Loading...
HomeMy WebLinkAbout153 Clark Street (2)Decwic# /q©S$ APPLICATION FOR BUILDING PERMIT Plumbing# TY66 153 CLARK STREET HVAC # S 23112 Date: Sprinkler# NO' FINAL APPROVALS Estimated Cost $ Oo C, Building 1 z/54 19(o 414 COMPLETE RED BOXED AREAS Permit Fee 0 U Engineering iI LT 94 TYPE OR PRINT ONLY Occupancy Fee $3 Affidavit 17 SIGN ON REVERSE SIDE Appr.for CO. / Total Fee 901 TO BUILDINGIDPARTMENT,TOWN OF SOUTH WINDSOR,CT Additional Cost l 1 2? Th and rsigned hereby applies to do work according to the following specifications: Job Location / No. Side of Street Zone Applicant Tel.#840 ,5 6 9-11 W Address a guy,Q P„ L,' Zip 0611A, Lic.# Own r f f Address Architect vS -",,2 rT_Address737,&y,atle- Sq. Ft.New Area: 1st A. 2nd FI. 3rd FI. Total New Area Rooms & Lavatories Bathrooms Garages C2 Purpos of this permit: iS/L /1u .®m loe'&/ Z2"Iz City Water 21 Well k Septic System 0 Sewer R Use Group Construction Type Area Basem nt 25SL Garage Approved by Date .5— /CA6 Revised 6/95 I hereby agree to conform to all the requirements of the Laws of the State of Connecticut and the Ordinances of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this budding is to b11ated the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a in wh'c this buil =usisd. Signed_._ I hereby apply for a Certificate of Occupancy for he work described in this application for the permit Signed DO N RITE BELOW THI E -- INSPECTION COMMENTS Location of Job AFFIDAVIT Additional Fee$ 4 5 0. 0 0 State of Connecticut ss.South Windsor County of Hartford Owner Of t for the building erected I Contractor 23112 issued by the Building Department of the Town of South Windsor being under Permit No. ddulysworn,make oath and say that the actual cost of the completed work nut exceed the most current accepted BOCA value of S i Si ed day of A.D.19 Subcribed and sworn to before me this Estimated Cost$1 n l Q n n_ 0 0 Difference: $ 4 4 3 2 7 . 0 0 No Pu lic r c Inspection / Approval Date By Appl Code Description Due Whom Code Comment 96-23112-B 90,000 BO1 FOOTING 06/27/96 JFH D TOO MUCH MUCK BO1 FOOTING 06/27/96 JFH A OK PM B02 FOUNDATION 07/11/96 JFF A B05 FIREPLACE/CHIMNEY 08/29/96 JFF A E01 SERVICE 09/05/96 JFF A RELEASED B03 FRAMING (ROUGH) 10/11/96 JFH A P03 ROUGH 10/11/96 JFH A E03 ROUGH 10/15/96 JFH D PADDLE FAN BOXES/NO ATTIC LIGHT E03 ROUGH 10/21/96 JFH A GARAGE B04 INSULATION 10/23/96 JFF A BO1 FOOTING 11/21/96 JFH A DECK PEIRS B10 FINAL 12/10/96 JFH A APPROVED FOR CO & CLOSEOUT 96-9806-P 5,000 96-9566-H 7,000 96-14088-E 3,800 Total Est Value 105,800 Dwelling 2,326 95,179.92 Basement 2,356 29,214.40 Garage 640 7,936.00 Smoke Det 7 525.00 BOCA Value 150,126.51 Difference 44,326.51 1 r SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT 153 CLARK STREET LOT_#01 Reviewed By En ineering)NADOLNY STANLEY & CYNTHIA Date Reviewed rove )YDenied69SAWKAD,EAST HARTFORD,CT Reviewed By Planning) ' -BP #_23112_ Ph_#_(860)569-1190 Date Reviewe pprove DeniedDateSubmitted11/07/96 FOR C o O **** As required in the Zoning and/or Subdivison Regulations, no Certificate of