Loading...
HomeMy WebLinkAbout154 Commerce Way (3)F'iAAL INSPISC WNS: Building c APPLICATION FOR BUILDING PERMIT Plumbing aA< Pvri kler 154 COMMERCE WAY Date: S'U S El ctric - Estimated Costs 2 00 0 Zoning 18276 Permit Fee$ I J; o Affidavit NO.Occupancy Fee 3 Eng. Dept. y Fire Dept. COMPLETE RED BOXED AREAS. Total Fee $ 2.12 3 Health Deat. TYPE OR PRINT ONLY Approved for CO: SIGN ON REVERSE SIDE. Additional Cost) $ Stx TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Location C-Mcft Lot No. Side of Street S167one Applicant JF*1 tATMS- !NG_ Tel. #AA9--7=962 Address 7ff Ct2A4MV2CA Y AY0 5L IVitlt)g0x G'"Zip ^7 ,, Lic.# STREET CITY STATE Owner JF( A.ssoal-Azr .5, JAW. Address '7. COMMKOW-lC N&4 f 514, Q-T-01 o '& Architect&M A5sar-MdT, 1W.-Address VE COMMA ff WAW, 4,W .G O066714- Size New Area: Ft. Front Overall&Ft. Deep Overall 190' Total Area Garages O Lavatories No. of Families o No. of Stories Construction 2G Bathrooms ---• Rooms 1st - 2nd — 3rd Size of Lot .46 -Dist. from Street Line 7' Dist. from Side Street Line Purpose of this Permit _S _,&xr_ ¢ucTraAl C A AJEW XV STAUAQ-?'-14,t.r FS- t l T V- el e s- ciro'l o City Water Well Septic 0 Sewer Approved by Date BD1A 11/88 I hereby agree to conform to all the requirements of th Laws of th State of Connecticut and the Ordinances of the Town of South Windsor. and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lin s,side yard lines and required distanc s from all oth r zones and is located in a zone in which this building and its use is allowed. p Si ned c, I hereby apply for a Certificate of Occupancy for the work described in this application for permit. Signed DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation - --3` Plumbing Permit# /s7 r D Inspections: U•6. 23 6 J Qr Cq 90 cfi HVAC Permit# Inspections: d1l19l,qd sAAIE Electrical Permit# Inspections: 0 b/L- g2Et-C l N Sprinkler Permit# Inspections: Location of job AFFIDAVIT Additional Fee . . . 40 State of Connecticut County of Hartford ss. IAA y 1 ' x rNd6-cr-OwnerI .. ... ... . . .. .. .. . . ... . .. . . ... . ... . . ... .. . . . .. . . .. .of ?S. c:.aN .oC.. I Agent for building erected under ontracM-N Permit Na . . .. .... . .. . . . ... . .. . .... .. issued by the Dept of Building of the Zbwn of South Windsor being duly sworn,make oath and say that the actual cost of the completed work authorized under said permit was... . . . Signe Subscribed and sworn to before me this .... .. ..02.2 day of ... . .. . . A.D.191.P. Estimate Cost:$ e257/ b Difference: $ T lS6 Notary Public. 1& 1'1 1`-IrfA BUILDING INSPECTION DEPARTMENT SOUTH WINDSOR; CONNECTICUT FEE- PAID: $3.00 CERTIFICATE OF OCCUPANCY i ZONE: I DATED May 22 19 9 0 1 1 This is to ce that 154 C-46 m eece way FrQ.steA under permit No. 1 conforms substantially to the requirements of the building ordinances and the zoning regulations of the Town of South findsor4W is hereby approved for occupancy as indicated below. F pproved for Occupancy— New distuibution facility Use Grpup:S_1 1 Conant. Type: 2_c Building Officiali Notice:ff th4tefocatis is 4t or destroyed, a duplicate should