Loading...
HomeMy WebLinkAbout17 Cityview TerraceElectric# APPLICATION FOR BUILDING PERMIT Plumbing# 17 CTTYVIE;W TERRACE HVAC # F UNDATION ONLY '2 3 9 81` Date: % 19 9wQ_ JSprinkler# FINAL APPRQYALS Estimated Cost $ 5-D0 D Oz Building AWfl 0-1 Jae_IDDCOMPLETE RED BOXED AREAS Permit Fee r,C Engineering TYPE OR PRINT ONLY Occupancy Fee $ Affidavit SIGN ON REVERSE SIDE Appr.for CO. Total Fee TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR,CT Additional Cost) $ Th undersigned hereby applies to do work according to the following specifications: Job Location O'l C`/T 114:0 Z'Z'.f'-'}CC Lot No.Side of Street Zone Applicant Tel.# 4 l/4/--5-2E 8 Address 276 A'i/V&AoV't V,4L,L E Zip Lic. # Own r f t,4,,J jFDc-J,4-r'n S Address Architect LOP t 6 (1- t Address Sq. Ft.New Area: Ist FI. 2nd Fl. 3rd FI. Total New Area /(/OC) Rooms Lavatories Bathrooms Garages 1 Purpose of this permit: U N LL Y L,F L 4 . City Water n , Well Septic System Sewer :-Lll Us Group Construction Type a Area Bas m nt Garage Approved by Date 111,5197- Revised 6/95 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked, and agree that this building is to be located the proper distance from all street lines, side yard lines and required distances from all other zones and is located in a zone in which this building and its lowed. Signed I hereby apply for a Certificate of Occupancy for the work described in this application for the permit Signed DO NOT WRITE BELOW THIS LINE -- INSPECTION COMMENTS Sectfio# 3 7 APPLICATION FOR BUILDING PERMIT Plumbing#fl 01 17 CITYVIEW TERRACE WVAC # UNIT 10 24239 Date: 7ze? Sprinkler# FIK APPROVALS Estimated Cost 701000 Building _7//rh7 V< COMPLETE RED BOXED AREAS Permit Fee OccupancyFee $ n i a I TYPE OR PRINT ONLY AffidavitAt for CO.Total FeeSIGNONREMERy7AdditionalCost) i TO BUI ARTMB4,TOWN OF SOUTH Wm*m CT The undersigned hereby applies to do work according to the following specifications: UI% Job Location C"7 /L•-,t' '14c Lot No. Z Side of Street Zone Applicant(BIM .5rAQ j Qe,A 9' C .Z-V C. Tel# A SY-12 C9 Addr ss 7 l-, PL FA-SAM" 1,/R l L C APD Zip d O2 Lic.# Own r 6B.. O(ArV ,5P WAW;? D S Address a b P6ND 1-e4 . S • W Architect 7:%:A A) [jj f t G if[- Address Sq.Ft.N w Area: 1st Fl. l Vo y 2nd Fl. 3rd Fl. Total New Area / Q Rooms Lavatories Bathrooms ,j, Garages Purpose of permit: IF # _ el d City Water Well Septic System Sewer Ins. H.O. S.P. Cart. Area U Basement Garage Approved by Date `~ Use Group Construction Typwa RevbW 1/97 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines,and required distances from all other zones and is located in which this buildng and' is allowed. Signed01 I hereby apply for a Certificate of Occupancy for the described in this application for the permit. Signed xf)- DO NOT WRITE BELOW THIS LINE INSPECTION COMMENTS Location of Job: AFFIDAVIT Additional Fee S ,3G State of Connecticut ss.South Windsor County of Hartford Owner I iJ ems of7`i''r,,i Agent for the building erected Contractor under Permit No. 2 4 2 3 9/2 3 9 81 issued by the Building Department of the Town of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized under said permit did not exceed the most current accepted BOCA value of S 8 8 . 