Loading...
HomeMy WebLinkAbout152 Debbie DriveTO THE BUILDING INSPECTOR 1P1 theAPPLICATION FOR IrOW14 OF SOUTH WINDSM C 3W PLAN EXAMINATION AND BUILDING PERMIT IMPORTANT — Applicant to complete all items in sections: 1, 11, III, IV, and IX.O ZONINGI• AT (LOCATION) DISTRICT LOCATION NO.) STREET) OF BETWEEN aA,- AND BUILDING CROSS STREET) CROSS STREET) LOT /a.3. /9' Ica SUBDIVISIO.4-, e LOT_BLOCK SIZE f a•gs x l9 q. W 40 II. TYPE AND COST OF BUILDING — A11 applicants complete Parts A — D v A. TYPE OF IMPROVEMENT D. PROPOSED USE — For"Wrecking" most recent use 1 New building Residen ial Nonresidential 2 Addition(It residential, enter number 12 One family 18 Amusement, recreational of new housing units added, if any,13 Two or more family — Enter 19 Church, other religiousinPartD, 13) number of units— — — — -11' 20 Industrial3 Alteration (See 2 above) 14 4 Repair, replacement Transient hotel, motel, 21 Parking garage P , P or dormitory — Enter number 5 Wrecking (1/multifamily residential, of units ——————— — -- 22 Service station, repair garage enter number of units in building in 15 Garage 23 Hospital, institutional Part D, 13) 16 Carport 24 Office, bank, professional 6 Moving (relocation)17 Other — Specify 25 Public utility 7 Foundation only 26 School, library, other educational B. OWNERSHIP 27 Stores, mercantile 8 e Private(individual, corporation,28 Tanks, towers nonprofit institution, etc.) 29 Other — Specify 9 Public(Federal, State, or local g v rnment) C. COST Omit cents) Nonresidential — Describe in detail proposed use of buildings,e.g., food q processing plant, machine shop, laundry building at hospital, elementary 10. Cost of improvement,,,,,,,,,,,,,,,, 25 school, secondary school, college, parochial school, parking garage for, department store, rental office building, office building at industrial plant. To be installed but not included If use of existing building is being changed, enter proposed use. in the above cost a. Electrical....................... b. Plumbing ...................... c.Heating, air conditioning......... d. Other(elevator, etc.)............ ,/,.ITa_ 11. TOTAL COST OF IMPROVEMENT $ yvvv III. SELECTED CHARACTERISTICS OF BUILDING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE F SEWAGE DISPOSAL J. DIMENSIONS 30 Max my(wall bearing) 40 Public or private company Number of stories................cy 31 ffWood frame 41 Private (septic tank, etc.) Total square feet all floors, based onn exterior of floor area, 32 Structural steel dimensions .................... ,3&S 33 R inforced concrete H. TYPE OF WATER SUPPLY 34 Other — Specify 42 9 Public or private company 50. Total land area, sq. ft. ........... g 43 Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES F. PRINCIPAL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL 51. Enclosed ....................... 35 Gas Will there be central air 52. Outdoors........................ conditioning?96 Oil L. RESIDENTIAL BUILDINGS ONLY 37 Electricity 44 Y s 45ffl N 53. Number of bedr ms.............. 38 C aI 39 Other— Specify Will th re be an elevator? 54. Number of Full.......... CD 46 Yes 47 R No batter ms Partial....... IV. IDENTIFICATION — To be compl ted by all applicants n - Name n Mailing addr ss — Number, street, city, and State ZIP code Tel. No. Owner or F Lessee 2. Contractor 3. Architect or Engineer The owner of this building and the undersigned agree to conform to all applicable laws of this jurisdiction. Signat re of applicant Address Application ate 49f CP- a 5 g6 00 NOT WRITE BELOW THIS LINE V. PLAN REVIEW RECORD — For office use Plans Review Required Check Plan Review Date Plans By y Date Plans B NotesqFeeStartedApproved BUILDING PLUMBING MECHANICAL ELECTRICAL