Occupancy shall be issued until grading plans have been complied with and approved by the Town Engineer. The minimum requirements shall include: Approved Denied N/A 1. Approved building permit plan 2. Finish grading per approved building permit plan 3. Site work; i.e. trees, shrubs, dumpsters, required parking 4. Utility location; a. sanitary sewer/septic system b. foundation drain C. electrical & telephone r d. water e. other 5. Sewer connection charge paid 6. Appropriate certification 7. Bonding 8. Planning & Zoning/ Inland Wetlands Considerations Sewer Permit No. Gq570 Pavement Excavation No. COMMENTS: s Q RECEIVt NOV 7 1996 , SITE COMPLIANCE CHECKLIST TOWN of SOUTH WINDSOR, CONNECTICUT v 153 CLARK STREET LOT #01 R viewed By a-Engineering) J NADOLNY STANLEY & CYNTHIA Date Reviewed pp v 69 SAWKAD,EAST HARTFORD,CT Reviewed By Planning) BP_# 23112_ Ph # (860)569-1190 Date Revi t pp v Denied Date Submitted 04/25/96 FOR IL NG PE In accordance with the Zoning and/or Subdivision Regulations, prior to the building of any structure on a lot, a Topographic Plot Plan shall be submitted for approval. The minimum requirements shall include: Approv Denied N/A 1-1-11 1. Name, adder= & phone number of owner/applicant6 2. Name, address & phone number of plan preparer jA- 3. Zoning Information - i.e. zone, open space, floodway, etc. 4. Plot Plan at 1" = 40' scale a. Subdivision reference, abutting properties, etc. c-' b. Easements of record c. Lot description, bearings, building lines, distances, area, etc. d. Contours, existing & proposed, 1 or 2 ft. -- J •%-,y - interval where appropriate r e-.G e. Building location with dimensions. Q'c %--.P o- e...o Eleva -j as of proposed finish floor, garage floor & centerline of road at driveway f. Elevations of gravity drainage systems, sanitary o47 r r .ss•"'00' foundation drain at the house and the street r y d C r 2i dw .Strrfii ier / i. w/N / J.g. Tentative utility location (gas, water, electric, septic system, etc.) h. Title block with name and address of preparer, date, appropriate certification, live seal and live signature consistent with the Board of Registration requirements. (P.E. & L.S.) Aft S. Sedimentation and erosion control 6. Special Planning & Zoning, Inland/Wetlands 61 considerations (Plans on file w/Town Clerk) t l7 pa A COMMENTS: 107 Selden Street,Berlin,CT 06037Northeast pgN U ' ties System Northeast Utilities Service CompanylP.O.Box 270 Hartford,CT 06141-0270 860)665-5000 April 22,1996 South Windsor Town Hall 1540 Sullivan Avenue South windsor,Connecticut 06074 ATTN: Mr.John Collins Building Inspector Dear Mr. Collins: Enclosed is a map from Stanley Nadelny,showing the location ofa proposed driveway at the propertylocatedoffClarkStreet,South Windsor,Connecticut. The Connecticut Light and Power Company has no objections to Mr.Nadelny,or his contractors building a driveway at the location shown on the attached Exhibit"A" Sincerely, Joanne Simon Real Estate Agent jms Enc. OS3422 REV.8-95 Ll o I U I 33pot WA NZI v t J 53 cza," Northeast 107 Selden Street,Berlin,CT 06037 