Loading...
HomeMy WebLinkAbout169 Brookfield Street (15)DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT TOWN OF SOUTH WINDSOR PERMIT# Application is hereby: BUILDING DEPARTMENT 0 3 APPRO 1540 SULLIVAN AVENUE Bldg.Permit# 06 V 644-2511 ext. 23 0 c L-13 1 1 Date Building Inspector Application must be printed or typed FEE SCHEDULE Location ofJob: QQ G 9cfr 0-$1,000=$13.00 Street No. Street Lot No. Over$1,000= 13.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT /,r, ,C,S-PQ-o rlvc. APPLICANT ADDRESS 4;D Wr st APPLICANT PHONE# Y 70.9 70a 0001111 0W N $E• OWNER 0J.y q OWNER ADDRESS de00k1, sS OWNER PHONE Gyy- 07S-l C ESTIMATED COST$ 8 d.ors IS THIS A CONTRACT COST? ,d Yes O No CJ FEE ENCLOSED$ 3. TYPE OF JOB: sOR O CO WNew Installation 13 Alteration/Addition/Repair Revised 8/99 APPLICATION FOR HVAC PERMIT (Continued from reverse side TYPE OF SYSTEM: TYPE OF UILDING: XREATING A RESIDENTIAL A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. 8f HYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ` ADDITIONAL RADIATION 2-< TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT LOSS(BTUH)g °F(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) L at— 3 ! . k DESCRIBE ALL HEATING EQUIPMENT(INCLUDIN/G MAKE&MODEL NO.). 1,2,/ J/.)/1 Bh' J] L/, GROSS HEATING CAPACITY(INPUT—BTUH) NET RATING(OUTPUT—BTUH) S C`3"' TYPE OF FUEL OIL—GPM OIL TANK LOCATION:INSIDE OUTSIDE CAPACITY 2fGAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE OF DIFFERENCE OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO.) TONNAGE COOLING CAPACITY(BTUH) VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. 5-/ 3gsG 6 y CONTRACTORS LICENSE NO. TYPE STATE SIGNATURE OF APPLICANT DATE RIGHT-J SHORT FORM Entire House Home tead Fuel Inc J b: 9-21-00 100 West Rd Unit II,Ellington,CT 06029 Phone:870-8700 Fax:870-7731 Project i For: Dan Taylor 169 Brookfield St,South Windsor,CT Phone:W-722-5830 Design Information Htg Clg Infiltration Outside db(°F) 0 95 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD(°F) 70 20 Fireplaces 0 Daily range M Inside humidity(%) 50 Moisture difference(gr/lb) - 11 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Effici ncy 80.0 AFUE Efficiency 0.0 EER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Low output baseboard 560 Btuh/ft Total cooling 0 Btuh Total low baseboard 24 ft Actual cooling fan 177 cfm High output baseboard 800 Btuh/ft Cooling air flow factor 0.053 cfm/Btuh Total high baseboard 17 ft Space thermostat Load sensible heat ratio 94 % ROOM NAME Area Htg load Clg load Baseboard(ft) Clg AVF ft2) Btuh) Btuh) Low High (cfm) Rec Room 432 13631 3304 24 17 177 Entire House 432 13631 3304 24 17 177 Ventilation air 0 0 Equip.@ 1.00 RSM 3304 Latent cooling 212 TOTALS 432 13631 3516 24 17 177 AWcV#Uft vahm have boon manusUy overridden Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wnghtsoft Right-Suit ResidentialTM 5.0.28 RSR27407 2000Sep-21 07:47.30 Projectl.rsr Page 1