be obtained Ohmedlately from the Building Department. Any&hangs'fir extension of the use herilda approved> rres a new cerfhkate of occupancy. I CERTIFICATE OF OCkk',Ui ANL;i i:r,:__. LIST WJIP s- Gaowy Applicant JFI ASSOCIATES Certificate of Occupancy AOL S feloAddressBldg. Permit No. 07 bLotNo. Date Submitted 17-90Project154CommerceWayReviewedBy Date As required in the Zoning Regulations, no certificate-of-occupancyshallbeissueduntilgradingplanshavebeencompliedwithandapprovedbytheTownEngineer. The minimum requirements shallinclude: Approved Denied N/A 1. Approved building permit plan. 2. Finish grading per approved building permit plan. 3. Site work; i.e. trees, shrubs, dumpsters ,required parking 4. Utility location a. sanitary sewer b. foundation drain c. electrical & telephone d. water e. other S . Appropriate certification 6. Bonding Sewer Permit No. Pavement Excay. No. COMMENTS: Z; I 1 y PERMIT DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby: TOWN OF SOUTH WINDSOR APPROVEDISAPPROVED BUILDING INSPECTION DEPT. 644-2511 Ext. 2302L Application must be oprintedatBuildingInspectorP r typed . 1. LOCATION OF JOB FEE SCHEDULE No . Street 0 - $12000 - 10. 00 Floor Apt . No. Over $1,000 - 10.00 per $1,000 or 2 . OWNER fraction thereof 3. ADDRESS t 4. APPLICANTp,; E4c w, 5 . ADDRESS Iq ?, j 6. ESTIMATED COST $ as 000_, ob 7 . IS THIS A CONTRACT COST - Yes No _ 8. FEE ENCLOSED AqR6 .O r/R 769. TYPE OF BUILDING: RESIDENTIAL COMMERCIAL 10. TYPE OF JOB : Original Installation Alteration/Addition/Repair BD 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11 . LOCATION OF J O B [ S_-( NO. STREET APT. NO 12 . TYPE OF INSTALLATIONS y 3V, 13 . SIZE OF MAIN FEEDER S-C) yy\e w-\ A tv qv-\ 14 . NO. OF LIGHT LOOPS )d 15 . NO. OF HEAT LOOPS 16. NO. OF POWER LOOPS c;'- 17 . NO. OF LIGHT OUTLETS 18 . NO . OF HEAT CIRCUITS c)- 19. NO. OF POWER OUTLETS 20. NO. OF CONVENIENCE OUTLETS 3 21. NO. OF HEAT CIRCUITS 22 . NO. OF POWER CIRCUITS 10 23 . NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS 26 . NO. OF PANELS 1 27 . TOTAL WATTAGE 28 . NO. OF POWER FEEDERS 29 . NO. OF SWITCHES 30. A/C LOAD 31. SIZE OF POWER FEEDERS 32 . NO. OF FIXTURES L' 33 . TOTAL HORSEPOWER 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : O-c vN 2 LICENSE NO.SIGNATURE OF APPLICANT DATE PHONE NUMBER:c CS (— l C Lot'No, 3 7 3 Building Permit / J 7 Terfffilaft emporary Servic Permanent Service j Pursuant to Permit No. P..2/S This Certifies that the Electrical Work for which the above named Permit was granted has been duly inspected and is hereby approved. Owner Electrician_ Street-1 2 k 19-S Building Inspector Building Permit /8.;L 7 6 fierfifticatt Temporary Service a-ne nfServic Pursuant to Permit No. t This Certifies that the Electrical Work for which the above named Permit was grantedhasbeendulyinspectedandisherebyapproved. Owner- Assoc Electrician_Do(t .S Oe I Street kx-r t Building Inspector tow" Sf-4 r 710 ale si d&U&ot 1540 SULLIVAN AVENUE • SOUTH WINDSOR, CONN. 06074 OR-co AREA CODE 203/644-2511 MEMORANDUM TO: George Spring, Director of Finance FROM: John R. Collins, Chief