U ' 'ties System y Northeast Utilities Service Company P.O.Boa 270 10, Hartford,CT 06141-0270 WQe6t;5-860)665-5000 April 22,1996 South Windsor Town Hall 1540 Sullivan Avenue South Windsor,Connecticut 06074 ATTN: Mr. John Collins Building Inspector Dear Mr.Collins: Enclosed is a map from Stanley Nadelny,showing the location of a proposed driveway at the property located off Clark Street,South Windsor,Connecticut. The Connecticut Light and Power Company has no objections to Mr.Nadelny,or his contractors building a driveway at the location shown on the attached Exhibit"A" Sincerely, Joanne Simon Real Estate Agent jms Enc. OS3422 REV.8-95 as 7 w N i I01: IN • . j PERMIT a DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT gg Application is hereby : TOWN OF SOUTH WINDSOR BUILDING INSPECTION DEPT.APPROVED DISAPPROVED 1540 SULLIVAN AVENUE 1,rA6 644-2511 Ext . 230 ate ing Spector Application must be printed or typed 1 . LOCATION OF JOB FEE SCIIEDULE No . Street 14 Z*e 0 - $1.000 - 10.00 Floor Apt . No. Over $1 ,000 - 10.00 per $10000 or 2 . OWNER ho rY? A fraction thereof sm3, ADDRESS aX4, 4 . APPLICANT e r S. ADDRESS 6. ESTIMATED COST 7 . IS THIS A CONTRACT COST Y 8. FEE ENCLOSED $ 9. TYPE OF BUILDING: 4IRESIDENTIAL COMMERCIAL 10. TYPE OF JOB : 9—Original Installation Alteration/Addition/Repair R8 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side) 11 . LOCATION OF JOB XJD c NO. STREET APT. NO . 12 . TYPE OF INSTALLATION pcn5,eP- 13 . SIZE OF MAIN FEEDER I d 14 . NO . OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS 16 . NO . OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS 18 . NO . OF HEAT CIRCUITS Imo_ 19. NO. OF POWER OUTLETS /a 20 . NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS 22 . NO. OF POWER CIRCUITS 23. NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS ^ 25 . NO. OF MOTORS 26 . NO . OF PANELS c 27 . TOTAL WATTAGE 28 . NO . OF POWER FEEDERS 29 . NO. OF SWITCHES 30. A/C LOAD A 2?/d 31. SIZE OF POWER FEEDERS 32. NO. OF FIXTURES /v 33. TOTAL HORSEPOWER 34. NAME OF SUBCONTRACTORS AND THEIR TRADES yG !i 35 . REMARKS AND FURTHER DETAILS : U l Z G'—`— i==H ice r S- AJ 9 1,0 LICENSE NO.SIGN TURE OF APP CANT DATE PHONE NUMBER: INSPECTOR DATE // TIME LOCATION INSPECTION: CODE: RESULT(D/A) : BUILDING: 11z ELECTRICAL: m V PLUMBING: v HVAC: OTHER: Z7 PERMIT NO. 4Tft 7 DEPARTMENT DECISION APPLICATION FOR PLUMBING PERMIT Application is hereby:TOWN OF SOUTH WINDSOR APPROVE DISAPPROVED BUILDING INSPECTION DEPT. 1540 SULLIVAN AVENUEfifvqce644-2511 Ext. 230 a e Building -Inspector Applications must be printed or typed 1. LOCATION OF JOB: F E E SCHEDULE 2. OWNER:--7hz-AJ nIA412 ,-''V V 0 $19000 10.00 3. ADDRESS: ( w 4P T)r T;Over $1 ,000 - 10.00 Cf- per $1 ,000 or 4. APPLICANT: 72>4 1Jfractionthereof 5. ADDRESS: 6. EST. COST: $ t5v>oO - en 7. IS THIS A CONTRACT COST? p4ES NO 8. FEE ENCLOSED: $ 50,r-2- Z 9. TYPE OF BUILDING: RESIDENTIAL COMMERCIAL 10. TYPE OF JO : ORIGINAL ALTERATION INSTALLATION ADDITION REPAIR BD 2A 11/88 APPLICATION FOR PLUMBING PERMIT (Cont. from Reverse Side) 11. LOCATION OF JOB: C.