Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
16 Green Lane (3)
DEPARTMENT DECISION APPLICATION FOR HVAC PERMIT PERMIT# Application is hereby:TOWN OF SOUTH WINDSOR BUILDING DEPARTMENT 3 APPRO 1540 SULLIVAN AVENUE Bldg.Permit# 49 L5ACI 3 644-2511 ext. 230 a G S— ate Building Inspector Application must be printed or typed FEE SCHEDULE Location of Job: e ea I,.*4e 0-$1,000=$15.00 Stre No. Street Lot No. Over$1,000= 15.00 per$1,000 or any fraction thereof Tenant Designation Apt.No. APPLICANT I,e lol APPLICANT ADDRESS / ,02 APPLICANT PHONE# CO jr OWN S OWNER Aaver 4 OWNER ADDRESS E-ZLi.C OWNER PHONE WtO 9/(w O C ESTIMATED COST$ &owe JI IS THIS A CONTRACT COST? Yes No FEE ENCLOSED$ C/U TYPE OF JO SOR-New Installation Alteration/Addition/Repair Revised 410IH2002 APPLICATION FOR HVAC PERMIT (Continued from reverse side) TYPE OF SYSTEM: TYPE OF BUILDING: HEATING RESIDENTIAL A/C COMMERCIAL VENTILATION INDUSTRIAL HEATING STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR UNIT RADIANT HEATER EXISTING RADIATION ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE F DIFFERENCE F TOTAL HEAT LOSS(BTUH) y voo OF(HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT(INCLUDING MAKE&MODEL NO.) GROSS HEATING CAPACITY(INPUT—BTUH) /r/cf6V• NET RATING(OUTPUT—BTUH) TYPE OF FUEL 14 OIL—GPM I°a OIL TANK LOCATION INSIDE OUTSIDE CAPACITY GAS—INPUT LPG TANK CAPACITY ELECTRIC—KW AIR CONDITIONING DESIGN TEMP.OUTSIDE OF INSIDE 702- OF DIFFERENCE 14 OF TOTAL HEAT GAIN(BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT(INCLUDING MAKE&MODEL NO. 01 1r° TONNAGE S-57-'COOLING CAPACITY(BTUH) 66 otD VENTILATION DESCRIBE ALL AIR HANDLING EQUIPMENT(INCLUDING KITCHEN EXHAUST EQUIPMENT) TOTAL SIZE OF SYSTEM(CFM) FRESH AIR INTAKE(CFM) PLANS MUST ACCOMPANY APPLICATION) FURTHER DESCRIPTION OF WORK THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT TO PERFORM THE WORK DESCRIBED AND IS TO COMPLY WITH ALL LOCAL ORDINANCES AND STATE OF CONNECTICUT BUILDING CODES IN THE PERFORMANCE OF SUCH WORK. r"i3 t!)5-7 8 sti--i3©sue c T` CONTRACTORS LICENSE NO. TYP STATE SIGNATURE OF APPLICANT r ' DATE 0 3 RIGHT-J LOAD AND EQUIPMEN 1 SUMMAKT Entire House Job: 10-23-02 DEBLOK HTG ALLEN ST,EAST LONGMEADOW.MA Phone:413-5254M 0/1 For:RESIDENCE LOT12GREEN LANE, SOUTH WINDSOR, CT I Notes: FIRST FLOOR Weather: Hartford,Brainard Field,CT, US Winter Design Conditions Summer Design Conditions Outside db 88 OF Outside db 6 of Inside db 75 ofInsiddb70OF Design TD 13 F Design TD 64 Daily range 50 °Relative Humid 28 gr/lbMoisturedifference Heating Summary Sensible Cooling Equipment Load Sizing Building heat loss 41134 Btuh Structure 18966 Btuh 0 cfm Ventilation 0 Btuh V ntilation air 0 Btuh Design temperature swing 3.0 OF Ventilation air loss 41134 Btuh Use mfg.data n Design heat load Rate/swing multiplier 0.93 Infiltration N l Total sens.equip.load 17639 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 460 Btuh Fireplaces Internal gains 0 BtuhVentilation2218Btuh Heating Cooling Infiltration 2678 Btuh Area(1424 1424 Total latent equip. load Volume(fe) 14160 14160 20317 Btuh Air changges/hour 1.0 0.5 Total equipment load Equiv.AVF(cfm) 236 118 Heating Equipment Summary Cooling Equipment Summary Make Make RUUD AIR COND Trade UAiCA-030JA UAKA Series RCBA-3765 10.0 SEER Efficiency 80.0 AFUE Efficiency 19740 Btuh Heating input 0 Btuh Sensible cooling 8460 Btuh Heating output. 