Building Official DATE: June 27, 1990 SUBJECT: Refunds for two plumbing permits Please process a refund for the two enclosed Plumbing Permits . The work was covered under a prior permit. (See enclosed letter. ) low MFC1gAN/CA1 8FAVICESf /NC. AIR CONDITIONING• REFRIGERATION • HEATING 54 CODY STREET•WEST HARTFORD,CONNECTICUT 06110 TEL (203)249-1617 June 11, 1990 Mr. Collins Town of South Windsor Building Department 1540 Sullivan Avenue South Windsor, CT. 06074 Dear Mr. Collins: At your request this letter is to inform you that on the jobs at Metal Testing on Kimberly Lane and the Hoyt Building on 154 Commerce Way the gas piping was done by W.C. Brescia Plumbing & heating, Inc. , who was a sub- contractor of Aire Tech Mechanical Services, Inc. Originally Aire Tech took the permit out which included the gas piping. If you have any further questions, please don't hesitate to call. S' cerely, m e s 4oce President JL:co PERMIT NO. Q A DEPARTMENT DECISION APPL I CAT I O N FOR Application is hereby : PLUMBING PERMIT TOWM OF SOUTH WINDSORAPPROVEDDISAPPROVEDBUILDINGINSPECTIONDEPT. 644-2511 Ext. 230 Date 1171 ding Inspector Application must be printed or typed. 1. LOCATION OF JOB: 6 2/ Co MIm CZ't-c wA- FEE SCHEDULE 2. OWNER: Z317L /9 S50C/47-& 0 - $1,000 - 10.00 3. ADDRESS: 9 ?-h M,z C_ Over $1 ,000 - - $10.00 OSon' per $19000 or fraction thereof 4. APPLICANT: ,(J.0 .QitteSCf, P V-f t6.G 5. ADDRESS: lgcusre.--Sr PO• 13 DX joa 7--- c,v s7- 4-htrL o CE 6. EST. COST: $ ,(000,O0 T 7. IS THIS A CONTRACT COST? 41 YES NO 8. FEE ENCLOSED: $ .2 OO I,Z76 9. TYPE OF BUILDING: RESIDENTIAL y COMMERCIAL 10. TYPE OF tJOBB: y ORIGINAL ALTERATION INSTALLATION ADDITION REPAIR r BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: Coat mow",-co WJI-ty GENERAL PLUMBING 12. KIND OF INSTALLATION: llljd ec 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS STYLE 15. NO. OF URINALS STYLE 16. NO. OF BATHTUBS 16A.. NO. OF SHOWERS 17. NO. OF LAVATORIES 18. NO. OF SINKS 19. DISPOSAL 19A. DISWASHER 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACKS SIZE 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS 32. REMARKS AND FURTHER DETAILS 7-0 All 1AIA C WATER HEATER 33. TYPE 34. MANUFACTURER TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE LBS. 40. MANUFACTURER 37. WORKING PRESSURE LBS,. 41. PRESSURE RELIEF VALVE 38. TYPE 42. MANUFACTURER LICENSE NO. DATE SIGNATURE OF APPLICANT PHONE NO. o U3 ' gJT-7-2' PERMIT NO. DEPARTMENT DECISION APPLI CAT ION FOR Application is hereby: PLUMBING PERMIT TOWM OF SOUTH WINDSORAPPROVEDDISAPPROVEDBUILDINGINSPECTIONDEPT. 644-2511 Ext. 230 Date B ing Inspector Application must be printed or typed. 