Loading...
HomeMy WebLinkAbout15 Wood Pond Road3 TO THE BUILDING INSPECTOR of the APPLICATION FOR 1170NI N OF S0IT 4 W1IIIIIDSQR,CAMC PLAN EXAMINATION A N D BUILDING PERMIT IMPORTANT — Applicant to complete all items in sections: 1, 11, III, IV, and IX.O ZONING / •AT (LOCATION)_ / S r '0 1 '4 DISTRICT LOCATION NO.) STRE T) OF BETWEEN ir/f 1 AND BUILDING CROSP STREET) CROSS STREET) SUBDIVISION d J LOT BL LOT OCK SIZE NII. TYPE AND COST OF BUILDING — All applicants complete Parts A — D o A. TYPE IMPROVEMENT D. PROPOSED USE — For"Wrecking" most recent use IT 1 New building Reside al Nonresidential 2 Addition(1/residential, enter number 12 One family 18 Amusement, recreational o/new housing units added, if any,13 Two or more family — Enter 19 Church, other religiousinPartD, 13) Y number of units— — — — -),. 20 Industrial3 Alteration (See 2 above) 14 Transient hotel, motel,21 Parking garage4 Repair, replacement or dormitory — Enter number 5 Wrecking (1/multifamily residential, 22 Service station, repair garage enter number of units in building in 15 Zlolarungeits 23 Hospital, institutional Part D, 13) 24 Office bank professional16Carport6 Moving (relocation) 17 Other — Specify 25 Public utility7 Foundation only 26 School, library, other educational B. OWN E HI P 27 Stores, merconfi le 8 Private(individual, corporation,28 Tanks, towers nonprofit institution,etc.) 29 Other — Specify 9 Public (Federal, State, or local government) C. COST Omit cents) Nonresidential — Describe in detail proposed use of buildings, e.g., food processing plant, machine shop, laundry building at hospital,elementary 10. Cost of improvement•,,,,,,,•,,•,,,, S 1pyedd school, secondary school, college, parochial school, parking garage for, department store, rental office building, office building at industrial plant.To be installed but not included If use of existing building is being changed, enter proposed use. in the above cost a. Electrical...................... b. Plumbing ...................... c. Heating, air 7 d. Other(elevator, etc.)............ 11. TOTAL COST OF IMPROVEMENT ; .30 d III. SELECTED CHARACTERISTICS OF BUILDING — For new buildings and additions, complete Parts E — L; for wrecking, complete only Part J, for all others skip to IV. E. PRINCIPAL TYPE OF FRAME G. TYPE 0 SEWAGE DISPOSAL J. DIMENSIONS 30 sonry(wall bearing) 40 " Public or private company 48. Number of stories................ 31 EWood frame 41 Private (septic tank, etc.) 49• Total square feet of floor area, all floors, based on exterior 32 Structural steel dimensions .................... /7 h 33 Reinforced concrete H. TYPE WATER SUPPLY 34 Other — Specify 42 Public or private company 50. Total land area, sq. ft. ........... 43 Private(well, cistern) K. NUMBER OF OFF-STREET PARKING SPACES F. PRINCI AL TYPE OF HEATING FUEL I. TYPE OF MECHANICAL 51. Enclosed ....................... 35 s Will there be central air 52. Outdoors........................ 36 Oil conditioning?L. RESIDENTIAL BUILDINGS ONLY 37 Electricity 44 Yes 45 No 53. Numb r f b dr ms.............. 38 C al 39 Oth r— Specify WiII ther b an elevator? 54. Number F Full.......... 46 Y s 47 /No bothr ms rani a I........ NOTES and Data — (For department use) IV. IDENTIFICATION — To be completed by all applicants Nam Mailing address — Number, street, city, and State ZIP code T I. No. Owner or Lessee 2. Contractor 3. Architect or Engineer Th own r of this building and the undersigned agree to conform to all applicable laws of this jurisdiction. Signature of applicant Address Application date r DO NOT WRITE BELOW THIS LINE V. PLAN REVIEW RECORD — For office use Plans R vi w R uired Check Plan Review Date Plans B Date Plans B NotesqFeeStartedyApprovedy BUILDING PLUMBING MECHANICAL ELECTRICAL OTHER VI. ADDITIONAL PERMITS REQUIRED OR OTHER JURISDICTION APPROVALS Permit r Approval Check ObDa ned ate Number By Permit or Approval Check ObtDained ote Number By BOILER PLUMBING CURB OR SIDEWALK CUT ROOFING ELEVATOR SEWER ELECTRICAL SIGN OR BILLBOARD FURNACE STREET GRADES GRADING USE OF PUBLIC AREAS OIL BURNER WRECKING OTHER OTHER VII. VALIDATION Building 13005Permitnumber Building Permit issu d Nov. 17 19 82 Bui Iding P rmit Fee $ 378.00 A roved b t TI r N iilN NiwN i!•+•a•.r.a. lw•. w• s•w l•rw NiMw• M• a • N .ND• ! as On mass so S=1i' i . N• on N a" N• .NN w w -A•a • « r.l soon Dow"@ *are r •rfy s go at was use ON no an 4 some ads ' i'i ' N rr an DO 5 UIS ban in10 JOB as as WO sun ONStnlrrNOIN :Nsea un ning we totole2 in see* ft—LqBe.iIRS:. 1 8101111 a Ioil i tom: i: UN• 'sriispouse N.gra •sa a N rK onNNa lira N .trNsongNNN " Y N t N •• M.is„ ii ' t a S sss: NM ..' s 'li° uHs •• •r sra N•t=• • Ns:: es: •• amia • • rr r t• • il.,I Ole as iasfii iiaiiiiDow; 0 .•NDUNE • Nir ss .0.1 iN • r go assuages On: see ass: .. ..: 86 i`. siAUllt.lNsame: Nami:pl::::r::: r:••raNN:.N••N.t: .• • •r•.N!!N•at ••N N•..* N Ms:_: a. ew i•.•.! i •• q •• r 1lfNSi=s:= t••:i\: ::: :: : :::::::::::::::::::::::••H:::r::::::r::•:a: a•q::r•:%%A : !: a:`,i •: ar • '_j•'! . N•N• ins. '_ _ ::===•rr• .=:_•=.=.ss..................•::••.._.•:_ :=' =s:s!s•ai•I.•• ta iiir:lS =i3it Hm000"mem,noIS =ii=i '• i P _i ii'.•ii • _ ••• • • •i•i• isiiiiiiiiiiiiiiiii.860moiiiiiiiiiii•iiiiissaii!•iu siiir onesOman*masiss• !• a:: *•. t•a`a • •aNr • :.•fa son i•=i•i • 'itttt ==ii:=0=i' ra es tst'tttt•'s•tar'.r•..attrttts•..ra at ttttrariltt= i••': r=HU111:'r t ti itn o"i•na spsar .. •. ••_..::•.:.s••......•_..••aa..srs..!•. trs s ! ..at ri•r=r : rrIi-a r . .ri • i• u• i iansias" 9 .Z.sr .:•isr i•+s •:•...ra.=a.=s s.a ls..aa .Y:t•.atta.Mit•i.r ar i.:1:fa 1 t•. •N !a •t. ie= ii=s sess;jsr=e=:sei=;:ge3 =::==s:'s:=s:e:cse=z'UHHHO s:: ::;: ::=:smaue: ss;rs:a=0: =;:: as;s :1 $s .':s :sl:.:: 1....sa: Hss :s s:s I •ss :e s ss : ss i s s: .ass. ss s= is s N.:.:h. s. •.s •sN: • sfa s s • . .•.....• sea sr •. .. •a s r •• ii ess= :sees=iel.=se:=='sEe=es=esseeeee i's==: ess :s'sa=e s 11==eeeesne mosmo e=s==:s s:9e:====aas: =s s',a s ism, i pie 's a•iiia tr=:.t.i:..asi=:raai=...tart=:r•:•at.:ra r nitrat:.trrt.•.is.i•str r'firiii•aaaii••si1iis_iiii 1 a!iiC r •w .ia'... . 60 s:i=s:e :e:eee:=e'se'ee: :ie=eases;a ==::E ='ss$er=.s'::= ens s isa: .4REs = i::u :ii ii:. ::a•s:a:isaa••:•a•!:iasa.S•Saass ri as is.aa.a.::N•=si.i== i:..:i:=: i•• i r s: ...s s.. 1'a Is si : $s'i ians: psis i s•s . ::asir•.i===si=s.•_. _ •i.=••..:•a:=.•.i s a=.••isr.• __ _• .=!t i r i • i _._a• t r 5:.3s:s:::i:a.