OTHER VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Permit or Approval Check Date Obtained Number By Permit or Approval Check ObtDained Number By BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER VII. VALIDATION Building Permit number Building Permit issued -/19 Building Permit Fee $ O ' A y: CIA q M-J%A TITLE TOWN OF SOUTH WINDSOR BUILDING PERMIT Date— may 2 198 6 Fee Paid $5.01-0 0 Eat. Value $.8 4,,0 0 0 Permit N° 15024 on the aide of r,nt- #l S Dehb i e Drive Sam Street No. 15 2 Owner Dart Hill pAn1 t y Applicant Muriel Jacques c CERTIFICATE OF OCCUPANCY ISSUED: Date No. 7588 Fee Paid $ 3 .On CLASSIFICATION Dwelling BUILDING PERWr M 15024 OFFICB OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. , South Windsor, Conn. May 2 186 94io 'to to Cerfifig, That narrt K4 11 Roan l ty is hereby granted permission to Dwelling at estimated value of on the side of Toot 615 Debbie nri3a Street on land owned by Dart Hill Realty Said work to be as described in Application No. 1s1_ and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR. Issued May 2 1%6 J`h Building Inspector. j Streets and sidewalks, obstructed by e=vations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place f or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all coats and damages which it shall sustain, or be compelled to reason therefor." F` Dwelling - Lot #15 Ntn.Vw 1 5/2/86 Dart Hill Realty 152 Debbie Drive Permit #15024 Electrician Richard Barrett 9185 Heating Contr. S.W. Plg./Htg 6447 Plumbing It S.W.Plbg. /Htg. 6997 Oil Burner Certificate of Occupancy 7588 Sewer Permit Plot plan ap rd. p r Engr. Permit No. g TOWN OF SOUTH WINDSOR SOUTH WINDSOR, CONN. y M i Permit NQ 7588i Certificate of Occupancy TH" TO CE T,iFY at the f at No. p- in the: own of South Windsor Connecticut has been erected and completed in accordance with the Building Code and Zoning Regulations of the Town of South Windsor, and is hereby appr ved f occupancy i Building Inspec r wner, Btu' der I Fee Paid`. Date 19 r W7ill;%_ R.Til Ilk fu. DR IV ESKA-0 Ile.AL ISS ILU loop,LL 0 IL 2014 IB SKAKEAr w 7 I oz.61, US i AV SMCE v 1 cy PREPARED FOO" DART HILL REALTY iNC"` A"*l KT COWWJTHWIN)SM 15CALf- iar*40' IF o :' c) lz 1 4 d a11 s to b l t F1E th used b"' t t., s 1 his s oE, the N et atg ted is ttiet j, n + s w, d s I nt du[[ a ou td ftt too th PI _; t- 1 peP'[ t„ nee °{ fs d,, A t c . y.,,. iand Ind1 ss a as` h sraP71° 1itun t Do tk\ Snell S blfct tO b 1 nk Ste 1 ds [ g 1,., n8 t[ 1ed ` N th Tws Pl nc^ [ tl[ e5e otdcrs a o d ttOn, tOr sD- Np. 8u110t n B 9185 ELECTRICAL APPLICATION Application No.1(LESS 9 on the side of Lot #15 Debbie Drive Street Street No. 152 Owner Dart Hill Realty Electrician Richard Barrett FILED IN OFFICE OF The Building Inspector May 14 19 86 INSPECTION. m No Electrical Work shall be started until a Per- mit is granted by the Building Inspector. In New Buildings no wiring shall be started until the plumbing and heating pipes, and the fire stops (if of wood) are installed, without a special permit from the office of the Building Inspector. Electrical Permit No. J FL................... Master License No. 04.7-6-,)l........... TOWN OF SOUTH WINDSOR Building Permit No. /moo-2- BUILDING DEPARTMEN'r Date Filed Date Final Approval ..... ........ . .......................... APPLICATION FOR ELECTRICAL WORK Electrical Inspector JOB LOCATION: 013 OWN co 12........................................... VX,6,v-4\Side of . jetwe I....................!! i.......SmAddressTAN\V-- ,4cA\ . .. . . .....Name of Building Owner I NZ, C.Cm OS(L j If work is for Lessee—Give name Address ................ .... ... ................. ....... ..... ................. Building now occupied as (unless new) No. of family units now ..... .. ........ ... Building to be occupied as Number of family units to be ..... I. . ............. Is this work included in a Building Permit? Permit Fee Zi If no Building Permit) pn, ZPermitteeRkC—\Wl ;..Business Address—e-ION V Telep'ho'n'e**' COSTOF INSTALLATION: TO BE FILLED OUT BY PERMITTEE TO BE WIRED EXISTING APPLIANCES Number of light outlets to be installed Number of convenience outlets t-o be installed Number of present Appliance Circuits ... ... ...... .. ........ Number of switches to be installed . . . Do these include Range Water Heater E]Number of appliances to be installed as listed below) Dryer Air Conditioner Oil Burner E] TYPE RATING NO. Range . . . . . . . . Dish Washer E] Gas Burner E] Well Pump ED Elec. Heaters Range Top . . . . . . Oven . . . . . . . . REMARKS: a perWaterHeater Clothes Washer . . . . Clothes Dryer . . . . . Dish Washer . . . . . . Air Conditioning Motor Oil Burner Motor Gas Burner . . . . . . Circulator Motor . . . . Attic or Large Fan . . . Well Pump . . . . . . Electric Heat . . . . . Other . . . . . . . . .. Number of new Lighting Circuits Number of new Appliance Circuits . . . ......!2............... Number of Heating Circuits 1.................. Number of Motor Circuits Size of present service ......... Size of service to be ................. ....... /0-6-A 6997 PLUMBING APPLICATION No. 6768 on the _.__..._ sick of Lit..._#15 DP-hhi P nr- Suet Street No. ._._15 2 Owner ......._Ilar t H i 11 Rea 1 ty Plumber ....._.5.,hl P & H Filed in Office of The Mk6g Itrpecoor May 15 19$ No person shall aommmm:t, add m c r afar my portion of the drainage :'stem of nay bmUm ezoept to repair le 6) uo&a Pkr- scorned by the Building Impeaw. APPLICATION FOR PLUMBING PERMIT (Continued from R verse Side) 1,3-12— TOWN OF SOUTH WINDSOR, CONN. 11. LOCATION OF JOB Lot #15 Debbie Drive NO. STREET FLOOR APTAO. GENERAL PLUMBING 12. KIND OF INSTALLATION residential 13. SIZE OF MAIN DRAIN 4 1 1 14. NO. OF TOILETS 3 STYLE tank type 15. NO. OF URINALS 0 _STYLE 16. NO.OF BATHTUBS l 17.NO.OF LAVATORIES_3 18. NO.OF SINKS 1 19. NO. OF WASHTUBS 0 - 20. NO.OF CONDUCTORS SIZE 21. NO. OF STACKS__SIZE 'I" 22. AREA OF ROOF 23.NO. OF CATCH BASINS 24. NO. OF FLOOR DRAINS 25. NO. OF OTHER FIXTURES l KIND 3 ' shower 26. ARE TOILET COMPARTMENTS VENTILATED TO OUTER AIR BY A WINDOW?Yes 27. SIZE OF WINDOW ? 28. IF NO WINDOW, WHAT KIND OF VENTILATION IS THERE? electric vent fan 29. SIZE OF DUCTS 311 30. ARE SEWAGE AND WATER FACILITIES AVAILABLE? ves SIGNATURE ADDRESS 524 Burnham Street LICENSE NO. 203068 ESTIMATED COST S1&-•o v TELEPHONE 528-4413 OWNER Dart Hill Realty Inc. ADDRESS 658 Ellington Road WATER HEATER 31. TYPE gas fired 32. MANUFACTURER A• 0• Smith TANK SAFETY DEVICES 33. CAPACITY 40 as 1 1 nn 37. TEMPERATURE RELIEF VALVE o?/c 34. TEST PRESSURE_f U/,S J 38. MANUFACTURER_ W,6127_1 35. WORKING PRESSURE 39. PRESSURE RELIEF VALVE 36. TYPE C f l /ih 40. MANUFACTURER ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE OWNER OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. CD962 ATE SIG AT E OF APP ANT r PERMIT # Application For 6246 6447 DEPARTMENT DECISION 4-1 Cd W Heating PermitO 3 APPLICATION IS HEREBY: o DEPARTMENT OF LICENSES AND INSPECTIONSas N +'APPROVED DISAPPROVED TOWN OF SOUTH WINDSOR o0A 5114/86 Thmas P. D' Auria DATE CHIEF INSPECTOR APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE MEL W O t» o v 1. LOCATION OF JOB 0 r' 152 Debbie Drive C NO. STREET 4 15 LOT NO.FLOOR APT. NO. 2 2. OWNER Dart Hill Realty Inc . Cd Cs o ADDRESS 658 Ellington Road 0 3 44 South Windsor 4.PHONE 282-0628 11. APPLICANT Sn 1 h Windsor Plumbing m 0 go ADDRESS 594 Burnham Street a 4) w Rni1th WindRnr -7.PHONE 