Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
151 Sand Hill Road (2)
STRUCTURAL ENGINEERS Statement of Special Inspections COALITION CONNECTICUT ENGINEERS IN PRIVATE PRACTICE Project: SBA Tower #10125-087 Location South Windsor, CT Owner: SBA, Inc. Owner's Address: 80 Eastern Boulevard, Glastonbury, CT. 06033 Architect of Record: Murali D. Atluru, PE. Registration #11569 Engineer of Record: Keith J. Tindall, PE. Registration #21551 This Statement of Special Inspections is submitted as a condition for permit issuance in accordance with the Special Inspection requirements of the BOCA National Building Code. It includes a Schedule of Special Inspection Services applicable to this project as well as the name of the Special Inspector and the identity of other approved agencies intended to be retained for conducting these inspections. The Special Inspector shall keep records of all inspections and shall furnish inspection reports to the Building Official, Structural Engineer and Architect of Record. Discovered discrepancies shall be brought to the immediate attention of the Contractor for correction. If such discrepancies are not corrected, the discrepancies shall be brought to the attention of the Building Official, Engineer and Architect of Record. The Special ispection program does not relieve the Contractor of his or her responsibilities. Interim reports shall be submitted to the Building Official, Owner, Engineer and Architect of Record. A Final Report of Special Inspections documenting completion of all required Special Inspections and correction of any discrepancies noted in the inspections shall be submitted prior to issuance of a Certificate of Use and Occupancy. Job site safety and means and methods of construction are solely the responsibility of the Contractor. Interim Report Frequency:or El per attached schedule. Prepared by: OF CQNNF R0*iC'• Ryan R. Roy PE 440i 6: type or print name) No.22118 Z/CO••`.. 10N AL Signature Date Design,804ssional Seal Owners Authorization: Building Official's Acceptance: ignature Date Signature Date SEC/CT Form 101 • Statement of Special Inspections • ©SEC/CT 1999 Sheet 2 of 6 Project: SBA Tower# 10125-087 Schedule of Special Inspection Services The following sheets comprise the required schedule of special inspections for this project. The construction divisions which require special inspections for this project are as follows: X Soils and Foundations Cold-Formed Steel Framing X Cast-in-Place Concrete Spray Fire Resistant Material Precast Concrete Wood Construction Masonry Exterior Insulation and Finish System X Structural Steel Special Cases Inspection Agents Firm Address 1. Special Inspector Jaworski Geotech, Inc 114 Woodlawn Road Ryan R. Roy, PE Berlin,CT 06037 2. Testing Laboratory Eastern Materials Testing Lab,114 Woodlawn Road a division of Jaworski Geotech, Inc Berlin,CT 06037 3. Testing Laboratory 4. Other Note: The qualifications of all personnel performing Special Inspection activities are subject to the approval of the Building Official. The inspection and testing agent shall be engaged by the Owner or the Owner's Agent, and not by the Contractor or Subcontractor whose work is to be inspected or tested. Any conflicts of interest must be disclosed to the Building Official, prior to commencing work. The credentials of all inspectors and testing technicians shall be provided if requested. It is recommended that the person administering the Special Inspections program be a Professional Engineer experienced in the design of buildings. Key for Minimum Qualifications of Inspection Agents(where indicated on Schedules) PE Professional Engineer EIT Engineer in Training ACI American Concrete Institute Certified Concrete Field Testing Technician AWS American Welding Society Certified Welding Inspector ASNT American Society of Non-Destructive Testing—Level II or III qualifications of inspection agents may be indicated on the Schedule in instances where the Structural Engineer deems such requirements are appropriate. SEC/CT Form 101 9 Statement of Special Inspections • ©SEC/CT 1999 t Schedule of Special Inspection Serv, s Sheet 3 of 6 Soils and Foundations Project: SBA Tower# 10125-087 Item Agent No. Scope Qualif.) 1. Shallow Foundations 2 Review the subgrade preparation in accordance with the Geotechnical recommendations and project specifications. 2. Controlled Structural Fill 2 Complete laboratory gradation and density analyses. Monitor placement of compacted fill and perform field density testing. 3. Deep Foundations 4. Other SEC/CT Form 101 • Statement of Special Inspections 9 ©SEC/CT 1999 Schedule of Special Insp ction Sere a Sheet 4 of 6 Cast-in-Place Concrete Project: SBA Tower# 10125-087 Item Agent No. Scope ualif. 1. Mix Design 1, 2 Review concrete mix design to ensure compliance with project specifications. 2. Material Certification 3. Reinforcement Installation 2 Review steel reinforcement to ensure compliance with project specifications. 4. Post-Tensioning Operations 5. Batching Plant Formwork Geometry 2 Verify formwork for general conformance to the size specified. 7. Concrete Placement 2 Conduct concrete slump and air test on every 50 cy of concrete placed. 8. Evaluation of Concrete 2 Prepare four(4)test cylinders on every 50 cy of concrete Strength placed. 9. Curing and Protection 2 Maintain proper curing and protection techniques in compliance with ACI 318-95 10. Other SEUCT Fon. A Statement of Special Inspections • ©SL -;T 1999 Schedule of Special Inspection Services Sheet 5 of 6 Structural Steel Project: SBA Tower# 10125-087 Item Agent No. Scope Qualif.) 1. Fabricator Certification/ Quality Control Procedures 2. Material Certification 1,2 Review material certification test reports for bolt and structural steel. 3. Open Web Steel Joists 4. Bolting 2 Review 10% of bolted connections in accordance with AISC specifications 5. Welding 6. Shear Connectors 2 Review structural details for general conformance with project specifications. 7. Structural Details 8. Metal Deck 9. Other STRUCTURAL ENGINEERS Final Report of Special Inspections COALITION CONNECTICUT ENGINEERS IN PRIVATE PRACTICE Project: SBA Tower # 10125-087 Location South Windsor, CT Owner: SBA, Inc. Owner's Address: 80 Eastern Boulevard, Glastonbury, CT 06033 Architect of Record: Murali D. Atluru, PE. Registration # 11569 Engineer of Record: Keith J. Tindall, PE. Registration # 21551 To the best of my information, knowledge and belief, the Special Inspections required for this project, and itemized in the Statement of Special Inspections submitted for permit, have been performed and all discovered discrepancies have been reported and resolved other than the following: Comments: Attach continuation sheets if required to complete the description of corrections) Interim reports submitted prior to this final report form a basis for and are to be considered an integral part of this final report. uueeeru,,sei Respectfully submitted: ee•``°°F CONN °0`°•, Special Inspector J`•yp,N R.q0` Bran R Rov R F r i type or print name) o' r i Y r Z_ 0 No.22118 r NN AA ee Signature Date Des Seal