=as:sass::i:::::= :i:.s:ss:.::::::::s::::::::::::::::::::s:.:s::::::.:i:sa::::•iil: : :was s.iii: •=:i ..i:1aOHII iissiiisi:=== s:si::s:=:;:::::::=es:::ss::::=s;:::::s::se:::e: e::=::::=e::l ;=:;: e:; ::s: := : : s:• sad:rz:: s::l :_11:::;:;IM f TOWN OF SOUTH WINDSOR BUILDING PERMIT Date Nov. 17 19 82. Fee Paid 3 8.00 Est, Value $. .6.3,000.00 Permit N° 13005 on the ade of Lot #9 Wood Pond Road Street Street No. 15 Owner T.a CaUa C nn G t r>>n t i nn C n Applicant G. A. LaCava CERTIFICATE OF OCCUPANCY ISSUED: Date No. 6204 Fee Paid $ 3.n n CLASSIFICATION Dwelling BUHDING PERNffr N° 130U5 OFFICB OF THE BUILDING INSPECTOR of the Town of South Windsor, Conn. South Windsor, Conn. Nov. 17 19 82 ar#iz is to (frrttlfti, That T n cwrs con s t t' is t i on ro_ is hereby granted permission to Dwe I I i na at estimated value of $ 00 on the side of T „* #9 Tan 4 -wnd R a Street on land owned by T a('avA Con4truction Co. Said Work to be as described in Application No. and to conform to specifications and plans filed with said Application, and Building By- Laws of THE TOWN OF SOUTH WINDSOR. Issued 19 82. wilding Inspector. Streets and sidewalks, obstructed by ezcavations or building materials, must be guarded by barriers during the day and by both barriers and colored lights by night. SECTION 1343, GENERAL STATUTES OF CONNECTICUT: "When any person shall place or keep building materials, or any obstacle in any highway (or any sidewalk) either with or without a license therefor from the city or borough in which such highway may be situated, he shall pay said city, town or borough all costa and damages which it shall sustain, or be compelled to reason therefor" I I I I Dwelling - Lot #9 Wood Pond It 11/17/8 LaCava Construction Co. 1.5 Wood Pond Road Permit # 13005 Electrician Garber-Doran i852 Heating Contr. D.Bartone P & H # 5581 Plumbing " D. Bartone P & H # 6087 Oil Burner Certificate of Occupancy 6204 Plot plan apprd per Engr. i Permit No. i TOWN OF SOUTH WINDSOR SOUTH WINDSOR, CONN. f I Permit N 6204 Certificate of Occupancy TH ,, TO CERTIFY the at No. in the T of South Windsor, Connecticut, has been erected and completed in accordance wi the B ding Code and Zoning Regulations of the Town of South Windsor, and is hereby ap rove four occup4ncy., Building Inspector L`d .t - !"=`.fir' "_ - .• Owner, Builder Fee Paid . Date 19 cJ3 3 s t j i 7852 ELECTRICAL APPLICATION Application No. 8963 on the side of Lot #9 Street Street No. 15 We-, Owner k CGc vet Electrician C-a rh e r ora-n FILED IN OFFICE OF The Building Inspector Jan. 1./ 1983 INSPECTION. 93)-No Electrical Work shall be started until a Per- mit is granted by the Building Inspector. In New Buildings no wiring shall be started until the plumbing and heating pipes, and the fire stops (if of wood) are installed, without a special permit from the office of the Building Inspector. po APPLICATION FOR PERMIT TO DO ELECTRICAI. WORK. No. ......8 9.63....... ...... Permit No. ...L85 2... ..... . TO THE BUILDING INSPECTOR of the TOWN OF SOUTH WINDSOR, CONN. T.. hereby make application to, perform Electr cal Work according to detailed description below. All provisions of the Rules for Electrical Installation, Section 48, Building By-Laws, shall be complied with whether specified herein or not. j - South Windsor, Conn., Z 19 Sign here y Address Po Location Side of .. c'^'C l' GO.f!'.°:..... Nature of Building !eS c o-,c ... How many stories I... ... .-.. ....................................... .. ................ e k.-- How many familiesNeworoldBuilding V Kind of Installation How many Stores ............7.... ....................................................................... Owner G-c. e A&I. ... . c tT...... ... ..... _... .. Address /.P S—..S”.lam.........../Oe.._.9,;._......_.eA e T Architect . ...... ...... Address Builder Address sd.''. . ............. . ............................_.........e Electrician ..............•/... .......... Address . . ..... 5.. '.'