0 Btuh Latent cooling 2 Btuh Heating temp nse 00 OF Total doling cffm Actual cooling fancfm Actual heating fan 10 0.024 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh Heating air flow factor Space thermostat Load sensible heat ratio 88 Bokftft vAM h M•been MWW8 j vvW+ftn printout certified by ACCA to meet all requirements of Manual J 7th Ed.2=.Occ 23 17:10:44 wnghtsoft RW-Suite Resident M 6.0.38 RSRRUD26W7 pop 1 Pn jedl.rsr RIGHT-J SHORT FORM Entire Hous DEBLOK HTG Job: 10-23-02 ALLEN ST,EAST LONGMEADOW,MA Phone:413a25- M Project • For: RESIDENCE LOT12GREEN LANE, SOUTH WINDSOR, CT Design Information Htg Clg Infiltration Outside db(OF) 6 88 Method Simplified Inside db(OF) 70 75 Construction quality Average Design TD('F)64 13 Fireplaces 0 Daily range M Inside humidity 50 Moisture difference(gr/lb) - 28 HEATING EQUIPMENT COOLING EQUIPMENT Mak Make RUUD AIR COND Trade Trade Ruud UAKA Series UAKA-030JA RCBA-3765 Effici ncy 80.0 AFUE Efficiency 10.0 SEER Heating input 0 Btuh Sensible cooling 19740 Btuh Heating output 0 Btuh Latent cooling 8460 Btuh Heating temperature rise 0 OF Total cooling 28200 Btuh Actual heating fan 1000 cfm Actual cooling fan 1000 cfm Heating air flow factor 0.024 cfm/Btuh Cooling air flow factor 0.053 cfm/Btuh Space thermostat Load sensible heat ratio 88 % ROOM NAME Area Htg load Clg load Htg AVF Clg AVF ftz) Btuh) Btuh) cam) Cfm) LIVING ROOM 196 5201 3003 126 158 FAMILY ROOM 256 5916 4433 144 234 FOYER 168 5550 1309 135 69 DINING ROOM 196 5201 2013 126 106 KITCH/DINE 272 8368 2054 203 108 LAUNDRY/BATH 192 4801 3831 117 202 DEN 144 6097 2324 148 123 Entire House d 1424 41134 18966 1000 1000 V ntilation air 0 0 Equip. a@ 0.93 RSM 17639 Latent cooling 2678 TOTALS 1424 41134 20317 1000 1000 BokV aft vskm havebeen nnnuaW ovwrkMm Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wnghtsoft RlgN-Suite R"dentf -5.0.38 RSRRUD26387 2002-Oct 2317:10:44 m Projedinr Page 1 RIGHT-J SHORT FORM Entire House DEBLOK HTG/COOL Job: 10-23-02 ALLEN ST,EAST LONGMEADOW,MA Phone:413-525-SBW Project • For: RESIDENCE LOT IZ GREEN LANE, SOUTH WINDSOR, CT Design Information Htg Clg Infiltration Outside db(OF) 6 88 Method Simplified Inside db(OF) 70 75 Construction quality Average Design TD(OF)64 13 Fireplaces 0 Daily range M Inside humidity(%) 50 Moisture difference(gr/lb) - 28 HEATING EQUIPMENT COOLING EQUIPMENT Make RUUD AIR COND Make RUUD AIR COND Trade Ruud Trade Ruud UAKA Series UGRA-04(E,N)MAES UAKA-030JA RCAH-Z037 Efficiency 93.5 AFUE Efficiency 10.0 SEER Heating input 45000 Btuh Sensible cooling 19320 Btuh Heating output 42000 Btuh Latent cooling 8280 Btuh Heating temperature rise 38 OF Total cooling 27600 Btuh Actual heating fan 1000 cfm Actual cooling fan 1000 cfm Heating air flow factor 0.034 cfm/Btuh Cooling air flow factor 0.055 cfm/Btuh Space thermostat Load sensible heat ratio 84 % ROOM NAME Area Htg load Clg load Htg AVF Clg AVF ft2) Btuh) Btuh) cfm) cfm) MASTER BEDROOM 234 6985 5200 241 286 MAST BATH/WIC 252 4196 1221 145 67 BEDROOM 2 FRONT 196 4700 3787 162 208 BEDROOM 2 REAR 168 4919 2013 170 111 BATH UP 112 1483 444 51 24 BEDROOM 4 322 6732 5510 232 303 Entire House d 1284 29014 18176 1000 1000 Ventilation air 0 0 Equip. @ 0.93 RSM 16903 Latent cooling 3449 TOTALS 1284 29014 20353 1000 1000 R-Oldlitaiic vaitie-s have hewn manuwiy nvama en Printout certified by ACCA to meet all requirements of Manual J 7ih Ed. wrightsoft Right-Sude Residentiailm 5.0.38 RSRRUD25381 2002-Oct-23 17'41.09 COCA -. ._. 1