9 2 8 . 0 0. Signed Subcribed and sworn to before me this Z` day of 7J-t/ A.D. 19-?, Estimated Cost S 85 9 3 7 . 0 0 Difference: S 2,9 91 . 0 0 Notary Public Inspection / Approval Date By Appl Code Description Due Whom Code Comment 97-24239-B 70,000 E01 SERVICE 05/06/97 JFH A RELEASED OK P03 ROUGH 05/14/97 JFH A PO4 GAS TEST 05/21/97 JFF A AIR TEST B03 FRAMING (ROUGH) 05/27/97 JFF A E03 ROUGH 05/27/97 JFF A B04 INSULATION 05/28/97 JFF A B04 INSULATION 05/29/97 JFF A B10 FINAL 07/18/97 JFH A 97-9941-P 3,000 97-9760-H 4,937 97-14379-E 3,000 Total Est Value 80,937 6600 T N Dwelling 1,404 57,451.68 Basement 1,377 17,074.80 Garage 294 3,645.60 Smoke Det 7 525.00 BOCA Value 88,927.70 Difference 9,990-; LeLAI— dv 2b.r 95 g 3 SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNERCTICUT L 17 CITYVIEW TERRACE LOT_#10 Reviewed By R. DOA06It En ineering) B & M ENTERPRISES Date Reviewed y p roved enied 376 PLEASANT VALLEY RD,SOUTH WINDSOR,C Reviewed By Pe 7 Planning) BP_#_24239_ Ph_#_(203)528-5418 Date Reviewe 7a 7 Denied Date Submitted 07/23/97 FOR C of 0 ***** As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A Rb 1. Approved building permit plan 2. Finish grading per approved building permit plan 3. Site work; i.e. trees, shrubs, dumpsters, required parking 4. Utility location; a. sanitary sewer/septic system b. foundation drain RD c. electrical & telephone 0 d. water Kb- e. other jQS IZ 5. Sewer connection charge paid 6. Appropriate certification 7. Bonding 8. Planning & Zoning/ Inland Wetlands Considerations Sewer Permit No. s Pavement Excavation No. COMMENTS: JC- 7' 6OIthq di-uch drvJ -SQh,'Ay 54lv2t' D 17 Ts heed '''2voej pArn 7/ay1 q7 Kjr g SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 17 CITYVIEW TERRACE LOT_#10 Reviewed By ( j 4 H-t Bering) B & M ENTERPRISES Date Reviewed Approve enied 376 PLEASANT VALLEY RD,SOUTH WINDSOR,C Reviewed By Planning) BP_#_23981_ Ph_#_(203) 528-5418 Date Reviewe 7 pproved Denied Date Submitted 01/09/97 FOR DING P In accordance with the Zoning and/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include: Approved Denied N/A 6 0— 1. Name, address & phone number of owner/applicant 90 2. Name, address & phone number of plan preparer 4 3. Zoning Information - i.e. zone, open space, floodway, etc. D— 4. Plot Plan at 1" = 40' scale a. Subdivision reference, abutting properties, etc b. Easements of record c. Lot description, bearings, building