.........`............................................._......._.... Size of Main Wires . ... ....... ... No. of Light Loops No. of Heat Loops .. No. of Power Loops .............. _...._.... No. of Light Outlets . . . .. No. of Heat Outlets No. of Power Outlets ..........4. .. .. ...... NoO of Light Circuits .. S.. . . . No. of Heat Circuits No. of Power Circuits .. No. of Sockets d.. No. of Heat Receptacles No. of Motors ....... No. of Panels ................ .. .. Size of Heat Circuit No. of Power Receptacles No. of Switches ............. .... a . Total Wattage ... ....... .. .. ... . `....... ..... Size of Power Circuit Total Horsepower No. of Straight Electric Fixtures ..... ...../.. . -............... .... No. of Combination Fixtures ... ..7 No. of Receptacles .......................4 O ........ ....... .... ..... . No. of Cord Drops .... .. ............ .. .................. .......... ........... .. Remarks: For other kind of Installation ..... .........G'".f(... ......... . ..................... .................. ......................... ........... .... .......... C. 'c T c...................... I...... .............................................. _................................................................................................... Estimated Cost .... ......... ..P..r Q... 6087 PLUMBING APPLICATION App]a No. 6866 on the Yti aide of cQ d Sa+ect Street r4o. ._._ 15 Owner ... u Ca4z c ( T Plumber _V-4--8 CLA t- Filed in Office of The Bing Iaipocoor Feb. 25 83 mgmucnox. No person shall aoastruct, add m or aloes ay portion of the draimge syaoean of-my busg cept to repair lealm) uool a pp is graaoed by the Building bVecow. J Application No. .....6.86.6................... Permit No. ....6.08.7............... TO THE BUILDING INSPECTOR of the TOWN OF SOUTH WINDSOR, CONN. hereby make application to perform plumbing according to detailed description below. All provisions of the Rules for Sanitation, By-Laws, Sections 33 to 47 inclusive, shall be complied with whether specified herein or not. South Windsor, 19 Sign here 6-f 3 Address .. . ............. ............................................................................ Location .........CA-r0."0Cff...6"d....Pop... . . side of .............................................................................................. Street Natureof Building How many stories .. .............................................I.. .................................. Ir C_ Owner .................. aw .... . .(,VW.01........Address Architect ............ ... ........... .... .. ........................... .................... Address ..... ................................................................................. ................... Builder ... ...................... Address ................. . 6V A,1 CrO 0 23Plumber ...... Address7 DRAINAGE CESSPOOLS, How many Where located Are they water tight Of what materials are they built ........ .............. Size of pipe from house to cesspool Kind of pipe MAINDRAIN IN CELLAR, Material .. . ... ....... Diameter .............................................................................................................. Aboveor below cellar bottom . . . ..... ............................ ....I..................................................................................................... SOIL PIPES, Material 19-8 5............ Diameter WASTE PIPES, Material .. .... Diameter .....I.......