-LA42-9- 7- GENERAL PLUMBING 12. KIND OF INSTALLATION: Srfwcrje a3. SIZE OF MAIN DRAIN 7 14. NO. OF TOILETS_ _STYLE NO. OF URINALS STYLE 16. NO. OF BATHTUBS_ 16A. NO. OF SHOWERS 1 17. NO. OF LAVATORIES 18. NO. OF SINKS__)DISPOSAL _ 19A. DISWASHER ___ 20. NO. OF CONDUCTORS '-SIZE 21. NO. OF STACKS SIZE 22. AREA OF ROOF 23. NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES KIND 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW? 27. SIZE OF WINDOW 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? 29. SIZE OF DUCTS 30. SEWER OR SEPTIC TANK? 31. SIZE OF WATER MAIN L'L 31A. SIZES OF WATER PIPING & RISERS 32. REMARKS AND FURTHER DETAILS WATER HEATER 33. TYPE 34. MANUFACTURER TANKS SAFETY DEVICES TEMPERATURE 35. CAPACITY 39. RELIEF VALVE 36. TEST PRESSURE LBS. 40. MANUFACTURER 37. WORKING PRESSURE LBS. 41. PRESSURE RELIEF VALVE 38. TYPE 42. MANUFACTURER l a 7 LICENSE NO. DATE SIGNATURE OF APPLICANT PHONE NO. 4,SSA 3 - 6, 1 FOR OFFICE USE ONLY APPLICATION FOR HVAC PERMIT DATE: 7196 NO. TOWN OF SOUTH WINDSOR EST.COS :p . BLDG. PERMIT NO.1540 SULLIVAN AVENUE FEE Fa SOUTH WINDSOR, CT 06074 FEES: 644-2511 - Ext. 230 0 - $19000 - $10.00 1000 or fraction LOCATION OF BUILDING / C110e (57"- thereof - $10.00 OWNER AD RESS TOWN PHONE NO. 29A10' '61CA6 all, Co. y,7o 7a-&o_d- 6-7-c- HVAC CONTRACTOR ADDRESS TOWN PHONE NO. TYPE OF SYSTEM: HEATING TYPE OF BUILDING: RESIDENTIAL 4.- A/C Ae- 01, COMMERCIAL VENTILATION BUSINESS INDUSTRIAL IF HEATING: STEAM LOW PRESSURE LIMIT LBS. HIGH PRESSURE LIMIT LBS. HYDRONIC WARM AIR_ UNIT RADIANT HEATER (INCLUDING WOOD/COAL BURNING STOVE) TYPE OF FUEL: OIL-GPM GAS IN-PUT ELECTRIC KW WOOD COAL OIL TANK - SIZE & LOCATION: INSIDE 4.--o' OUTSIDE CAPACITY33CP LPG TANK - CAPACITY_ EXISTING RADIATION_ ADDITIONAL RADIATION TOTAL RADIATION DESIGN TEMP. OUTSIDE F INSIDE Za 2F DIFFERENCE F TOTAL HEAT LOSS (BTUH) O HEAT LOSS SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL HEATING EQUIPMENT (INCLUDING MAKE & MODEL NO.): GROSS HEATING CAPACITY (INP -BTUH) /aS oo c>' NET RATING (OUTPUT-BTUH) gF-eoO® IF AIR CONDITIONING: DESIGN TEMP. OUTSIDE 9-f`F INSIDE PS °F DIFFERENCE a TOTAL HEAT GAIN (BTUH) HEAT GAIN SHEET MUST ACCOMPANY APPLICATION) DESCRIBE ALL COOLING UIPMENT (INCLUDING MAKE & MODEL NO.): TONNAGE %9 - COOLING CAPACITY (BTUH)J4 a 6c IF VENTILATION: DESCRIBE ALL AIR-HANDLING EQUIPMENT (INCLUDING KITCHEN EXHAUSE EQUIPMENT): TOTAL SIZE OF SYSTEM (CFM) FRESH AIR INTAKE (CFM) PLAN MUST ACCOMPANY APPLICATION) The undersigned hereby applies for a permit to perform the following work and is to comply with all local ordinances and State of Conn. Building Codes in the performance of such work. FURTHER DESCRIPTION OF WORK: STATE LICENSE - NAME 6 TYPE #D TE SIGNATURE OF APPLICANT S r, APPROVED DATE I - B a R CALCULATION SHEET 1503 (Modern Method)Copyright 1971 by The Hydr nits institute OWNER ADDRESS DESIGN TEMPERATURE DIFFERENCE F. DATE COL.A COL.9 COL.C COL.D COL.E COL.F COL.G 1 ROOM 0 H L W H L W H L W H L W H L W Design Waler Temp. 2 ROOM DIMENSIONS, FT. U STUN Per Pool