lines, distances, area, etc. d. Contours, existing & proposed, 1 or 2 ft. interval where appropriate e. Building location with dimensions. Elevations of proposed finish floor, garage floor & centerline of road at driveway Rf. Elevations of gravity drainage systems, sanitary 10A foundation drain at the house and the street g. Tentative utility location (gas, water, electric, septic system, etc.) h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements. (P.E. & L.S.) 5. Sedimentation and erosion control 6. Special Planning & Zoning, Inland/Wetlands considerations (Plans on fi Clerk) COMMENTS: JAN 1997 a ice f DEPARTMENT DECISION PERNIlTAPPLICATIONFORELECTRICALPERMIT4-3-7 Application is hereby: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT N-;?Permi APPROVED 1540 SULLIVAN AVENUE G 644-2511 ext. 230 ate Building Inspector Application must be printed or typed Location ofjob 7 Crf-YweLj reklw- IJA(,(94 Street No. Street Lot No. FEE SCHEDULE 0 - $1,000 - $12.00 moor Apt.No. Over $1,000 12.00 per$1,000 OWNER 06&41oranyfractionthereof ADDRESS 776 Gd Z SO r lt LAG f0 G7r- Go C 7T" OWNERS PHONE# APPLICANT Z'atel id., lzewQle, i I, GEiGfij'1G,,t . O ADDRESSWN $ 4 CPA r ll EST04ATED COST$ Q@0. C) C IS THIS A CONTRACT COST? YES NO FEE ENCLOSED $ Q f OR-CO TYPE OF JOB: Original Installation Alteration/Addition/Repair Revised 11/95 APPLICATION FOR ELECTRICAL PERMIT(Continued from reverse side) TYPE OF BUILDING 1S THIS APPLICATION ASSOCIATED WITH A RESIDENTIAL BUILDING PERMIT APPLICATION YES / NO BUSINESS ASSEMBLY CURRENT USE AND OCCUPANCY MERCANTILE EDUCATIONAL FUTURE USE AND OCCUPANCY INSTITUTIONAL FACTORY STORAGE ENGINEER'S NAME PHONE GARAGE MIXED USE ADDRESS CITY STATE ZIP Othcr please spccify) MMMMMMMEW TYPE OF INSTALLATION/WIRING METHOD ot OA t ex SIZE OF MAIN FEEDERS AND RATING OF WIRE USED 2Af- t, tL NUMBER OF METERS_I NUMBER OF DISCONNECTS AND RATINGS NUMBER OF PANELS l REMOTE DISCONNECT REQUIRED?YES/do NUMBER OF LIGHT CIRCUITS NUMBER OF POWER CIRCUITS NUMBER OF SWITCHES NUMBER OF OUTLETS NUMBER OF LIGHT FIXTURES NUMBER OF HEAT CIRCUITS NUMBER OF A/C CIRCUITS SEPER.ATE HEAT LOSS AND A/C CALCULATIONS MUST BE SUBMITTED. DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN. BUILDING CODES IN PERFORMANCE OF SUCH WORK. NAME STATE LICENSE NO. TYPE SI ATURE OF APPLICANT PHONE NO. S d 0 "0137 DATE 51 n4"..a#a:t:snaK Mt•i''+t ba, xm.•"''-^'_'l"eC„9cny;> 1 ,,,, i '^ ,,,-"'ss_:k-a,• IN4rECTOR ' DATE vb TIME LOCATION ol INSPECTION: CODE: RESULT(D/A) : BUILDING: ELECTRICAL: PLUMBING: s a HVAC: OTHER: ak 1 oj—. DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT P FI Application is hereby: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Pe # APPROVED 1540 SULLIVAN AVENUE 7 iAq 644-2511 ext. 230 r Date Building Inspector Application must be printed or typed