1. LOCATION OF JOB: x.rel e c Lr FEE SCHEDULE T2. OWNER: -- _r 3. ADDRESS:0 - $19 000 -10.00 Over $1 ,000 - 10.00 D607ei per $1 ,000 or 4. APPLICANT:fraction thereof 5. ADDRESS: 6. EST. COST: $ '"p,v 7. IS THIS A CONTRACT COST? DYES NO 8. FEE ENCLOSED: $ r"/ 7 9. TYPE OF BUILDING: RESIDENTIAL COMMERCIAL 10. TYPE OF JOB: O ORIGINAL ALTERATION INSTALLATION ADDITION REPAIR BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: oxr 6924 y GENERAL PLUMBING 12. KIND OF INSTALLATION: « ( 13. SIZE OF MAIN DRAIN 14. NO. OF TOILETS STYLE 15. NO. OF URINALS p STYLE 16. NO. OF BATHTUBS Q 16A. NO. OF SHOWERS 0 17. NO. OF LAVATORIES 18. NO. OF SINKS 0 19. DISPOSAL () 19A. DISWASHER 0 20. NO. OF CONDUCTORS SIZE 21. NO. OF STACK SIZE j e` 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES -- KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS Y `'30. SEWER OR SEPTIC TANK? fc /C 31. SIZE OF WATER MAIN 31A. SIZES OF WATER PIPING & RISERS 32. REMARKS AND FURTHER DETAILSoo,r1 r L1/tiC Ur. b.,. . L ,t/[ . o v de WATER HEATER 33. TYPE G 34. MANUFACTURER 5,L-; TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY G .`/p,f 39. RELIEF VALVE 20 O 36. TEST PRESSURE J LBS. 40. MANUFACTURER W1 zr'S 37. WORKING PRESSURE y LBS. 41. PRESSURE RELIEF VALVE /fp 38. TYPE L?1ls 4-7 el 42. MANUFACTURER LICENSE NO. DATE I AT E OF,.P&PLIC ' PHONE NO. 4 r....x. 9 WSx ._, my A PLICA'TIM POR HVAC POWIT DATEirNO.y4b A TOW OF SOUTH WINDSOR EST. ST.:`BLDG. PERMIT NO. 1540 SULLIVAN AVENUE FEE SOUTH W=S,0R 0 $1,0Q0 - $10.00644-+2911 - Ext. 230 1000 or f*action LOCATION OF BUILD NG thereof - $10.00 ER ADDRESS`- TOWN PHONE NO. ALC CONTFACT R ADDRESS TOWN ONE NO. TYPE OF SYSTEM: HEATING r/ TYPE OF BUILDING: RESIDENTIAL A/C COMMERCIAL -Ll VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS.HYDRONIC WARM AIR UNIT RADIANT HEATER (INCLUDING WOOD COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW WOOD COAL o v OIL TANK - SIZE & LOCATION INSIDE OUTSIDE CAPACITY LPG TANK - CAPACITY_ EXISTING RADIATION ADDITIONAL RADIATION_ TOTAL RADIATION DESIGN TEMP. OUTSIDE OF INSIDE F DIFFERENCE TOTAL HEAT LOSS (BTUH) HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): 4- ge-a t vet GROSS HEATING CAPACITY (INPUT-BTUH) NET RATING (OUTPUT-BTUH) IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE 2 C °F INSIDE 7 22F DIFFERENCE FTOTALHEATGAIN (BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING EQUIPMENT (INCLUDING MAKE & MODEL NO.): t/ TONNAGE COOLING CAPACITY (BTUH) IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT): TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to complywithalllocalordinancesandStateofConn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: rzZ2E-Lf a d,),/5_ ®ill l 0 3—Z 6 STATE LICENSE - NAME & TYPE #DATE SIGNATU 0APPLICANT APPROVED DATE BD 4A 11/88 I - B a R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by The Hydronlcs Institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL.A COL.B COL.C COL.D COL.E COL.F COL.G 1 ROOM O H L W H L IN H L W H L W H I L W Design Water Temp. 2 ROOM DIMENSIONS,FT.V OTUH per F t of 3 LENGTH EXPOSED WALLS,FT. Radiation Selected WINDOW AND OUTSIDE DOOR AREA IL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION ROOM LIN. FT,OF Table 9,Line 3 x H) TOTALS RADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED Bottom of table used for Line 5) 4 7 CEILING CONSTRUCTION C Table 9, L x W) D g FLOOR CONSTRUCTIONt Table 9, L x W r Lin. Ft.) E 9 COLD PARTITION CONSTRUCTION F Table 9, L x H)G 10 c 1 Wall(With Openings) 11 o e;2 Wells(With Openings) J 3 Walls(With Openings or Ent.Hall Ie 1 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE K COL.A COL.B COL.H COL. I COL.J COL.K COL.L TOTAL BTUH TOTAL OF BUILDING RADIATION 3'LENGTH ROOM AT SELECTED O H L W H L W H L W H L W H L W DESIGN TEMP.