(--z=.............................................. TRAPSyType proposed to use is RAINWATER LEADERS, where do they run to .. .... . . . ........ ...................................................................................................... REFRIGERATORWASTES, where do they run to TANKOVERFLOWS, where do they run to FIXTURES WATER CLOSETS, How many --_3...... Where located ... . ................................................................................... Distance from trap to vertical soil pipe ................... .................. Pattern WASH TRAYS, How many . .. .................... .......... Where located . . . ........... .................... ........................................ SINKS, How many .... ......... .. .................V.......................................... . Where located . ... ..... ............................................................................... BUTLER'S SINKS, How many ..................................................... Where located . . . .................................................................................. REFRIGERATOR SINKS, How many . ........................... ..... Where located .............................................................................................. LAVATORIES,How many . .. ...............-3.................................. Where located ................................................................................................... BATHTUBS,How many.......................I... Where located ..................................................................................................... URINALS, How many ...... ..... ...... .............................................. Where located .................................................................................................. Are water closets and urinals to be local vented If not, is there a window in outer wall ofroom where same are to be located I................................................................................................... Estimated Cost .---?......0. PERMIT Application For 6 6 8 2 5581 Cdo DEPARTMENT DECISION Heating Permit 3 E APPLICATION IS HEREBY: DEPARTMENT OF LICENSES AND INSPECTIONS N APPROVED ISAPPROVfD TOWN OF SOUTH WINDSOR o ` 502/2 /83 GATE INSPECTOR O APPLICATIONS MUST BE PRINTED OR TYPED. BEGIN WITH NUMBER ONE BELOW en 0 v 1. LOCATION OF JOB s0 _O 15 r Q Roadf v NO. STREET co9 OT NO. FLOOR APT. NOO O 2. OWNER 1cis Ie o O f. ADDRESS3 4.PHONECc 4 b f I(nS. APPLICANT o m 6. ADDRESS LaSo , n T o C 740 , PHONE 2 S. LICENSE NO.O 3 C3 p ' 9. EXPIRATION DATE OF LICENSE_ '•" C—c CO 10. ESTIMATED COST 7 be 11. IS THIS A CONTRACT COSTS NOrw 12. FEE ENCLOSED $ Permit #13005 x 0 13. TYPE OFrn BUILDING: bo R[fID[MTIALpC COMMERCIAL ce INDUSTRIAL14. TYPE OF JOB: INAL ALTERATIONINSTALLATIONADDITION REPAIR APPLICATION FOR HEATING PERMIT (Continued it m Reverse Side) 11. LOCATION OF JOB 00 l NO. STREET FLO R AFT.N . 