Location ofjob l-7 ct "112< fo Street No. Street Lot No. FEE SCHEDULE Floor Apt. No. 0 - $1,000 - $12.00 Over $1,000 12.00 per$1,000 J C or an fraction thereof OWNER tf- /vl (w7Zzr Jitt 5 y ADDRESS S 6 9 c D So& OWNERS PHONE# APPLICANT 0WNN S ADDRESS g Cv STD'-"-- S T G?o, Q K , c141mw- 0 3027Z ESTIMATED COST IS THIS A CONTRACT COST? YES NO 1 r C FEE ENCLOSED $ f OR-CO E OF JOB: G11 Original Installation Alteration/Addition/Repair Revised 10/96 APPLICATION FOR PLUMBING PERMIT(Continued from reverse side) TYPE OF BUILDING IS THIS APPLICATION ASSOCIATED WITH A BUILDING PERMIT APPLICATION YES / NO RESIDENTIAL BUSINESS CURRENT USE AND OCCUPANCY ASSEMBLY MERCANTILE FUTURE USE AND OCCUPANCY EDUCATIONAL INSTITUTION FACTORY ENGINEER'S NAME PHONE STORAGE GARAGE ADDRESS MIXED USE CITY STATE ZIP Other please specify) TYPE OF INSTALLATION SIZE OF MAIN DRAIN NO. OF TOILETS STYLE NO. OF URINALS STYLE NO. OF BATHTUBS NO. OF SHOWERS NO.OF LAVATORIES NO. OF CONDUCTORS SIZE NO.OF STACKS SIZE AREA OF ROOF NO. OF CATCH BASINS NO.OF FLOOR DRAINS NO. OF OTHER FIXTURES KIND ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW YES/NO SIZE OF WINDOW IF NONE C.F.M. OF VENTILATOR SIZE OF DUCTS SEWER OR SEPTIC TANK SIZE OF WATER MAIN SIZE OF WATER PIPING&RISER WATER HEATER TYPE MANUFACTURE TANKS SAFETY DEVICES TEMPERATURE CAPACITY RELIEF VALVE TEST PRESSURE WORKING PRESSURE PRESSURE RELIEF VALVE TYPE MANUFACTURER DESCRIPTION OF WORK Zlq-U THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. l za z3?y c7--. NAME STATE LICENSE NO. TYPE SIGNATURE OF APPLICANT PHONE NO. 1S 3 - 0 33 DATE 3^ DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT 9-7 PER(o#l Application is hereby: TOWN of SOUTH WINDSOR BUILDING DEPARTMENT Bldg Permi # APPR VED 1540 SULLIVAN AVENUE 644-2511 ext. 230aqr5a-- Date Building Inspector Application must be printed or typed Location of job7/ 77 7e r ro-&-4t, 0 Street No. Street Lot No. FEE SCHEDULE Floor Apt. No. 0 - $1,000 - $12.00 Over $1,000 12.00 per$1,000 OWNER 94e- Y(e r'c -S or any fraction thereof ADDRESS 3 7(o l @ asa tL ble LtJ' •r s r h O w o`w7 OWNERS PHONE# APPLICANT e n OWN Sk ADDRESS 6 lXAA-Y ,ec q< Gam . ESTIMATED COST $ 473 7. 3 C IS THIS A CONTRACT COST? YES NO C!FEE ENCLOSED $ (O Q dsOR-C i OF JOB: t Original Installation Alteration/Addition/Repair Revised 11/95 APPLICATION FOR HVAC PERMIT(Continued from reverse side) TYPE OF SYSTEM TYPE OF BUILDING HEATING RESIDENTIAL L/ A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS.HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR zl---- UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE _5__ F INSIDE 7 2,F DIFFERENCE k F TOTAL HEAT LOSS(BTUH) /10 HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE&MODEL NO.) s GROSS HEATING CAPACITY (INPUT-BTUH) ZS NET RATING (OUTPUT-BTUH) c TYPE OF