2003 105STUDY 0719249113125159167BREAKFAST19255192789178149KITCHEN2402416343178FOYER1683557805115 184 LIVING ROOM 4327268693687222197DININGROOM22462114196201224 BEDROOM 4 165 3172 2575 102 138BATH/CLOSET 90 1767 616 57 33HALUBATHSTAIRS12113483554419BEDROOM31923020122198BEDROOM216832881690106 fi5 HALL BATH 60 1 1 90 MASTER BEDROOM 256 5704 3457 1847 12 185 Printout certified by ACCA to meet all requirements of Manual J 7th Ed. WrlghtS )ift RVO-Suite ReWeftal-5.0 38 RSRRUD26387 Pmodi nr 2001-Iv pop 1