of3LENGTHEXPOSEDWALLS,FT. Radiation Selected 4 WINDOW AND OUTSIDE DOOR AREA U. STUN BTUH STUN STUN STUN 5 WALL CONSTRUCTION ITable 9, Line 3 x H) ROOM LIN.FT.OFTOTALSRADIATION 6 TYPE OF GLASS FROM LINE 12 SELECTED Bottom of table used if r Line S) 7 CEILING CONSTRUCTION Table 9, L x W) C g FLO CONSTRUCTORIONt D_ Table 9, L x W r Lin, F t) E 9 COLD PARTITION CONSTRUCTION F ITable 9, L x H) 10 :C 1 W all 1 With Openinge)O G c 2 Wells(With Openings)e X H 13Wells(With Openings)or Ent.Hall J 11 TOTAL HTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE K L COL.A COLS COL.H COL.i COL.J — COL.K COL.L TOTAL BTUH TOTAL 1 ROOM Q OF BUILDING RADIATION AT SELECTED 0 N L W H L W H L W H L W H L W DESIGN TEMP.* 2 ROOM DIMENSIONS. FT I- DIFFERENCE U 3 LENGTH EXPOSED WALLS, FT 4 WINDOW AND OUTSIDE DOOR AREA a STUN BTUH STUN STUN STUN 5 WALL CONSTRUCTION INCREASE BATHROOMTable9, Lin*3 x HI TOTAL?0% d TYPE OF GLASS B it m I table used lot Line 51 7 CEILING CONSTRUCTION IFOR CONCRETE FLOOR ON Table 9, L is W) GROUND OR FILL AT GRADE LEVEL,USE LINEAR B FLOOR CONSTRUCTIONt FEET OF EXPOSED EDGE Tabla 9,L x W r Lin Ft 1 9 COLD PARTITION CONSTRUCTION Table 9,L x H) 10 c I Wall(With Openings)O 0 2 Wells(With Openings) G X 3 Wells(With Openings)at Ent Hell J - 11 TOTAL BTUH AT 70F TEMP DIFFERENCE' 12 TOTAL BTUH AT DESIGN TEMP DIFFERENCE This form Is svailebie Ir m The Nydronlcs Institute, 36 Russo Plate,Berkeley Heiphtf,N J 07922 FORM 1503 S/N 3420 RIGHT-J E-HORT F.RA lob 1; 1't For; STANLEY & CYNTHIA A. NADOLNY Outs)ae C: 4 db LOT I CLARK STREET Irsid: 4b 70 *1 SOUTH WINDSOR CT DrZsign IC' e6 Da, Y vqe in s 11 e Huml,. 50 By, PARENT DUCT SYSTEMS Grains Wate- 2S on5t, lu, cv a 0t F!i '^IBC S COOLING EQvIPME'1` Makj, Maxe Model Model Type Type Efficiency / HSDF COP/EER/c,EER 3,0 Heating Iaout Sensible Cooiinq 0 Btua Heating O,;tpit E• latent Cooling a Btuh Heating Tome Rise Total Cooling 0 Btuh Actual Heatino ;an "'Co cr"M Actual Cooling ray 1200 CF4 Htg Air Flow Factor C.021 CFM/Btun Clg Air Flory Factor 0,,39 CFM/Btjh Space Thermostat ioad Sensibi. Heat Patio 8, ROOM NAME I AREA HTG I CLG i HTG i CL6 I SQ,FT, BTUH I BT( i CFM I CFh MUD is i 2365 I 2823 I 64 XITCHEN 6435 1 6739 I 230 264 FAMILY ROOM 601' ; 501i I 164 j 191 BAT95 234 24 1338 I 55 1 52 8E0R11ON 1 i 212 I 4849 I 2152 I 132 4 EECR500 2 1 225 4103 f 2119 1 128 i 83 BFDRC"Ok 3 1 180 2352 !1327 64 52 FOYER i 84 I 2816 931 I 17 31 LIVING RQOA I 192 1 2497 2621 t 68 103 OINING ROOK I 192 i 7656 5531 1 208 211 Ent;.e Hoijse 2012 I 44091 1 30604 1200 I 1200 a: .n y l 0 1 0 1 i 0,95 RsF 1 29074 ldt n; Cooii g 4464 j TOTAt i 2072 44097 i 33557 I 1200 1200 MANUAL J: 7th N, RIGHI-" 'V1,13 T 'rd December 2, 1996 To: Engineering Department Town Hall South Windsor, CT 06074 I, Stanley Nadolny, as General Contractor and Homeowner, agree to plant grass on the property at 153 Clark St. , South Windsor, CT , in the Spring of 1997. The lawn cover will meet all regulations and requirements as stated by the Town of South Windsor, Engineering Department. A Z 3 116 anley Nadolny Date g Witness Date S o-e Cep c .-n