FUEL OIL-GPM GAS-INPUT 7.5 ELECTRIC-KW OIL TANK SIZE&LOCATION INSIDE OUTSIDE CAPACITY LPG TANK CAPACITY AIR CONDITIONING DESIGN TEMP. OUTSIDE F INSIDE& F DIFFERENCE F TOTAL HEAT GAIN(BTUH)_ -_ HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE&MODEL NO) TONNAGE COOLING CAPACITY(BTUH)C _ b&`D VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK l THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONN.BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 5c),_3 6- It' STATE LICENSE-NO. NAME&TYPE SIGNA E OF PLICANT PHONE NO'94 0 DATE 7 -7 HEAT, INC. PROJECT: Typ A2 9 FLAGSTONE DRIVE *CLIENT: B Edwards HUDSON, NH 03051 *DATE: 7/96 RESIDENTIAL/LIGHT COMMERCIAL HVAC LOADS DESIGNER: J. Cowl e DESIGN CONDITIONS: DESIGN PARAMETER SUMMER WINTER OUTDOOR DRY BULB TEMPERATURE 90 DEG.F 5 DEG.F INDOOR DRY BULB TEMPERATURE - ZONE 1 76 DEG.F 72 DEG.F DESIGN TEMPERATURE DIFFERENCE - ZONE 1 14 DEG.F 67 DEG.F INDOOR-OUTDOOR GRAINS DIFFERENCE 35 GRAINS OUTDOOR DAILY TEMPERATURE RANGE MED TOTAL BUILDING LOADS: BLDG. LOAD AREA SEN. LAT. + SEN. - TOTAL DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN 3-A WINDOW DBL PANE CLR GLS WOOD FR 156 51761 0 61490 60490 12-J WALL R-11 + R-8 SHEATHING 866 2,900 0 762 762 10-G DOOR WOOD PANEL 42 1,886 0 496 496 16-G CEILING R-30 INSULATION 1,077 2,381 0 1,351 1,351 19-B FLOOR/ENCL CRAWL HARDWD + R-11 11077 2,887 0 0 0 SUBTOTALS FOR STRUCTURE: 3,218 15,815 0 9,099 9,099 PEOPLE 7 0 11610 2,100 3,710 APPLIANCES 0 0 21500 1,200 31700 DUCTWORK 0 0 0 0 0 INFILTRATION W.CFM: 71.8 S.CFM: 71.8 0 5,292 11709 1,106 2,815 VENTILATION W.CFM: 0.0 S.CFM: 0.0 0 0 0 0 0 SENSIBLE GAIN TOTAL 13,505 TEMP. SWING MULTIPLIER X 1.00 BUILDING LOAD TOTALS 21,105 5,819 13,505 19,324 SUPPLY CFM AT 20 DEG DT: 614 CFM PER SQUARE FOOT: 0.570 SQUARE FT. OF ROOM AREA:1,077 SQUARE FOOT PER TON: 668.806 TOTAL TONNAGE REQUIRED WITH OUTSIDE AIR: 1.610 TONS CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J. ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY. BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS. RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY YORK INTERNATIONAL INC *** HEAT, INC. **HUDSON, NH 03051 Type A2 7/96 PAGE 2 TOTAL ZONE LOADS FOR ZONE I 1 *********************** BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAL DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN 3-A WINDOW DBL PANE CLR GLS WOOD FR 156 51761 0 6,490 61490 12-J WALL R-11 + R-8 SHEATHING 866 21900 0 762 762 10-G DOOR WOOD PANEL 42 11886 0 496 496 16-G CEILING R-30 INSULATION 11077 21381 0 1,351 1,351 19-B FLOOR/ENCL CRAWL HARDWD + R-11 1,077 21887 0 0 0 SUBTOTALS FOR STRUCTURE: 31218 15,815 0 9,099 91099 PEOPLE 7 0 1,610 2,100 31710 APPLIANCES 0 0 2,500 1,200 3,700 DUCTWORK 0 0 0 0 0 INFILTRATION W.CFM: 71.8 S.CFM: 71.8 0 5,292 1,709 11106 21815 