12. TYPE OF INSTALLATION: OIL BURNER ELECTRIC VENTILATION SPRINKLER La"l GAS BURNER STACK INCINERATOR MISCELLANEOUS IDENTIFY SIZE LOCATION SIZE SIZE 13. OF TANK OF TANK OF FILL OF VENT 14. B.T.U. EQUIP. AT REGISTER FURNACE MAKE AND NO. AT BONNET FIRING RATE BOILER OR FURNACE MAKE AND NOI A 1 OO B.T.U. OR SQ. FT. NET B.T.U. OR SQ. FT. GROSS LP_WFIRING RATE FLOORS TO BE HEATED NEW OR OLp BUILDING f'INSULATED - YES OR NO TYPE OF WALLr-rlg^,A d INSULATION 3 `( L" ROOF OR CEILING INSULATION AVG. SYSTEM WATER TEMP. B.T.U./SQ. FT./HR. EMISSION 0 INDOOR-OUTDOOR TEMPERATURE DIFFERENCE C) lad FAHRENHEIT MAKE OF RADIATION: BASEBOARD. COPPER CONVECTORS. OR C.I. RADIATION. OUTPUT PER SECTION OR LINEAL OF RADIATION. SQ. FT. OR B.T.U. DESCRIPTION OF WORK 15. TO BE DONE: m HEAT LOSS SCHEDULE. (TO BE INCLUDED FOR ALL JOBS): ROOM SIZE WINDOWS AREA - SQUARE FEET 0.T.U. e.T.U.DISTRIBUTION INSTALLED AND DOORS VOLUME TOTAL TOTAL ROOM NO.GROSS GLASS NET WALL CEILING FLOOR CU.FT. AT 70'F CORRECTED J j 4 LL REGISTER L W N AND TEMP. TO TYPE AND SIZE RAD. OR LEADER SIZE < WALL IF ( O INFILT.1 DIFF. F m N SO' FT' FREE AREA 75< TOTALS A. HEAT LOSS FROM BUILDING B.T.U./HR. B. DOMESTIC HOT WATER DEMAND B.T.U./HR. C. PIPING. OTHER THAN NORMAL B.T.U./HR. ALLOWANCE FOR HEAT VALVE OF FUEL (A B C) FACTOR 17. ELECTRICAL WORK BY; NAME ADDRESS SUBCONTRACTORS AND IS. THEIR TRADES ALL WORK COVERED BY THIS APPLICATION HAS BEEN AUTHORIZED BY THE (OWNER) OR (AGENT) OF THIS PROPERTY AND WILL BE DONE IN STRICT ACCORDANCE WITH THE BUILDING CODE. APPLICATION TO BE COMPLETELY FILLED IN. 2- It / P3 - 2aa D TE SIGNATURE OF APPLICANT s R CALCULATION SHEET 1503 (Modern Method) Copyright 1977 by TIN Hydropin Iwtitute OWNER PON= ADDRESS,' Z' 9 rye-` r yt. +DESIGN TEMPERATURE DIFFERENfrE F. GATECOL.A COL.S COL.C COL.O COL.E COL.F COL.f31ROOM O H H H M w Design Wat&TMIaB,2 ROOM DIMENSIONS,FT. O kv3LENGTHEXPOSEDWALLS, FT. U U /G I*/ / vgx STUN per Foot ofQ Zi Radiation Seleetes.,,4 WINDOW AND OUTSIDE DOOR AREA BTUH STUN Uff TUN BTUMBT5WALLCONSTRUCTIONDO H Table 9,Lirte 3 x W D A OM LIM.•T.OF 6 TYPE OF GLASS 0 q 11 0 a TOTALS RAD(IAMN QIL0 Q r v 0 dG iRO1N Llf[rt 12 iBLtCTED €B ttom of table used to.Line,b 6o Z I7CEILINGCONSTRUCTION r Q Q wTable9,L x WI CdlaeFLOORCONSTRUCTION`f g p 'X Table 9, L x W or Lin Ft.) 9 COLD PARTITION CONSTRUCTION OfTabI9, L x H) 10 -0 1 Wall(With Openings) O O p J d 8ce2Walls(With Openings) e X 3 Wells(With Openings)Or Ent. Hall J Z d V 11 TOTAL BTUH AT 70F TEMP. DIFFERENCE'vU ov paD p012TOTALSTUNATDESIGNTEMP. DIFFERENCE K p ddvfl Z u v COL.A COLS - COL.H ' COL. I COL.J COL.K COL,{ 0 1 ROOM T0fI1 TOTAL f•.. V 3 OF SUIL DIMIG RAOIATION p H w H W H AT SELECTED1 H M f/ AW Ots10N TEMP.-21 •ROOM'DIMENSIONS, FT. 1,- DIFFERENCE 3 LENQ'TH EXPOSED WALLS, FT. 4 WiNYOW AND OUTSIDE DOOR AREA ur b r BTUH 5 WALL CONSTRUCTION 13TUH BTUH BTUH BTUH Table 9, Line 3 x H) Lr, ti •j i :) c, t INCREASE BATHROOM 6 TYPE OF GLASS l TOTAL 20% 18ottom of table used for L:ne 5) 00 1: 2,7 CEILING CONSTRUCTIONtFOR CONCRETE FLOOR ONiTable9, L x W) C UGROUND OR FILL AT GRADELEVEL,USE LINEARBFLOORCONSTRUCTIONt( Table 9, L x W or Lin. Ft.) v n - v L o FEET OF EXPOSED EOQ1 9 COLD PARTITION CONSTRUCTION j 7 Table 9, L x H) 10 -e 1 Wall lWith Openings) I 5 c- 2 Wells(With Openings)X 3 Wells(With Openings)or Ent.Hall 10 J ' j o0 ov H H1-TOTAL BTUH AT 70F TEMP. DIFFERENCE' O u h G is D l CJU v vTOTALBTUHATDESIGNTEMP. DIFFERENCE LJ v z D J OCTr,is form is ava:looie rrom rho Hydronics Institute,35 Russo Place, Berk ley Heights,N J. 07922 FOAM k"3 FIMAL INSPECTIO iBuilding APPLICATION FOR BUILDING PERMIT HVAC' n C J 1 /S'Date: f L 15 WOOD POND ROADSprinkler eir 06 Electric Z Estimated Cost $ 1 Zoning zor, Permit Fee$ •oo Affidavit NO. 20475 Occupancy Fee $ Eng. Dept.COMPLETE RED BOXED AREAS. Fire Dept.TYPE OR PRINT ONLY Total Fee $ t •Qd Health Dept. SIGN ON REVERSE SIDE. Approved for CO: Additional Cost) $ TO BUiLDI EPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, reb lies to d rk accordin the followingspecifications: Job Location Lot No. Side of Street 4-42- _ Applicant Tel. Addres s • V S D ip Lic.