° ROOM DIMENSIONS, FT f' DIFFERENCE U EXPOSED WALLS, FT. d 41 WINDOW AND OUTSIDE DOOR AREA LL BTUH BTUH BTUH BTUH BTUH 5 WALL CONSTRUCTION INCREASE BATHROOM Table 9, Line 3 x H) TOTAL 20% 6 TYPE OF GLASS Bottom of table used for Line 51 tFOR CONCRETE FLOOR ON 7 CEILING CONSTRUCTION GROUND OR FILL AT Table 9,L x W) GRADE LEVEL,USE LINEAR g FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE Table 9,L x W r Lin Ft.) 9 COLD PARTITION CONSTRUCTION Table 9,L x H) 10 _c 1 Wall(With Openings) i 2 Walls(With Openings) 2 X J 3 Wells IWlth Openings) or Ent.Hall Fe- 11 TOTAL BTUH AT 70F TEMP. DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP. DIFFERENCE FORM 1503 This form Is available fr m The Hydronics Institute,35 Russo Place,Berkeley Heights,N.J. 07922 STANDARD LOAD OUTPUTS Company Name: AIRE TECH MECHANICAL INC 03-26-90 Block Load v1 .0 Page 1 of 2 Zone Name: 154 COMMER. WAY City Name HARTFORD, CONNECTICUT Weight - Wall : 70 Latitude (deg) : 42 lb/sqft) Roof: 40 Elevation ( ft ) : 15 Bldg: 70 Indoor -Summer: 72 F 50 RH Color - Wall: MEDIUM Winter: 75 F Roof: MEDIUM TEMP TOTAL TONS RSH TONS CFM 1 . JUN at 9 A.M. 75 . 6 1 . 68 1 . 11 714 2 . JUL at 9 A.M. 78. 6 2 .00 1 . 26 808 3 . SEP at 10 A.M. 75 .4 2 . 76 1 . 90 19219 4 . OCT at 2 P.M. 74 .0 2 .81 2 .04 19311 5 . SEP at 3 P.M. 85 .4 3 . 01 1 . 91 19226 6. JUL at 4 P.M. 90.0 2 . 32 1 . 36 870 7 . JUN at 4 P.M. 87 .0 2 .02 1 . 24 795 Heating Load (Btuh)= 199726 w/Infil . = 199726 Airflow=512 cfm ORIENTATION OF BUILDING N S E W RF TRANSMISSION FACTORS 0.08 0. 08 0.08 0. 08 0. 08 Glass Fac. :0. 55 Lights Fluorescent? Y Shade Fac. :0. 63 Floors: 1 Length: 40 Width: 12 Height: 9 Vent Air Percent: 20 Number of people = 3 Sensible people load = 735 Total lights 19440 Lighting load 69143 Other electrical = 240 Other electrical 819 Area of N glass = 0 North glass solar 0 Area of S glass = 196 South glass solar 129283 Area of E glass = 0 East glass solar 0 Area of W glass = 0 West glass solar 0 Total glass area = 196 Total glass solar 129283 Total glass trans. =19445 Area of N wall = 360 N wall load 120 Area of S wall = 164 S wall load 390 Area of E wall = 108 E wall load 84 Area of W wall = 108 W wall load 96 Total wall area = 740 Total wall trans. 690 Area of roof 480 Roof load 805 Safety factor 0% Safety load 0 Supply fan hp 1 .05 Fan heat gain (DT) =3 , 228 Ventilation cfm = 245 Vent sensible load =3 , 613 Vent latent load 59714 People latent load = 615 Total cfm-std air= 19226 Total latent load 69329 Room sensible 229920 Room latent 615 Plenum return exhaust credit =0 GRAND TOTAL LOAD =36 ,091 Btu/hr or 3 .01 tons <-- Load run for # 5 . SEP at 3 P.M. Area (sq ft ) 480 Sq ft/ton 160 Total cfm-std air= 19226 Cfm/sq ft 2 . 