VENTILATION W.CFM: 0.0 S.CFM: 0.0 0 0 0 0 0 SENSIBLE GAIN TOTAL 13,505 TEMP. SWING MULTIPLIER X 1.00 BUILDING LOAD TOTALS 21,105 5,819 13,505 19,324 ZONE SUMMARY FOR ZONE # 1 SUPPLY CFM AT 20 DEG DT: 614 CFM PER SQUARE FOOT: 0.570 SQUARE FT. OF ROOM AREA:1,077 SQUARE FOOT PER TON: 668.771 TOTAL TONNAGE REQUIRED WITH OUTSIDE AIR: 1.610 TONS RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY YORK INTERNATIONAL INC *** HEAT, INC. * HUDSON, NH 03051 Type A2 7/96 PAGE 3 ZONE # 1 AIR QUANTITIES ************************** r-r-------------------------------- RM ROOM AREA ------ HEATING ------ ------ COOLING ------ NO. DESCRIPTION SF) BTUH % TOT CFM BTUH % TOT CFM 1. kit,living,dining 576 12,492 59.2 162 6,543 48.4 297 2. mast r b drm 224 41069 19.3 53 31179 23.5 145 3. s cond b drm 169 2,970 14.1 39 2,070 15.3 94 4. mast r b drm bath 54 787 3.7 10 857 6.3 39 5. bath & hall 54 787 3.7 10 857 6.3 39 6. 0 0 0.0 0 0 0.0 0 7. 0 0 0.0 0 0 0.0 0 8. s cond b drm 0 0 0.0 0 0 0.0 0 9. 0 0 0.0 0 0 0.0 0 10. 0 0 0.0 0 0 0.0 0 ZONE SUBTOTAL 11077 21,105 100.0 274 13,506 100.0 614 LATENT GAIN 5,819 ZONE TOTALS 21,105 19,325 1.610 TONS RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY YORK INTERNATIONAL INC *** HEAT, INC. **HUDSON, NH 03051 Typ A2 7/96 PAGE 4 MISCELLANEOUS PROJECT DATA ******** **************** GENERAL PROJECT DATA: PROJECT DATA FILE NAME: C:COLLINSX FLOOR PLAN: Type A2 CLIENT NAME: B Edwards CLIENT ADDRESS: 644-5288 trailer CLIENT CITY & STATE: HARTFORD, CONNECTICUT TOTAL GROSS WALL AREA (SF) : 11064.00 NON-GLASS DOOR AREA (SF) : 42.00 TOTAL NET GLASS AREA (SF) :156.00 TOTAL SKYLIGHT AREA (SF) : 0.00 TOTAL NET WALL AREA (SF) :866.00 TOTAL NET ROOF AREA (SF) : 11077.00 TOTAL EXPOSED AREA (SF) : 2,141.00 PEOPLE LATENT LOAD MULTIPLIER:230.00 PEOPLE SENSIBLE LOAD MULTIPLIER:300.00 LATITUDE DEGREES: 41.00 TEMPERATURE SWING MULTIPLIER:1.00 EXTERNAL SHADING TYPES: NO. OVERHANG OFFSET 1. 0.0 0.0 2. 0.0 0.0 3. 0.0 0.0 4. 0.0 0.0 5. 0.0 0.0 6. 0.0 0.0 7. 0.0 0.0 OUTSIDE AIR DATA: SUMMER WINTER INFILTRATION AIR CHANGES PER HOUR: 0.500 0.500 CUBIC FEET OF CONDITIONED SPACE: X 81616 X 81616 4,308 41308 X 0.0167 X 0.0167 TOTAL BUILDING INFILTRATION CFM:71.8 71.8 TOTAL BUILDING VENTILATION CFM: 0.0 0.0 INFIL. & VENT. SEN. GAIN MULTIPLIER: 15.40 = (1.10 X 14 SUMMER TEMP.DIFF. ) INFIL. & VENT. LAT. GAIN MULTIPLIER: 23.80 = (0.68 X 35 GRAINS DIFFERENCE) INFIL. & VENT. SEN. LOSS MULTIPLIER: 73.70 = (1.10 X 67 WINTER TEMP.DIFF. ) RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY YORK INTERNATIONAL INC *** HEAT, INC. **HUDSON, NH 03051 Typ A2 7/96 PAGE 5 DETAILED ROOM LOADS ***************************** ITEM AREA -U- HTG SEN. CLG LAT. SEN. DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN 1. kit,living,dininq 32.0 WID X 18.0 LEN = 576 SF CEIL.HT a 8.0 S -WALL-12J 