# r STREET CITY ST if// AT, " ova to E Owner r (A)Is -' Address Is' Architect Address Size New Area: Ft.Front Overall Ft.Deep Overall Total Area Garages Size of Lot Dist. from St et Line _ Lavatories Bathrooms Rooms 1st 2nd 3rd Purpose of this Permit 4;A Sit S City Water Well Septic Sewer Use Group Construction Type GIS Approved by Date BD1A 11/88 I hereby agree to conform to all the requirem nts of the Laws of the State of Connecticut and th Ordinanc s of the Town of South Windsor and to notify the Building Inspector of any alteration in the plans or specifications of!he Building for whi h this mit is as ,an ree that this building is to be located the proper distance from all street lines,side yard nes d re t nc fro all er zone c#ig located in a zone in which this building and its use is allowed. e Signed I hereby apply for a Certificate of Occupancy for the work described in this plic iorrfflT'M it. Signed DO Nor WRITE BELOW THIS LIN INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# Inspections: HVAC Permit# Inspections: Electrical Permit#— 1, .Inspections: Sprinkler Permit# Inspections: Inspection / Approval Date By Appl Code Description Due Whom Code Comment r 93-20475-B 11,880 BO1 FOOTING 04/29/93 JFH A BACK & LEFT SIDE ONLY B03 FRAMING (ROUGH) 06/08/93 JFH A E03 ROUGH 06/08/93 JFH A B04 INSULATION 06/08/93 JFH A B04 INSULATION 06/08/93 JFH A B10 FINAL 02/14/95 JFH A 93-12569-E 450 Total Est Value 12, 330 BEING LOT # g ON A MAP ENTITLED : WOOD PONDS SECTION II SOUTH WINDSOR$CT. PROPERTY MAPPED FOR LOCAVA CONSTRUCTION COMPANY OPEN SPACE r6.88 0 9 O N oaf#FOUNDATION SHOWN rS LO Vi 7S•GS' z K 0 v 25.2' r N FOUNDATION 8 O LA 7 t.Zp' L=64'55 N 86"43'-Z4 w R=47'•oo, pM AS BUILT PLAN SAS.SFWER ... _ IT Ifc Owl' 4 ,r, , ?rig :;,itil f wmtrw POND ROAD Ir ti(4Fl Yf' IV ATTTT LUCHS & BECKERMAN CIVIL ENGINEERS - PLANNERS - LAND SURVEYORS GLASTONBURY,CONS. tONINO V'OL.RTi , CERTIPIRD SLOWTA"ALLY CORRECT. SCALE- 1"=40 i DATE- 12-28-82 ACCURACY CLASS A-2. E-80-68-9 APR Q 1 1993 South Viindsor BUILDING DEPARTMENT To ;W now" Ow. TOY M of ioul f. MM tllan and specifications are true oNd building or alterations to be Won VW 0 Street toMMf IN% amendments stated in apptieation any flied Vkh plan and I agree to comply with ail zoning, Building and s to laws and such otatere as shall b, isswd by e B Ilding Department d pendent) of this a4icatioiiand th s an f a b i 1118 permit.l J Signed Th pl N roved subject to the cond n that orders and ordinances regulating building shall be compiled with. Conditionally Approved These Mod with BuHding Inspector Ciark a C:W, buliding(s), use(s) and/or structure. s shown on this plan appear(s) to be In conforniance with current South Windsc:,; v egulations. Variances and special exceptlom, mey apply. Oate J ref , t I t it 3 9 /VAC ' c PERrIIT DEPARTMENT DECISION APPLICATION FOR ELECTRICAL PERMIT Application is hereby: TOWN OF SOUTH WINDSOR APPROVED DISAPPROVED BUILDING INSPECTION DEPT . 644-2511 Ext . 230 C Z9 J Application must be printed or typed . to ng Insplector 1 . LOCATION OF JOB W0041POrldo o, a FEE SCHEDULE No . Street 0 - $19000 - 10. 