529-4413 S. LICENSE NO. 2()71 !9Q a C w 1 B. EXPIRATION DATE OF LICENSE 10/1/8 7 v CT' j .G 10. ESTIMATED COST =d a w -o 11. IS THIS A CONTRACT COST?BE YES Nobo P 12. FEE ENCLOSED s Permit 15024 a PC a)IS. TYPE OF BUILDING: rnWbo RESIDENTIAL COMMERCIAL 3 14. TYPE OF JOB: INDUSTRIAL ORIGINAL 11ALTERATIONINSTALLATIONADDITION REPAIR APPLICATION FOR HEATING PERMIT (Continued it m Reverse Side) 11. LOCATION OF JOB Lot #15 Debbie Drive NO. STREET FLOOR APT.NO. 12. TYPE OF INSTALLATION; OIL BURNER ELECTRIC VENTILATION SPRINKLER 10 GAS BURNER STACK INCINERATOR I MISCELLANEOUS L )19_7_' IDENTIFY SIZE LOCATION SIZE SIZE 13. OF TANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NO. 1&2G,& B.T.U. OR SQ. FT. NET B.T.U. OR SQ. FT. GROSS ^ FIRING RATE FLOORS TO BE HEATED MQJQ NEW OR OLD BUILDING INSULATEDINSULATED — YES OR NO 1 C f TYPE OF WALL INSULATION &Lezc`ROOF OR CEILING C'Ait INSULATION CL AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION INDOOR-OUTDOOR TEMPERATURE DIFFERENCE L7" Li FAHRENHEIT _ MAKE OF RADIATION: ASEBOA . COPPER CONVECTORS. OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SO. FT. OR B.T.U. U^ /e- DESCRIPTION OF WORK 011zzZ15. TO BE DONE; L 2'I 16. HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS); ROOM SIZE AND DooRs AREA — SQUARE FEET VOLUME B.T.U. B.T.U.DISTRIBUTION INSTALLED TOTAL TOTAL !n LL ROOM L W N AND CW GROSS GLASS NET WALL CEILING FLOOR CU.FT. AT 70•F CORRECTED J j U. RAD. REGISTER SIZE t WALL 'cto INFILT.) TEMP. TO 7F f TYPE AND SIZE OR LEADER IFDIFF. F F h SG' FT' FREE AREA TOTALS A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND k4 Gig/-1 i B.T.U./HR, C. PIPING, OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY; NAME ADDRESS SUBCONTRACTORS AND 18. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. ZAg DATE SIGNAT i!! 7 AP LICA AODOM ION TEMPtRATURt DIFFKRKNCE F. DATW OL.A R COIL.C COL.O COL.IFCOL.O 1 ROOM r[t M L OfW w N L N W OaMM water TeMW ------- 3 ROOM DIMENSIONS.PT. low o?Q q?Q I L OHO L / iTUH Per IrMrt of 3 LENGTH EXPOSED WALLS,FT. t j 2 Lt RaObtlrw fAesler 46 WONIOW AND UTSIDE DOOR AREA r354 a*j s STY" 1fTU" STUN STUN STUN d WALL CONSTRUCTION Table!,LMre 3 x NI d7 O Q Q era Q Q TOTALS ADIA'"ON d 1 TYPE F GLASS FROM LINK 12 SELECTED 40eee«n Of table sisal for Line a) 7`0 4 D 4 1_1r/4d10 d0 7 CEILING CONSTRUCTION C a Table 0.L x w) G`4560 0" E FLOOR CONSTRUCTIONt f Dv Table S,L x W or LII FL) QS Apa Q 7d D 115eQ S COLD PARTITION CONSTRUCTION F ,+,+ g Z Table*.L x N) O j, / a wen(wlth oPsnl. a 2 walls 4%Vhh OpenlnW i X 6 4 3 3 wells(w1W ovenkow o.Ent.Hail J 42 TOTAL STUH AT 70F TEMP.pIFRElIENCE• 0 ytTOTAL STUM AT V`ESIGN TEMP. DIFFERENCE G l9 U G47 0O4 IC1`O' K J l L d COL.A COL-®COL.H r COL.! COL,i _ COL.K` COL.L t O AL iITUM TQT 1t. ifOOM C J `t`cT g .!'L7u/z_.OF BUILDING D Tq- AT.......... ....-._ __. ........ .. D Fi ill ( Mf I. Mi M! e ;, 1 w ' !~l 1. '11f H t, i 3R31QM T[MP.:. 2 ROOM DIMENSIONS,FT. R f= fit' y 1 `,)."'e.. ' l }® rG / aF Kl tac r LENsiTH ExP Eo 1MALi.S.FT. fd 2 3 Ctt' d WINDOW AND OUTSIDE DOOR AREA t11t Till! STt,gt SR1N1 07'aJN II lNALL CONSTRUCTION 0114C'REME BATHROOM f mbila E.LMIe 3 x H) C / v 0 TOTAL PV% iftelamof..11"us"for Lim so - — Ira FOR corvr_13ET'E Fi._Ori OltCi1L/Np COIi1STRUCTION f ,,9 y GAOUN.:iXI FILL.AT0(Table S.L x o 4 6F 0 v L,'GRADE LEVEL..USE LINEAR S FUNM CONIFTRUCTIONt FEET OF FIIPOSEO SEDGE Taw 96 L x w M Lift Ft) 0 COLD PARTITION CONSTRUCTION Table t.L x N) 10 A { Wall 0010 Opaa iaWi A a 3 wail.(With Opown"or Ent HMI4V O 1! TOTAL STUN AT 70F TEMP.DIPFERENCE• JD fir" 3 D©0 0 S!! 12 V"OTAt STUN MPATDMIGNTEMP.OIFFEMI E Q' p T><M farsnn b evaNabN f an The HYlronias 1 rw*bosli,40 Pt4NW P/w0.AerlLeleAl HMEI+tsr N.J.07922 F; Rim 1503