8 X 32 205 0.050 3.4 687 0.9 0 180 N -WALL-12J 8 X 8 7 0.050 3.4 23 0.9 0 6 W -WALL-12J 8 X 13 98 0.050 3.4 328 0.9 0 86 N -WALL-12J 8 X 12 84 0.050 3.4 281 0.9 0 74 S -DOOR-10G 7 X 3 21 0.670 44.9 943 11.8 0 248 N -DOOR-10G 7 X 3 21 0.670 44.9 943 11.8 0 248 S -GLAS-3A 2-P 0-1 S-1 0$S 12 0.551 36.9 443 35.6 0 427 S -GLAS-3A 2-P 0-1 S-1 0$S 12 0.551 36.9 443 35.6 0 427 S -GLAS-3A 2-P 0-1 S-1 0$S 6 0.551 36.9 222 35.7 0 214 N -GLAS-3A 2-P 0-1 S-1 100%S 36 0.551 36.9 11329 20.6 0 742 W -GLAS-3A 2-P 0-1 S-1 0$S 6 0.551 36.9 222 69.7 0 418 N -GLAS-3A 2-P 0-1 S-1 100%S 12 0.551 36.9 443 20.6 0 247 CEIL-16G DARK 18 X 32 576 0.033 2.2 11274 1.3 0 722 FLOOR-19B 18 X 32 576 0.080 2.7 11544 0.0 0 0 INFILTRATION W: 45.7 S: 45.7 126 26.7 31367 5.6 1,087 704 PEOPLE 2 230 300 460 600 APPLIANCES 1,500 11200 ROOM TOTALS 12,492 30047 6,543 2. mast r b drm 16.0 WID X 14.0 LEN - 224 SF CEIL.HT = 8.0 N -WALL-12J 8 X 14 100 0.050 3.4 335 0.9 0 88 E -WALL-12J 8 X 16 104 0.050 3.4 348 0.9 0 92 N -GLAS-3A 2-P 0-0 S-1 100%S 12 0.551 36.9 443 20.6 0 247 E -GLAS-3A 2-P 0-0 S-1 O%S 12 0.551 36.9 443 69.6 0 835 E -GLAS-3A 2-P 0-0 S-1 0$S 12 0.551 36.9 443 69.6 0 835 CEIL-16G DARK 14 X 16 224 0.033 2.2 495 1.3 0 281 FLOOR-19B 14 X 16 224 0.080 2.7 600 0.0 0 0 INFILTRATION W: 13.1 S: 13.1 36 26.7 962 5.6 311 201 PEOPLE 2 230 300 460 600 ROOM TOTALS 41069 771 3,179 RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY YORK INTERNATIONAL INC *** HUDSON, NH 03051 HEAT, INC. *PAGE 6 Typ A2 7/96 DETAILED ROOM LOADS ***************************** ITEM AREA -U- HTG SEN. CLG LAT. SEN. DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN ___GAIN 3. second b drm 13.0 WID X 13.0 LEN = 169 SF CEIL.HT = 8.0 92 0.050 3.4 308 0.9 0 81 S -WALL-12J 8 X 13 E -WALL-121 8 X 13 92 0.050 3.4 308 0.9 0 81 S -GLAS-3A 2-P 0-0 S-1 0$S 12 0.551 36.9 443 35.6 0 427427 E -GLAS-3A 2-P 0-0 S-1 O%S 12 0.551 36.9 443 69.6 0 835 CEIL-16G DARK 13 X 13 169 0.033 2.2 374 1.3 0 212 0 FLOOR-19B 13 X 13 169 0.080 2.7 453 0.0 0 INFILTRATION W: 8.7 S: 8.7 24 26.7 64230 5.6 207 230 134 PEOPLE 1 300 ROOM TOTALS 21970 437 21070 4. master b drm bath 6.0 WID X 9.0 LEN = 54 SF CEIL.HT = 8.0 42 0.050 3.4 141 0.9 0 37 E -WALL-12J 8 X 6 18 E -GLAS-3A 2-P 0-0 S-1 0$S 6 0.551 36.9 222 69.7 0 468 CEIL-16G DARK 9 X 6 54 0.033 2.2 119 1.3 0 54 0.080 2.7 145 0.0 0 0 FLOOR-19B 9 X 6 34 INFILTRATION W: 2.2 S: 2.2 6 26.7 160 5.6 52 PEOPLE 1 230 300 230 300 500 0 APPLIANCES ROOM TOTALS 787 782 857 5. bath & hall 6.0 WID X 9.0 LEN = 54 SF CEIL.HT = 8.0 42 0.050 3.4 141 0.9 0 37 E -WALL-12J 8 X 6 18 E -GLAS-3A 2-P 0-0 S-1 0$S 6 0.551 36.9 222 69.7 0 468 CEIL-16G DARK 9 X 6 54 0.033 2.2 119 1.3 0 080 2.7 145 0.0 0 0 54 0.FLOOR-198 9 X 6 6.7 160 5.6 52 34 INFILTRATION E7: 2.2 S: 2•2 6 230 300 230 300 PEOPLE 1 500 0 APPLIANCES 787 782 857 ROOM TOTALS