00 Floor Apt . No. Over $1,000 - 10.00 2 . OWNERper $1,000 or D fraction thereof 3 . ADDRESS 4 . APPLICANT 5 . ADDRESS 69 farm Road 4 6 r 6 . ESTIMATED COST $ -SO. 00 7 . IS THIS A CONTRACT COST YesVNo 8 . FEE ENCLOSED $ tox 09 . TYPE 0 BUILDING: ESIDENTIAL COMMERCIAL 10 . TYPE OF JOB: Original Installation t/Alteration epair BD 3A 11/88 APPLICATION FOR ELECTRICAL PERMIT (Continued from Reverse Side ) 11 . LOCATION OF JOB 15-WOO 0/)00"?0/ dCl' NO. STR ET APT. NO 12 . TYPE OF INSTALLATION 13. SIZE OF MAIN FEEDER 14. NO. OF LIGHT LOOPS 15 . NO. OF HEAT LOOPS 16. NO. OF POWER LOOPS 17 . NO. OF LIGHT OUTLETS 18. NO. OF HEAT CIRCUITS 19. NO. OF POWER OUTLETS 20. NO. OF CONVENIENCE OUTLETS 21. NO. OF HEAT CIRCUITS 22 . NO. OF POWER CIRCUITS 23. NO. OF LIGHT CIRCUITS 24. SIZE OF HEAT CIRCUITS 25 . NO. OF MOTORS 26. NO. OF PANELS 27 . TOTAL WATTAGE 28. NO. OF POWER FEEDERS 29 . NO. OF SWITCHES 30. A/C LOAD 31. SIZE OF POWER FEEDERS 32 . NO. OF FIXTURES 33. TOTAL HORSEPOWER 34 . NAME OF SUBCONTRACTORS AND THEIR TRADES 35 . REMARKS AND FURTHER DETAILS : 1 A 27d` LICENSE NO.SIGNATURE OF APPLICANT DATE PHONE NUMBER: Wejno froM TOWN OF SOUTH WINDSOR TOWN HALL SOUTH WINDSOR. CONN. 06074 F To Mrs. Frank Dzen DATE 10/06/94 15 Wood Pond Drive South Windsor, CT 06074 L SUBJECT: Wood Stove CO FOLD- Mrs. Dzen: I am returning your three dollars ($3) in cash which yousubmittedforacoforyourwoodstove. The Building Department is not requiring a CO for this type of permit. Instead,enclosed is a certificate showing that your stove has been inspected and approved. Thank you for your cooperation. BCorinne H. Murray Rai i 1 r i rrT Tln.- a r-mt n- i F1NjAL INSP Ruv"0i,Building ` APPLICATION FOR BUILDING PERMIT Plumbing HVAC 15 WOOD POND DRIVE Date: Sprinkler Electric Estimated Cost $ Zoning 21861 Permit Fee $ Affidavit NO.Occupancy Fee $ Eng. Dept.COMPLETE RED BOXED AREAS.Fire Dept.TYPE OR PRINT ONLY Total Fee $ Health Dept. Approved for CO: SIGN ON REVERSE SIDE.Additional Cost) $ TO BUILDING DEPARTMENT, TOWN OF SOUTH WINDSOR, CT The undersigned, hereby applies to do work according to the following specifications: Job Location Lot No. Side of Street Zone Applicant inAnc Tel. # Address I (.i l)')`) 0 Zip AL)? Lic.#an&746f STREET CITY STATE Owner ' r•'1I{ 1 n Address ./ ,- Architect Address Size New Area: Ft. Front Overall Ft. Deep Overall Total Area Garages Size of Lot Dist. from Street Line LavatoriesBathrooms Rooms 1st 2nd 3rd Purpose of this Permit (,JUL C_ d&U_e_ City Water 10 Well 11 Septic 0 Sewer 0 Use Group ,.,/ Construction Type Approved by Date Bo 1 A 11/88 I h reby agree to conform to all th requirements of th Laws of the State of Connecticut and th Ordinances of the Town of South Windsor _ and to notify the Building Inspector of any alteration in the plans or specifications of the Building for which this permit is asked,and agree that this building is to be located the proper distance from all street lines,side yard lines and required distances from all other zones and is located in a zone in which this building and its us is allowed. Signed 4J I hereby apply for a Certificate of Occupancy for the work described in this application for permit. Signed DO NOT WRITE BELOW THIS LINE— INSPECTION RECORD Footing Framing Foundation Fireplace/Chimney Insulation Plumbing Permit# Inspections: HVAC Permit# Inspections: Electrical Permit# Inspections: Sprinkler Permit# Inspections: Cn#tft e Pursuant to Permit No. 1 51 This Certifies that the Wood/Coal Stove installation for which the above named Permit was granted has been duly inspected and is hereby approved. Owner Mrs . Frank Dzen Street 15 Wood Pond Drive 1 10/06 19 94 wilding Inspector