55 HEATING LOAD Ventilation load = 19,415 Roof heating load 29765 Glass heat load = 79762 Wall heating load 49262 Infiltration load= 0 Warm-up load 0 Slab heating load= 4 , 937 Heat load with vent = 399140 STANDARD LOAD OUTPUTS Company Name: AIRE TECH MECHANICAL INC 03-26-90 Block Load v1 .0 Page 2 of 2 Zone Name: 154 COMMER. WAY COIL SELECTION PARAMETERS Coil temp enter = 74 . 7/ 62 . 3 Total sensible load = 299762 Coil temp out 52 . 6/ 52 .0 Total coil load 369091 Specified room RH= 50% Resulting room RH 49% Terminal air temp=55 .0/110.0 Degrees rotated 0 Supply fan static= 3 .00 No ceiling return Building U-factor= 0 . 15 watts STANDARD LOAD OUTPUTS Company Name: AIRE TECH MECHANICAL INC 03-26-90 Block Load v1 .0 Page 1 of 2 Zone Name: 154 COMMER. WAY City Name HARTFORD, CONNECTICUT Weight - Wall : 70 Latitude (deg) : 42 lb/sqft ) Roof: 40 Elevation ( ft ) : 15 Bldg: 70 Indoor -Summer: 72 F 50 RH Color - Wall : MEDIUM Winter: 75 F Roof: MEDIUM TEMP TOTAL TONS RSH TONS CFM 1 . JUN at 9 A.M. 75 . 6 3 .89- 2 . 62 19679 2 . JUL at 9 A.M. 78 . 6 4 . 32 2 . 76 19768 3 . SEP at 10 A.M. 75 .4 4 . 15 2 .87 19839 4. OCT at 2 P.M. 74 . 0 3 . 69 2 . 69 19727 5 . SEP at 3 P.M. 85 .4 4 .84 3 .09 19984 6 . JUL at 4 P.M. 90 .0 5 . 14 3 . 03 19944 7 . JUN at 4 P.M. 87.0 4 . 68 2 . 91 11868 Heating Load (Btuh)= 309053 w/Infil . = 309053 Airflow=781 cfm ORIENTATION OF BUILDING N S E W RF TRANSMISSION FACTORS 0.08 0.08 0.08 0.08 0.08 Glass Fac . :0. 55 Lights Fluorescent? Y Shade Fac. :0. 63 Floors: 1 Length: 39 Width: 25 Height: 9 Vent Air Percent: 20 Number of people = 3 Sensible people load = 735 Total lights 21925 Lighting load 129479 Other electrical = 488 Other electrical 1 ,664 Area of N glass = 0 North glass solar 0 Area of S glass = 126 South glass solar 29772 Area of E glass = 105 East glass solar 19956 Area of W glass = 105 West glass solar 99581 Total glass area = 336 Total glass solar 149308 Total glass trans. =3 , 326 Area of N wall = 351 N wall load 323 Area of S wall = 225 S wall load 440 Area of E wall = 120 E wall load 148 Area of W wall = 120 W wall load 215 Total wall area = 816 Total wall trans. 19126 Area of roof 975 Roof load 29722 Safety factor 0% Safety load 0 Supply fan hp 1 . 67 Fan heat gain (DT) =59121 Ventilation cfm = 389 Vent sensible load =79700 Vent latent load 119851 People latent load = 615 Total cfm-std air= 19944 Total latent load 129466 Room sensible 369361 Room latent 615 Plenum return exhaust credit =0 GRAND TOTAL LOAD =61 , 648 Btu/hr or 5. 14 tons <-- Load run for # 6. JUL at 4 P.M. Area ( sq ft ) 975 Sq ft/ton 190 Total cfm-std air= 19944 Cfm/sq ft 1 . 99 HEATING LOAD Ventilation load = 30,800 Roof heating load 59616 Glass heat load = 139306 Wall heating load 41700 Infiltration load= 0 Warm-up load 0 Slab heating load= 69431 Heat load with vent = 60 ,853 STANDARD LOAD OUTPUTS Company Name: AIRE TECH MECHANICAL INC 03-26-90 Block Load v1 .0 Page 2 of 2 Zone Name: 154 COMMER. WAY COIL SELECTION PARAMETERS Coil temp enter = 75 . 6/ 63 .0 Total sensible load = 49, 183 Coil temp out 52 . 6/ 51 . 9 Total coil load 61 , 648 Specified room RH= 50% Resulting room RH 48% Terminal air temp=55 . 0/110. 0 Degrees rotated 0 Supply fan static= 3 .00 No ceiling return Building U-factor= 0. 15 watts